Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Performance Evaluation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Performance Evaluation of an Intelligent Sensor Platform for Radiation Monitoring Applications

Accurate, rugged, and reliable radiation detection systems are important for area and environmental monitoring applications. The desire for spectroscopic capability has increased in monitoring aspects of the nuclear fuel cycle to provide fast characterization of the radiation profile of a situation, such as the planned or unplanned release of material. The reduction or elimination of having to conduct sampling for laboratory analysis can result in significant cost savings for an industry, government agency, or regulatory body. A new system, comprised of a NaI:Tl scintillator and a G-M tube, has been designed and tested, taking into account the following end-user requirements: ease-of-use, capability to network and supervise multiple units, compact form factor, low power consumption, versatility, and stability. The detector sizes were selected to accommodate a dose rate up to 1 Sv/hr. Several algorithms and analysis routines have been developed to incorporate these key needs without sacrificing on accuracy, dynamic range, nuclide identification, and sensitivity. This presentation will introduce the major hardware and software components of the platform, as well as the user interface and data analysis workflow. Key features of the hardware include an environmentally robust housing, low power signal processing electronics, patented LED-based gain stabilization, and an embedded processor for unattended instrument management and data analysis. New and improved algorithms for determining scintillator gamma dose rates, total integrated dose, and nuclide identification will be introduced. The two detector elements were modeled with MCNP and validated experimentally. The results of the radiological testing shall be presented including energy resolution, throughput, dose response, and minimum detectable activities. The dose response has been evaluated in simulations and with measurements to ensure accurate response with respect to energy spectrum of the dose field and direction of the incident radiation. Spectroscopy evaluations, such as nuclide detection probability and false alarm rates, were performed and comparisons to existing algorithms shall also be presented. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and performance evaluation of a wideband FM spread-spectrum multiple-access system

The system described performs the tracking and communications functions of a tracking and data relay satellite system (TDRS). The spread-spectrum signal format is achieved through wide deviation FM by a sinusoidal subcarrier unique to each multiple-access user. A compound phase-locked loop tracks carrier and subcarrier and demodulates data and ranging signals. Design parameters of user and ground terminals for TDRS are given. Acquisition procedures are described. Performance analyses are presented including the effects of noise, RFI, multipath and other users.

Wachsman, R. H.↗

Flat-plate collector performance evaluation. The case for a solar simulation approach

A method is proposed for determining the performance of flat-plate solar collector using a simulated sun. Collector test variables that will help establish the basis for the indoor test facility at the Lewis Research Center are discussed. The use of the indoor testing should permit a standard test for the convenient and accurate determination of collector performance. Preliminary test results are reported as an example of the type of collector performance data to be expected from the simulation approach.

Simon, F. F.↗

Performance Evaluation of Titanium Ion Optics for the NASA 30 cm Ion Thruster

The results of performance tests with titanium ion optics were presented and compared to those of molybdenum ion optics. Both titanium and molybdenum ion optics were initially operated until ion optics performance parameters achieved steady state values. Afterwards, performance characterizations were conducted. This permitted proper performance comparisons of titanium and molybdenum ion optics. Ion optics' performance A,as characterized over a broad thruster input power range of 0.5 to 3.0 kW. All performance parameters for titanium ion optics of achieved steady state values after processing 1200 gm of propellant. Molybdenum ion optics exhibited no burn-in. Impingement-limited total voltages for titanium ion optics where up to 55 V greater than those for molybdenum ion optics. Comparisons of electron backstreaming limits as a function of peak beam current density for molybdenum and titanium ion optics demonstrated that titanium ion optics operated with a higher electron backstreaming limit than molybdenum ion optics for a given peak beam current density. Screen grid ion transparencies for titanium ion optics were as much as 3.8 percent lower than those for molybdenum ion optics. Beam divergence half-angles that enclosed 95 percent of the total beam current for titanium ion optics were within 1 to 3 deg. of those for molybdenum ion optics. All beam divergence thrust correction factors for titanium ion optics were within 1 percent of those with molybdenum ion optics.

Soulas, George C.↗

Experimental Studies and Energy Modeling for Evaluating Performance of Various Deep Wall Retrofits

The Pacific Northwest National Laboratory, Oak Ridge National Laboratory, and the University of Minnesota conducted a three-year, multipart study on residential retrofit wall assemblies. The project, which was funded by the U.S. Department of Energy’s Building Technology Office, aimed to compare a range of residential wall retrofit systems that prioritized affordability, durability, and energy savings potential. The research team identified, constructed, tested, simulated, and analyzed the feasibility and economics of 16 wall retrofit assemblies (14 test configurations and two baseline configurations) that can be applied to the exterior side of existing walls (either with or without the existing cladding). The 16 wall assemblies were installed in an in-situ laboratory environment, to evaluate the ease of construction and study the thermal and hygrothermal performance of the walls. This paper presents the methodology used to evaluate the thermal performance of the walls and discusses the energy modeling results of the study. The results from the experiments were used to calibrate a THERM model of each wall assembly, which was then applied to a whole building using the EnergyPlus 8.6 simulation engine. A residential prototype building was used to extrapolate whole-building energy savings in each U.S. climate zone. To capture the conditions of the largest number of homes in the United States, the most frequent building characteristics (e.g., attic insulation level, window specifications, foundation insulation, etc.) were extracted from ResStock data and applied to the prototype model. Results from the energy modeling showed that the climate zones with the highest potential for retrofit savings are those which are heating-dominated (i.e., Cold and Very Cold climate designations). In these climate zones, heating and cooling energy savings due to the wall retrofits alone ranged from 21.5% to 38.2%.

Nagda, Harshil↗

Dynamic Modelling and Performance Evaluation of a Chemisorption Heat Pump for Cold Climate

Space heating is a significant contributor to the energy consumption in residential buildings, especially in cold climates where electric-driven heat pumps lose the advantage of high efficiency and conventional gas-combustion furnaces have limited efficiency. Chemical adsorption (chemisorption) heat pumps (CSHP) have the potential for producing heating with high energy efficiency under cold operating conditions. A CSHP operates intermittently between desorption and adsorption modes, and their performance is affected by system design and transient system control. This study developed a dynamic model and used it to evaluate the daily system performance under different designs and controls, particularly the buffer tank size and the controlled minimum heating power. The simulation results revealed the effects of these parameters on the system performance and helped identify the optimal design and control for the highest coefficient of performance and heating capacity.

Yang, Zhiyao↗

Performance Evaluation of Large Aperture 'Polished Panel' Optical Receivers Based on Experimental Data

Recent interest in hybrid RF/Optical communications has led to the development and installation of a "polished-panel" optical receiver evaluation assembly on the 34-meter research antenna at Deep-Space Station 13 (DSS-13) at NASA's Goldstone Communications Complex. The test setup consists of a custom aluminum panel polished to optical smoothness, and a large-sensor CCD camera designed to image the point-spread function (PSF) generated by the polished aluminum panel. Extensive data has been obtained via realtime tracking and imaging of planets and stars at DSS-13. Both "on-source" and "off-source" data were recorded at various elevations, enabling the development of realistic simulations and analytic models to help determine the performance of future deep-space communications systems operating with on-off keying (OOK) or pulse-position-modulated (PPM) signaling formats with photon-counting detection, and compared with the ultimate quantum bound on detection performance for these modulations. Experimentally determined PSFs were scaled to provide realistic signal-distributions across a photon-counting detector array when a pulse is received, and uncoded as well as block-coded performance analyzed and evaluated for a well-known class of block codes.

on-off keying (OOK)↗

A portable Ka-band front-end test package for beam-waveguide antenna performance evaluation. Part 2: Tests on the antenna

In part one of this article, a description was given of a Ka-band test package developed to enable testing of the Deep Space Station (DDS) 13 34-m beam-waveguide (BWG) antenna at 32 GHz. Test results were given for the Ka-band test package in an on-the-ground test configuration. This article is a companion article concerned with Ka-band test results for the test package in an on-the-antenna test configuration. Included are Ka-band zenith noise-temperature values, tipping-curve data, and subreflector test results obtained at the Cassegrain focal point, as well as at the final BWG focal point (located in a subterranean pedestal room). Test results show that, through the use of the Ka-band test package, the BWG antenna performance was successfully evaluated at Ka-band. The Ka-band test package operated well in all of the different antenna test configurations.

Otoshi, T. Y.↗

A comparison of spectral decorrelation techniques and performance evaluation metrics for a wavelet-based, multispectral data compression algorithm

Future space-based, remote sensing systems will have data transmission requirements that exceed available downlinks necessitating the use of lossy compression techniques for multispectral data. In this paper, we describe several algorithms for lossy compression of multispectral data which combine spectral decorrelation techniques with an adaptive, wavelet-based, image compression algorithm to exploit both spectral and spatial correlation. We compare the performance of several different spectral decorrelation techniques including wavelet transformation in the spectral dimension. The performance of each technique is evaluated at compression ratios ranging from 4:1 to 16:1. Performance measures used are visual examination, conventional distortion measures, and multispectral classification results. We also introduce a family of distortion metrics that are designed to quantify and predict the effect of compression artifacts on multi spectral classification of the reconstructed data.

Matic, Roy M.↗

Performance evaluation of neutron noise analysis in detecting special nuclear materials

Reliable and rapid inspection techniques play a vital role in preventing illicit trafficking of special nuclear materials. Active interrogation systems using neutrons produced by portable, high-flux deuterium-deuterium or deuterium-tritium neutron generators are being actively developed as a secondary scanning tool for this purpose. In this study, a neutron noise analysis-based approach for detecting unshielded and shielded special nuclear materials by using a pulsed deuterium-tritium neutron generator was evaluated. Here, this approach analyzes the fluctuation of neutron counts. Its performance was quantified with regard to time-to-detection to achieve a minimum probability of detection of 99% and a probability of false alarm of less than 1% considering various amounts of special nuclear materials and different shielding configurations. It was demonstrated that this approach could detect 17 uranium slugs in 5 s given a neutron generator yield of 8.1 × 10 7 n/s. These slugs could be detected within a reasonable time frame (200 s) when they were shielded by 10.16 cm of high-density polyethylene. The results obtained using the neutron noise analysis approach were compared with those obtained using the commonly used differential die-away analysis technique, a sensitive technique for detecting the presence of fissile materials by utilizing the prompt fission neutrons produced when the source neutrons from a neutron generator are completely diminished. For example, the time to detect 2 unshielded uranium slugs was 2.1 s when using the differential die-away analysis technique; it increased to 93 s for the neutron noise analysis approach. Although the noise analysis-based approach exhibits an overall performance which is not as good as that of differential die-away, neutron noise provides an alternative method for effective detection of special nuclear materials.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characteristic performance evaluation of a photon counting Si strip detector for low dose spectral breast CT imaging

Purpose: The possible clinical applications which can be performed using a newly developed detector depend on the detector's characteristic performance in a number of metrics including the dynamic range, resolution, uniformity, and stability. The authors have evaluated a prototype energy resolved fast photon counting x-ray detector based on a silicon (Si) strip sensor used in an edge-on geometry with an application specific integrated circuit to record the number of x-rays and their energies at high flux and fast frame rates. The investigated detector was integrated with a dedicated breast spectral computed tomography (CT) system to make use of the detector's high spatial and energy resolution and low noise performance under conditions suitable for clinical breast imaging. The aim of this article is to investigate the intrinsic characteristics of the detector, in terms of maximum output count rate, spatial and energy resolution, and noise performance of the imaging system. Methods: The maximum output count rate was obtained with a 50 W x-ray tube with a maximum continuous output of 50 kVp at 1.0 mA. A{sup 109}Cd source, with a characteristic x-ray peak at 22 keV from Ag, was used to measure the energy resolution of the detector. The axial plane modulation transfer function (MTF) was measured using a 67 μm diameter tungsten wire. The two-dimensional (2D) noise power spectrum (NPS) was measured using flat field images and noise equivalent quanta (NEQ) were calculated using the MTF and NPS results. The image quality parameters were studied as a function of various radiation doses and reconstruction filters. The one-dimensional (1D) NPS was used to investigate the effect of electronic noise elimination by varying the minimum energy threshold. Results: A maximum output count rate of 100 million counts per second per square millimeter (cps/mm{sup 2}) has been obtained (1 million cps per 100 × 100 μm pixel). The electrical noise floor was less than 4 keV. The energy resolution measured with the 22 keV photons from a {sup 109}Cd source was less than 9%. A reduction of image noise was shown in all the spatial frequencies in 1D NPS as a result of the elimination of the electronic noise. The spatial resolution was measured just above 5 line pairs per mm (lp/mm) where 10% of MTF corresponded to 5.4 mm{sup −1}. The 2D NPS and NEQ shows a low noise floor and a linear dependence on dose. The reconstruction filter choice affected both of the MTF and NPS results, but had a weak effect on the NEQ. Conclusions: The prototype energy resolved photon counting Si strip detector can offer superior imaging performance for dedicated breast CT as compared to a conventional energy-integrating detector due to its high output count rate, high spatial and energy resolution, and low noise characteristics, which are essential characteristics for spectral breast CT imaging.

60 APPLIED LIFE SCIENCES↗

Daylighting performance evaluation of a bottom-up motorized roller shade

This paper presents an experimental and simulation study for quantifying the daylighting performance of bottom-up roller shades installed in office spaces. The bottom-up shade is a motorized roller shade that opens from top to bottom operating in the opposite direction of a conventional roller shade, so as to cover the bottom part of the window, while allowing daylight to enter from the top part of the window, reaching deeper into the room. A daylighting simulation model, validated with full-scale experiments, was developed in order to establish correlations between the shade position, outdoor illuminance and work plane illuminance for different outdoor conditions. Then, a shading control algorithm was developed for application in any location and orientation. The validated model was employed for a sensitivity analysis of the impact of shade optical properties and control on the potential energy savings due to the use of daylighting. The results showed that Daylight Autonomy for the bottom-up shade is 8-58% higher compared to a conventional roller shade, with a difference of 46% further away from the facade, where the use of electric lighting is needed most of the time. The potential reduction in energy consumption for lighting is 21-41%. (author)

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ATR LEU Monolithic Foil-Type Fuel with Integral Cladding Burnable Absorber – Neutronics Performance Evaluation

The Advanced Test Reactor (ATR), currently operating in the United States, is used for material testing at very high neutron fluxes. Powered with highly enriched uranium (HEU), the ATR has a maximum thermal power rating of 250 MWth. Because of the large test volumes located in high flux areas, the ATR is an ideal candidate for assessing the feasibility of converting HEU driven reactor cores to low-enriched uranium (LEU) cores. The burnable absorber - 10B, was added in the inner and outer plates to reduce the initial excess reactivity, and to improve the peak ratio of the inner/outer heat flux. The present work investigates the LEU Monolithic foil-type fuel with 10B Integral Cladding Burnable Absorber (ICBA) design and evaluates the subsequent neutronics operating effects of this proposed fuel designs. The proposed LEU fuel specification in this work is directly related to both the RERTR LEU Development Program and the Advanced Test Reactor (ATR) LEU Conversion Project at Idaho National Laboratory (INL).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Performance Evaluation and Optimization of Diesel Fuel Properties and Chemistry in an HCCI Engine

The nine CRC fuels for advanced combustion engines (FACE fuels) have been evaluated in a simple, premixed HCCI engine under varying conditions of fuel rate, air-fuel ratio, and intake temperature. Engine performance was found to vary mainly as a function of combustion phasing as affected by fuel cetane and engine control variables. The data was modeled using statistical techniques involving eigenvector representation of the fuel properties and engine control variables, to define engine response and allow optimization across the fuels for best fuel efficiency. In general, the independent manipulation of intake temperature and air-fuel ratio provided some opportunity for improving combustion efficiency of a specific fuel beyond the direct effect of targeting the optimum combustion phasing of the engine (near 5 CAD ATDC). High cetane fuels suffer performance loss due to easier ignition, resulting in lower intake temperatures, which increase HC and CO emissions and result in the need for more advanced combustion phasing. The FACE fuels also varied in T90 temperature and % aromatics, independent of cetane number. T90 temperature was found to have an effect on engine performance when combined with high centane, but % aromatics did not, when evaluated independently of cetane and T90.

33 ADVANCED PROPULSION SYSTEMS↗

Hanford Tank Farms Waste Feed Flow Loop Phase VI: PulseEcho System Performance Evaluation

This document presents the visual and ultrasonic PulseEcho critical velocity test results obtained from the System Performance test campaign that was completed in September 2012 with the Remote Sampler Demonstration (RSD)/Waste Feed Flow Loop cold-test platform located at the Monarch test facility in Pasco, Washington. This report is intended to complement and accompany the report that will be developed by WRPS on the design of the System Performance simulant matrix, the analysis of the slurry test sample concentration and particle size distribution (PSD) data, and the design and construction of the RSD/Waste Feed Flow Loop cold-test platform.

Denslow, Kayte M.↗