Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PLASMA DIAGNOSTICS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Compact collimated fiber optic array diagnostic for railgun plasmas

We developed and tested a compact collimated 16 channel fiber optic array diagnostic for studying the light emission of railgun armature plasmas with approximately millimeter spatial and submicrosecond temporal resolution. The design and operational details of the diagnostic are described. Plasma velocities, oscillation, and dimension data from the diagnostic for the Livermore fixed hybrid armature experiment are presented and compared with one-dimensional simulations. The techniques and principles discussed allow the extension of the diagnostic to other railgun and related dense plasma experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Distinct optical properties of relativistically degenerate matter

In this paper, we use the collisional quantum magnetohydrodynamic (CQMHD) model to derive the transverse dielectric function of a relativistically degenerate electron fluid and investigate various optical parameters, such as the complex refractive index, the reflection and absorption coefficients, the skin-depth and optical conductivity. In this model we take into accounts effects of many parameters such as the atomic-number of the constituent ions, the electron exchange, electron diffraction effect and the electron-ion collisions. Study of the optical parameters in the solid-density, the warm-dense-matter, the big-planetary core, and the compact star number-density regimes reveals that there are distinct differences between optical characteristics of the latter and the former cases due to the fundamental effects of the relativistic degeneracy and other quantum mechanisms. It is found that in the relativistic degeneracy plasma regime, such as found in white-dwarfs and neutron star crusts, matter possess a much sharper and well-defined step-like reflection edge beyond the x-ray electromagnetic spectrum, including some part of gamma-ray frequencies. It is also remarked that the magnetic field intensity only significantly affects the plasma reflectivity in the lower number-density regime, rather than the high density limit. Current investigation confirms the profound effect of relativistic degeneracy on optical characteristics of matter and can provide an important plasma diagnostic tool for studying the physical processes within the wide scope of quantum plasma regimes be it the solid-density, inertial-confined, or astrophysical compact stars.

79 ASTRONOMY AND ASTROPHYSICS↗

The plasma wake of the Shuttle Orbiter

One of the objectives of the Plasma Diagnostics Package (PDP) instrumentation on Spacelab 2 was to obtain information about the plasma wake of the Shuttle Orbiter. Plasma density and electron temperature data are presented, which were obtained while the PDP was attached to the Shuttle remote manipulator system, and while the PDP was a free-flying satellite. Wake crossings by the PDP from about 40 m to about 240 m behind the Orbiter provide information about the structure of the mid and far wake of the Orbiter. As expected, the wake is characterized by density depressions, relative to the ambient ionospheric plasma, and by enhancements of the electron temperature, particularly in the near and mid wake. The observed electron temperature enhancements appear to be in line with previous spacecraft observations.

Murphy, G. B.↗

Characterization of an 8-cm Diameter Ion Source System

Results of tests characterizing an 8-cm diameter ion source are presented. The tests were conducted in three separate vacuum test facilities at the University of Alabama-Huntsville, Colorado State University, and L3 Communications' ETI division. Standard ion optics tests describing electron backstreaming and total-voltage-limited impingement current behavior as a function of beam current were used as guidelines for selecting operating conditions where more detailed ion beam measurements were performed. The ion beam was profiled using an in-vacuum actuating probe system to determine the total ion current density and the ion charge state distribution variation across the face of the ion source. Both current density and ExB probes were utilized. The ion current density data were used to obtain integrated beam current, beam flatness parameters, and general beam profile shapes. The ExB probe data were used to determine the ratio of doubly to singly charged ion current. The ion beam profile tests were performed at over six different operating points that spanned the expected operating range of the DAWN thrusters being developed at L3. The characterization tests described herein reveal that the 8-cm ion source is suitable for use in (a) validating plasma diagnostic equipment, (b) xenon ion sputtering and etching studies of spacecraft materials, (c) plasma physics research, and (d) the study of ion thruster optics at varying conditions.

Li, Zhongmin↗

Magnetospheric multiprobes: MMP/CHEMSAT

The magnetospheric multiprobes (MMP) are a set of ejectable, self contained, limited lifetime free flyers which are designed to make plasma diagnostic measurements at multiple locations within telemetry range of the space station's coorbiting platform and polar platform. When configured as CHEMSATs, one or more MMP's will conduct chemical releases as tracers or modifiers of the local plasma and field environment, while diagnostic measurements are made from other MMP's and from the nearby platform. The probes will be battery powered and will have lifetimes of a few days to several weeks. Up to 12 probes would be placed on the coorbiting platform and the polar platform every six months and two years respectively for use in the campaign mode of operation.

Burch, J.↗

Magnetospheric multiprobes (MMP/CHEMSAT)

The magnetospheric multiprobes (MMP) are a set of ejectable, self contained, limited lifetime free flyers which are designed to make plasma diagnostic measurements at multiple locations within telemetry range of the space station's coorbiting platform and polar platform. When configured as CHEMSATs, one or more MMP's will conduct chemical releases as tracers or modifiers of the local plasma and field environment, while diagnostic measurements are made from other MMP's and from the nearby platform. The probes will be battery powered and will have lifetimes of a few days to several weeks. Up to 12 probes would be placed on the coorbiting platform and the polar platform every six months and two years respectively for use in the campaign mode of operation.

Burch, J.↗

Reconstruction and analysis of exploding wire particle trajectories via automatic calibration of stereo images

Quantitative understanding of the physics of dust or granular matter transport significantly impacts several aspects of burning plasma science and technology. Here, this work takes machine vision techniques popular in robotics and self-driving cars and applies them to identification and analysis of microparticles generated from exploding wires. Using only the image frames and knowledge of the intrinsic properties of the cameras, a Python code was written to identify the particles, automatically calibrate the relative image positions, and extract trajectory data. After identifying approximately 50 particles based on the timing of secondary particle explosions, the eight point and random sample consensus algorithms were used to determine the geometric correlation between the cameras. Over 100 particle matches were found between the two camera views. These correlated trajectories were used in subsequent 3D track reconstruction and analysis of the physics behind the particle motion. The 3D reconstruction resulted in accurate positioning of the particles with respect to the experimental setup. The particle motion was consistent with the effects of a 1 g gravitational field modified by drag forces. Lastly, the methods and analyses presented here can be used in many facets of high temperature plasma diagnostics.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A two photon absorption laser induced fluorescence diagnostic for fusion plasmas

The quality of plasma produced in a magnetic confinement fusion device is influenced to a large extent by the neutral gas surrounding the plasma. The plasma is fueled by the ionization of neutrals, and charge exchange interactions between edge neutrals and plasma ions are a sink of energy and momentum. Here we describe a diagnostic capable of measuring the spatial distribution of neutral gas in a magnetically confined fusion plasma. A high intensity (5 MW/cm{sup 2}), narrow bandwidth (0.1 cm{sup -1}) laser is injected into a hydrogen plasma to excite the Lyman {beta} transition via the simultaneous absorption of two 205 nm photons. The absorption rate, determined by measurement of subsequent Balmer {alpha} emission, is proportional to the number of particles with a given velocity. Calibration is performed in situ by filling the chamber to a known pressure of neutral krypton and exciting a transition close in wavelength to that used in hydrogen. We present details of the calibration procedure, including a technique for identifying saturation broadening, measurements of the neutral density profile in a hydrogen helicon plasma, and discuss the application of the diagnostic to plasmas in the DIII-D tokamak.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Perturbations induced by electrostatic probe in the discharge of Hall thrusters

Emissive and Langmuir probes are two widely used plasma diagnostic techniques that, when used properly, give access to a wide range of information on the plasma’s ions and electrons. We show here that their use in small and medium power Hall thrusters produces large perturbations in the discharge characteristics. Potential measurements performed by both probes and non-invasive Laser Induced Fluorescence (LIF) spectroscopy highlight significant discrepancies in the discharge profile. This phenomenon is observed both in the 200 W and the 1.5 kW-class thrusters. In order to have a better understanding of these perturbations, ion velocity distribution functions are acquired by LIF spectroscopy at different positions in the smaller thruster, with and without the probes. Emissive probes are shown to produce the biggest perturbation, shifting the acceleration region upstream. The probe insertion is also shown to have significant effect on both the average discharge current, increasing it by as much as 30%, and its harmonic content in both amplitude and spectrum. These perturbations appear as the probe tip passes a threshold located between 0 and 5 mm downstream of the thruster exit plane.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The application of atomic physics within impurity diagnostics for fusion plasmas

With the focus of ITER on the transport and emission properties of tungsten, generating atomic data for complex species has received much interest. Focusing on impurity influx diagnostics, we discuss recent work on heavy species. Perturbative approaches do not work well for near neutral systems so non-perturbative data are required, presenting a particular challenge for these influx diagnostics. Recent results on Mo{sup +} are given as an illustration of how the diagnostic applications can guide the theoretical calculations for such systems.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Second generation fusion neutron time-of-flight spectrometer at optimized rate for fully digital data acquisition

The progress on high-rate event recording of data is taken as starting point to revisit the design of fusion neutron spectrometers based on the TOF (time-of-flight) technique. The study performed was aimed at how such instruments for optimized rate (TOFOR) can be further developed to enhance the plasma diagnostic capabilities based on measurement of the 2.5 MeV dd neutron emission from D plasmas, especially the weak spectral components that depend on discrimination of extraneous events. This paper describes a design (TOFOR II) adapted for use with digital wave form recording of all detector pulses providing information on both amplitude (pulse height) and timing. The results of simulations are presented and the performance enhancement is assessed in comparison to the present.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spectroscopic, imaging, and probe diagnostics of laser plasma plumes expanding between confining surfaces

Laser plasma plumes were generated in aluminum rectangular cavities of fixed depth (6 mm) and varying height (2.0, 1.5, and 1.0 mm). Space and time resolved visible emission spectroscopy, gated intensified visible imaging, and Langmuir probe diagnostics were utilized to diagnose the evolution of the confined plasma plumes in comparison to freely expanding plasma plume generated from ablation of a planar target. The constrained plasma behavior displayed a multiphase history. Early stage interactions (t<100 ns) resulted in enhanced continuum and line emission, shockwave formation and plasma plume rebound. Later phase, long duration plasma-surface interactions (t>160 ns) resulted in sustained 'decay', i.e., a rapid termination of continuum emission, in concert with decreases in peak electron density (N{sub e}) and plasma temperature (T). This later phase originates from loss mechanisms which bleed the plasma plume of thermal energy and charged particles. These loss mechanisms increase in magnitude as the duration of the plasma-surface interaction increases. The transition from enhancement phase, originating from hydrodynamic containment, and plasma-surface collisions, to decay phase is described and occurs for each cavity at a different point in the space time history.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

On the expansion of non-ideal copper plasma into vacuum

The expansion of non-ideal copper plasma into vacuum is analyzed for the conditions typical for explosive electron emission in vacuum arcs. The computational model solves the Euler equations with an equation of state (EoS) for weakly non-ideal plasma, taking into account the ionization energy correction due to electron–ion Coulomb coupling. We have ascertained that the EoS has insignificant influence on the plasma expansion while the plasma properties and composition change drastically. Based on our simulation results, we discuss the validity of the “frozen” state theory often used in the vacuum arc plasma diagnostics.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Nonrelativistic structure calculations of two-electron ions in a strongly coupled plasma environment

In this work, the controversy between the interpretations of recent measurements on dense aluminum plasma created with the Linac coherent light source (LCLS) x-ray free electron laser (FEL) and the Orion laser has been addressed. In both kinds of experiments, heliumlike and hydrogenlike spectral lines are used for plasma diagnostics. However, there exist no precise theoretical calculations for He-like ions within a dense plasma environment. The strong need for an accurate theoretical estimate for spectral properties of He-like ions in a strongly coupled plasma environment leads us to perform ab initio calculations in the framework of the Rayleigh-Ritz variation principle in Hylleraas coordinates where an ion-sphere potential is used. An approach to resolve the long-drawn problem of numerical instability for evaluating two-electron integrals with an extended basis inside a finite domain is presented here. The present values of electron densities corresponding to the disappearance of different spectral lines obtained within the framework of an ion-sphere potential show excellent agreement with Orion laser experiments in Al plasma and with recent theories. Moreover, this method is extended to predict the critical plasma densities at which the spectral lines of H-like and He-like carbon and argon ions disappear. Incidental degeneracy and level-crossing phenomena are being reported for two-electron ions embedded in strongly coupled plasma. Thermodynamic pressure experienced by the ions in their respective ground states inside the ion spheres is also reported.

Bhattacharyya, S.↗

Measurements of plasma parameters in the vicinity of the Space Shuttle

A Langmuir probe flown as part of the Plasma Diagnostics Package aboard the third Space Shuttle flight was used to determine electron densities, temperatures, and plasma potential in the vicinity of the Shuttle Orbiter. Measurements taken both in the cargo bay and 10 m above the cargo bay on the Remote Manipulator System arm are consistent with small satellite and laboratory results, in that reduced densities and elevated temperatures are observed in the Shuttle wake. The primary difference in the Shuttle measurements is one of magnitude; i.e., orders-of-magnitude density decreases and factor-of-five temperature enhancements. Analysis of data taken in (Delta N)/N turbulence can be as high as a few percent, and the most intense turbulence seems to occur near regions with a steep gradient in plasma pressure.

Murphy, G.↗

Ultrashort pulse laser-triggering of long gap high voltage switches

Laser-triggered high voltage switches need longer length and lifetime laser plasmas at controlled plasma densities in order to achieve optimal operational parameters (such as short runtime, low temporal jitter, and high voltage hold-off). We have approached the problem by considering ultrashort laser pulses of sub-picosecond duration for the high voltage trigger source. To this end, several laser plasma diagnostic techniques were employed to quantify the ionization and to determine methods for appropriately tailoring the laser plasma for switch ing purposes. Switching behavior under basic plasma conditions and with improved plasma channels are discussed.

Rambo, Patrick K.↗

Instrument for differential on flux vector measurements on Spacelab 2

The DIF (differential ion flux) probe used on the Spacelab-2 mission as part of the PDP (plasma diagnostic package) as well as the DIF design, operational characteristics and data reduction procedures required to obtain plasma properties are described. The basic principles, the sensor head design, and the electronics design are discussed. Plasma properties such as ion drift energy and temperature, ion flow direction, and ion flux density are explained, and in addition, calibration procedures and calibration data on detection of multiple ion streams and detection of ion streams superimposed on an isotropic plasma are analyzed. Finally, the mounting and role of the DIF probe on the PDP are briefly reviewed. Schematics of the instrument and of its control logic are included.

Stone, N. H.↗