Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Permanent Magnets”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Degradation of Magnetic Materials for High-Temperature Active Magnetic Bearing Applications in CO₂-Based Environments

High-temperature Active Magnetic Bearings (AMBs) are a promising alternative to conventional bearings in hermetically sealed turbomachinery for supercritical CO₂ (sCO₂) systems. They offer reduced CO₂ leakage, lower windage losses, enhanced misalignment tolerance, reduced wear, and built-in diagnostic capabilities. A critical challenge, however, is ensuring long-term material stability in harsh CO₂-rich environments. This study investigated the degradation behavior of permanent and soft magnetic materials (Alnico 9C, Alnico 5-7C, SmCo 18-T550, Hiperco-50, and coated variants) after up to 6,000 hours of exposure in gaseous CO₂, sCO₂, or air at 450 °C and 550 °C. The evaluation included post-exposure mass change measurements, scanning electron microscopy (SEM) analysis, and magnetic property assessments. The results demonstrate oxidation rates, microstructural evolution, and retention of magnetic performance across conditions. The findings offer essential insights into the thermal corrosion behavior of magnetic materials under CO₂ rich environments and serve as a reference for material selection in AMB system designs.

36 MATERIALS SCIENCE↗

Feasibility of FDEM cross-dipole and TDEM loop sources for monitoring CO 2 at the Kemper CarbonSAFE site

Electromagnetics has been shown to be a viable tool to monitor CO 2 plumes embedded in saline reservoirs. However, the majority of studies focus on measuring the electric field, which requires cumbersome equipment in the field and it is difficult to install permanent measurement stations. Magnetic field receivers offer an opportunity to reduce the form factor of the survey and increase the mobility by utilizing upcoming technologies, such as drones. We explore the use of frequency-domain electric dipole sources, and timedomain loops with a focus on measuring the secondary magnetic field at the surface for a conceptual injection scenario based on the Kemper CarbonSAFE site. We find that electric dipole sources give a response above the sensitivity of current sensor technology and, therefore, be a viable tool for CO 2 monitoring. The time domain loop source does provide fields that are useful for determining the location of the CO 2 plume, however the field magnitude is below the sensitivity of the current generation of instruments. To explore the use of a potential borehole receiver we generate a map of the magnetic field at depth to explore potential borehole placement for monitoring efforts. Finally, we limit the spatial extent of the electric dipole survey to a single parcel of land to help understand how the fields change with survey geometry. We find that the shape of the secondary fields change slightly with the small transmitter, but are still measurable provided that the cultural noise at the site is low. Thus, we conclude that at the Kemper site a frequency-domain cross-dipole source with magnetometer receivers is suitable to monitor the expansion of the CO 2 plume in the saline reservoir, even with a limited transmitter footprint on the surface.

58 GEOSCIENCES↗

Observation of a THz-sub-THz spontaneous coherent undulator radiation driven by a low energy electron beam from a thermionic RF electron gun

In this work, we report observations of an intense, multi-band, sub-THz and THz radiation extracted from a similar to 2-3 MeV electron beam with a flat transverse profile propagating in an oversized rectangular waveguide placed into a 3.25 mm gap of a planar undulator having 1.3 cm period and similar to 20 cm length. Radiation outcoupling is accomplished using a horn antenna and a miniature permanent in-vacuum magnet separating the mm-sub-mm-waves and electron beam. A table-top experiment utilizes a radio frequency thermionic electron gun delivering a thousand momentum-chirped microbunches per macropulse and an alpha-magnet producing microbunches of a sub-mm length. Total radiated energy of a sub-millijoule per a microsecond radio frequency macropulse is demonstrated with flux more than ten micro-Joules per centimeter squared. With 1 THz filter the energy measured is about 1 microjoule and flux of a few micro-Joules per centimeter squared.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nonlinear dynamics of proton beams with hollow electron lens in the CERN high-luminosity LHC

The design stored beam energy in the CERN high-luminosity large hadron collider (HL-LHC) upgrade is about 700 MJ, with about 36 MJ in the beam tails, according to estimates based on scaling considerations from measurements at the LHC. Such a large amount of stored energy in the beam tails poses serious challenges on its control and safe disposal. In particular, orbit jitters can cause significant losses on primary collimators, which can lead to accidental beam dumps, magnet quenches, or even permanent damage to collimators and other accelerator elements. Thus, active control of the diffusion speed of halo particles is necessary and the use of hollow electron lenses (HELs) represents the most promising approach to handle overpopulated tails at the HL-LHC. HEL is a very powerful and advanced tool that can be used for controlled depletion of beam tails, thus enhancing the performance of beam halo collimation. For these reasons, HELs have been recently included in the HL-LHC baseline. In this paper, we present detailed beam dynamics calculations performed with the goal of defining HEL specifications and operational scenarios for HL-LHC. The prospects for effective halo control in HL-LHC are presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

RESONANT MATCHING SECTION FOR CEBAF ENERGY UPGRADE

Thomas Jefferson National Accelerator Facility (Jeffer- son Lab) currently studies the feasibility of upgrading its energy to 22 GeV. It considers addition of six more linac passes. The highest energy passes will share two new arcs designed using the Fixed-Field Alternating Gradient (FFA) technology. The FFA arcs are built using permanent combined-function magnets. They will be connected to the linacs through transition sections that will match the optics of all six passes to the linacs. With the high number of con- straints and the limited space available, we are investigating a parametric resonance technique to match the optics quasi- independently at each energy. A resonance is excited at each individual energy to selectively control its optics. The reso- nant dipole and quadrupole kick harmonics are imposed for all energies simultaneously using Panofsky corrector mag- nets placed throughout the FFA arcs. This paper presents the current progress on that transition section design

Deitrick, K.↗

Design Enhancements for the SNS RFQ Coaxial Coupler

The H⁻ ion linear accelerator at the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory operates with reliability that routinely surpasses 90% during scheduled beam operation. With the ambitious goal of eventually achieving at least 95% availability, several upgrade and improvement projects are ongoing. One such project is the modification of the coaxial couplers that transfer radio frequency (RF) power to the accelerator’s Radio Frequency Quadrupole (RFQ). The proposed modification utilizes stub sections and capacitive coupling to construct a physically separable assembly with DC isolation. With a separated coupler assembly, the section that includes the magnetic coupling loop can be permanently mounted to the RFQ which would eliminate the need to re-adjust the couplers after maintenance activities, upgrades, and repairs. Additionally, the modified design would provide increased multipaction suppression with DC biasing and potentially lower thermal gradients across the device. This paper presents the design and simulation results of the project.

Toby, George↗

Model-driven prediction for accelerator magnet diagnostics to improve operation reliability

Reliability is one of the most critical metrics for accelerator operation, especially in user facilities. To reduce costly facility downtime and provide an operational environment where system performance can be reliably predicted in support of scientific studies, we are developing a model-driven approach for prediction and anomaly detection. Here, in this study, we present the application of a model-driven method that employs a linear regression model to predict the future temperature, in real time, of accelerator magnets at the NSLS-II light source. This approach enables proactive identification of magnet-heating issues, facilitating magnet flushing prior to the occurrence of permanent damage without interrupting machine operation. The implementation of this method in the NSLS-II control room is described and the analysis of the online results is presented. The results demonstrate the model’s effectiveness in providing early alerts to engineers and improving the reliability of accelerator operations.

36 MATERIALS SCIENCE↗

The System for on-Axis Neutrino Detection at the DUNE Near Detector complex

The Deep Underground Neutrino Experiment Near Detector complex aims at constraining the systematic uncertainties and deconvolving the neutrino beam flux and cross-section models. The System for on-Axis Neutrino Detection (SAND) is the Near Detector component permanently on-axis. SAND is based on the 0.6 T superconducting magnet and electromagnetic calorimeter previously used in the KLOE experiment. The 40 m3 magnetic volume will be filled with an active target/tracker system. One considered option foresees an upstream liquid Argon active target (about 1.5 t) and a Straw Tube Tracker (about 5 t). In this talk the design of SAND will be described and its performances discussed in view of the SAND primary goals, namely the beam monitoring and neutrino flux measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Non-monotonic magnetic anisotropy behavior as a function of adsorbate coverage in Fe ultrathin films near the spin reorientation transition

Carbon monoxide (CO) adsorption on ultrathin fcc Fe films is known to result in the rotation of magnetization from out-of-plane to in-plane. By imaging in real time the magnetic domain structure of perpendicularly magnetized Fe/(2 ML)Ni/Cu(100) films during exposure to CO, we demonstrate that the effect of adsorption on the magnetic properties occurs in two distinct stages. Initially, when CO bonds preferentially on bridge sites, perpendicular magnetic anisotropy is enhanced. Later, when on-top adsorption dominates, magnetization rotates towards in-plane in agreement with previous studies. This CO-induced spin reorientation transition (SRT) is not reversible by annealing, as CO desorption would require high temperature cycles which yield permanent structural changes in the metal films. This study demonstrates the existence of a novel non-monotonic behavior of the magnetic anisotropy as a function of adsorbate coverage. The influence of CO on ultrathin film magnetism in real time near critical points, where the anisotropy balance is extremely sensitive to small variations, reveals the previously elusive complexity of this adsorbate induced SRT.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Protein Data Bank: A Comprehensive Review of 3D Structure Holdings and Worldwide Utilization by Researchers, Educators, and Students

The Research Collaboratory for Structural Bioinformatics Protein Data Bank (RCSB PDB), funded by the United States National Science Foundation, National Institutes of Health, and Department of Energy, supports structural biologists and Protein Data Bank (PDB) data users around the world. The RCSB PDB, a founding member of the Worldwide Protein Data Bank (wwPDB) partnership, serves as the US data center for the global PDB archive housing experimentally-determined three-dimensional (3D) structure data for biological macromolecules. As the wwPDB-designated Archive Keeper, RCSB PDB is also responsible for the security of PDB data and weekly update of the archive. RCSB PDB serves tens of thousands of data depositors (using macromolecular crystallography, nuclear magnetic resonance spectroscopy, electron microscopy, and micro-electron diffraction) annually working on all permanently inhabited continents. RCSB PDB makes PDB data available from its research-focused web portal at no charge and without usage restrictions to many millions of PDB data consumers around the globe. It also provides educators, students, and the general public with an introduction to the PDB and related training materials through its outreach and education-focused web portal. This review article describes growth of the PDB, examines evolution of experimental methods for structure determination viewed through the lens of the PDB archive, and provides a detailed accounting of PDB archival holdings and their utilization by researchers, educators, and students worldwide.

59 BASIC BIOLOGICAL SCIENCES↗

Conceptual Design of a HTS Dipole Insert Based on Bi2212 Rutherford Cable

The U.S. Magnet Development Program (US-MDP) is aimed at developing high-field accelerator magnets with magnetic fields beyond the limits of Nb 3 Sn technology. Recent progress with composite wires and Rutherford cables based on the first generation high-temperature superconductor Bi 2 Sr 2 CaCu 2 O 8-x (Bi2212) allows considering them for this purpose. However, Bi2212 wires and cables are sensitive to transverse stresses and strains, which are large in high-field accelerator magnets. This requires magnet designs with stress management concepts to control azimuthal and radial strains in the coil windings and prevent the degradation of the current carrying capability of Bi2212 conductor or even its permanent damage. This paper describes a novel stress management approach, which was developed at Fermilab for high-field large-aperture Nb 3 Sn accelerator magnets, and is now being applied to high-field dipole inserts based on Bi2212 Rutherford cables. The insert conceptual design and main parameters, including the superconducting wire and cable, as well as the coil stress management structure, key technological steps and approaches, test configurations and their target parameters, are presented and discussed.

43 PARTICLE ACCELERATORS↗

The SAND detector at the DUNE near site

DUNE is a next-generation long baseline experiment for neutrino oscillation physics. The NearDetector complex aims at constraining the systematic uncertainties to ensure high precisionmeasurements of neutrino oscillation parameters. The SAND apparatus is one of the threecomponents of the Near Detector complex permanently located on-axis to monitor the neutrinobeam stability, measure its flux and perform precise neutrino physics. SAND exploits a 0.6 Tsuperconducting magnet coupled with an electromagnetic calorimeter made of lead scintillating fibers. The inner magnetized volume is provided with a novel LAr detector and a low-density Straw Tube Target tracker. In this article the major components of the SAND apparatus and their role in the measurements of (anti)neutrinos interactions are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Acid-base bifunctional porous liquids

Basic solutions are essential for gas-involved catalytic transformations, yet their ultralow free volume limits gas solubility and diffusivity. Engineering permanent porosity in such reactive liquids has remained a longstanding challenge. Here, we introduce a surface-sacrifice strategy that incorporates Brønsted-acidic zeolite nanocrystals into strong organic bases to create permanently porous reactive liquids. Stereochemically controlled acid–base neutralization at the external zeolite surface forms a thin ionic solvation shell that stabilizes the dispersion while fully preserving the internal microporosity and crystallinity of the zeolite framework. The resulting basic media exhibit persistent microporosity, confirmed by inert-gas sorption, 129Xe nuclear magnetic resonance, neutron scattering, and theoretical simulations. These porous liquids show significantly enhanced catalytic performance in CO2 conversion and hydrogenation reactions. The coexisting acidic and basic sites further enable antagonistic cascade catalysis within a single liquid phase. This surface-sacrifice approach provides a general route to introduce permanent porosity into reactive media, enabling boosted gas transformations.

Qiu, Liqi [University of Tennessee, Knoxville (UTK↗

Observation of High-Energy Electrons Precipitated by NWC Transmitter From PROBA-V Low-Earth Orbit Satellite

The very low-frequency transmitter in the Northwest Cape of Australia (NWC) has previously been observed to pitch-angle scatter electrons with energies from 30–400 keV, creating enhanced fluxes measured by low-Earth orbiting (LEO) satellites. Here we use observations from the Energetic Particle Telescope on PROBA-V. We compare the measured flux, as a function of local magnetic field strength, when the NWC transmitter is “on” versus “off,” and find enhanced fluxes only when NWC is “on” and located on the nightside. The enhanced fluxes occur in the population gradually transitioning from “permanently trapped” to “quasi-trapped.” We show that electrons up to 800 keV, substantially higher energy than previously studied, are scattered by resonant interactions with NWC to produce enhanced fluxes. The enhanced fluxes appear at multiple L-shells for each energy channel, consistent with resonance conditions at distinct wave normal angles, that indicate ducted interactions at L < 1.55 and unducted interactions at L > 1.65.

79 ASTRONOMY AND ASTROPHYSICS↗

Time Projection Chambers instrumented with resistive MicroMegas for the SAND near detector of DUNE

The Deep Underground Neutrino Experiment (DUNE) is a next-generation long-baseline neutrino accelerator experiment aiming for precise measurements of the neutrino oscillation parameters. DUNE will include a near detector complex regrouping three different detectors among which SAND (System for on-Axis Neutrino Detection) that will be the only one permanently on the neutrino beam axis in charge of monitoring in detail the emitted neutrino beam and its stability through time, a crucial characteristic to realize accurate oscillation measurements at the percent level. SAND will reuse the superconducting magnet and the electromagnetic calorimeter of the KLOE experiment. We will describe in the following the proposal of using, as inner tracker of SAND, a large 3D matrix of 1.5cm side scintillator cubes (3DST) surrounded by 3 gaseous Time Projection Chambers. This setup allows to realize accurate beam monitoring combining the 3DST unprecedented capability of neutron detection and energy measurement with the high precision momentum resolution for charged particles offered by the TPCs. The proposed TPC design allows to reach spatial resolutions of a few hundreds of micrometers using 1 cm pads by deploying the resistive MicroMegas technology for the charge readout.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A survey of nuclear quadrupole deformation in order to estimate the nuclear MQM and its relative contribution to the atomic EDM: Searching for the best candidate to focus on an atomic EDM measurement: A nuclear physics perspective

Abstract Measurement of a non-zero permanent electric dipole moment (EDM) in fundamental particles, such as in an electron or a neutron, or in nuclei or atoms, can help us gain a handle on the sources of Charge-Parity (CP) violation, both in the Standard Model (SM) and beyond. The nuclear magnetic quadrupole moment (MQM), the central topic of this work, is also CP, P, and T violating. Nucleons and nuclei have a non-zero MQM from sources within the SM, but the nuclear MQM is dramatically enhanced if the nuclei are structurally quadrupole deformed. Multiple sources contribute to an atomic EDM namely: (i) nuclear EDM through its Schiff moment, which is enhanced by nuclear octupole deformation, (ii) CP violating interactions between the electrons and the nuclei, and (iii) the nuclear MQM that contributes to the atomic EDM in atoms with an unpaired valence electron. Our survey of nuclear quadrupole deformation identified 48 isotopes as ideal systems in which to search for a CP violating EDM via their enhanced nuclear MQM. Of these candidates, $$^{223,225}$$ 223 , 225 Fr, $$^{223}$$ 223 Ra, $$^{223,225,227}$$ 223 , 225 , 227 Ac, $$^{229}$$ 229 Th, and $$^{229}$$ 229 Pa also have maximally enhanced nuclear Schiff moment contribution due to their octupole deformation. Laser cooling of the isotopes of Fr and Ra, among a few others, has already been demonstrated, making $$^{223,225}$$ 223 , 225 Fr and $$^{223}$$ 223 Ra some of the best systems in which to measure an EDM.

MohanMurthy, Prajwal↗