Redesigning the Jefferson Lab Hall A beam line for high precision parity experiments

The Continuous Electron Beam Accelerator Facility (CEBAF) was built with a thermionic electron source and the three original experimental hall lines reflected this. A few years after beam delivery began a parity violation experiment was approved and two polarimeters were installed in the Hall A beam line. The beam raster system was placed after the new Compton polarimeter, before one accelerator quadrupole and four quadrupoles in the new Moller polarimeter. It was very difficult to meet experimental requirements on envelope functions and raster shape with this arrangement so a sixth quadrupole was installed downstream of the Moller polarimeter to provide an additional degree of freedome. All of the parity experiments in Hall A have been run with this still-unsatisfactory configuration. The MOLLER experiment is predicated on achieving a 2% error on a 32 ppb asymmetry. Beam line changes are required to meet the systematic error budget. This work documents the existing beam line, an interim change which can be accomplished during a annual maintenance down, and the final configuration for MOLLER and subsequent experiments.

47 OTHER INSTRUMENTATION↗

Development of Industrial Prototype Spectropolarimeter for Medical Use Based on Liquid Crystal Polarization Diffraction Grating (Final Report)

This project will develop and design a prototype for an advanced spectro-polarimeter, which measures the polarization of light at various wavelengths. This spectro-polarimeter will combine the functionality of both spectrometer and polarimeter in one compact, lightweight and inexpensive device. Unlike devices on market today, this device allows for simultaneous, real-time measurements of fast biological processes. This advance in spectro-polarimeters can be applied in the chemical, medical and biological fields to research new drugs, control dynamics of drugs in blood, and improve medical diagnosis by enabling the study of tissue structure, cellular and sub-cellular structures of proteins and DNA. This project will also help develop other applications for such devices as imaging, identification of targets embedded in dense scattering media, and biochemical sensing.

99 GENERAL AND MISCELLANEOUS↗

Digital Correlation Microwave Polarimetry: Analysis and Demonstration

The design, analysis, and demonstration of a digital-correlation microwave polarimeter for use in earth remote sensing is presented. We begin with an analysis of three-level digital correlation and develop the correlator transfer function and radiometric sensitivity. A fifth-order polynomial regression is derived for inverting the digital correlation coefficient into the analog statistic. In addition, the effects of quantizer threshold asymmetry and hysteresis are discussed. A two-look unpolarized calibration scheme is developed for identifying correlation offsets. The developed theory and calibration method are verified using a 10.7 GHz and a 37.0 GHz polarimeter. The polarimeters are based upon 1-GS/s three-level digital correlators and measure the first three Stokes parameters. Through experiment, the radiometric sensitivity is shown to approach the theoretical as derived earlier in the paper and the two-look unpolarized calibration method is successfully compared with results using a polarimetric scheme. Finally, sample data from an aircraft experiment demonstrates that the polarimeter is highly-useful for ocean wind-vector measurement.

Piepmeier, J. R.↗

Airborne and Shipborne Polarimetric Measurements over Open Ocean and Coastal Waters: Intercomparisons and Implications for Spaceborne Observations

Comprehensive polarimetric closure is demonstrated using observations from two in-situ polarimeters and Vector Radiative Transfer (VRT) modeling. During the Ship-Aircraft Bio-Optical Research (SABOR) campaign, the novel CCNY HyperSAS-POL polarimeter was mounted on the bow of the R/V Endeavor and acquired hyperspectral measurements from just above the surface of the ocean, while the NASA GISS Research Scanning Polarimeter was deployed onboard the NASA LaRC's King Air UC-12B aircraft. State-of-the-art, ancillary measurements were used to characterize the atmospheric and marine contributions in the VRT model, including those of the High Spectral Resolution Lidar (HSRL), the AErosol RObotic NETwork for Ocean Color (AERONET-OC), a profiling WETLabs ac-9 spectrometer and the Multi-spectral Volume Scattering Meter (MVSM). An open-ocean and a coastal scene are analyzed, both affected by complex aerosol conditions. In each of the two cases, it is found that the model is able to accurately reproduce the Stokes components measured simultaneously by each polarimeter at different geometries and viewing altitudes. These results are mostly encouraging, considering the different deployment strategies of RSP and HyperSAS-POL, which imply very different sensitivities to the atmospheric and ocean contributions, and open new opportunities in above-water polarimetric measurements. Furthermore, the signal originating from each scene was propagated to the top of the atmosphere to explore the sensitivity of polarimetric spaceborne observations to changes in the water type. As expected, adding polarization as a measurement capability benefits the detection of such changes, reinforcing the merits of the full-Stokes treatment in modeling the impact of atmospheric and oceanic constituents on remote sensing observations.

Matteo Ottaviani↗

TPSAS-NF1676L-34013-DND

Currently, many experiments pursuing comprehensive characterization of the atmosphere include coordinated observations by both lidar and polarimeters in order to obtain important complimentary information about aerosol properties. The most advanced passive observations by space-based multi-angle polarimeters are sensitive to the properties of aerosol in total atmospheric column, but have very limited sensitivity to vertical structure of the atmosphere. Polarimeter observations can be used not only for retrieval of aerosol optical thickness, but also for deriving microphysical information about aerosol particle shape, size distribution, complex refractive index, and the properties of underlying surface (Dubovik et al., 2019). In a contrast, the lidar observations of atmospheric responses from different altitudes to laser pulses are designed to provide vertical profiles of atmospheric characteristics. Here we present the recent advancement in GRASP algorithm (Generalized Aerosol Retrieval of Atmospheric and Surface Properties) (Dubovik et al., 2011, 2014) that allows simultaneous inversion of co-incident lidar and polarimeter spaceborne observations and derives a united set of vertically resolved aerosol and surface parameters. Such synergetic retrieval is an extension to satellite data of the approach for synergetic processing of active and passive measurements developed earlier by (Lopatin et al., 2013) for ground-based observations. Another addition to these developments is the inclusion of Raman-shifted and volume depolarization backscattering observations that improve sensitivity to the vertical properties of aerosol, while polarimetric observations provide sufficient constraints on aerosol type and loading that generally are missing in lidar signals. The potential and limitations of such synergetic processing is illustrated by application to co-incident PARASOL and CALIPSO data.

Anton Lopatin↗

TPSAS-NF1676L-28149-DND

An Optimal Estimation (OE) inversion method has been developed to retrieve vertical profiles of aerosol size distributions, volume/surface concentrations, complex refractive indices, and single scattering albedos using the High Spectral Resolution Lidar (HSRL) and polarimeter measurements. By combining the active and passive remote sensing data, we can take advantages of the high vertical resolution of the lidar measurements and the high information content of the combined observations. There are three components to the new retrieval system: 1) simultaneous aerosol vertical profile retrieval using HSRL data, 2) standalone aerosol retrieval using Research Scanning Polarimeter (RSP), and 3) combined HSRL and RSP optimal estimation retrieval. For the LIDAR retrieval, we solve for number concentrations, mode fractions, aerosol size distributions, and real and imaginary part of refractive indices simultaneously. Based on this information, other parameters such as effective particle radius, surface and volume concentration, single scattering albedo can be derived. The combined HSRL-polarimeter algorithm will provide improved single scattering albedo and refractive index retrievals. The newly developed retrieval algorithm is very fast, and it provides an optimal estimation solution with associated error estimates. By solving for the aerosol vertical profiles using HSRL extinctions and backscattering coefficients from different layers, the new OE method can effectively reduce the impact of measurement noise on the retrieved aerosol microphysical properties. It also enables us to effectively combing HSRL and RSP data in the single OE retrieval system since the passive polarimeter instruments measure path-integrated intensity and polarizations. We have performed sensitivity studies using simulated data and applied the OE algorithms to NASA airborne field data measured by the HSRL-2 and the RSP instruments.

Xu Liu↗

PACE Microphysical Aerosol Properties from Polarimetry (PACE-MAPP)

We present the Plankton, Aerosols, Clouds and Ecosystems Microphysical Aerosol Properties from Polarimetry (PACE-MAPP) polarimetric remote sensing algorithm developed for the newly launched NASA PACE satellite observing system. The objective of PACE-MAPP is to retrieve detailed fine-mode (marine, pollution and smoke) and coarse-mode (sea-salt and dust) aerosol properties over the ocean for a range of light to heavy aerosol loadings using PACE’s polarimetric-imaging capabilities at multiple angles and wavelengths from the ultraviolet (UV) to the near-infrared (NIR). An additional objective for PACE-MAPP is to discriminate aerosols from thin clouds. The PACE-MAPP polarimetric remote sensing retrieval algorithm uses coupled atmosphere-ocean vector radiative transfer, optimal estimation, artificial intelligence and powerful inherent optical property look-up-tables for the Earth’s aerosol, cloud, and hydrosol particles. PACE-MAPP is the only retrieval algorithm designed to invert aerosol/ocean products using both polarimeters onboard PACE. We present results using PACE-MAPP to retrieve aerosol and ocean remote sensing products from measurements by the Hyper-Angular Rainbow Polarimeter #2 (HARP2) and Spectro-polarimeter for Planetary Exploration one (SPEXone) polarimeter instruments onboard PACE.

Snorre Stamnes↗

Precision Electron Beam Polarimetry in Hall C at Jefferson Lab

The electron beam polarization in experimental Hall C at Jefferson Lab is measured using two devices. The Hall-C/Basel M\o ller polarimeter measures the beam polarization via electron-electron scattering and utilizes a novel target system in which a pure iron foil is driven to magnetic saturation (out of plane) using a superconducting solenoid. A Compton polarimeter measures the polarization via electron-photon scattering, where the photons are provided by a high-power, CW laser coupled to a low gain Fabry-Perot cavity. In this case, both the Compton-scattered electrons and backscattered photons provide measurements of the beam polarization. Results from both polarimeters, acquired during the Q-Weak experiment in Hall C, will be presented. In particular, the results of a test in which the M\o ller and Compton polarimeters made interleaving measurements at identical beam currents will be shown. In addition, plans for operation of both devices after completion of the Jefferson Lab 12 GeV Upgrade will also be discussed.

Gaskell, David↗

Compton Polarimetry at ELSA

Part of the future polarization program performed at the Bonn accelerator facility ELSA will rely on precision Compton polarimetry of the stored transversely polarized electron beam. Precise and fast polarimetry poses high demands on the light source and the detector which were studied in detail performing numerical simulations of the Compton scattering process. In order to experimentally verify these calculations, first measurements were carried out using an argon ion laser as light source and a prototype version of a counting silicon microstrip detector. Calculated and measured intensity profiles of backscattered photons are presented and compared, showing excellent agreement. Background originating from beam gas radiation turned out to be the major limitation of the polarimeter performance. In order to improve the situation, a new polarimeter was constructed and is currently being set up. Design and expected performance of this polarimeter upgrade are presented.

43 PARTICLE ACCELERATORS↗

Polarimetry at the Superconducting Darmstadt Electron Linac S-DALINAC

A spin polarized electron source will be installed at the S-DALINAC to extend the existing experimental capabilities polarization. In order to manipulate and monitor the beam polarization a Wien filter and different polarimeters will be installed. The already installed Wien filter and 100 keV Mott polarimeter and the planned 5 MeV Mott, 30-130 MeV Moeller and Compton transmission polarimeters are described.

43 PARTICLE ACCELERATORS↗

Diamond Detectors for Compton Polarimetry

Parity-violating electron scattering experiments aim to test the standard model of particle physics through precise low-energy determinations of the weak mixing angle. These experiments require determination of the polarization of the incident electron beam to the 1% level or better. An example of this type of experiment is the Q-weak experiment, which will be conducted in Hall C at Jefferson Lab in 2010 and beyond. We are constructing a Compton polarimeter in Hall C to provide continuous monitoring of the polarization with the goal of 1% absolute polarization determination. In our Compton polarimeter, circularly polarized laser light will impinge upon the electron beam. Electrons scattered by the Compton process will be momentum-analyzed in a dipole magnet downstream of the interaction point. A diamond strip tracker will be placed further downstream of the dipole to sense the Compton-scattered electrons and determine their momenta. The design of the polarimeter, focusing on electron detection, and our progress in prototyping and constructing the diamond strip tracker, are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Magnetohydrodynamic interference with the edge pedestal motional Stark effect diagnostic on DIII-D

Accurate measurement of internal magnetic field direction using motional Stark effect (MSE) polarimetry in the edge pedestal is desired for nearly all tokamak scenario work. A newly installed 500 kHz 32-channel digitizer on the MSE diagnostic of DIII-D allows full spectral information of the polarimeter signal to be recovered for the first time. Fourier analysis of this data has revealed magnetohydrodynamic (MHD) fluctuations in the plasma edge pedestal at {rho}{>=} 0.92. By correlating edge localized mode fluctuations seen on lock-in amplifier outputs with MSE spectrograms, it has been shown that edge pedestal tearing mode fluctuations cause interference with MSE second harmonic instrument frequencies. This interference results in unrecoverable errors in the real-time polarization angle measurement that are more than an order of magnitude larger than typical polarimeter uncertainties. These errors can cause as much as a 38% difference in local q. By using a redundant measure of the linear polarization found at the fourth harmonic photo-elastic modulator (PEM) frequency, MHD interference can be avoided. However, because of poorer signal-to-noise the fourth harmonic signal computed polarization angle shows no improvement over the MHD polluted second harmonics. MHD interference could be avoided in future edge pedestal tokamak polarimeters by utilizing PEMs with higher fundamental frequencies and a greater separation between their frequencies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Identification of errors in the electron density measurements of a tangential interferometer/polarimeter system during a tokamak discharge

A new method for the comparative verification of electron density measurements obtained with a tangential interferometer and a polarimeter during a discharge is proposed. The possible errors associated with the interferometer and polarimeter are classified by the time required for their identification. Based on the characteristics of the errors, the fringe shift error of the interferometer and the low-frequency noise of the polarimeter were identified and corrected for the JT-60U tangential interferometer/polarimeter system.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Polarimetry at MAMI

Möller and Mott polarimeters have been compared concerning their measurement accuracy in a dedicated 'spin dance' experiment. The results obtained with the different polarimeters at vastly different energy ranges were in agreement with each other within the given systematic uncertainties of a few percent. We discuss investigations of background conditions which may allow to reduce this important contribution to the uncertainties in the Mott polarimeter to a value below 1.0%.

43 PARTICLE ACCELERATORS↗

Design and optimization of a modular setup for measurements of three-dimensional spin polarization with ultrafast pulsed sources

ULTRASPIN is an apparatus devoted to the measurement of the spin polarization (SP) of electrons ejected from solid surfaces in a UHV environment. It is designed to exploit ultrafast light sources (free electron laser or laser high harmonic generation) and to perform (photo)electron spin analysis by an arrangement of Mott scattering polarimeters that measure the full SP vector. The system consists of two interconnected UHV vessels: one for surface science sample cleaning treatments, e-beam deposition of ultrathin films, and low energy electron diffraction/AES characterization. The sample environment in the polarimeter allows for cryogenic cooling and in-operando application of electric and magnetic fields. The photoelectrons are collected by an electrostatic accelerator and transport lens that form a periaxial beam that is subsequently directed by a Y-shaped electrostatic deflector to either one of the two orthogonal Mott polarimeters. The apparatus has been designed to operate in the extreme conditions of ultraintense single-X-ray pulses as originated by free electron lasers (up to 1 kHz), but it allows also for the single electron counting mode suitable when using statistical sources such as synchrotron radiation, cw-laser, or e-gun beams (up to 150 kcps).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Deuteron beam polarimetry at the nuclotron

The scheme of the deuteron beam polarization measurements at Nuclotron are presented. A deuteron beam polarimeter based on the spin-asymmetry measurements in the dp -elastic scattering at large angles in center-of-mass system has been constructed at the internal target station at the Nuclotron of JINR. This polarimeter is planned to use for the measurements of the vector and tensor components of deuteron beam polarizations at the energies 270–2000 MeV simultaneously. Details on the low energy polarimeters are also discussed.

43 PARTICLE ACCELERATORS↗

Effect of 3D Polarization profiles on polarization measurements and colliding beam experiments

The development of polarization profiles are the primary reason for the loss of average polarization. Polarization profiles have been parametrized with a Gaussian distribution. We derive the effect of 3-dimensional polarization profiles on the measured polarization in polarimeters, as well as the observed polarization and the figure of merit in single and double spin experiments. Examples from RHIC are provided. The Relativistic Heavy Ion Collider (RHIC) is the only collider of spin polarized protons. During beam acceleration and storage profiles of the polarization P develop, which affect the polarization measured in a polarimeter, and the polarization and figure of merit (FOM) in colliding beam experiments. We calculate these for profiles in all dimensions, and give examples for RHIC. Like in RHIC we call the two colliding beams Blue and Yellow. We use the overbar to designate intensity-weighted averages in polarimeters (e.g. {bar P}), and angle brackets to designate luminosity-weighted averages in colliding beam experiments (e.g. <P>).

43 PARTICLE ACCELERATORS↗

STUDIES OF THE ORIGIN OF HIGH-FREQUENCY QUASI-PERIODIC OSCILLATIONS OF MASS-ACCRETING BLACK HOLES IN X-RAY BINARIES WITH NEXT-GENERATION X-RAY TELESCOPES

Observations with RXTE ( Rossi X-ray Timing Explorer ) revealed the presence of high-frequency quasi-periodic oscillations (HFQPOs) of the X-ray flux from several accreting stellar-mass black holes. HFQPOs (and their counterparts at lower frequencies) may allow us to study general relativity in the regime of strong gravity. However, the observational evidence today does not yet allow us to distinguish between different HFQPO models. In this paper we use a general-relativistic ray-tracing code to investigate X-ray timing spectroscopy and polarization properties of HFQPOs in the orbiting Hotspot model. We study observational signatures for the particular case of the 166 Hz quasi-periodic oscillation (QPO) in the galactic binary GRS 1915+105. We conclude with a discussion of the observability of spectral signatures with a timing-spectroscopy experiment such as the LOFT ( Large Observatory for X-ray Timing ) and polarization signatures with space-borne X-ray polarimeters such as IXPE ( Imaging X-ray Polarimetry Explorer ), PolSTAR ( Polarization Spectroscopic Telescope Array ), PRAXyS ( Polarimetry of Relativistic X-ray Sources ), or XIPE ( X-ray Imaging Polarimetry Explorer ). A mission with high count rate such as LOFT would make it possible to get a QPO phase for each photon, enabling the study of the QPO-phase-resolved spectral shape and the correlation between this and the flux level. Owing to the short periods of the HFQPOs, first-generation X-ray polarimeters would not be able to assign a QPO phase to each photon. The study of QPO-phase-resolved polarization energy spectra would thus require simultaneous observations with a first-generation X-ray polarimeter and a LOFT -type mission.