Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PLUGGING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Successful Occlusion of a Ruptured Aortic Aneurysm Using the Amplatzer Vascular Plug: A Technical Note

Ruptured abdominal aortic aneurysm is related with a 100% mortality rate if left untreated. Even with surgical intervention or endovascular repair, mortality is still extremely high. However, there are conditions in which neither open surgical aneurysm repair nor endovascular aneurysm repair can be considered a viable therapeutic option because of comorbidities or anatomic reasons. We report a case of successful endovascular treatment in a patient with ruptured abdominal aortic aneurysm by occluding the abdominal aneurysm using the Amplatzer Vascular Plug (AVP II).

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Utility of the Amplatzer Vascular Plug in Splenic Artery Embolization: A Comparison Study with Conventional Coil Technique

Purpose: To retrospectively evaluate the role of the Amplatzer Vascular Plug (AVP) in proximal splenic artery embolization (SAE) compared with coils. Materials and Methods: Forty patients had proximal SAE performed with AVP(s) or coils as the primary embolic agent for splenic artery steal syndrome (n = 23), trauma (n = 5), portal hypertension (n = 5), bleeding due to pancreatic pathology (n = 4), and pre-splenectomy (n = 3). Comparisons were made of occlusion and procedure time, cost, and radiation dose. Results: Eighteen proximal SAE procedures were successfully performed with AVP. Twenty-two procedures were performed with coils, including one failed AVP attempt, which was completed with coils. Precise deployment without migration was achieved in all 18 AVP cases. Seven of 22 (31.8%) coil procedures had distal migration without consequence. There was no statistically significant difference in mean occlusion time (24.4 min for AVP vs. 31.5 min for coils, P = 0.13), procedure time (43.7 min for AVP vs. 53.8 min for coils, P = 0.16), or cost ($1474.13 for AVP vs. $1722.51 for coils, P = 0.69). There was significant difference in radiation dose (842 mGy for AVP vs. 1,309 mGy for coils, P = 0.04). Fourteen of the 18 (78%) AVP devices required additional embolic material. Conclusions: AVP with additional embolic agents is a useful alternative for proximal SAE because of precise deployment, resistance to migration, and radiation reduction. AVP use may be limited by vessel tortuosity. The occlusion time, procedure time, and cost were reduced but this was not statistically significant due to the need for additional embolic material.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Amplatzer Vascular Plug: A Review of the Device and its Clinical Applications

The Amplatzer Vascular Plug (AVP) is an established embolic device that can be an excellent alternative to coils or detachable balloons to embolize medium to large vessels with high flow. The device is easy to use and can be precisely deployed in the target vessel with high resistance to migration and a low recanalization rate. The technical success of this device is high, indications for use are expanding, and no absolute contraindications have been reported. Since its introduction, the AVP has grown from a single device to a group of 4 models (AVP, AVP II, AVP III, and AVP 4). Each model has a unique design and features that fit different vascular anatomies, hemodynamic situations, and clinical scenarios. Therefore, the new models cannot simply be treated as replacements for older ones. Unpredictable occlusion time remains a major shortcoming for the new models of the AVP. Large vessel size, high flow status, and coagulopathy can prolong the occlusion time, which can offset the cost benefit, reduced procedure time, and reduced radiation dose typically seen with use of the AVP alone. Coils or multiple AVPs can be used to expedite the occlusion process, and large Gelfoam particles also can be used as an adjunct to achieve rapid and reliable occlusion with minimal cost.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Endovascular Broad-Neck Aneurysm Creation in a Porcine Model Using a Vascular Plug

Ruptured cerebral arterial aneurysms require prompt treatment by either surgical clipping or endovascular coiling. Training for these sophisticated endovascular procedures is essential and ideally performed in animals before their use in humans. Simulators and established animal models have shown drawbacks with respect to degree of reality, size of the animal model and aneurysm, or time and effort needed for aneurysm creation. We therefore aimed to establish a realistic and readily available aneurysm model. Five anticoagulated domestic pigs underwent endovascular intervention through right femoral access. A total of 12 broad-neck aneurysms were created in the carotid, subclavian, and renal arteries using the Amplatzer vascular plug. With dedicated vessel selection, cubic, tubular, and side-branch aneurysms could be created. Three of the 12 implanted occluders, two of them implanted over a side branch of the main vessel, did not induce complete vessel occlusion. However, all aneurysms remained free of intraluminal thrombus formation and were available for embolization training during a surveillance period of 6 h. Two aneurysms underwent successful exemplary treatment: one was stent-assisted, and one was performed with conventional endovascular coil embolization. The new porcine aneurysm model proved to be a straightforward approach that offers a wide range of training and scientific applications that might help further improve endovascular coil embolization therapy in patients with cerebral aneurysms.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Use of the Amplatzer Type 2 Plug for Flow Redirection in Failing Autogenous Hemodialysis Fistulae

PurposeTo present our experience with redirecting the outflow of mature arteriovenous fistulae (AVFs) in patients with cannulation and/or suboptimal flow problems by percutaneous intervention using the Amplatzer Vascular Plug II (AVP II).MethodsWe retrospectively reviewed patients who presented with difficulty in cannulation and/or suboptimal flow in the puncture zone of the AVF and who underwent intervention using the AVP II to redirect the outflow through a better cannulation zone from March 2009 to November 2012. The mean survival rate of all AVFs was estimated, and the effects of patient age, sex, and AVF age on the AVF survival time were determined.ResultsIn total, 31 patients (17 male and 14 female) with a mean age of 57.8 years (range, 20–79 years) were included. In 2 patients, the AVF failed within the first 15 days because of rapid thrombosis. In 9 patients, the new AVF route was working effectively until unsalvageable thrombosis developed. One of the 31 patients died 9 months before the last radiologic evaluation. The new AVF route was still being used for dialysis in the remaining 19 patients. The mean AVF survival rate was 1,061.4 ± 139.4 days (range, 788–1,334 days). Patient age, sex, and AVF age did not affect the survival time.ConclusionWe suggest that the AVP II is useful for redirecting the outflow of AVFs with cannulation problems and suboptimal flow. Patency of existing AVFs may be extended, thereby extending surgery-free or catheter intervention-free survival period.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Perigraft Plug Embolization of the Internal Iliac Artery and Implantation of a Bifurcated Stentgraft: One Treatment Option for Insufficient Tubular Stentgraft Repair of a Common Iliac Artery Aneurysm

We report an endovascular technique for the treatment of type Ia endoleak after a plain tubular stentgraft had been implanted for a large common iliac artery aneurysm with an insufficient proximal landing zone and without occlusion of the hypogastric in another hospital. CT follow-up showed an endoleak with continuous sac expansion over 12 months. This was classified as type Ia by means of dynamic contrast-enhanced MRI. Before a bifurcated stentgraft was implanted to relocate the landing zone more proximally, the still perfused ipsilateral hypogastric artery was embolized to prevent a type II endoleak. A guidewire was manipulated alongside the indwelling stentgraft. The internal iliac artery could then be selectively intubated followed by successful plug embolization of the vessel’s orifice despite the stentgraft being in place.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Amplatzer Vascular Plug Anchoring Technique to Stabilize the Delivery System for Microcoil Embolization

PurposeTo evaluate the feasibility of a novel embolization technique, the Amplatzer vascular plug (AVP) anchoring technique, to stabilize the delivery system for microcoil embolization.Materials and methodsThree patients were enrolled in this study, including two cases of internal iliac artery aneurysms and one case of internal iliac arterial occlusion prior to endovascular aortic repair. An AVP was used in each case for embolization of one target artery, and the AVP was left in place. The AVP detachment wire was then used as an anchor to stabilize the delivery system for microcoil embolization to embolize the second target artery adjacent to the first target artery. The microcatheter for the microcoils was inserted parallel to the AVP detachment wire in the guiding sheath or catheter used for the AVP.ResultsThe AVP anchoring technique was achieved and the microcatheter was easily advanced to the second target artery in all three cases.ConclusionThe AVP anchoring technique was found to be feasible to advance the microcatheter into the neighboring artery of an AVP-embolized artery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of Balloon-Occluded Retrograde Transvenous Obliteration (BRTO) Using Ethanolamine Oleate (EO), BRTO Using Sodium Tetradecyl Sulfate (STS) Foam and Vascular Plug-Assisted Retrograde Transvenous Obliteration (PARTO)

PurposeTo compare the clinical outcomes of balloon-occluded retrograde transvenous obliteration (BRTO) using ethanolamine oleate (EO), BRTO using sodium tetradecyl sulfate (STS) foam, and vascular plug-assisted retrograde transvenous obliteration (PARTO).Materials and MethodsFrom April 2004 to February 2015, ninety-five patients underwent retrograde transvenous obliteration for gastric varices were analyzed retrospectively. BRTO with EO was performed in 49 patients, BRTO with STS foam in 25, and PARTO in 21. Among them, we obtained follow-up data in 70 patients. Recurrence of gastric varices was evaluated by follow-up endoscopy or CT. Medical records were reviewed for the clinical efficacy. Statistical analyses were performed by Kaplan–Meier method, Chi-square, Fisher’s, and Kruskal–Wallis tests.ResultsTechnical and clinical success was 94.7 %. As major complications, a hemoglobinuria and a death due to disseminated intravascular coagulation (DIC) were occurred in two patients with BRTO using EO. Recurrence occurred more frequently in PARTO group (P < 0.05). Recurrence occurred in three patients in BRTO using EO group and four patients in PARTO group with 3.2 and 32.8 % of each expected 1-year recurrence rates. There was no recurrence in BRTO using STS group. Abdominal pain occurred more frequently in BRTO using EO than BRTO using STS foam and PARTO (P < 0.05). Procedure time of PARTO was shorter than two conventional BRTOs (P < 0.05).ConclusionsBRTO using STS foam or PARTO is better than BRTO using EO for treatment of gastric varices in terms of complication or procedure time. However, PARTO showed frequent recurrence of gastric varices during the long-term follow-up rather than BRTO.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Pulmonary Arteriovenous Malformations Embolized Using a Micro Vascular Plug System: Technical Note on a Preliminary Experience

AIMTo report our preliminary experience using a Micro Vascular Plug (MVP) deployed through a 2.8Fr micro-catheter for the treatment of pulmonary arteriovenous malformations (PAVMs) in a cohort of patients affected by Hereditary Haemorrhagic Telangiectasia (HHT).Materials and MethodsFour consecutive female patients (mean age 38.0 years; range 25–55 years) with PAVMs diagnosed on echocardiogram/bubble test and contrast-enhanced CT (CECT) underwent MVP embolization. One patient was symptomatic with recent transient ischaemic attack. Follow-up was undertaken at 1-month post-procedure with CECT to assess PAVMs permeability and MVP positioning and at 1-, 6-, and 12-month post-procedure, with echocardiography/bubble test and standard neurological history, to confirm absence of right-to-left shunts and recurrent symptoms.ResultsEight PAVMs were treated in 4 patients over 5 interventional sessions (mean 1.6 PAVMs per session). All PAVMs were simple, with mean feeding artery diameter of 4.25 mm. Eight 6.5 mm MVPs were deployed in total (one per lesion). Technical success was 100%. Mean procedural time and patient dose per session were 70 min (range 40–70 min) and 53418 mGy.cm{sup 2} (range 6113–101628 mGy.cm{sup 2}), respectively. No signs of reperfusion neither of MPV migration were noted at 1-month CECT follow-up. At early follow-up (mean 3.75 months; range 1–12 months), clinical success was 100% with no evidence of recurrent right-to-left shunt, and no neurological symptoms. No immediate or late complications were observed.ConclusionsMVP embolization of PAVMs appears technically feasible, safe, and effective at early follow-up. Further prospective studies are required to confirm long-term safety and efficacy of this promising technique.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Utility of Amplatzer Vascular Plug with Preoperative Common Hepatic Artery Embolization for Distal Pancreatectomy with En Bloc Celiac Axis Resection

PurposeTo evaluate the feasibility and safety of the Amplatzer vascular plug (AVP) for preoperative common hepatic embolization (CHA) before distal pancreatectomy with en bloc celiac axis resection (DP-CAR) to redistribute blood flow to the stomach and liver via the superior mesenteric artery (SMA).Materials and MethodsFour patients (3 males, 1 female; median age 69 years) with locally advanced pancreatic body cancer underwent preoperative CHA embolization with AVP. After embolization, SMA arteriography was performed to confirm the alteration of blood flow from the SMA to the proper hepatic artery.ResultsIn three of four patients, technical successes were achieved with sufficient margin from the origin of gastroduodenal artery. In one patient, the margin was less than 5 mm, although surgery was successfully performed without any problem. Eventually, all patients underwent the DP-CAR without arterial reconstruction or liver ischemia.ConclusionsAVP application is feasible and safe as an embolic procedure for preoperative CHA embolization of DP-CAR.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

MVP™ Micro Vascular Plug Systems for the Treatment of Pulmonary Arteriovenous Malformations

Purpose: To describe our institutional experience with MVP™ micro vascular plug systems for the treatment of pulmonary arteriovenous malformations (PAVMs). Materials and Methods: We performed a retrospective medical record review of 52 patients with 119 PAVMs treated exclusively with MVP™ systems (69 procedures/153 MVP™ systems) between July 2014 and July 2018. All patients had PAVMs with feeding artery diameters ≥ 2 mm. MVP™ systems were deployed according to physician preference. We collected patient demographic information; procedural data (including size of feeding artery, size and number of embolics used per PAVM, fluoroscopy time, contrast administration), technical success rates, complications, and persistence. Persistence was assessed using computed tomography angiography (CTA) performed 1–3 months and 3–5 years after embolization per clinical protocol. Results: All procedures were technically successful without major complications. Mean feeding artery diameter was 3.3 ± 1.2 mm. Mean fluoroscopy time per procedure and contrast volume administered per procedure were 35 ± 16 min and 217 ± 101 mL, respectively. A mean of 1.3 ± 0.8 MVP™ systems was used per PAVM. There were no instances of persistence during a mean follow-up time of 328 ± 258 days (range 26 to 914 days). Conclusions: For PAVMs with feeding artery diameters of 2 to 7.9 mm (mean 3.3 ± 1.2 mm), MVP™ systems are safe and effective given their high technical success rates and lack of persistence. Further prospective work will be required to elucidate the advantages and disadvantages of these MVP™ systems for PAVM embolization. Level of Evidence: Level III.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Usefulness of Amplatzer Vascular Plug for Preoperative Embolization Before Distal Pancreatectomy with En Bloc Celiac Axis Resection

Purpose: We evaluated the usefulness of the Amplatzer vascular plug (AVP) for preoperative embolization before distal pancreatectomy with en bloc celiac axis resection (DP-CAR). Materials and Methods: Between April 2010 and September 2017, 19 patients with locally advanced pancreatic body cancer underwent preoperative embolization of the common hepatic and the left gastric artery (CHA, LGA) with AVP or coils. We compared the embolization success rate, embolization-related complications, the time required for preoperative embolization before DP-CAR and the procedure costs in patients whose CHA was AVP- (n = 7) or coil (n = 12) embolized. Results: The success rate for preoperative AVP and coil embolization was 100% and 83.3%, respectively. The median procedure time was shorter in patients whose CHA was embolized with AVP than coils; the difference was not significant (p = 0.045). The total cost was significantly lower for AVP than coil embolization (p = 0.01). Conclusion: The AVP is useful for the preoperative embolization of the CHA before DP-CAR.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Simultaneous measurement of x-ray absorption spectra and kinetics : a fixed-bed, plug-flow operando reactor.

An inexpensive fixed-bed, plug-flow operando reactor is described in which X-ray absorbance and kinetic data can be measured simultaneously. Pt L3 (11.56 keV) XANES and EXAFS data were obtained on a 1.5% Pt/silica catalyst in borosilicate glass reactors of different diameters, 3-6 mm, and thicknesses, 0.3-1.2 mm, some of which are capable of operation at pressures up to about 40 atm. Additionally, polyimide tubular reactors with low absorbance can be used for lower energy edges of the 3d transition metals, or fluorescence detection for low concentration or highly absorbing supports. With the polyimide reactor, however, the pressure is limited to {approx}3.5 atm and the reaction temperature to about 300 C. To validate the reactor, the rate and activation energies for the water-gas shift reaction on 2% Pd, 13.7% Zn on Al2O3 catalyst were within 15% of those obtained in a standard laboratory reactor, which is within laboratory reproducibility. In addition, the Pd K edge (24.35 keV) XANES and EXAFS data on pre-reduced catalyst were identical to that previously determined on a regular cell. The EXAFS data show that the degree of Pd-Zn alloy formation changes with reaction temperature demonstrating the importance of characterizing the catalyst under reaction conditions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Polarization-based plug-and-play measurement-device-independent quantum key distribution

Measurement-device-independent quantum key distribution (MDI-QKD) has received much attention, with the goal of overcoming all of the security loopholes caused by an imperfect detection system. We here propose a plug-and-play MDI-QKD (P&P MDI-QKD) scheme whereby an untrusted relay node, Charlie, owns a laser and sends photons to Alice and Bob. Alice (Bob) modulates the polarization of the incident photons and returns them to Charlie. Charlie uses a modified Bell state analyzer (BSA) to perform Bell state measurements (BSM). In comparison with the original version of MDI-QKD, our scheme exploits a single untrusted laser as the photon source. This makes the signal photons identical and enhances the Hong-Ou-Mandel effect. Second, because of the P&P structure, the setup can automatically eliminate the birefringence influence of the fibers, which makes the setup highly stable. Finally, our modified BSA can identify |Φ〉{sup +} and |Φ〉{sup −} of four Bell states with polarization encoding but not |Ψ〉{sup +} and |Ψ〉{sup −}. Based on practical experimental parameters, a simulation showed that the maximum theoretical secure transmission distance could reach more 280 km.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Comprehensive powertrain modeling for heavy-duty applications: A study of plug-in hybrid electric bus

A comprehensive forward-looking powertrain model with an efficiency-based control strategy was developed to achieve real-time optimization of plug-in hybrid electric buses while considering the real vehicle drivability and the practical operation of all powertrain components under real driving conditions. The control strategy is based on a supervisory control algorithm that alternately employs charge-dominant control and discharge-dominant control to manage multiple powertrain sources, and enable an optimal overall efficiency-based powertrain operation state by maximizing the inherent optimal powertrain efficiency through best all transmission gear choice and the blend of motor and/or engine power. In the model, a component energy efficiency database was developed to rapidly enable an smart and optimal operating state determined from a set of efficiency maps characterizing the component and powertrain control states as a function of the instantaneous vehicle operational condition. The results revealed that the energy savings achieved with the innovative powertrain control improved by 10%–30% compared with the baseline hybrid powertrain control strategy. The benefits of eco-driving with respect to energy consumption were also evaluated using the powertrain model. The powertrain control model was implemented into a real hybrid bus. Measured energy savings with the optimized control strategy were similar to the simulated results.

33 ADVANCED PROPULSION SYSTEMS↗

Impact of plug-in hybrid electric vehicles on power systems with demand response and wind power.

This paper uses a new unit commitment model which can simulate the interactions among plug-in hybrid electric vehicles (PHEVs), wind power, and demand response (DR). Four PHEV charging scenarios are simulated for the Illinois power system: (1) unconstrained charging, (2) 3-hour delayed constrained charging, (3) smart charging, and (4) smart charging with DR. The PHEV charging is assumed to be optimally controlled by the system operator in the latter two scenarios, along with load shifting and shaving enabled by DR programs. The simulation results show that optimally dispatching the PHEV charging load can significantly reduce the total operating cost of the system. With DR programs in place, the operating cost can be further reduced.

17 WIND ENERGY↗

Cost Analysis of Plug-In Hybred Electric Vehicles Using GPS-Based Longitudinal Travel Data

Using spatial, longitudinal travel data of 415 vehicles over 3 18 months in the Seattle metropolitan area, this paper estimates the operating costs of plug-in hybrid electric vehicles (PHEVs) of various electric ranges (10, 20, 30, and 40 miles) for 3, 5, and 10 years of payback period, considering different charging infrastructure deployment levels and gasoline prices. Some key findings were made. (1) PHEVs could help save around 60% or 40% in energy costs, compared with conventional gasoline vehicles (CGVs) or hybrid electric vehicles (HEVs), respectively. However, for motorists whose daily vehicle miles traveled (DVMT) is significant, HEVs may be even a better choice than PHEV40s, particularly in areas that lack a public charging infrastructure. (2) The incremental battery cost of large-battery PHEVs is difficult to justify based on the incremental savings of PHEVs operating costs unless a subsidy is offered for largebattery PHEVs. (3) When the price of gasoline increases from $4/gallon to $5/gallon, the number of drivers who benefit from a larger battery increases significantly. (4) Although quick chargers can reduce charging time, they contribute little to energy cost savings for PHEVs, as opposed to Level-II chargers.

Wu, Xing↗

Data mining of plug-in electric vehicles charging behavior using supply-side data

This paper aims to better understand the charging patterns of plug-in electric vehicles (PEVs) and identify factors that may significantly impact PEVs’ charging behavior. We collected 189,864 supply-side charging session data over 13 months from 821 charging stations in Illinois from ChargePoint. Through descriptive and regression analyses, we characterize the distributions of key charging behavior indicators, including charging location, dwell time, and battery start state of charge (SOC), and quantify the impacts of closely related factors on these charging behaviors. In this work, we find that: (1) PEVs are more likely to charge in the morning at multifamily commercial locations with a lower start SOC compared with single family residential locations; (2) Weekday and morning sessions are more likely to utilize workplace charging and have shorter dwell time compared with weekend and afternoon sessions; (3) Single family residential area and locations with Levels 1/2 chargers have a higher start SOC and longer dwell time compared with other locations and DC fast chargers (DCFCs). These findings provide policy insights to identify potential time and locations to incentivize PEVs for grid services, as well as identify critical location categories for further charging infrastructure investment to better reduce range anxiety and promote PEV adoption.

33 ADVANCED PROPULSION SYSTEMS↗