Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Performance tests”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

2010 Honda Civic Hybrid UltraBattery Conversion 5577 - Hybrid Electric Vehicle Battery Test Results

The U.S. Department of Energy Advanced Vehicle Testing Activity Program consists of vehicle, battery, and infrastructure testing on advanced technology related to transportation. The activity includes tests on hybrid electric vehicles (HEVs), including testing the HEV batteries when both the vehicles and batteries are new and at the conclusion of on-road fleet testing. This report documents battery testing performed for the 2010 Honda Civic HEV UltraBattery Conversion (VIN JHMFA3F24AS005577). Battery testing was performed by the Electric Transportation Engineering Corporation dba ECOtality North America. The Idaho National Laboratory and ECOtality North America collaborate on the AVTA for the Vehicle Technologies Program of the DOE.

33 ADVANCED PROPULSION SYSTEMS↗

Biomass Cofiring With Precombustion Carbon Capture Baseline Testing at UND EERC

The project was to perform testing that establishes a baseline of precombustion carbon capture performance when combined with coal- and biomass-derived syngas. Goals of the project were to generate syngas from a matrix of coal types, biomass types, and varied fuel concentrations. Solvent performance and contaminant accumulation within the acid gas separation system (AGSS) were examined.

acid gas separation↗

Versatile compact heater design for in situ nano-tomography by transmission X-ray microscopy

A versatile, compact heater designed at National Synchrotron Light Source-II for in situ X-ray nano-imaging in a full-field transmission X-ray microscope is presented. Heater design for nano-imaging is challenging, combining tight spatial constraints with stringent design requirements for the temperature range and stability. Finite-element modeling and analytical calculations were used to determine the heater design parameters. Performance tests demonstrated reliable and stable performance, including maintaining the exterior casing close to room temperature while the heater is operating at above 1100°C, a homogenous heating zone and small temperature fluctuations. Two scientific experiments are presented to demonstrate the heater capabilities: (i) in situ 3D nano-tomography including a study of metal dealloying in a liquid molten salt extreme environment, and (ii) a study of pore formation in icosahedral quasicrystals. The progression of structural changes in both studies were clearly resolved in 3D, showing that the new heater enables powerful capabilities to directly visualize and quantify 3D morphological evolution of materials under real conditions by X-ray nano-imaging at elevated temperature during synthesis, fabrication and operation processes. This heater design concept can be applied to other applications where a precise, compact heater design is required.

36 MATERIALS SCIENCE↗

Improvements to PHISICS/RELAP5-3D{sup C} Capabilities for Simulating HTGRs

Accurate, high-resolution full core simulations of prismatic high temperature reactors for burnup and transient analysis remain a challenge. The cores are geometrically large, but some features are quite small (tri-structural isotropic (TRISO) particles, burnable poison pellets). The treatment of both neutron scattering in graphite and resonance capture are complex and not adequately captured using the methods traditionally used in High Temperature Gas-cooled Reactors (HTGR) and commonly used in Light Water Reactors (LWR). For transient analysis, temperature feedback is a function of the TRISO fuel form, but full core models cannot resolve phenomena at this scale without averaging over space and energy. For burnup calculations, a second level of heterogeneity must be resolved to capture the local effects of fuel and burnable poisons, while accurately propagating their effects through and between blocks. The HTGR Methods and Simulation group has been utilizing the INL-developed PHISICS/RELAP5-3D{sup C} (P/R), code suite for participation in the Organization for Economic Cooperation and Development (OECD) Modular High Temperature Gas Cooled Reactor (MHTGR) Benchmark, funded by the US Department of Energy (DOE) under the Advanced Reactor Technologies (ART) program. The MHTGR-350 benchmark consists of several lattice, steady-state and transient exercises, and the P/R code has been successfully applied to most of the cases defined. In addition to this code-to-code verification activity, it is planned that P/R will be validated using data from several Loss of Forced Cooling (LOFC) tests performed at the High Temperature Test Reactor (HTTR) in a joint effort with Japan Atomic Energy Agency (JAEA) under the Civil Nuclear Energy Working Group (CNWG) project. These verification and validation simulations will identify code and model discrepancies, sensitivities, and establish the current state-of-the-art in HTGR simulation. The Department of Astronautical, Electrical and Energy Engineering (DIAEE), 'Sapienza' University has been involved in the development of P/R since 2014 through various graduate and PhD student projects. In the framework of this collaboration the P/R optimization for application on the OECD MHTGR-350 and HTTR models will be carried out.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Wind Turbine Safety and Function Test Report for the Mariah Windspire Wind Turbine

This test was conducted as part of the U.S. Department of Energy's (DOE) Independent Testing project. This project was established to help reduce the barriers to wind energy expansion by providing independent testing results for small wind turbines (SWT). In total, five turbines were tested at the National Wind Technology Center (NWTC) as a part of this project. Safety and function testing is one of up to five tests performed on the turbines, including power performance, duration, noise, and power-quality tests. NWTC testing results provide manufacturers with reports that may be used to meet part of small wind turbine certification requirements. The test equipment includes a Mariah Windspire wind turbine mounted on a monopole tower. L&E Machine manufactured the turbine in the United States. The inverter was manufactured separately by Technology Driven Products in the United States. The system was installed by the NWTC site operations group with guidance and assistance from Mariah Power.

17 WIND ENERGY↗

ORNL Package Testing Program Overview

When transporting radioactive or hazardous materials, safety and security are top priorities. Packaging and transportation regulations require reliable evidence that containers have passed rigorous performance tests to ensure that the public and the environment are protected from the hazardous nature of the cargo. Because of its long history in energy and security research, Oak Ridge National Laboratory (ORNL) has needed to ship hazardous packages for the past 65 years. Since the 1940s, ORNL has made significant contributions to transportation regulations and has been at the forefront of regulatory testing development. Today, ORNL is a leader in standards development and testing of designs of radioactive material packages. ORNL plays a critical role in ensuring the safe transportation of radioactive materials across the United States by executing rigorous testing campaigns of packages that contain radioactive materials. Early testing activities focused on supporting the development of transportation regulations established by both the International Atomic Energy Agency (IAEA) and the United States. Currently, all package testing activities are performed under the Package Testing Program (PTP) at the Package Evaluation Facility (PEF) located at the National Transportation Research Center (NTRC), which is about 10 miles from the main ORNL campus. The PTP develops and evaluates testing solutions, ensuring that they are safe efficient, and in compliance with regulatory requirements. The vision for the PTP is to be a world-class leader in the evaluation and testing of radioactive and hazardous material packages. The key elements necessary to fulfill this mission are an experienced and professional staff; state-of-the-art facilities, equipment, and instrumentation; and completion of challenging programs and projects important to package transportation. Collaborations with other internal and external organizations play a significant role in building stronger teams and achieving this vision. By adhering to and advancing regulatory standards, ORNL’s PTP supports development of safe and compliant packaging, safeguarding the transportation process from potential risks associated with radioactive material logistics.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

PIPII cryoplant non thermal cycling updates

The Proton Improvement Plan-II (PIP-II) is a crucial upgrade to the Fermilab accelerator complex, featuring a new 800-MeV Superconducting Radio-Frequency (SRF) linear accelerator (LINAC) with 23 cryomodules operating at 2K. The LINAC thermohydraulic conditions are satisfied by the cryogenic subsystems: Cryogenic Distribution System (CDS), a helium refrigerator cold box (CB), a warm compression station (WCS) and a helium recovery system (RSYS). The accelerator has a strict requirement of non-thermal cycling of the LINAC cryomodules during planned and unplanned subsystem outages. This paper presents an integrated operating modes analysis of the of the LINAC/CDS thermohydraulic loads satisfied by the CB/WCS cooling system supported by the RSYS inventory management system. The study is based on latest cryoplant and CDS engineering deliverables, as well as the recent performance data from single cryomodule qualification tests performed at the Fermilab PIP-II Injector Test test s tand. The study evaluates both normal and abnormal operating modes, with a focus on identifying integrated scenarios that put subsystems components under stress. The conclusions of this study will help build redundancy to reduce the risk of thermal cycles during planned and unplanned subsystem outages.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Thermocouple Testing in Support of the AGR-5/6/7 Experiment

This report documents thermocouple testing performed in IRC Lab C-15 over a period of seven years. This testing supported selection and characterization of the thermocouple set used in the AGR-5/6/7 experiment. The following summary was taken directly from the report. Temperature measurement is a challenging aspect of very high temperature irradiation experiments because commonly used high-temperature commercial thermocouples such as platinum-rhodium (Types S, R, and B) and tungsten-rhenium (Type C), suffer dramatic drift because of neutron-induced transmutation. As a result, these types of thermocouples, which are used routinely for industrial temperature measurements outside of reactors, are used only in very special circumstances for reactor experiments. Conversely, because of their low neutron cross-sections, Type N thermocouples are affected to only a limited extent by neutron irradiation. However, the use of these nickel-based thermocouples is limited when the temperature exceeds 1050°C due to drift arising from minor alloying elements migrating from the thermocouple's metal sheath to the thermoelements. This change in the composition of the thermo-elements results in significant decalibration of the signal. The issues described above were recognized during the early planning stages of the final AGR experiment (designated AGR-5/6/7), and a thermocouple furnace testing program was performed over a seven-year period (2014-2019, 2021) to first select and then characterize the best thermocouple set for the high temperature regions of the AGR-5/6/7 irradiation experiment. The calculated temperature range of the AGR-5/6/7 experiment was 600–1500°C. For temperatures below 1000°C standard Type N thermocouples were deemed adequate. The furnace testing campaign identified two thermocouple types suitable for measuring temperatures above 1000°C, a Mo/Nb thermocouple developed at INL called HTIR-TC, and a Type N thermocouple developed by Cambridge University (called herein Cambridge Type N), which featured a custom high nickel alloy sheath. One of the original goals of the furnace testing program was to identify a thermocouple capable of low drift operation near the peak temperature expected in AGR-5/6/7, i.e., about 1400°C. The HTIR-TC design appeared promising in this regard, however a manufacturing difficulty proved to be a barrier and instead the furnace testing focused on drift performance at 1250°C. The manufacturing difficulty was that the Nb sheaths of the HTIR-TCs experienced extreme embrittlement when heat treated at 1600°C or greater. Heat treatment is needed to stabilize the emf output of this TC type, and the higher the heat treatment temperature the higher the peak temperature of stable operation. Because of the sheath embrittlement the heat treatment temperature had to be lowered to 1450°C resulting in a stable operating temperature of about 1250°C. One of the successes of the furnace testing program was identification of a shortcoming in the heat treatment procedure that had been traditionally used in the production of HTIR-TCs. The shortcoming was that the entire heated length of the HTIR-TC sensor was not being heat treated, but rather only the part of the sensor expected to experience temperatures above 1000°C. The problem manifested itself when the thermocouples were removed from the heat treat furnace and placed in another furnace with a different geometry, their indicated temperatures would be widely scattered, but mostly in the negative direction. The solution was to heat treat the entire heated length of the sensor. Since the deepest immersion depth in the AGR-5/6/7 experiment was about 40 inches, a heat treatment length of 48 inches was used. After this change was implemented, thermocouples which were moved into a new environment with a different temperature profile (i.e., a different furnace), produced accurate temperature measurements. Although assembly of the AGR-5/6/7 experiment was completed in September of 2017 (and irradiation begun in 2018), furnace testing of thermocouples continued in 2018 and 2019. The main purpose of this testing was to establish very long-term drift characteristics of the HTIR and Cambridge Type N thermocouples installed in the experiment. Representative thermocouples from the same lots as those installed in the AGR-5/6/7 experiment were used. Additionally, thermocouples of different designs, (particularly variations on the HTIR-TC design) were "piggy-backed" on this testing program to provide insights for instrumenting future very high temperature irradiation experiments. This two-year testing program demonstrated that HTIR-TCs and Cambridge Type N TCs could operate at 1250°C for up to 10,000 hrs (and in some cases longer) while experiencing negative drifts on the order of 2-4°C/1000 hrs. This performance was considered acceptable given the extreme operating environment the sensors faced.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantitative Approach to Failure Mode and Effect Analysis for Linear Accelerator Quality Assurance

Purpose: To determine clinic-specific linear accelerator quality assurance (QA) TG-142 test frequencies, to maximize physicist time efficiency and patient treatment quality. Methods and Materials: A novel quantitative approach to failure mode and effect analysis is proposed. Nine linear accelerator-years of QA records provided data on failure occurrence rates. The severity of test failure was modeled by introducing corresponding errors into head and neck intensity modulated radiation therapy treatment plans. The relative risk of daily linear accelerator QA was calculated as a function of frequency of test performance. Results: Although the failure severity was greatest for daily imaging QA (imaging vs treatment isocenter and imaging positioning/repositioning), the failure occurrence rate was greatest for output and laser testing. The composite ranking results suggest that performing output and lasers tests daily, imaging versus treatment isocenter and imaging positioning/repositioning tests weekly, and optical distance indicator and jaws versus light field tests biweekly would be acceptable for non-stereotactic radiosurgery/stereotactic body radiation therapy linear accelerators. Conclusions: Failure mode and effect analysis is a useful tool to determine the relative importance of QA tests from TG-142. Because there are practical time limitations on how many QA tests can be performed, this analysis highlights which tests are the most important and suggests the frequency of testing based on each test's risk priority number.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Final Report Start-Up and Commissioning Tests on the DuraMelter 1200 HLW Pilot Melter System Using AZ-101 HLW Simulants

This document provides the final report on data and results obtained from commissioning tests performed on the one-third scale DuraMelter{trademark} 1200 (DM 1200) HLW Pilot Melter system that has been installed at VSL with an integrated prototypical off-gas treatment system. That system has replaced the DM1000 system that was used for HLW throughput testing during Part BI [1]. Both melters have similar melt surface areas (1.2 m{sup 2}) but the DM1200 is prototypical of the present RPP-WTP HLW melter design whereas the DM1000 was not. These tests were performed under a corresponding RPP-WTP Test Specification and associated Test Plan. This report is a followup to the previously issued Preliminary Data Summary Report. The DM1200 system will be used for testing and confirmation of basic design, operability, flow sheet, and process control assumptions as well as for support of waste form qualification and permitting. This will include data on processing rates, off-gas treatment system performance, recycle stream compositions, as well as process operability and reliability. Consequently, this system is a key component of the overall HLW vitrification development strategy. The results presented in this report are from the initial series of short-duration tests that were conducted to support the start-up and commissioning of this system prior to conducting the main body of development tests that have been planned for this system. These tests were directed primarily at system 'debugging,' operator training, and procedure refinement. The AZ-101 waste simulant and glass composition that was used for previous testing was selected for these tests.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Next Generation Melter Testing for High Aluminum HLW Glasses (Final Report)

This Final Report describes the initial DuraMelter 100 (DM100) scale testing performed to support the development of next generation advanced joule-heated melters (NG AJHMs). The initial phase of testing investigated the impacts of plenum heaters and the partial drying of melter feed prior to its introduction into the melter. The tests demonstrate the overall impacts and benefits on processing characteristics such as increases in waste processing and glass production rates, and component volatility. The results also provide melting rates for sizing calculations and compatibility of feed and off-gas treatment systems. The tests were performed with a Hanford high level waste (HLW) composition previously processed on both the DM100 melter and the HLW Pilot Melter (DM1200). The simulated waste containing a high concentration of aluminum was originally specified by the Office of River Protection (ORP) for testing at VSL. This waste composition is representative of high-aluminum feeds that will be processed at the Hanford Tank Waste Treatment and Immobilization Plant (WTP) and that are expected to challenge waste loading and processing rate objectives. This works builds upon previous work performed at the Vitreous State Laboratory (VSL) of the Catholic University of America (CUA) for ORP to increase waste loadings and waste processing rates for high aluminum HLW waste streams by glass formulation optimization, bubbling, and modest increases in melt temperature. The present tests were conducted in response to the Task Plan WP-4.1.4.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Crystalline Silicotitanate ion exchange media long-term storage evaluation

Crystalline Silicotitanate a (CST) ion exchange media is produced in an engineered form, known as IONSIV™ IE-911. This material has been tested extensively for use in removing 137 Cs from Savannah River Site (SRS) and Hanford site tank waste. This inorganic material is highly selective for removing cesium ions, even in the presence of high concentrations of sodium and potassium ions and is tolerant of the harsh conditions of the varying tank chemistries. A batch of caustic washed IE-911 that had been produced by the supplier and received at SRS in 2001 was tested to verify that it was still in good condition after the extended storage. This testing involved standard batch contacts to measure the removal of Cs from simulated tank waste. This report describes the results of testing performed to verify that the IE-911 matches the performance of previous batches of this media. To confirm that the performance of IE-911 is similar to previous batches and that no degradation had occurred during storage, batch contact testing was performed using SRNL’s standard methodology using a non-radioactive SRS Average Waste Simulant composition utilized in previous studies. Batch contact kinetics testing was also conducted to determine cesium loading on this batch versus time. The cesium equilibrium loading isotherm in SRS simulant at 23°C was compared to ZAM isotherm model predictions and previous test results with IE-911 media. The measured and predicted distribution coefficients and cesium loading (“Q”) are shown in Table ES-1. The physical properties of the material were also determined, including density, moisture content, and particle size.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

IMPLEMENTING PRIMARY CREEP CALCULATIONS DURING STRESS CHANGES AND REVERSALS IN THE FUEL PERFORMANCE CODE FRAPCON-3

Recently, the creep models in FRAPCON-3.4 were used to model the creep tests performed in IFA-699 up through cycle 4. IFA-699 is an instrumented test rig in the Halden Boiling Water Reactor that is being used to perform in-reactor creep experiments under changing stress conditions. The cladding creep tests in IFA-699 were on four fresh fuel segments with Zircaloy-4, E110, M-MDA, and M5™ cladding. These fuel segments were loaded in a test rig and placed in a PWR loop and operated under PWR conditions. Each of the test fuel rods were connected to gas lines in order to apply tensile and compressive stresses to the cladding. Diameters of the cladding were measured by diameter gages at several intervals to measure the creep behavior of the cladding as a function of time. The creep tests were performed at a temperature of around 360°C and fast neutron flux of 1.8 to 2.4×1017 n/m²-s (depends on specimen location). During the four cycles of operation, hoop stresses of -75, -50, +30, and +110 MPa were applied to the specimens. In addition to providing assessment of the FRAPCON-3.4 creep modeling, the creep model comparisons were also used to provide insight into the nature of primary creep following stress changes, whether creep behavior is symmetric under tensile and compressive loading, and the effect of fast fluence on creep rate. It was determined that creep strain should be calculated as a function of effective stress rather than hoop stress. This accounts for the observed difference between creep under compressive and tensile stress for the same hoop stress. It was also determined that the primary creep changes in proportion to the change in stress following stress change or stress reversal. Finally, it was observed that the irradiation creep rate decreases somewhat with increasing fluence. The creep model in FRAPCON-3.4 has already been developed to be a function of effective stress and includes a term that decreases the irradiation creep rate with increasing fluence. A new mathematical formulation has been developed that is suitable for a fuel performance code to calculate the primary creep strain under conditions of changing stress and stress reversal. The creep model in FRAPCON-3.4 and the formulation for calculating primary creep under changing stress conditions will be described in this paper. Comparisons to data will also be provided.

Geelhood, Kenneth J.↗

Crush Testing at Oak Ridge National Laboratory

The dynamic crush test is required in the certification testing of some small Type B transportation packages. International Atomic Energy Agency regulations state that the test article must be subjected to a dynamic crush test by positioning the specimen on the target so as to suffer maximum damage. Oak Ridge National Laboratory (ORNL) Transportation Technologies Group performs testing of Type B transportation packages, including the crush test, at the National Transportation Research Center in Knoxville, Tennessee (United States). This paper documents ORNL s experiences performing crush tests on several different Type B packages.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Development of special rotor for centrifugal separation of isotopes in solid pure metals

A prototype rotor with two grooves for the multistage centrifugal isotope separation in solid state was developed to test a new idea. This idea is based on the sedimentation of constitutional atoms in solid. In the performance test using indium specimen, it is verified that the developed rotor can receive all injected molten-indium droplets from an automatic raw-material feeding system even at the high rotational speed of 97 000 rpm without the loss of rotational stability, and the received indium specimens can be transferred in/between two grooves through the plastic flow under the influence of strong centrifugal force even in the solid state. The isotope ratio of centrifuged indium specimens was analyzed employing the secondary ion mass spectrometry, and it is confirmed that intended isotope separation by the centrifugation is realized in the solid state. The developed rotor can be used to perform the isotope separation on at least solid metals under the conditions of up to 400 deg. C in specimen temperature and 0.4x10{sup 6}g in centrifugal force field.

07 ISOTOPE AND RADIATION SOURCES↗