Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Quality Control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

WE-C-TOUR-I-01: Dosimters for QC in Diagnostic Imaging

Tour Leader: Xia Jiang, Ohio State University, Columbus, OH Tour Guides: Xia Jiang, Ohio State University, Columbus, OH Kevin Little, The University of Chicago, Chicago, IL Adrien Sanchez, University of Chicago, Chicago, IL Participating Vendors: IBA PTW - New York Radcal Corporation RTI Electronics, Inc. Exhibit Hall Guided Tours is a new program launching this year at the Annual Meeting. The Guided Tours are designed to enhance the interaction between meeting attendees and exhibitors. This year’s Imaging Guided Tours are organized around the theme of dosimeters for quality control in diagnostic imaging. Tours will begin with an introduction and background given by Dr. Xia Jiang, the Tour Leader. The introduction will cover the types and properties of different radiation dosimeters used for quality assurance in clinical radiology. Attendees will then break into smaller groups, each lead by an AAPM-member Tour Guide. The tour groups will visit the exhibit booths of vendors who provide appropriate dosimeters, and a vendor representative will give a presentation to the group about their particular product(s). The vendor representatives as well as the Tour Guides will be available to answer questions. Outline: Types and properties of radiation detectors and dosimeters Ionization chamber dosimeters Solid state dosimeters Dosimeter calibration: Primary and secondary standards dosimetry laboratories Instruments for measuring tube voltage and exposure time Vendor presentations will likely cover features and innovations of different dosimeter systems, as well as their practical use. Learning Objectives: Understand the types and properties of different instrumentations used for quality control in diagnostic imaging. Understand the process of dosimeter calibration. Gain familiarity with the latest commercial dosimeter systems from different vendors.

61 RADIATION PROTECTION AND DOSIMETRY↗

Ground Simulator Studies of the Effects of Valve Friction, Stick Friction, Flexibility, and Backwash on Power Control System Quality

Report presents results of tests made on a power control system by means of a ground simulator to determine the effects of various combinations of valve friction and stick friction on the ability of the pilot to control the system. Various friction conditions were simulated with a rigid control system, a flexible system, and a rigid system having some backlash. For the tests, the period and damping of the simulated airplane were held constant.

Brown, B Porter↗

Collaborative, Rapid Mapping of Water Extents During Hurricane Harvey Using Optical and Radar Satellite Sensors

On August 25, 2017, Hurricane Harvey made landfall between Port Aransas and Port O'Connor, Texas, bringing with it unprecedented amounts of rainfall and record flooding. In times of natural disasters of this nature, emergency responders require timely and accurate information about the hazard in order to assess and plan for disaster response. Due to the extreme flooding impacts associated with Hurricane Harvey, delineations of water extent were crucial to inform resource deployment. Through the USGS's Hazards Data Distribution System, government and commercial vendors were able to acquire and distribute various satellite imagery to analysts to create value-added products that can be used by these emergency responders. Rapid-response water extent maps were created through a collaborative multi-organization and multi-sensor approach. One team of researchers created Synthetic Aperture Radar (SAR) water extent maps using modified Copernicus Sentinel data (2017), processed by ESA. This group used backscatter images, pre-processed by the Alaska Satellite Facility's Hybrid Pluggable Processing Pipeline (HyP3), to identify and apply a threshold to identify water in the image. Quality control was conducted by manually examining the image and correcting for potential errors. Another group of researchers and graduate student volunteers derived water masks from high resolution DigitalGlobe and SPOT images. Through a system of standardized image processing, quality control measures, and communication channels the team provided timely and fairly accurate water extent maps to support a larger NASA Disasters Program response. The optical imagery was processed through a combination of various band thresholds and by using Normalized Difference Water Index (NDWI), Modified Normalized Water Index (MNDWI), Normalized Difference Vegetation Index (NDVI), and cloud masking. Several aspects of the pre-processing and image access were run on internal servers to expedite the provision of images to analysts who could focus on manipulating thresholds and quality control checks for maximum accuracy within the time constraints. The combined results of the radar- and optical-derived value-added products through the coordination of multiple organizations provided timely information for emergency response and recovery efforts.

SERVIR↗

Videos, photos, and AI-derived grain size data associated with “High-throughput AI Video Surveys Enable Reproducible Multiscale Sediment Size Mapping, with Implications for Hydrobiogeochemical Parameterization”

NOTE: The manuscript associated with this data package is currently in review. The data may be revised based on reviewer feedback. Upon manuscript acceptance, this data package will be updated with the final dataset and additional metadata. This data package is associated with the manuscript “High-throughput AI Video Surveys Enable Reproducible Multiscale Sediment Size Mapping, with Implications for Hydrobiogeochemical Parameterization” under review. This data package includes five data types: 1) raw photos and videos from drone survey and walking smartphone surveys; 2) images derived from raw videos; 3) manual labeling of reference scales; 4) metadata for all images and photo resolution derived from artificial intelligence (AI) models or manual labels, 5) grain size data obtained from AI models for all photos, 6) metadata and grain size data after quality control, 7) summaries of sample efficiency for all data, and 8) computational fluid dynamics (CFD) data used to support hydro-biogeochemical (HBGC) parameter estimation. Such data is used to 1) demonstrate significant improvements in accuracy, efficiency, and quality control for grain size data collection with the help of AI models, 2) study the spatial heterogeneity of grain size and observation reproducibility based on tens of thousands of data points generated by the AI models, and 3) evaluate the impacts of grain size heterogeneity on key HBGC parameters across sediment-to-reach and hourly-to-yearly scales. In particular, the data package contains 116 folders and 179696 files. The files include 41 videos in .mov format, 64047 photos in .jpg format, 13541 video-derived photos in .png format, 12747 segmentation mask data in .tif format, 12747 segmentation data in .json format, 24771 .csv files that with metadata and grain size for each individual photo as well as water depth and velocity data from CFD and observation, 51791 .txt files of raw AI predicted labels, and 11 flight record data in .srt format. The summary for all metadata and grain size statistics information is included in “Scales_V3_NG.csv” and “Statistics_V3_NG.csv”. The summary for data that pass data quality control (QC) level 0-2 is included in “QCStatistics_V3_NG.csv”. The QC level 0 represents photos whose photo resolution is positive, excluding photos that miss reference scale. The QC level 1 means reference scale circularity uncertainty is less than 5% for smartphone images while representing photo resolution is larger than 0.44 mm/pixel for drone images. The QC level 2 means excluding photos whose grain number is less than 100, a minimum number of grains recommended by classic literature. The summary for each video’s name, length, frame rates, survey area, grain number, survey efficiency, etc. can be found in “QCSummary_V3_NG.csv”. The summary for site name, GPS coordinates, and number of images at each site can be found in “SitesSummary_V3_*.csv” files. Overall computational efficiency summary is reported in Table 4 of accompanying manuscript. Additionally, the nitrate concentration data used in this work was downloaded from an existing dataset published on ESS-DIVE (Boat-Dragged Sensor Hanford Reach.csv; Conner A. et al., 2020). We thank the United States Forest Service, Washington Department of Fish and Wildlife, Washington Department of Natural Resources, Cowiche Canyon Conservatory, Port of Benton, and the Confederated Tribes and Bands of the Yakama Nation for access to field locations where the data were collected. We also thank the Yakama Nation Tribal Council and Yakama Nation Fisheries for working with us to facilitate data collection and optimization of data usage according to their values and worldview.

54 ENVIRONMENTAL SCIENCES↗

Quality assurance for image-guided radiation therapy utilizing CT-based technologies: A report of the AAPM TG-179

Purpose: Commercial CT-based image-guided radiotherapy (IGRT) systems allow widespread management of geometric variations in patient setup and internal organ motion. This document provides consensus recommendations for quality assurance protocols that ensure patient safety and patient treatment fidelity for such systems. Methods: The AAPM TG-179 reviews clinical implementation and quality assurance aspects for commercially available CT-based IGRT, each with their unique capabilities and underlying physics. The systems described are kilovolt and megavolt cone-beam CT, fan-beam MVCT, and CT-on-rails. A summary of the literature describing current clinical usage is also provided. Results: This report proposes a generic quality assurance program for CT-based IGRT systems in an effort to provide a vendor-independent program for clinical users. Published data from long-term, repeated quality control tests form the basis of the proposed test frequencies and tolerances.Conclusion: A program for quality control of CT-based image-guidance systems has been produced, with focus on geometry, image quality, image dose, system operation, and safety. Agreement and clarification with respect to reports from the AAPM TG-101, TG-104, TG-142, and TG-148 has been addressed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of Laboratory Analytical Methods for Uranium Analysis Superior Steel FUSRAP Site - 16606

The Superior Steel Site processed uranium metal in support of the Atomic Energy Commission's fuel-element development program in the 1950's, and was subsequently classified as a Formerly Utilized Sites Remedial Action Program (FUSRAP) Site. Previous investigations at the site identified uranium contamination both inside and outside the buildings associated with historic uranium metalworking activities. The U.S. Army Corps of Engineers (USACE) is currently engaged in the Remedial Investigation (RI) phase in accordance with the Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA) of 1980, as amended. As part of the RI, gamma spectroscopy analysis of environmental samples was performed on-site using a laboratory-grade, high-purity germanium (HPGe) spectrometer. The gamma spectroscopy analysis included isotopes of uranium and their progeny. As a quality assurance measure, a subset of samples already analyzed on-site were sent to a certified, commercial, off-site laboratory for analysis using a suite of analytical methods including gamma spectroscopy, alpha spectroscopy, and mass spectroscopy. As an element of the quality assurance program implemented for the RI, an assessment of the correlations between the various analytical methods employed by both the on-site and off-site laboratory was performed. This assessment revealed inconsistencies between on-site and off-site gamma spectroscopy analytical results, which raised concerns about the appropriateness and suitability of the analytical data. To resolve the data quality concerns and better understand the source(s) of analytical results variability, the Superior Steel RI team (USACE together with its contractor, Amec Foster Wheeler) developed a quality control test whose design objective was to control or practically eliminate sampling and sample preparation variability in order to focus more clearly on analytical variability. This paper discusses the results of this supplemental quality control test, showing the differences in the various analytical methods (both on-site and off-site). It demonstrates in a practical and real world setting how sample preparation and analytical variability, if not controlled and understood can impact data quality and data defensibility. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Operational Processing of Ground Validation Data for the Tropical Rainfall Measuring Mission

The Tropical Rainfall Measuring Mission (TRMM) satellite was successfully launched in November 1997. A primary goal of TRMM is to sample tropical rainfall using the first active spaceborne precipitation radar. To validate TRMM satellite observations, a comprehensive Ground Validation (GV) Program has been implemented for this mission. A key component of GV is the analysis and quality control of meteorological ground-based radar data from four primary sites: Melbourne, FL; Houston, TX; Darwin, Australia; and Kwajalein Atoll, RMI. As part of the TRMM GV effort, the Joint Center for Earth Systems Technology (JCET) at the University of Maryland, Baltimore County, has been tasked with developing and implementing an operational system to quality control (QC), archive, and provide data for subsequent rainfall product generation from the four primary GV sites. This paper provides an overview of the JCET operational environment. A description of the QC algorithm and performance, in addition to the data flow procedure between JCET and the TRNM science and Data Information System (TSDIS), are presented. The impact of quality-controlled data on higher level rainfall and reflectivity products will also be addressed, Finally, a brief description of JCET's expanded role into producing reference rainfall products will be discussed.

Kulie, Mark S.↗

Cellular response to small molecules that selectively stall protein synthesis by the ribosome

Identifying small molecules that inhibit protein synthesis by selectively stalling the ribosome constitutes a new strategy for therapeutic development. Compounds that inhibit the translation of PCSK9, a major regulator of low-density lipoprotein cholesterol, have been identified that reduce LDL cholesterol in preclinical models and that affect the translation of only a few off-target proteins. Although some of these compounds hold potential for future therapeutic development, it is not known how they impact the physiology of cells or ribosome quality control pathways. Here we used a genome-wide CRISPRi screen to identify proteins and pathways that modulate cell growth in the presence of high doses of a selective PCSK9 translational inhibitor, PF-06378503 (PF8503). The two most potent genetic modifiers of cell fitness in the presence of PF8503, the ubiquitin binding protein ASCC2 and helicase ASCC3, bind to the ribosome and protect cells from toxic effects of high concentrations of the compound. Surprisingly, translation quality control proteins Pelota (PELO) and HBS1L sensitize cells to PF8503 treatment. In genetic interaction experiments, ASCC3 acts together with ASCC2, and functions downstream of HBS1L. Taken together, these results identify new connections between ribosome quality control pathways, and provide new insights into the selectivity of compounds that stall human translation that will aid the development of next-generation selective translation stalling compounds to treat disease.

59 BASIC BIOLOGICAL SCIENCES↗

Improved Atmospheric Soundings and Error Estimates from Analysis of AIRS/AMSU Data

The AIRS Science Team Version 5.0 retrieval algorithm became operational at the Goddard DAAC in July 2007 generating near real-time products from analysis of AIRS/AMSU sounding data. This algorithm contains many significant theoretical advances over the AIRS Science Team Version 4.0 retrieval algorithm used previously. Three very significant developments of Version 5 are: 1) the development and implementation of an improved Radiative Transfer Algorithm (RTA) which allows for accurate treatment of non-Local Thermodynamic Equilibrium (non-LTE) effects on shortwave sounding channels; 2) the development of methodology to obtain very accurate case by case product error estimates which are in turn used for quality control; and 3) development of an accurate AIRS only cloud clearing and retrieval system. These theoretical improvements taken together enabled a new methodology to be developed which further improves soundings in partially cloudy conditions, without the need for microwave observations in the cloud clearing step as has been done previously. In this methodology, longwave C02 channel observations in the spectral region 700 cm-' to 750 cm-' are used exclusively for cloud clearing purposes, while shortwave C02 channels in the spectral region 2195 cm-' to 2395 cm-' are used for temperature sounding purposes. The new methodology for improved error estimates and their use in quality control is described briefly and results are shown indicative of their accuracy. Results are also shown of forecast impact experiments assimilating AIRS Version 5.0 retrieval products in the Goddard GEOS 5 Data Assimilation System using different quality control thresholds.

Susskind, Joel↗

Groundtruthing Next-Gen Sequencing for Microbial Ecology–Biases and Errors in Community Structure Estimates from PCR Amplicon Pyrosequencing

Analysis of microbial communities by high-throughput pyrosequencing of SSU rRNA gene PCR amplicons has transformed microbial ecology research and led to the observation that many communities contain a diverse assortment of rare taxa–a phenomenon termed the Rare Biosphere. Multiple studies have investigated the effect of pyrosequencing read quality on operational taxonomic unit (OTU) richness for contrived communities, yet there is limited information on the fidelity of community structure estimates obtained through this approach. Given that PCR biases are widely recognized, and further unknown biases may arise from the sequencing process itself, a priori assumptions about the neutrality of the data generation process are at best unvalidated. Furthermore, post-sequencing quality control algorithms have not been explicitly evaluated for the accuracy of recovered representative sequences and its impact on downstream analyses, reducing useful discussion on pyrosequencing reads to their diversity and abundances. Here we report on community structures and sequences recovered for in vitro-simulated communities consisting of twenty 16S rRNA gene clones tiered at known proportions. PCR amplicon libraries of the V3–V4 and V6 hypervariable regions from the in vitro-simulated communities were sequenced using the Roche 454 GS FLX Titanium platform. Commonly used quality control protocols resulted in the formation of OTUs with >1% abundance composed entirely of erroneous sequences, while over-aggressive clustering approaches obfuscated real, expected OTUs. The pyrosequencing process itself did not appear to impose significant biases on overall community structure estimates, although the detection limit for rare taxa may be affected by PCR amplicon size and quality control approach employed. Meanwhile, PCR biases associated with the initial amplicon generation may impose greater distortions in the observed community structure.

54 ENVIRONMENTAL SCIENCES↗

Automation and Intensity Modulated Radiation Therapy for Individualized High-Quality Tangent Breast Treatment Plans

Purpose: To demonstrate the large-scale clinical implementation and performance of an automated treatment planning methodology for tangential breast intensity modulated radiation therapy (IMRT). Methods and Materials: Automated planning was used to prospectively plan tangential breast IMRT treatment for 1661 patients between June 2009 and November 2012. The automated planning method emulates the manual steps performed by the user during treatment planning, including anatomical segmentation, beam placement, optimization, dose calculation, and plan documentation. The user specifies clinical requirements of the plan to be generated through a user interface embedded in the planning system. The automated method uses heuristic algorithms to define and simplify the technical aspects of the treatment planning process. Results: Automated planning was used in 1661 of 1708 patients receiving tangential breast IMRT during the time interval studied. Therefore, automated planning was applicable in greater than 97% of cases. The time for treatment planning using the automated process is routinely 5 to 6 minutes on standard commercially available planning hardware. We have shown a consistent reduction in plan rejections from plan reviews through the standard quality control process or weekly quality review multidisciplinary breast rounds as we have automated the planning process for tangential breast IMRT. Clinical plan acceptance increased from 97.3% using our previous semiautomated inverse method to 98.9% using the fully automated method. Conclusions: Automation has become the routine standard method for treatment planning of tangential breast IMRT at our institution and is clinically feasible on a large scale. The method has wide clinical applicability and can add tremendous efficiency, standardization, and quality to the current treatment planning process. The use of automated methods can allow centers to more rapidly adopt IMRT and enhance access to the documented improvements in care for breast cancer patients, using technologies that are widely available and already in clinical use.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Advanced manufacturing development of a composite empennage component for L-1011 aircraft

This is the final report of technical work conducted during the fourth phase of a multiphase program having the objective of the design, development and flight evaluation of an advanced composite empennage component manufactured in a production environment at a cost competitive with those of its metal counterpart, and at a weight savings of at least 20 percent. The empennage component selected for this program is the vertical fin box of the L-1011 aircraft. The box structure extends from the fuselage production joint to the tip rib and includes front and rear spars. During Phase 4 of the program, production quality tooling was designed and manufactured to produce three sets of covers, ribs, spars, miscellaneous parts, and subassemblies to assemble three complete ACVF units. Recurring and nonrecurring cost data were compiled and documented in the updated producibility/design to cost plan. Nondestruct inspections, quality control tests, and quality acceptance tests were performed in accordance with the quality assurance plan and the structural integrity control plan. Records were maintained to provide traceability of material and parts throughout the manufacturing development phase. It was also determined that additional tooling would not be required to support the current and projected L-1011 production rate.

Alva, T.↗

Improved Lunar Lander Handling Qualities Through Control Response Type and Display Enhancements

A piloted simulation that studied the handling qualities for a precision lunar landing task from final approach to touchdown is presented. A vehicle model based on NASA's Altair Lunar Lander was used to explore the design space around the nominal vehicle configuration to determine which combination of factors provides satisfactory pilot-vehicle performance and workload; details of the control and propulsion systems not available for that vehicle were derived from Apollo Lunar Module data. The experiment was conducted on a large motion base simulator. Eight Space Shuttle and Apollo pilot astronauts and three NASA test pilots served as evaluation pilots, providing Cooper-Harper ratings, Task Load Index ratings and qualitative comments. Each pilot flew seven combinations of control response types and three sets of displays, including two varieties of guidance and a nonguided approach. The response types included Rate Command with Attitude Hold, which was used in the original Apollo Moon landings, a Velocity Increment Command response type designed for up-and-away flight, three response types designed specifically for the vertical descent portion of the trajectory, and combinations of these. It was found that Velocity Increment Command significantly improved handling qualities when compared with the baseline Apollo design, receiving predominantly Level 1 ratings. This response type could be flown with or without explicit guidance cues, something that was very difficult with the baseline design, and resulted in approximately equivalent touchdown accuracies and propellant burn as the baseline response type. The response types designed to be used exclusively in the vertical descent portion of the trajectory did not improve handling qualities.

Mueller, Eric Richard↗

SU-E-I-04: A Mammography Phantom to Measure Mean Glandular Dose and Image Quality

Purpose: To evaluate mean glandular dose (MGD) and image quality in a selection of mammography systems using a novel phantom based on thermoluminescent dosemeters and the ACR wax insert. Methods: The phantom consists of two acrylic, 19 cm diameter, 4.5 cm thick, semicircular modules, used in sequence. The image quality module contains the ACR insert and is used to obtain a quality control image under automatic exposure conditions. The dosimetric module carries 15 TLD-100 chips, some under Al foils, to determine air kerma and half-value-layer. TL readings take place at our laboratory under controlled conditions. Calibration was performed using an ionization chamber and a Senographe 2000D unit for a variety of beam qualities, from 24 to 40 kV, Mo and Rh anodes and filters. Phantom MGD values agree, on the average, within 3% with ionization chamber data, and their precision is better than 10% (k=1). Results: MGD and image quality have been evaluated in a selection of mammography units currently used in Mexican health services. The sample includes analogic (screen/film), flexible digital (CR), and full-field digital image receptors. The highest MDG are associated to the CR technology. The most common image quality failure is due to artifacts (dust, intensifying screen scratches, and processor marks for film/screen, laser reader defects for CR). Conclusion: The developed phantom permits the MGD measurement without the need of a calibrated ionization chamber at the mammography site and can be used by a technician without the presence of a medical physicist. The results indicate the urgent need to establish quality control programs for mammography.

07 ISOTOPE AND RADIATION SOURCES↗

DEVELOPING AND EXPLOITING A UNIQUE DATASET FROM SOUTH AFRICAN GOLD MINES FOR SOURCE CHARACTERIZATION AND WAVE PROPAGATION

In this project, we are developing and exploiting a unique seismic dataset to address the characteristics of small seismic events and the associated seismic signals observed at local (< 200 km) and regional (< 2000 km) distances. The dataset is being developed using mining-induced events from three deep gold mines in South Africa recorded on in-mine networks (< 1 km) composed of tens of high-frequency sensors, a network of four broadband stations installed as part of this project at the surface around the mines (1-10 km), and a network of existing broadband seismic stations at local/regional distances (50-1000 km) from the mines. Data acquisition has now been completed and includes: (1) {approx}2 years (2007 and 2008) of continuous recording by the surface broadband array, and (2) tens of thousands of mine tremors in the -3.4 < ML < 4.4 local magnitude range. Events with positive magnitudes are generally well recorded by the surface-mine stations, while magnitudes of 3.0 and larger are seen at regional distances (up to {approx} 600 km) in high-pass filtered recordings. We have now completed the quality control of the in-mine data gathered at the three gold mines included in this project. The quality control consisted of: (1) identification and analysis of outliers among the P- and S-wave travel-time picks reported by the in-mine network operator and (2) verification of sensor orientations. The outliers have been identified through a 'Wadati filter' that searches for the largest subset of P- and S-wave travel-time picks consistent with a medium of uniform wave-speed. They have observed that outliers are generally picked at a few select stations. They have also detected that trigger times were mistakenly reported as origin times by the in-mine network operator, and corrections have been obtained from the intercept times in the Wadati diagrams. Sensor orientations have been verified through rotations into the local ray-coordinate system and, when possible, corrected by correlating waveforms obtained from theoretical and empirical rotation angles. Full moment tensor solutions have been obtained for selected events within the Savuka network volume, with moment magnitudes in the 0.5 < M{sub W} < 2.6 range. The solutions were obtained by inverting P-, SV-, and SH-spectral amplitudes measured on the theoretically rotated waveforms with visually assigned polarities. Most of the solutions have a non-zero implosive contribution (47 out of 76), while a small percentage is purely deviatoric (10 out of 76). The deviatoric moment tensors range from pure double couple to pure non-double couple mechanisms. We have also calibrated the regional stations for seismic coda-derived source spectra and moment magnitude using the envelope methodology of Mayeda et al. (2003). they tie the coda M{sub w} to independent values from waveform modeling. The resulting coda-based source spectra of shallow mining-related events show significant spectral peaking that is not seen in deeper tectonic earthquakes. This coda peaking may be an independent method of identifying shallow events and is similar to coda peaking with previously observed for Nevada explosions, where the frequency of the observed spectral peak correlates with the depth of burial (Murphy et al., 2009).

58 GEOSCIENCES↗

Contribution to the Development of DOE ARM Climate Best Estimate Data (ARMBE) Products: Land Surface Forcing and Evaluation Data Set (ARMBE-LAND) from the ARM SGP Site

To support the LLNL ARM Best Estimate Data Products (ARMBE) data development, the San Jose State University (SJSU)’s group will provide the LLNL team yearly data files (in a format consistent with ARMBE) that contain variables from the instruments defined in Table 1 for the ARM SGP site during the available period. The ARMBE-Land data product will blend multiple ARM observations including the Energy Balance Bowen Ratio Station (EBBR), Soil Water and Temperature System (SWATs) and CO2 Flux (CO2FLX) data sets. The SJSU group will process these datasets with stringent quality controls to remove suspicious data points and average quality-controlled data over a desired temporal resolution (one hour). A qc-flag will be assigned to each variable to indicate how many valid data points are used to get the hourly mean data, consistent with other ARMBE fileds.

54 ENVIRONMENTAL SCIENCES↗

Image processing system performance prediction and product quality evaluation

The author has identified the following significant results. A new technique for image processing system performance prediction and product quality evaluation was developed. It was entirely objective, quantitative, and general, and should prove useful in system design and quality control. The technique and its application to determination of quality control procedures for the Earth Resources Technology Satellite NASA Data Processing Facility are described.

Stein, E. K.↗

Standardizing Naming Conventions in Radiation Oncology

Purpose: The aim of this study was to report on the development of a standardized target and organ-at-risk naming convention for use in radiation therapy and to present the nomenclature for structure naming for interinstitutional data sharing, clinical trial repositories, integrated multi-institutional collaborative databases, and quality control centers. This taxonomy should also enable improved plan benchmarking between clinical institutions and vendors and facilitation of automated treatment plan quality control. Materials and Methods: The Advanced Technology Consortium, Washington University in St. Louis, Radiation Therapy Oncology Group, Dutch Radiation Oncology Society, and the Clinical Trials RT QA Harmonization Group collaborated in creating this new naming convention. The International Commission on Radiation Units and Measurements guidelines have been used to create standardized nomenclature for target volumes (clinical target volume, internal target volume, planning target volume, etc.), organs at risk, and planning organ-at-risk volumes in radiation therapy. The nomenclature also includes rules for specifying laterality and margins for various structures. The naming rules distinguish tumor and nodal planning target volumes, with correspondence to their respective tumor/nodal clinical target volumes. It also provides rules for basic structure naming, as well as an option for more detailed names. Names of nonstandard structures used mainly for plan optimization or evaluation (rings, islands of dose avoidance, islands where additional dose is needed [dose painting]) are identified separately. Results: In addition to its use in 16 ongoing Radiation Therapy Oncology Group advanced technology clinical trial protocols and several new European Organization for Research and Treatment of Cancer protocols, a pilot version of this naming convention has been evaluated using patient data sets with varying treatment sites. All structures in these data sets were satisfactorily identified using this nomenclature. Conclusions: Use of standardized naming conventions is important to facilitate comparison of dosimetry across patient datasets. The guidelines presented here will facilitate international acceptance across a wide range of efforts, including groups organizing clinical trials, Radiation Oncology Institute, Dutch Radiation Oncology Society, Integrating the Healthcare Enterprise, Radiation Oncology domain (IHE-RO), and Digital Imaging and Communication in Medicine (DICOM).

62 RADIOLOGY AND NUCLEAR MEDICINE↗