Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “OMEGA”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Gamma bang time analysis at OMEGA

Absolute bang time measurements with the gas Cherenkov detector (GCD) and gamma reaction history (GRH) diagnostic have been performed to high precision at the OMEGA laser facility at the University of Rochester with bang time values for the two diagnostics agreeing to within 5 ps on average. X-ray timing measurements of laser-target coupling were used to calibrate a facility-generated laser timing fiducial with rms spreads in the measured coupling times of 9 ps for both GCD and GRH. Increased fusion yields at the National Ignition Facility (NIF) will allow for improved measurement precision with the GRH easily exceeding NIF system design requirements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

4{omega} Thomson scattering probe for high-density plasma characterization at Titan

In preparation for the upcoming experiments on the Titan laser at the Jupiter Laser Facility, a new Thomson scattering system has been designed and implemented. This system allows electron temperature and density measurements in a high-density regime (n{sub e}>10{sup 21} cm{sup -3}). A 263 nm probe has been demonstrated to produce a total energy of 15 J at 4{omega}(263 nm) in a 1 ns square pulse with a focal spot size of 100 {mu}m. This probe has been used for imaging Thomson scattering of the ion feature. The goal of this study is to investigate the heating of a preformed plasma by a short-pulse heater beam.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Crossed-beam energy transfer in implosion experiments on OMEGA

Radiative hydrodynamic simulations of implosion experiments on the OMEGA laser system [Boehly et al., Opt. Commun. 133, 495 (1997)] show that energy transfer between crossing laser beams can reduce laser absorption by 10%-20%. A new quantitative model for the crossed-beam energy transfer has been developed, allowing one to simulate the coupling of multiple beams in the expanding corona of implosion targets. Scattered-light and bang-time measurements show good agreement with predictions of this model when nonlocal heat transport is employed. The laser absorption can be increased by narrowing laser beams and/or employing two-color light, which both reduce the crossed-beam energy transfer.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Initial cone-in-shell fast-ignition experiments on OMEGA

Fast ignition is a two-step inertial confinement fusion concept where megaelectron volt electrons ignite the compressed core of an imploded fuel capsule driven by a relatively low-implosion velocity. Initial surrogate cone-in-shell, fast-ignitor experiments using a highly shaped driver pulse to assemble a dense core in front of the cone tip were performed on the OMEGA/OMEGA EP Laser [T. R. Boehly et al., Opt. Commun. 133, 495 (1997); L. J. Waxer et al., Opt. Photonics News 16, 30 (2005)]. With optimal timing, the OMEGA EP pulse produced up to {approx}1.4 x 10{sup 7} additional neutrons which is a factor of {approx}4 more neutrons than without short-pulse heating. Shock-breakout measurements performed with the same targets and drive conditions demonstrate an intact cone tip at the time when the additional neutrons are produced. Velocity interferometer system for any reflector measurements show that x-rays from the shell's coronal plasma preheat the inner cone wall of thin-walled Au cones, while the thick-walled cones that are used in the integrated experiments are not affected by preheat.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Characteristics of OTFTs based on {alpha}-{omega}- Dihexyl-sexithiophene(DH6T) using Organic Molecular Beam Deposition

We fabricated an organic thin film transistor using organic semiconductor material {alpha}-{omega}- Dihexyl-sexithiophene (DH6T). The organic semiconductor was deposited using organic molecular beam deposition (OMBD). The deposition rate was 0.3A/s and the final thickness was 100 nm. After deposition, we annealed at 40 deg. C, 60 deg. C, 80 deg. C. In present, DH6T was used as a p-type semiconductor, so we measured 0V{approx}-40V. We measured drain current versus drain voltage, drain current versus gate voltage, calculated mobility and On/Off ratio at 40 deg. C, 60 deg. C, 80 deg. C. The field-effect mobility was 8x10-{sup 3}, 9x10-{sup 3}, 1.2x10-{sup 2}, and on/off ratio was 1.75x10-{sup 2}, 1.85x10-{sup 2}, 2.17x10-{sup 2}, respectively.

36 MATERIALS SCIENCE↗

Polarization observables from the photoproduction of omega-mesons using linearly polarized photons

We report on the photon beam asymmetry, {Sigma}, of the {omega} meson decaying into {pi}{sup +}, {pi}{sup -}, {pi}{sup 0} using a beam of linearly polarized photons in the photon energy region of E{sub {gamma}} = 1.9 GeV. These preliminary results are from the summer 2005 g8b dataset, which were collected with the CLAS detector in Hall B of Jefferson Lab.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A spherical crystal imager for OMEGA EP

A narrowband x ray imager for the Cu Kα line at ~8 keV using a spherically bent quartz crystal has been implemented on the OMEGA EP laser at the University of Rochester. The quartz crystal is cut along the 2131 (211) planes for a 2d spacing of 0.3082 nm, resulting in a Bragg angle of 88.7°, very close to normal incidence. An optical system is used to remotely align the spherical crystal without breaking the vacuum of the target chamber. The images show a high signal-to-background ratio of typically >100:1 with laser energies ≥1 kJ at a 10-ps pulse duration and a spatial resolution of less than 10 μm.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Source characterization and modeling development for monoenergetic-proton radiography experiments on OMEGA

A monoenergetic proton source has been characterized and a modeling tool developed for proton radiography experiments at the OMEGA [T. R. Boehly et al., Opt. Comm. 133, 495 (1997)] laser facility. Multiple diagnostics were fielded to measure global isotropy levels in proton fluence and images of the proton source itself provided information on local uniformity relevant to proton radiography experiments. Global fluence uniformity was assessed by multiple yield diagnostics and deviations were calculated to be {approx}16% and {approx}26% of the mean for DD and D{sup 3}He fusion protons, respectively. From individual fluence images, it was found that the angular frequencies of Greater-Than-Or-Equivalent-To 50 rad{sup -1} contributed less than a few percent to local nonuniformity levels. A model was constructed using the Geant4 [S. Agostinelli et al., Nuc. Inst. Meth. A 506, 250 (2003)] framework to simulate proton radiography experiments. The simulation implements realistic source parameters and various target geometries. The model was benchmarked with the radiographs of cold-matter targets to within experimental accuracy. To validate the use of this code, the cold-matter approximation for the scattering of fusion protons in plasma is discussed using a typical laser-foil experiment as an example case. It is shown that an analytic cold-matter approximation is accurate to within Less-Than-Or-Equivalent-To 10% of the analytic plasma model in the example scenario.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Testing a new NIF neutron time-of-flight detector with a bibenzyl scintillator on OMEGA

A new neutron time-of-flight (nTOF) detector with a bibenzyl crystal as a scintillator has been designed and manufactured for the National Ignition Facility (NIF). This detector will replace a nTOF20-Spec detector with an oxygenated xylene scintillator currently operational on the NIF to improve the areal-density measurements. In addition to areal density, the bibenzyl detector will measure the D-D and D-T neutron yield and the ion temperature of indirect- and direct-drive-implosion experiments. The design of the bibenzyl detector and results of tests on the OMEGA Laser System are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

X-ray streak camera cathode development and timing accuracy of the 4{omega} ultraviolet fiducial system at the National Ignition Facility

The convergent ablator experiments at the National Ignition Facility (NIF) are designed to measure the peak velocity and remaining ablator mass of an indirectly driven imploding capsule. Such a measurement can be performed using an x-ray source to backlight the capsule and an x-ray streak camera to record the capsule as it implodes. The ultimate goal of this experiment is to achieve an accuracy of 2% in the velocity measurement, which translates to a {+-}2 ps temporal accuracy over any 300 ps interval for the streak camera. In order to achieve this, a 4{omega} (263 nm) temporal fiducial system has been implemented for the x-ray streak camera at NIF. Aluminum, titanium, gold, and silver photocathode materials have been tested. Aluminum showed the highest relative quantum efficiency, with five times more peak signal counts per fiducial pulse when compared to Gold. The fiducial pulse data were analyzed to determine the centroiding statistical accuracy for incident laser pulse energies of 1 and 10 nJ, showing an accuracy of {+-}1.6 ps and {+-}0.7 ps, respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A reflective optical transport system for ultraviolet Thomson scattering from electron plasma waves on OMEGA

A reflective optical transport system has been designed for the OMEGA Thomson-scattering diagnostic. A Schwarzschild objective that uses two concentric spherical mirrors coupled to a Pfund objective provides diffraction-limited imaging across all reflected wavelengths. This enables the operator to perform Thomson-scattering measurements of ultraviolet (0.263 {mu}m) light scattered from electron plasma waves.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The x-ray source application test cassette for radiation exposures at the OMEGA laser

We have designed a sample cassette that can be used to position up to six samples in the OMEGA laser chamber. The cassette accommodates round samples up to 38.1 mm (1.5{sup Double-Prime }) in diameter and square samples up to 27 mm on a side, any of which can be up to 12.7 mm thick. Smaller specimens are centered with spacers. The test cassette allows each sample to have a unique filter scheme, with multiple filter regions in front of each sample. This paper will present mechanical design considerations and operational aspects of the x-ray source application cassette.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-resolution spectroscopy used to measure inertial confinement fusion neutron spectra on Omega (invited)

The areal density ({rho}R) of cryogenic DT implosions on Omega is inferred by measuring the spectrum of neutrons that elastically scatter off the dense deuterium (D) and tritium (T) fuel. Neutron time-of-flight (nTOF) techniques are used to measure the energy spectrum with high resolution. High signal-to-background data has been recorded on cryogenic DT implosions using a well-collimated 13.4-m line of sight and an nTOF detector with an advanced liquid scintillator compound. An innovative method to analyze the elastically scattered neutron spectra was developed using well-known cross sections of the DT nuclear reactions. The estimated areal densities are consistent with alternative {rho}R measurements and 1-D simulations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Monte Carlo validation experiments for the gas Cherenkov detectors at the National Ignition Facility and Omega

The gas Cherenkov detectors at NIF and Omega measure several ICF burn characteristics by detecting multi-MeV nuclear γ emissions from the implosion. Of primary interest are γ bang-time (GBT) and burn width defined as the time between initial laser-plasma interaction and peak in the fusion reaction history and the FWHM of the reaction history respectively. To accurately calculate such parameters the collaboration relies on Monte Carlo codes, such as GEANT4 and ACCEPT, for diagnostic properties that cannot be measured directly. This paper describes a series of experiments performed at the High Intensity γ Source (HIγS) facility at Duke University to validate the geometries and material data used in the Monte Carlo simulations. Results published here show that model-driven parameters such as intensity and temporal response can be used with less than 50% uncertainty for all diagnostics and facilities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Observation of early shell-dopant mix in OMEGA direct-drive implosions and comparisons with radiation-hydrodynamic simulations

Temporally, spatially, and spectrally resolved x-ray image data from direct-drive implosions on OMEGA were interpreted with the aid of radiation-hydrodynamic simulations. Neither clean calculations nor those using a turbulent mix model can explain fully the observed migration of shell-dopant material (titanium) into the core. Shell-dopant migration was observed via time-dependent, spatially integrated spectra, and spatially and spectrally resolved x-ray images of capsule implosions and resultant dopant emissions. The titanium emission was centrally peaked in narrowband x-ray images. In post-processed clean simulations, the peak titanium emission forms in a ring in self-emission images as the capsule implodes. Post-processed simulations with mix reproduce trends in time-dependent, spatially integrated spectra, as well having centrally peaked Ti emission in synthetic multiple monochromatic imager. However, mix simulations still do not transport Ti to the core as is observed in the experiment. This suggests that phenomena in addition to the turbulent mix must be responsible for the transport of Ti. Simple diffusion estimates are unable to explain the early Ti mix into the core. Mechanisms suggested for further study are capsule surface roughness, illumination non-uniformity, and shock entrainment.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The NIF x-ray spectrometer calibration campaign at Omega

The calibration campaign of the National Ignition Facility X-ray Spectrometer (NXS) was carried out at the OMEGA laser facility. Spherically symmetric, laser-driven, millimeter-scale x-ray sources of K-shell and L-shell emission from various mid-Z elements were designed for the 2–18 keV energy range of the NXS. The absolute spectral brightness was measured by two calibrated spectrometers. We compare the measured performance of the target design to radiation hydrodynamics simulations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-dynamic-range neutron time-of-flight detector used to infer the D(t,n){sup 4}He and D(d,n){sup 3}He reaction yield and ion temperature on OMEGA

Upgraded microchannel-plate–based photomultiplier tubes (MCP-PMT’s) with increased stability to signal-shape linearity have been implemented on the 13.4-m neutron time-of-flight (nTOF) detector at the Omega Laser Facility. This diagnostic uses oxygenated xylene doped with diphenyloxazole C{sub 15}H{sub 11}NO + p-bis-(o-methylstyryl)-benzene (PPO + bis-MSB) wavelength shifting dyes and is coupled through four viewing ports to fast-gating MCP-PMT’s, each with a different gain to allow one to measure the light output over a dynamic range of 1 × 10{sup 6}. With these enhancements, the 13.4-m nTOF can measure the D(t,n){sup 4}He and D(d,n){sup 3}He reaction yields and average ion temperatures in a single line of sight. Once calibrated for absolute neutron sensitivity, the nTOF detectors can be used to measure the neutron yield from 1 × 10{sup 9} to 1 × 10{sup 14} and the ion temperature with an accuracy approaching 5% for both the D(t,n){sup 4}He and D(d,n){sup 3}He reactions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Particle X-ray Temporal Diagnostic (PXTD) for studies of kinetic, multi-ion effects, and ion-electron equilibration rates in Inertial Confinement Fusion plasmas at OMEGA (invited)

Here, a Particle X-ray Temporal Diagnostic (PXTD) has been implemented on OMEGA for simultaneous time-resolved measurements of several nuclear products as well as the x-ray continuum produced in High Energy Density Plasmas and Inertial Confinement Fusion implosions. The PXTD removes systematic timing uncertainties typically introduced by using multiple instruments, and it has been used to measure DD, DT, D 3 He, and T 3 He reaction histories and the emission history of the x-ray core continuum with relative timing uncertainties within ±10-20 ps. This enables, for the first time, accurate and simultaneous measurements of the x-ray emission histories, nuclear reaction histories, their time differences, and measurements of T i (t) and T e (t) from which an assessment of multiple-ion-fluid effects, kinetic effects during the shock-burn phase, and ion-electron equilibration rates can be made.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗