Low energy backgrounds and excess noise in a two-channel low-threshold calorimeter

Here, we describe observations of low energy excess (LEE) events, background events observed in all light dark matter direct detection calorimeters, and noise in a transition edge sensor based two-channel silicon athermal phonon detector with 375 meV baseline energy resolution. We measure two distinct LEE populations: “shared” multichannel events with a pulse shape consistent with substrate athermal phonon events and sub-eV events that couple nearly exclusively to a single channel with a significantly faster pulse shape. These “singles” are consistent with events occurring within the aluminum athermal phonon collection fins. Similarly, our measured detector noise is higher than the theoretical expectation. Measured noise can be split into an uncorrelated component, consistent with shot noise from small energy depositions within the athermal phonon sensor itself, and a correlated component, consistent with shot noise from energy depositions within the silicon substrate's phonon system.

47 OTHER INSTRUMENTATION↗

Electronic thermal transport measurement in low-dimensional materials with graphene non-local noise thermometry

In low-dimensional systems, the combination of reduced dimensionality, strong interactions and topology has led to a growing number of many-body quantum phenomena. Thermal transport, which is sensitive to all energy-carrying degrees of freedom, provides a discriminating probe of emergent excitations in quantum materials and devices. However, thermal transport measurements in low dimensions are dominated by the phonon contribution of the lattice, requiring an experimental approach to isolate the electronic thermal conductance. In this work we measured non-local voltage fluctuations in a multi-terminal device to reveal the electronic heat transported across a mesoscopic bridge made of low-dimensional materials. Using two-dimensional graphene as a noise thermometer, we measured the quantitative electronic thermal conductance of graphene and carbon nanotubes up to 70 K, achieving a precision of ~1% of the thermal conductance quantum at 5 K. Employing linear and nonlinear thermal transport, we observed signatures of energy transport mediated by long-range interactions in one-dimensional electron systems, in agreement with a theoretical model.

36 MATERIALS SCIENCE↗

Broadband Solenoidal Haloscope for Terahertz Axion Detection

We introduce the Broadband Reflector Experiment for Axion Detection (BREAD) conceptual design and science program. This haloscope plans to search for bosonic dark matter across the [ 10 - 3 , 1 ] eV ([0.24, 240] THz) mass range. BREAD proposes a cylindrical metal barrel to convert dark matter into photons, which a novel parabolic reflector design focuses onto a photosensor. This unique geometry enables enclosure in standard cryostats and high-field solenoids, overcoming limitations of current dish antennas. A pilot 0.7 m 2 barrel experiment planned at Fermilab is projected to surpass existing dark photon coupling constraints by over a decade with one-day runtime. Axion sensitivity requires < 10 - 20 W / Hz sensor noise equivalent power with a 10 T solenoid and 10 m 2 barrel. We project BREAD sensitivity for various sensor technologies and discuss future prospects.

Liu, Jesse↗

Image-Based Methods to Score Fungal Pathogen Symptom Progression and Severity in Excised Arabidopsis Leaves

Image-based symptom scoring of plant diseases is a powerful tool for associating disease resistance with plant genotypes. Advancements in technology have enabled new imaging and image processing strategies for statistical analysis of time-course experiments. There are several tools available for analyzing symptoms on leaves and fruits of crop plants, but only a few are available for the model plant Arabidopsis thaliana (Arabidopsis). Arabidopsis and the model fungus Botrytis cinerea (Botrytis) comprise a potent model pathosystem for the identification of signaling pathways conferring immunity against this broad host-range necrotrophic fungus. Here, we present two strategies to assess severity and symptom progression of Botrytis infection over time in Arabidopsis leaves. Thus, a pixel classification strategy using color hue values from red-green-blue (RGB) images and a random forest algorithm was used to establish necrotic, chlorotic, and healthy leaf areas. Secondly, using chlorophyll fluorescence (ChlFl) imaging, the maximum quantum yield of photosystem II (Fv/Fm) was determined to define diseased areas and their proportion per total leaf area. Both RGB and ChlFl imaging strategies were employed to track disease progression over time. This has provided a robust and sensitive method for detecting sensitive or resistant genetic backgrounds. A full methodological workflow, from plant culture to data analysis, is described.

59 BASIC BIOLOGICAL SCIENCES↗

Absolute Magnetometry with He3

We report development of a highly accurate (parts per billion) absolute magnetometer based on 3He NMR. Optical pumping polarizes the spins, long coherence times provide high sensitivity, and the 3He electron shell effectively isolates the nuclear spin providing accuracy limited only by corrections including materials, sample shape, and magnetization. Our magnetometer was used to confirm calibration, to 32 ppb, of the magnetic-field sensors used in recent measurements of the muon magnetic moment anomaly g-2, which differs from the standard model by 2.4 ppm. With independent determination of the magnetic moment of 3He, this work will lead the way to a new absolute magnetometry standard.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

High-bandwidth frequency domain multiplexed readout of transition-edge sensors for neutrinoless double beta decay searches

The next-generation of cryogenic neutrinoless double-beta decay experiments require increasingly fast readout in order to improve background discrimination. These experiments, operated as cryogenic calorimeters at ∼ 10 mK, are usually read out by high-impedance neutron transmutation doped (NTD) thermistors, which provide good energy resolution, but are limited by ∼ 1 ms response times. Superconducting detectors, such as transition-edge sensors (TESs) with a time resolution of ∼ 100 μs, offer superior timing performance over NTD semiconductor bolometers. To make this technology viable for an application to a thousand or more channels, multiplexed readout is necessary in order to minimize the thermal load and radioactive contamination induced by the readout. Frequency-domain multiplexing readout (fMUX) for TESs, previously developed at Berkeley Lab and McGill University, is currently in use for mm-wave telescopes with detector sampling rates in the order of 100 Hz. We demonstrate a new readout system, based on the McGill/Berkeley digital fMux readout, to satisfy the higher bandwidth and noise requirements of the next generation of TES-instrumented cryogenic calorimeters. Each multiplexing readout module comprises 10 superconducting resonators in the 1–5 MHz range and a DC superconducting quantum interference device (DC-SQUID), interfaced to high-speed field programmable gate array (FPGA)-based electronics for digital signal processing and low-latency SQUID feedback. The new readout samples detectors at 156 kHz, three orders of magnitude faster than its cosmology-oriented predecessor, and demonstrates a stable feedback bandwidth of 3 kHz in a real TES-based system.

47 OTHER INSTRUMENTATION↗

Passive bias temperature compensation circuit module

A passive bias temperature compensation module for silicon photomultiplier, avalanche photodiodes and similar photodetectors that possess a moderately linear temperature coefficient of gain and that may be compensated by varying an applied bias voltage. The module includes an electrical circuit and a method for determining component values to provide a constant voltage source to stabilize the gain of one or more photodetector devices. A temperature sensor in the module is held in close thermal contact with the photodetector and a filter capacitor is electrically close to the photodetector. The module is based on the concept of temperature sensitive voltage division which is applicable to situations in which large numbers of photodetectors must be gain-compensated for temperature variations over a wide range while maintaining excellent gain matching. The passive bias temperature compensation method enables multiple photodetectors to share a single constant voltage supply without loss of matching performance.

42 ENGINEERING↗

Nuclear spin metrology with nitrogen vacancy center in diamond for axion dark matter detection

We present a method to directly detect the axion dark matter using nitrogen vacancy centers in diamonds. In particular, we use metrology leveraging the nuclear spin of nitrogen to detect axion-nucleus couplings. This is achieved through protocols designed for dark matter searches, which introduce a novel approach of quantum sensing techniques based on the nitrogen vacancy center. Although the coupling strength of the magnetic fields with nuclear spins is three orders of magnitude smaller than that with electron spins for conventional magnetometry, the axion interaction strength with nuclear spins is the same order of magnitude as that with electron spins. Furthermore, we can take advantage of the long coherence time by using the nuclear spins for the axion dark matter detection. Our method has the potential to be sensitive to a broad frequency range ≲ 100 Hz corresponding to the axion mass m a ≲ 4 × 10 − 13 eV . We present the detection limit of our method for both the axion-neutron and the axion-proton couplings and discuss its significance in comparison with other proposed ideas. We also show that the sensitivities of the NV center sensor to various spin species will open up new directions for constructing protocols that can mitigate magnetic noise effects. Published by the American Physical Society 2025

Chigusa, So (ORCID:0000000160054447)↗

Multi-qubit nanoscale sensing with entanglement as a resource

Nitrogen vacancy (NV) centres in diamond are widely deployed as local magnetic sensors, using single-qubit control to measure both time-averaged fields and noise with nanoscale spatial resolution. Moving beyond single qubits to multi-qubit control enables new sensing modalities such as measuring nonlocal spatiotemporal correlators or using entangled states to enhance measurement sensitivity. Here, in this work, we describe protocols for using optically unresolved NV centre pairs and nuclear spins as multi-qubit sensors for measuring correlated noise at nanometre length scales. For noninteracting NV centres, we implement a phase-cycling protocol that disambiguates magnetic correlations from variance fluctuations, leveraging the presence of a third qubit, a 13 C nucleus, to effect coherent single-NV spin flips and enable phase cycling even for co-aligned NV centres that are spectrally unresolved. For length scales around 10 nm, we create maximally entangled Bell states through dipole–dipole coupling between two NV centres and use these entangled states to directly read out the magnetic field correlation, rather than reconstructing it from independent measurements of unentangled NV centres. Importantly, this changes the scaling of sensitivity with readout noise from quadratic to linear. For conventional off-resonant readout of the NV centre spin state (for which the readout noise is roughly 30 times the quantum projection limit), this results in more than an order of magnitude improvement in sensitivity. Finally, we demonstrate methods for detecting high spatial- and temporal-resolution correlators with pairs of strongly interacting NV centres.

condensed-matter physics↗

Synthesis of a Hybrid Nanostructure of ZnO-Decorated MoS 2 by Atomic Layer Deposition

We introduce here the synthesis of hybrid nanostructures comprised of ZnO nanocrystals (NCs) decorating nanosheets and nanowires (NWs) of MoS 2 prepared by atomic layer deposition (ALD). The concentration, size, and surface-to-volume ratio of the ZnO NCs can be systematically engineered by controlling both the number of ZnO ALD cycles and the properties of the MoS 2 substrates, which are prepared by sulfurizing ALD MoO 3 . Analysis of the chemical composition combined with electron microscopy and synchrotron X-ray techniques as a function of the number of ZnO ALD cycles, together with the results of quantum chemical calculations, help elucidate the ZnO growth mechanism and its dependence on the properties of the MoS 2 substrate. The defect density and grain size of MoS 2 nanosheets are controlled by the sulfurization temperature of ALD MoO 3 , and the ZnO NCs in turn nucleate selectively at defect sites on MoS 2 surface and enlarge with increasing ALD cycle numbers. At higher ALD cycle numbers, the coalescence of ZnO NCs contributes to an increase in areal coverage and NC size. Furthermore, the geometry of the hybrid structures can be tuned by changing the dimensionality of the MoS 2 , by employing vertical NWs of MoS 2 as the substrate for ALD ZnO NCs, which in turn leads to improvement of the relevant surface-to-volume ratio. Such materials are expected to find use in newly expanded applications, especially those such as sensors or photo-devices based on a p-n heterojunction which relies on coupling transition metal dichalcogenides (TMDCs) with NCs.

36 MATERIALS SCIENCE↗

Shot‐Noise‐Driven Macroscopic Vibrations and Displacement Transduction in Quantum Tunnel Junctions

Back‐action is an inevitable result of quantum measurement. Although the microscopic impacts of shot‐noise back‐action have been explored, macroscopic evidence is seldom documented, especially in the field of electrical transport. Tunneling shot‐noise has been shown to excite the fundamental flexural mode of the host crystal using a sub‐GHz lumped‐element radio‐frequency quantum point contact (QPC). Here, in this study, this aspect of shot‐noise back‐action is examined at much higher operational frequencies and wider bandwidths by employing a GaAs QPC integrated into a planar superconducting cavity within the circuit‐QED framework, leading to the observation of the excitation of multiple mechanical modes. The device operates in the shot‐noise‐limited regime. Constructed on a piezoelectric platform, there is positive feedback between the electrical and mechanical degrees of freedom within the QPC. Shot‐noise excites piezoelectric vibrational modes; concurrently the resulting polarization charges enhance tunneling and develop peaks in the shot‐noise spectra at the modal frequencies. The excitation of vibrational modes is a macroscopic demonstration of measurement back‐action, and the amplitudes of the noise‐peaks enable us to calibrate the displacement sensitivity of the QPC‐resonator systems, which is in the range $≈ 35 fm/√ Hz$, making it an excellent sensor for ultra‐sensitive and rapid strain/displacement detection.

Kumbhakar, Prasanta [Indian Institute of Science E↗

Single-trial classification of evoked responses to auditory tones using OPM- and SQUID-MEG

Abstract Objective. Optically pumped magnetometers (OPMs) are emerging as a near-room-temperature alternative to superconducting quantum interference devices (SQUIDs) for magnetoencephalography (MEG). In contrast to SQUIDs, OPMs can be placed in a close proximity to subject’s scalp potentially increasing the signal-to-noise ratio and spatial resolution of MEG. However, experimental demonstrations of these suggested benefits are still scarce. Here, to compare a 24-channel OPM-MEG system to a commercial whole-head SQUID system in a data-driven way, we quantified their performance in classifying single-trial evoked responses. Approach. We measured evoked responses to three auditory tones in six participants using both OPM- and SQUID-MEG systems. We performed pairwise temporal classification of the single-trial responses with linear discriminant analysis as well as multiclass classification with both EEGNet convolutional neural network and xDAWN decoding. Main results. OPMs provided higher classification accuracies than SQUIDs having a similar coverage of the left hemisphere of the participant. However, the SQUID sensors covering the whole helmet had classification scores larger than those of OPMs for two of the tone pairs, demonstrating the benefits of a whole-head measurement. Significance. The results demonstrate that the current OPM-MEG system provides high-quality data about the brain with room for improvement for high bandwidth non-invasive brain–computer interfacing.

Iivanainen, Joonas (ORCID:0000000160344604)↗

Smartphone-based Dual-channel Immunochromatographic Test Strip with Polymer Quantum Dot Labels for Simultaneous Detection of Cypermethrin and 3-phenoxybenzoic acid

Currently, gas chromatography-mass spectrometry (GC-MS) and liquid chromatography-mass spectrometry (LC-MS) are the primary methods used to detect pesticides and their metabolites for biomonitoring of exposure. Although GC-MS and LC-MS can provide accurate and sensitive measurements, these techniques are not suitable for point-of-care or in-field biomonitoring applications. The objective of this work is to develop a smartphone-based dual-channel immunochromatographic test strip (ICTS) for on-site biomonitoring of exposure to cypermethrin by simultaneous detection of cypermethrin and its metabolite, 3-phenoxybenzoic acid (3-PBA). Polymer carbon dots (PCDs) with ultra-high fluorescent brightness were synthesized and used as signal amplifier in ICTS assay. Cypermethrin (a representative pyrethroid pesticide) and its major metabolite 3-PBA were simultaneously detected to provide more comprehensive analysis of cypermethrin exposure. After competitive immunoreactions between the target sample and the coating antigens preloaded on the test line, the tracer antibody (PCDs conjugated antibody) was quantitatively captured on the test lines. The captured PCDs were inversely proportional to the amount of the target compound in sample. The red fluorescence on the test line then was recorded by a smartphone-based device capable of conducting image analysis and recording. Under optimal conditions, the sensor showed excellent linear responses for detecting cypermethrin and 3-PBA ranging from 1 ng/mL to 100 ng/mL and from 0.1 ng/mL to 100 ng/mL, the limits of detection were calculated to be ~0.35 ng/mL for cypermethrin and ~0.04 ng/mL for 3-PBA, respectively. The results demonstrate that the ICTS device is promising for accurate point-of-care biomonitoring of pesticide exposure.

Zhao, Yuting↗

A low noise CMOS camera system for 2D resonant inelastic soft X-ray scattering

Resonant Inelastic X-ray Scattering (RIXS) is a powerful spectroscopic technique to study quantum properties of materials in the bulk. A novel variant of RIXS, called 2D RIXS, enables concurrent measurement of the scattered X-ray spectrum for a wide range of input energies, improving on the typically low throughput of 1D RIXS. In the soft X-ray domain, 2D RIXS demands an X-ray camera system with small pixels, large area, high quantum efficiency and low noise to limit the false detection rate in long duration exposures. We designed and implemented a 7.5 Megapixel back-illuminated CMOS detector with 5 μm pixels and high quantum efficiency in the 200–1,000 eV X-ray energy range for the QERLIN 2D RIXS spectrometer at the Advanced Light Source. The QERLIN beamline and detector are currently in commissioning. The camera noise from in-situ 3 s long dark exposures is 7e - or less and the leakage current is 6.5 × 10 -3 e - /(pixel ∙ s). For individual 500 eV X-rays, the expected efficiency is greater than 75% and the false detection rate is ~1 × 10 -5 per pixel.

47 OTHER INSTRUMENTATION↗

Production of High Yield, Ultra‐Shallow Nitrogen‐Vacancy Centre Ensembles Through High Purity Forming gas Annealing

Dense, ultra‐shallow (<10 nm from the surface) ensembles of nitrogen‐vacancy (NV) centers in diamond are sought‐after for realising practical quantum sensing at the nanoscale. However, these ensembles typically suffer from reduced NV creation efficiency and spin coherence compared to their deeper and bulk counterparts. Consequently, most demonstrations in the literature to date have been restricted to using single NV centers with atypical coherence and charge stability properties not achievable across entire ensembles. Here, in this work, we demonstrate that controlled annealing in a high purity forming gas atmosphere improves near‐surface NV formation efficiency to over 20%. This environment preserves a high quality hydrogen termination throughout the anneal, avoiding material etching over many hours at temperatures up to 1100°C and possibly helping to suppress vacancy out‐diffusion. We show that high temperature annealing is especially vital for improving spin properties in high density, ultra‐shallow implanted samples due to the localised damage profiles produced. By allowing the formation of high yield NV ensembles with improved spin properties, the optimised forming gas anneal can facilitate the reliable production of more sensitive diamond sensors than have previously been accessible.

Healey, Alexander J. [Royal Melbourne Institute of↗

Holographic Nano‐Imaging of Terahertz Dirac Plasmon Polaritons in Topological Insulator Antenna Resonators

Abstract Excitation of Dirac plasmon polaritons (DPPs) in bi‐dimensional materials have attracted considerable interest in recent years, both from perspectives of understanding their physics and exploring their transformative potential for nanophotonic devices, including ultra‐sensitive plasmonic sensors, ultrafast saturable absorbers, modulators, and switches. Topological insulators (TIs) represent an ideal technological platform in this respect because they can support plasmon polaritons formed by Dirac carriers in the topological surface states. Tracing propagation of DPPs is a very challenging task, particularly at terahertz (THz) frequencies, where the DPP wavelength becomes over one order of magnitude shorter than the free space photon wavelength. Furthermore, severe attenuation hinders the comprehensive analysis of their characteristics. Here, the properties of DPPs in real TI‐based devices are revealed. Bi 2 Se 3 rectangular antennas can efficiently confine the propagation of DPPs to a single dimension and, as a result, enhance the DPPs visibility despite the strong intrinsic attenuation. The plasmon dispersion and loss properties from plasmon profiles are experimentally determined, along the antennas, obtained using holographic near‐field nano‐imaging in a wide range of THz frequencies, from 2.05 to 4.3 THz. The detailed investigation of the unveiled DPP properties can guide the design of novel topological quantum devices exploiting their directional propagation.

Chemistry↗

Utilizing machine learning to improve the precision of fluorescence imaging of cavity-generated spin squeezed states

We present a supervised learning model to calibrate the photon collection rate during the fluorescence imaging of cold atoms. The linear regression model finds the collection rate at each location on the sensor such that the atomic population difference equals that of a highly precise optical cavity measurement. This 192 variable regression results in a measurement variance 27% smaller than our previous single variable regression calibration. The measurement variance is now in agreement with the theoretical limit due to other known noise sources. This model efficiently trains in less than a minute on a standard personal computer's CPU and requires less than 10 min of data collection. Furthermore, the model is applicable across a large change in population difference and across data collected on different days.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗