Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Property management”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

STAT7 v2.0 User Guide

The STAT7 software was developed to perform steady-state, single-phase thermal hydraulics analysis of plate-fueled reactors based on statistical propagation of uncertainties. Application of the software includes non-power research and test reactor analysis, and it has been used for the conversion to low- enriched uranium fuel of U.S. High Performance Research Reactors such as the Massachusetts Institute of Technology Research Reactor. Since it can be necessary to repeat reactor safety analysis, such as during fuel reloading, STAT7 accommodates flexibility in analyzing many practical aspects of reactor fuel management. STAT7 uses a Monte Carlo approach to model uncertainty in common fuel fabrication parameters and other key reactor operating parameters required for reactor thermal hydraulics analysis. These safety calculations are ultimately intended to protect against high fuel plate temperatures due to critical heat flux, or onset of flow instability. STAT7 supports water properties based on the IAPWS-IF97 functions (The International Association for the Properties of Water and Steam Industrial Formulation 1997 for the Thermodynamic Properties of Water and Steam) in addition to fitted functions. STAT7 predicts axial profiles of fuel, cladding, and coolant temperature along a lateral stripe that runs the full length of the fuel plate from the bottom to the top. STAT7 can simultaneously analyze every axial node in each lateral stripe of all fuel plates and coolant channels in every fuel element of an entire reactor core. Power splits are calculated for each axial node of each plate to determine how much of the power goes out each face of the plate. In a single execution, STAT7 can be used to perform full core analysis by analyzing the margin to onset of nucleate boiling and onset of flow instability for each axial node of each stripe of each plate of each fuel element in the core.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Understanding the E balance for water management in hydroxide exchange membrane fuel cells

As a key challenge for hydroxide exchange membrane fuel cells (HEMFCs), understanding water management deeply is critical for performance and durability improvement. Here, in this work, we show that the balance between water generation and phase-change-induced (PCI) flow is the main factor controlling cell voltage over a wide range of conditions where the cells are vulnerable to severe flooding. The regulation of flooding by heat generation can be reflected by a stable voltage with increase of current density in the polarization curve. This PCI balance voltage (E balance ), which determines the shape of polarization curve, is modeled as a function of cell operating conditions and gas diffusion layer (GDL) properties. Temperature, pressure, and thermal conductivity of GDL were found important for tuning the level of E balance , both in HEMFCs and proton exchange membrane fuel cells. The understanding of E balance will help to generate strategies for resolving flooding in HEMFCs, and it offers a new perspective for polarization curve interpretation.

25 ENERGY STORAGE↗

A review of thermal physics and management inside lithium-ion batteries for high energy density and fast charging

Traditionally it has been assumed that battery thermal management systems should be designed to maintain the battery temperature around room temperature. That is not always true as lithium-ion battery (LIB) R&D is pivoting towards the development of high energy density and fast charging batteries. Therefore, it is necessary to have a comprehensive review of thermal considerations for LIBs targeted for high energy density and fast charging, i.e., the optimal thermal condition, thermal physics (heat transport and generation) inside the battery, and thermal management strategies. As the energy density and charge rate increases, the optimal battery temperature can shift to be higher than room temperature. In the first part of the review various sources of heat generation inside LIBs and various approaches to minimizing battery heat generation are summarized. The importance of heat of mixing due to ion diffusion during fast charging is also highlighted. To improve the temperature uniformity and avoid excessive internal temperature rise, heat transfer inside the battery needs to be enhanced, and reducing the thermal contact resistance between the electrodes and separator can significantly increase the effective thermal conductivity of batteries. In the second part of the review various challenges and latest developments related to thermal transport and properties of LIBs are discussed. Finally, a summary of latest advancement on smart control of internal temperature of LIBs is discussed as depending on the ambient temperature and the optimal temperature; the battery heat needs to be retained or dissipated to elevate or avoid temperature rise.

25 ENERGY STORAGE↗

Experimental characterization of a triply periodic minimal surface PCM-to-air thermal energy storage device

Here, the expansion of energy production has intensified research into thermal energy storage (TES) to manage variability and improve system efficiency. Heat exchanger design is critical to achieving high power densities in TES systems. This study presents a high-surface-area phase change material (PCM)-to-air heat exchanger fabricated via resin-based stereolithography with a novel gyroid-based geometry tailored for enhanced performance. Material properties of the commercial PCM and resin were characterized using analytical techniques. A controlled air loop was used to evaluate heat transfer and pressure drop at various flow rates and inlet temperatures. Results show a strong dependence on the inlet temperature difference (ΔT) relative to the PCM melting point. During charging at the highest flow rate, increasing the inlet air temperature from ΔT = 5 °C to 20 °C above the melting point increased the average heat transfer rate by 187%. During discharging, decreasing the inlet temperature by the same ΔT below the melting point led to a 232% increase. Notably, the high-surface-area design enabled nearly symmetric charging and discharging behavior, a novel result for PCM-based TES systems which are often restricted by natural convection and other effects. The overall heat transfer coefficient was calculated and compared to values from standard design correlations. The maximum thermal effectiveness reached 95% at ΔT = 20 °C and a moderate flow rate of 34 m 3 /h. Peak coefficients of performance (COP) of 7 during charging and 6.4 during discharging were observed at ΔT = 20 °C and a low flow rate of 20 m 3 /h. These results demonstrate the viability of additively manufactured geometries for advanced TES applications.

25 ENERGY STORAGE↗

Tracking Thermal Transport in Colloidal Quantum Dot Films Using in Situ Time-Resolved X-ray Diffraction

Colloidal quantum dots (QDs) and their thin films are increasingly used in electronic and photonic devices replacing traditional bulk semiconductors. However, thermal properties of QDs remain underexplored relative to device development efforts. This study shows the use of time-resolved X-ray diffraction as a contact-free method to probe the thermal response of QDs in environments representative of the active layer in QD optoelectronic devices, providing in situ insights for future thermal management strategies. Through the extraction of Debye–Waller factors on a subnanosecond time scale, we directly capture the heating and cooling of core/shell CdSe/CdS QDs following pulsed optical excitation. In a QD thin film that actively provides optical gain, the thermal conductivity is found to be as low as 0.13 W m –1 K –1 , because of the poor heat flow between close-packed QD solids. For QDs dispersed in liquids, interfacial thermal conductance dominates thermal relaxation, with a conductance of 15 MW m –2 K –1 .

36 MATERIALS SCIENCE↗

Engineered Wood: Sustainable Technologies and Applications

Natural wood has been used for construction, fuel, and furniture for thousands of years because of its versatility, renewability, and aesthetic appeal. However, new opportunities for wood are arising as researchers have developed ways to tune the material's optical, thermal, mechanical, and ionic transport properties by chemically and physically modifying wood's naturally porous structure and chemical composition. Such modifications can be used to produce sustainable, functional materials for various emerging applications such as automobiles, construction, energy storage, and environmental remediation. In this review, we highlight recent advancements in engineered wood for sustainable technologies, including thermal and light management, environmental remediation, nanofluidics, batteries, and structural materials with high strength-to-weight ratios. Additionally, the current challenges, opportunities, and future of wood research are discussed, providing a guideline for the further development of next-generation, sustainable wood-based materials.

36 MATERIALS SCIENCE↗

Data supporting the article titled "Heterogeneous Multiphase Flow Properties of Volcanic Rocks and Implications for Noble Gas Transport from Underground Nuclear Explosions"

The submission is a Reproducible Research (RR) data archive that contains the supporting multiphase fluid flow and curve fitting results of the Vadose Zone Journal article titled: "Heterogeneous Multiphase Flow Properties of Volcanic Rocks and Implications for Noble Gas Transport from Underground Nuclear Explosions." The article's DOI number is the following: https://doi.org/10.1002/vzj2.20123. Please see the "Methods and Materials" section of the journal article and the ReadMe.txt in the RR_ARCHIVE folder for further details. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525. SAND Number: SAND2021-3407 O.

mercury injection capillary pressure↗

Adhesion Capabilities of Permanent Foaming Fixatives

DOE-EM have identified an operational requirement for a fixative that can immobilize and/or encapsulate residual contamination in 3D void volumes (pipes, gloveboxes, waste containers, etc.) during D and D activities. Failure to safely and effectively immobilize residual contamination can: Put workers at risk; Contaminate the public and environment; Drive up costs. Commercial-off-the-shelf (COTS) polyurethane (PU) foams is one possible solution and is currently being investigated by Savannah River National Lab (SRNL). Adhesion testing will dictate how well PU foams will adhere and immobilize residual contamination onto a substrate. Results can provide a performance criteria for Section 5 of ASTM E3191: Standard Specification for Permanent Foaming Fixatives Used to Mitigate Spread of Radioactive Contamination. Initial mechanical testing showed intumescent rigid PU foams were best in class (tensile, compression, TGA/DSC) Application of intumescent rigid PU foam in pipe scenario with 'contamination' showed excellent adhesion capabilities as long as foam had contact with pipe. The foam, however, was not able to penetrate 'contamination' but created pockets where the contamination interacted with the substrate. Pretreatment options of pipe were considered to produce better immobilization capabilities. Pretreatment options included COTS products like baking spray, rubber cement, and soap. Foam was still able to immobilize on a global sense, but not a local sense. Essentially acted as a mechanical plug. A tensile tester (MTS Criterion Series 43) was utilized to evaluate the tensile adhesion strength of 6 COTS PU foams. ASTM D1623: Tensile and Tensile Adhesion Properties of Rigid Cellular Plastics. Procedures: PU foams were cured between two smooth 2'' x 2'' 304 stainless steel coupons with hinges glued on plates for gripping support. Parameters Used: Pull rate of 0.1 in/min. Calculations: Tensile adhesion strength, elongation, and ImageJ analysis of how PU foam is left on substrate. Outcome: The PU foam with the best adhesion capabilities would be downselected for further evaluation to be used as a permanent foaming fixative. The rigid PU foams had the best adhesion capabilities with the R1 foam having a max load of 236 N. One of the I-R2 samples reached almost 450 N and another sample reached 2500 N before slipping. The other intumescent foam, I-F4, had the most coverage on the stainless steel coupon's surface from the ImageJ results (61.43% surface coverage). The intumescent foam, I-R2, will be the foam of choice for future testing due its fire retardant and adhesion capabilities. Future directions: Conduct the following experiment in a pipe scenario with the down-selected PU foam. Procedures: PU foam will be cured between in a 304 stainless steel pipe (ID: 4'', OD: 4.5'', Height: 4''). Parameters Used: Compression testing results will be referenced to determine if foam's adhesion strength would be greater its compression strength as its being compressed. Calculations: Compression strength, shear stress, total time elapsed. Conduct further adhesion testing with the down-selected PU foam (I-R2) to be treated as a permanent foaming fixative (PFF). Determine the minimum contact the PFF should have with the substrate for adequate results. Evaluate if PFF's adhesion capabilities is time dependent (3.1.5 of ASTM E3911). Subject PFF to seismic stressors addressed in Safety Basis of Interim Operation documents (SBIO) to further evaluate adhesion capabilities.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Borehole Disposal: Update on the Science, Technology, and Potentially Suitable Radioactive Wastes - 20170

A recent Special Issue of the Energies Journal on Deep Borehole Disposal of Nuclear Waste has delivered a timely update on the science and technology of borehole disposal and the types of radioactive wastes it could potentially accommodate. The Special Issue papers discuss (i) circumstances under which a national waste management programme might wish to consider deep borehole disposal [1], (ii) a status report of deep borehole disposal options in Germany [2], (iii) the use of deep horizontal drill-holes in sedimentary, metamorphic or igneous rocks for disposal of spent nuclear fuel and high-level radioactive waste [3], (iv) the analysis of corrosion performance of engineered barrier systems [4], (v) a review of the potential cementing systems suitable for deep borehole disposal [5], (vi) the thermal evolution around heat-generating waste for a wide range of material properties and disposal configurations [6], (vii) a geochemical analysis of deep brines focussed on fluid-rock interactions [7], (viii) post-closure performance assessment calculations for deep borehole disposal of Cs/Sr capsules [8], and (ix) an example safety case for deep borehole disposal of nuclear wastes [9]. This paper provides an overview of the main findings from these publications and highlights some of the technological and scientific challenges that need to be overcome when developing a deep borehole disposal concept. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Modeling the impact of high thermal conductivity paper on the performance and life of power transformers

Degradation of insulation paper is a key contributor to the failure of power transformers. Insulation degradation accelerates at elevated temperatures, which highlights the potential for better thermal management to prolong life. While several studies have analyzed the benefits of high thermal conductivity oil for reducing temperatures inside a transformer, this study is an initial assessment of the benefits of high thermal conductivity paper on transformer life. Blending particulates with cellulosic fibers offers a pathway for high thermal conductivity paper (with good dielectric properties), which can reduce internal temperatures. Presently, life extensions that can be achieved by the use of such thermally conducting papers were estimated, with the thermal conductivity of the paper being the key parameter under study. The analytical-numerical thermal model used in this study was validated against experimental measurements in a distribution transformer, adding confidence to the utility of the model. This model was then used to provide estimates of hot-spot temperature reduction resulting from the use of papers with higher thermal conductivity than baseline. Transformer life was predicted conventionally by tracking the degree of polymerization of paper over time, based on an Arrhenius model. Results indicate that increasing the thermal conductivity of paper from 0.2 W/mK (baseline) to 1W/mK reduces the hot spot temperature by 10°C. While degradation significantly depends on the moisture and oxygen content, the model shows that such a temperature reduction can increase life for all conditions, by as much as a factor of three.

42 ENGINEERING↗

dCache – Efficient Message Encoding For Inter-Service Communication in dCache: Evaluation of Existing Serialization Protocols as a Replacement for Java Object Serialization

As a well established, large-scale distributed storage system, dCache is used to manage and serve huge amounts of data collected by high energy physics, astrophysics and photon science experiments. Based on a microservices-like architecture, dCache is built as a modular distributed system, where each component provides a different core functionality. These services communicate by passing serialized messages to each other, a core behavior whose performance properties can consequently affect the entire system.This paper compares and evaluates different data serialization protocols in computer science with the objective of replacing and improving upon Java Object Serialization (JOS), which has increasingly presented itself as no longer being sufficiently performant for encoding messages. The criteria for choosing a new framework are collected, analyzed and formalized. The primary motivation for replacing Java serialization for encoding dCache messages is increasing the general speed of message-passing and thereby reducing the round-trip time for user requests. Emphasis is also placed on schema evolution capabilities and framework usability. Approaches for generalizing (de)serialization speed and size measurements based on data structure complexity are introduced, criteria for measuring documentation, learning curve, maintainability and introduction effort are defined. Finally, several selected serialization protocols are evaluated and compared accordingly, concluding with a recommendation for a suitable JOS replacement.

Morschel, Lea↗

Nonlinear behavior of urban flood peaks in the U.S. Mid-Atlantic region

Urbanization, i.e., increasing urban development areas in a watershed, is well known as a major cause of increasing flood magnitudes. This study analyzes the observed flood peaks at 262 watersheds in the U.S. Mid-Atlantic region with varying levels of urban development and free from reservoir impacts. Our analysis reveals an interesting, V-shaped nonlinear behavior: flood peaks first decrease and then increase with increasing percentage of urban development area at the watershed scale (PDAW), with the shift occurring at a PDAW threshold of around 10%. Regression analyses suggest that the V-shaped pattern primarily results from complex interactions among climate conditions (e.g., storm-event rainfall) and landscape properties (e.g., elevation, distance to the coast). A neural network model was then developed to capture such interactions, satisfactorily reproducing the V-shaped pattern with an R-squared value of 0.58, RMSE of 6.72 mm/day, and NSE of 0.55. These findings highlight the need to account for nonlinear dynamics in flood prediction and management in the coastal environment.

flood peaks↗

Testing of a Whole Home Energy Management System (Cooperative Research and Development Final Report)

NREL and B&B Technology Solutions Inc. will perform verification testing to demonstrate the effectiveness of our whole home energy management system. This energy management system will allow the electrification of various styles of homes reducing the emissions of CO2 by replacing existing fossil fuel-based home systems. CRADA benefit to DOE, Participant, and US Taxpayer: assists laboratory in achieving programmatic scope, and/or uses the laboratory's core competencies, and/or enhances U.S. competitiveness by utilizing DOE developed intellectual property and/or capabilities.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

DFT-based insight into finite-temperature properties of ferroelectric perovskites with lone-pair: the case of CsGeX 3 (X = Cl, Br, I)

Ferroelectrics remain in the focus of scientific attention for decades owing to their fundamental and practical appeal. Recently, ferroelectricity has been demonstrated in semiconducting halide perovskites (Zhang et al 2022 Sci. Adv. 8 eabj5881), offering both a rare combination of ferroelectricity and semiconductivity in the same material and a possible alternative to the prevailing perovskite oxide ferroelectrics. We propose a route to simulating such materials at finite temperatures capable of reproducing key experimental and first-principle data, such as Curie temperature, phase transition sequence, spontaneous polarization, and soft mode frequencies. The key methodological finding is the superior performance of hybrid exchange correlation functionals in parametrization of effective Hamiltonians for ferroelectrics with lone pair. The parametrization for effective Hamiltonians for CsGeX 3 (X = Cl, Br, I) is reported. The application of methodology to study polarization reversal in CsGeX 3 allows for the development of a ‘minimalistic’ model for polarization reversal in ferroelectrics that provides an insight into the mechanisms of polarization reversal and its key features, such as the relationship between the coercive field, temperature, and AC field frequency. Importantly, the model reveals the origin of the well-known and ever-puzzling overestimation of coercive fields in computations. Furthermore, we report a variety of finite-temperature properties of CsGeX 3 ferroelectrics, such as dielectric susceptibility, pyroelectric coefficients, and energy storage density, which reveal that these halide perovskites possess properties comparable to their oxide counterparts. Here, we believe that our work provides significant methodological advancements, deepens fundamental understanding of ferroelectrics, and reveals the potential of halide perovskite ferroelectrics.

effective Hamiltonian↗

Screening Evaluation of Sovereign NOH2O

Southwest Research Institute (SwRI) was contracted by Sovereign Hydroseal Energy, Inc to provide evaluation of the NOH2O polymer grout technology as a feasible tank bottom repair in support of Washington River Protection Solutions, LLC (WRPS) Solicitation #358012 Statement of Work (SOW) “Screening Evaluation of Sovereign NOH2O”, which a copy is located in Appendix A. The evaluation focused on screening the mechanical properties of NOH2O under normal, chemical and radiological conditions, which was identified as Task 2 of the SOW. Testing was performed in accordance with the SwRI Test Plan located in Appendix B.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Material Properties of Aged Rigid Polyurethane Foam

Foams are classified as either rigid or flexible and are commonly used in applications such as pipe insulation, carpet fibers, and chair foam cushions. Polyurethane foams are excellent thermal insulators, have excellent mechanical properties, and are chemically inert. With the addition of fire protective additives, polyurethane foams have the ability to intumescence when exposed to high temperatures. For the future storage of the 9977 nuclear shipping packages, the material properties of the General Plastics 3716 rigid polyurethane foam were evaluated for long term performance by comparing aged samples to unaged samples. General Plastics 3716 rigid polyurethane foam was aged from November 2014 to June 2019 at varying temperatures of: 160 deg. F, 160 deg. F + 50% relative humidity (RH), 185 deg. F, 215 deg. F, and 250 deg. F. The foam was then analyzed via Fourier Transform Infrared Spectroscopy (FTIR), 3D Optical Microscope, Thermal Gravimetric Analysis (TGA), Differential Scanning Calorimetry (DSC). FTIR and Optical Microscope: No significant change to chemical or physical structure was evident by FTIR or optical microscope analysis. DSC: Decrease of heat capacity over time for all oven temperatures except a slight increase for the 185 deg. F conditioned foams. Largest decrease evident with foams conditioned at 250 deg. F. A slight increase in heat capacity for humid samples. Similar trends in heat capacities at 71 deg. C and 102 deg. C. TGA: As conditioning temperature increased, a decline was evident in the average percent weight loss, onset temperature, and first derivative peak temperature. No significant effect due to humidity except for a decrease in first derivative peak temperature. Unaged samples exhibited strong intumescence. Foams conditioned at 160 deg. F exhibited slight intumescence. Results suggest fire protective additives decomposed at higher temperatures, which contributed to a lower average percent mass loss in higher temperature conditioning. Further thermal degradation testing would be beneficial to evaluate the ability of the conditioned foams to intumesce. Evaluate irradiation dose rate effects on conditioned foam. Possible conditioning in an environment with a known humidity or analyzing a new aliquot of sample for each trial to achieve a more representative heat capacity calculation.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

2020 LANL Contributions to the BATS Test in WIPP

The DOE Office of Nuclear Energy (DOE-NE) repository research and development program seeks to provide a sound technical basis for multiple viable disposal options, increase confidence in the robustness of generic disposal concepts, and develop science and engineering tools needed to support disposal concept implementation. Sandia, Los Alamos, and Lawrence Berkeley National labs are conducting research into salt, which includes the Brine Availability Test in Salt (BATS) field test at the Waste Isolation Pilot Plant (WIPP), a DOE Office of Environmental Management facility. BATS is leveraging the existing infrastructure associated with the WIPP to advance science informing generic disposal concepts. BATS is an ongoing heated borehole experiment being conducted in the WIPP underground. The goal of this experiment is to reduce the uncertainty associated with spent nuclear fuel disposition in geologic salt formations. The BATS experiments is designed to accomplish this by increasing our understanding of brine migration in salt, assessing damaged zones from mining and drilling, simulating a post-closure environment, confirming salt properties, and providing data for model validation. Phased testing for generic salt repository R&D was proposed in 2015. Subsequently, borehole thermal testing was developed as a first step in this process. This document summarizes the work conducted on the BATS experiment during fiscal year 2020 with an emphasis on the contributions by Los Alamos National Lab.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗