Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Nuclear Data Sensitivities”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Dynamical System Scaling Application to Zircaloy Cladding Thermal Response During Reactivity-Initiated Accident Experiment

New fuel design and development currently requires 20 to 25 years to be qualified for use by the nuclear power industry. The thermal-hydraulics community has taken advantage of scaling theory to design reduced scale experiments that correctly preserve dominant key phenomena while quantifying distorted phenomena. These techniques can be leveraged in the design and analysis of fuel performance experiments to help reduce the timeline associated with fuel design and development. This study uses the Dynamical System Scaling (DSS) method to analyze cladding temperature data from the recent SETH-C experiment in the TREAT facility and accompanying BISON simulations to assess dynamic distortions occurring throughout the fast power excursion transient. The DSS analysis revealed that on the cool down from peak cladding temperature that the fuel radial power profile is the most sensitive modeling parameter with a heterogenous radial peaking factor corresponding to the lowest distortion compared to a uniform energy deposition. For the heat up to peak cladding temperature the heterogeneous radial power profile corresponded to the shortest process action. Finally, for the heat up to peak cladding temperature, the gap conductance model sensitivity was quantified using process action and shows that the default Light Water Reactor gap conductance model corresponded to the longest process action.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

SOURCES4D

SOURCES is a code for computing neutron source rates and spectra from spontaneous fission (including delayed neutrons) and (alpha,n) reactions in homogeneous materials and (alpha,n) reactions in single-interface and two-interface geometries. SOURCES is a Los Alamos National Laboratory (LANL) code that is written in FORTRAN and distributed through the Radiation Safety Information Computation Center (RSICC). LANL’s last release of SOURCES to RSICC was SOURCES4C in 2002. This disclosure covers the latest version of SOURCES, SOURCES4D. This version adds sensitivity capabilities for (alpha,n) sources in homogeneous materials. Specifically, SOURCES4D writes new output that can be used to calculate, in post-processing, first and second derivatives of the (alpha,n) source rate density and spectrum with respect to nuclide densities in a homogeneous material and first derivatives of the (alpha,n) source rate density and spectrum with respect to nuclide stopping powers and (alpha,n) cross sections (nuclear data). These derivatives are useful for uncertainty quantification, predictive modeling, and other applications in neutron transport problems.

Favorite, Jeffrey A.↗

Coalescence of DNA Double Strand Breaks Induced by Galactic Cosmic Radiation is Modulated by Genetics in 15 Inbred Strains of Mice

In this manuscript we address the challenges associated with the ability to predict radiation sensitivity associated with exposure to either cosmic radiation or X-rays in a population study, by monitoring DNA damage sensing protein 53BP1 forming small nuclear radiation-induced foci (RIF) as a surrogate biomarker of DNA double strand breaks (DSB). 76 primary skin fibroblasts were isolated from 10 collaborative cross strains and five reference inbred mice (C57Bl/6, BALB/CByJ, B6C3, C3H and CBA/CaJ) and exposed to three different charged nuclei of increasing LET (350 MeV/n Si, 350 MeV/n Ar and 600 MeV/n Fe) and X-ray. Our data brings strong evidence against the classic "contact-first" model where DSBs are assumed to be immobile and repaired at the lesion site. In contrast, our model suggests nearby DSBs move into single repair unit characterized by large RIF before the repair machinery kicks in. Such model has the advantage of being much more efficient molecularly but is poorly suited to deal with cosmic radiation, where energy is concentrated along the particle trajectory, inducing a large density of DSBs along each particle track. In accordance with this model, RIF quantification after X-ray exposition showed a saturated dose response for early time points post-irradiation for all strains. Similarly, the high-LET response showed that RIF number matched the number of track per cell, not the number of expected DSB per cell (1). At the temporal level, we noted that the percentage of unrepaired high-LET tracks over a 48 hour time-course increased with LET, confirming that the DNA repair process becomes more difficult as more DSB coalesce into single RIF. There was also good agreement between persistent RIF levels measured in-vitro in the primary skin cultures and survival levels of T-cells and B-cells collected in blood samples from 10 CC strains 24 hours after 0.1 Gy whole-body dose of X-ray. This suggests that persistent RIF 24 hour post-IR is a good surrogate in-vitro biomarker for in-vivo radiation toxicity. Finally, at the genomic level, large differences in repair rates between strains for high-LET allowed us to identify suggestive genetic loci associated with radiation sensitivity. Interestingly, the two highest LETs provided the most strain variation with a common locus on Chromosome 10 highly enriched for DNA repair associated genes we discussed in detail.

Radiation-Induced Foci↗

Characterization of nuclear breakup as a function of hard-scattering kinematics using dijets measured by ATLAS in p+Pb collisions

This Letter analyzes the sensitivity of event geometry estimators to the initial-state kinematics of hard scattering in proton–lead collisions. This analysis uses dijets as a proxy for the parton–parton scattering configuration, correlating it with event geometry estimators, namely the energy deposited in the Zero-Degree Calorimeter and the transverse energy recorded in the Forward Calorimeter in the Pb-going direction. The analysis uses data recorded by the ATLAS detector at the Large Hadron Collider with a nucleon–nucleon center-of-mass energy of 8.16 TeV, corresponding to an integrated luminosity of 56 nb − 1 . The jets are measured within the pseudorapidity interval −2.8 < η < 4.5, where positive η values correspond to the direction of the proton beam. Results are presented as a function of the Bjorken-x of the parton originating from the proton, xp . Both event geometry estimators are found to be dependent on xp , with the energy deposited in the Zero-Degree Calorimeter about six times less sensitive to xp compared with the transverse energy deposited in the Forward Calorimeter.

Aad, G↗

Integrated Process Testing of MSR Salt Spill Accidents

Part of the licensing process for new nuclear reactors requires vendors to assess the potential consequences of identified accident scenarios using accident progression modeling. The accident scenario that will likely be evaluated by all molten salt reactor (MSR) developers is a spill of radionuclide-bearing fuel salt onto the reactor containment floor (i.e., a salt spill accident). The development of accident progression models requires experimental data to inform which processes to incorporate, to enable the calculation of parameters to model these processes, and to validate the model predictions. The data should quantify the sensitivities of key processes (e.g., molten salt spreading, heat transfer, containment structure corrosion, radionuclide vaporization, and aerosol generation) towards the initial conditions of the spill, the ambient environment, and the features of the containment. In addition, results from integrated process tests that quantify coupled processes are required to validate systems-level models. This report documents results from integrated process tests conducted on simulated molten salt spill accidents. The generated experimental data simultaneously quantify the heat transfer behavior of the spilled salt, compositional changes to the bulk salt, and the release of surrogate fission products from the spilled salt as aerosol particles. All tests that were conducted used FLiNaK doped with surrogate fission products, and the variables that were evaluated included the initial salt temperature and the concentration of surrogate fission products present in the salt. The major accomplishments of this work include identifying surrogate fuel salt compositions that provide insight into the dispersal behavior of radionuclides of potential significance to the source term, employing previously developed methods and measurement techniques to simultaneously measure key processes, generating data on the coupled processes of molten salt heat transfer and surrogate fission product release as aerosol particles, demonstrating new test methods for real-time monitoring of the flow rate of the spill and aerosol size quantification in an argon atmosphere, and developing a mass transfer model for cesium and iodine release from molten FLiNaK to provide insight into aerosol formation by vapor condensation. The same methodology applied herein can be employed to study different salt compositions of interest to MSR developers, different environmental conditions, and other variables that are relevant to postulated accident scenarios. The insights gained from these integrated process tests conducted at a laboratory scale will be incorporated into future integral effects tests conducted at an engineering scale.

20 FOSSIL-FUELED POWER PLANTS↗

Analysis of Polarimetry Data with Angular Uncertainties

For a track based polarimeter, such as the Imaging X-ray Polarimetry Explorer (IXPE), the sensitivity to polarization depends on the modulation factor, which is a strong function of energy. In previous work, a likelihood method was developed that would account for this variation in order to estimate the minimum detectable polarization (MDP). That method essentially required that the position angles of individual events should be known precisely. In a separate work, however, it was shown that using a machine-learning method for measuring event tracks can generate track angle uncertainties, which can be used in the analysis. Here, the maximum likelihood method is used as a basis for revising the estimate of the MDP in a general way that can include uncertainties in event track position angles. The resultant MDP depends solely upon the distribution of track angle uncertainties present in the input data. Due to the physics of the IXPE detectors, it is possible to derive a simple relationship between these angular uncertainties and the energy-dependent modulation function as a step in the process.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Compendium of Current Single Event Effects for Candidate Spacecraft Electronics for NASA

NASA spacecraft are subjected to a harsh space environment that includes exposure to various types of ionizing radiation. The performance of electronic devices in a space radiation environment are often limited by their susceptibility to single event effects (SEE). Ground-based testing is used to evaluate candidate spacecraft electronics to determine risk to spaceflight applications. Interpreting the results of radiation testing of complex devices is and adequate understanding of the test condition is critical. Studies discussed herein were undertaken to establish the application-specific sensitivities of candidate spacecraft and emerging electronic devices to single-event upset (SEU), single-event latchup (SEL), single-event gate rupture (SEGR), single-event burnout (SEB), and single-event transient (SET). For total ionizing dose (TID) and displacement damage dose (DDD) results, see a companion paper submitted to the 2015 Institute of Electrical and Electronics Engineers (IEEE) Nuclear and Space Radiation Effects Conference (NSREC) Radiation Effects Data Workshop (REDW) entitled "compendium of Current Total Ionizing Dose and Displacement Damage for Candidate Spacecraft Electronics for NASA by M. Campola, et al.

spacecraft electronics↗

Measuring differential particle correlations in relativistic nuclear collisions

This study explores the transverse momentum ( p T ) dependencies of symmetric and asymmetric correlations (SC and ASC) with one and two particles of interest in Au + Au collisions at 200 GeV. Leveraging a multiphase transport (AMPT) model, the investigation delves into the sensitivity of these correlations to the final state effects, providing valuable insights into their potential for constraining the final state effects' p T dependencies. The HIJING model is employed as a benchmark for nonflow correlations, shedding light on their impact on interpreting SC and ASC data. Moreover, the study points out that differential SC and ASC with one and two particles of interest (POIs) typically incorporate contributions from event-plane angle fluctuations. Consequently, this work highlights the significance of SC and ASC with one and two POIs as valuable tools for investigating the p T nature of the final state effects and advocates for comprehensive experimental measurements across various beam energies and system sizes to enhance understanding and provide additional constraints for theoretical models. Published by the American Physical Society 2024

Physics↗

Development of a U-19Pu-10Zr fuel performance benchmark case based on the IFR-1 experiment

Metallic nuclear fuels are subject to research and development for use in advanced reactors. Robust, accurate metallic fuel performance models are important for the design, safety analysis, and licensing of these reactors. However, metallic fuel performance models require additional development; they are not as mature as UO 2 fuel performance models. A benchmark case based on the IFR-1 experiment was developed to better gauge the accuracy of existing models, identify models for high-priority development, and potentially quantify any future improvements made by further model development.This work collected publicly available information on the IFR-1 experiment and used it to develop the benchmark case. Fuel behavior during the IFR-1 irradiation was simulated by using the fuel performance code BISON, and the predicted results were compared with postirradiation examination data from the IFR-1 experiment. Furthermore, a sensitivity study and tuning studies were performed as a preliminary investigation into the causes of inaccurate temperature and dimensional change predictions.The benchmark predicted reasonably accurate values for the burnup and fission gas release. There was error in the predicted temperatures, which could be explained by uncertainty in the input parameters and legacy temperatures. BISON over-predicted dimensional changes in the fuel and cladding. The sensitivity study showed that the dimensional changes were most sensitive to the fuel swelling anisotropy and the cladding void swelling model. Future benchmark and model development should focus on cladding swelling behaviors to improve dimensional change predictions.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Multi-track reconstruction algorithm in the Mu2e experiment

The Mu2e experiment, under construction at Fermilab, will search for the neutrino-less coherent $\mu^-N\rightarrow e^-N$ conversion in the field of a $^{27}$Al nucleus. Such a process violates lepton flavor conservation. About $60\%$ of muons stopped by an $^{27}$Al nucleus will undergo nuclear capture, while about $40\%$ will decay in orbit. To quantify the conversion probability, we define $R_{\mu e}$, which is given by the ratio between the $\mu^-\rightarrow e^-$ conversion rate and the nuclear capture rate [1]: \begin{equation} R_{\mu e}= \frac{\Gamma\left(\mu^- + N\left(Z,A\right)\rightarrow e^- + N\left(Z,A\right)\right)}{\Gamma\left(\mu^- + N\left(Z,A\right)\rightarrow \nu^-_\mu + N\left(Z-1,A\right)\right)}\,. \end{equation} The upper limit on $R_{\mu e}$ is $7\cdot 10^{-13}$ at $90\%$ CL, set by the SINDRUM II experiment~\cite{SINDRUM II:limit}. The goal of the Mu2e experiment is to reach a sensitivity on $R_{\mu e}$ of $8\cdot 10^{-17}$ at $90\%$ CL. This represents a four-order of magnitude improvement over the current experimental limit. Mu2e will take its first data in 2027. The signature for the muon conversion is a monochromatic electron of $104.97$~\si{\mega\eV}/c, an energy slightly below the muon rest mass. While the main experiment goal is to reconstruct the conversion electron, i.e., an event with a single track, there are motivations to develop an efficient tracking algorithm for reconstructing more simultaneous tracks. This could better constrain the background generated by $p\bar{p}$-annihilation in the Al target and to search for other Beyond the Standard Model processes. In this paper, we present an algorithm designed to reconstruct multi-particle events.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

LABS: Los Alamos Benchmark Suite - Current status and planning [Slides]

The LABS repository now has over 500 verified and revised input files with about 600 input files left to get up to speed with what we currently use. After that there are many, many more to go. We're in the process of building code infrastructure, moving to template output files, automating input file generation, outputting file data mining for calculation results, and benchmarking selection on sensitivity and other benchmark characteristics. We intend to open source LABS. We'll most likely release the input files sooner rather than later. The associated tool will probably be open sourced later.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Implementation of stacked ensemble machine learning for the detection of surrogate plutonium contamination in soil via LIBS

Supervised machine learning methods have demonstrated increased utility for the quantification of lanthanide and actinide elements in atomic spectroscopy applications. This study implements laser-induced breakdown spectroscopy (LIBS) for the identification of plutonium surrogate material (CeO 2 ) in soil matrices by training supervised machine learning methods on the recorded spectral data. A bagged ensemble using Random Forest yields the highest sensitivity predictions with a detection limit of 0.015 wt.% CeO 2 . However, high precision in Ce content prediction required the use of a stacked ensemble regression, which provided the superlative Ce quantification model with an error of 0.107% and a detection limit of 0.022 wt.%. Furthermore, the high performance of the stacked ensemble demonstrates its potential to enhance the accuracy and sensitivity of nuclear contaminant detection using field-deployable spectroscopic analyzers in real-world scenarios.

47 OTHER INSTRUMENTATION↗

The Athena Mars Rover Science Payload

The Mars Surveyor missions that will be launched in April of 2001 will include a highly capable rover that is a successor to the Mars Pathfinder mission's Sojourner rover. The design goals for this rover are a total traverse distance of at least 10 km and a total lifetime of at least one Earth year. The rover's job will be to explore a site in Mars' ancient terrain, searching for materials likely to preserve a record of ancient martian water, climate, and possibly biology. The rover will collect rock and soil samples, and will store them for return to Earth by a subsequent Mars Surveyor mission in 2005. The Athena Mars rover science payload is the suite of scientific instruments and sample collection tools that will be used to perform this job. The specific science objectives that NASA has identified for the '01 rover payload are to: (1) Provide color stereo imaging of martian surface environments, and remotely-sensed point discrimination of mineralogical composition. (2) Determine the elemental and mineralogical composition of martian surface materials. (3) Determine the fine-scale textural properties of these materials. (4) Collect and store samples. The Athena payload has been designed to meet these objectives. The focus of the design is on field operations: making sure the rover can locate, characterize, and collect scientifically important samples in a dusty, dirty, real-world environment. The topography, morphology, and mineralogy of the scene around the rover will be revealed by Pancam/Mini-TES, an integrated imager and IR spectrometer. Pancam views the surface around the rover in stereo and color. It uses two high-resolution cameras that are identical in most respects to the rover's navigation cameras. The detectors are low-power, low-mass active pixel sensors with on-chip 12-bit analog-to-digital conversion. Filters provide 8-12 color spectral bandpasses over the spectral region from 0.4 to 1.1 micron Narrow-angle optics provide an angular resolution of 0.28 mrad/pixel, nearly a factor of four higher than that of the Mars Pathfinder and Mars Surveyor '98 cameras. Image compression will be performed using a wavelet compression algorithm. The Mini-Thermal Emission Spectrometer (Mini-TES) is a point spectrometer operating in -the thermal IR. It produces high spectral resolution (5 /cm) image cubes with a wavelength range of 5-40 gm, a nominal signal/noise ratio of 500:1, and a maximum angular resolution of 7 mrad (7 cm at a distance of 10 in). The wavelength region over which it operates samples the diagnostic fundamental absorption features of rockforming minerals, and also provides some capability to see through dust coatings that could tend to obscure spectral features. The mineralogical information that Mini-TES provides will be used to select from a distance the rocks and soils that will be investigated in more detail and ultimately sampled. Mini-TES is derived from the MO/MGS TES instrument, but is significantly smaller and simpler. The instrument uses an 8-cm Cassegrain telescope, a Michelson interferometer, and uncooled pyroelectric detectors. Along with its mineralogical capabilities, Mini-TES can provide information on the thermophysical properties of rocks and soils. Viewing upward, it can also provide temperature profiles through the martian atmospheric boundary layer. Elemental and Mineralogical Composition: Once promising samples have been identified from a distance using Pancam/Mini-TES, they will be studied in detail using up to three compositional sensors that can be placed directly against them by an Instrument Arm. The two compositional sensors, presently on the payload are an Alpha-Proton-X-Ray Spectrometer (APXS), and a Mossbauer Spectrometer. The APXS is derived closely from the instrument that flew on Mars Pathfinder. Radioactive alpha sources and three detection modes (alpha, proton, and x-ray) provide elemental abundances of rocks and soils to complement and constrain mineralogical data. The Athena APXS will have a revised mechanical design that will cut down significantly on backscattering of alpha particles from martian atmospheric carbon. It will also include a target of known elemental composition that will be used for calibration purposes. The Athena Mossbauer Spectrometer is a diagnostic instrument for the mineralogy and oxidation state of Fe-bearing phases, which are particularly important on Mars. The instrument measures the resonant absorption of gamma rays produced by a Co-57 source to determine splitting of nuclear energy levels in Fe atoms that is related to the electronic environment surrounding them. It has been under development for space flight for many years at the Technical University of Darmstadt. The Mossbauer Spectrometer (and the other arm instruments) will be able to view a small permanent magnet array that will attract magnetic particles in the martian soil. The payload may also include a Raman Spectrometer. If included, the Raman Spectrometer will provide precise identification of major and minor mineral phases. It requires no sample preparation, and is also sensitive to organics. Fine-Scale Texture: The Instrument Arm a also carries a Microscopic Imager that will obtain high-resolution monochromatic images of the same materials for which compositional data will be obtained. Its spatial resolution is 20 micron/pixel over a 1 cm depth of field, and 40 micron/pixel over a 1-cm depth of field. Like Pancam, it uses the same active pixel sensor detectors and electronics as the rover's navigation cameras. The Instrument Arm is a three degree-of-freedom arm that uses designs and components from the Mars Pathfinder and Mars Surveyor '98 projects. Its primary function is instrument positioning. Along with the instruments noted above, it also carries a brush that can be used to remove dust and other loose coatings from rocks. Sample Collection and Storage: Martian rock and soil samples will be collected using a low-power rotary coring drill called the Mini-Corer. An important characteristic of this device is that it can obtain intact samples of rock from up to 5 cm within strong boulders and bedrock, Nominal core dimensions are 8xl7 mm. The Mini-Corer drills a core to the commanded depth in a rock, shears it off, retains it, and extracts it. It can also acquire samples of loose soil, using soil sample cups that are pressed downward into loose material. The Mini-Corer can drill at angles from vertical to 45' off vertical. It has six interchangeable bits for long life. Mechanical damage to the sample during drilling is minimal, and heating is negligible. After acquisition, the sample may be viewed by the arm instruments, and/or placed in one of 104 compartments in the Sample Container. A subset of the acquired samples may be replaced with other samples obtained later if desired. The Sample Container has no moving parts, and is mounted external to the rover for easy removal by the Mars Surveyor 2005 flight system. Operation of the rover will make extensive use of automated onboard navigation and hazard avoidance capabilities. Otherwise, use of onboard autonomy is minimal. Data downlink capability is about 40 Mbit/sol, and the use of the Mars Surveyor '01 orbiter for data relay imposes a limit of at most two command cycles per sol. Because of the significant amount of time available between command cycles, all payload elements will be operated sequentially, rather than in parallel.; this approach also significantly simplifies operations and minimizes peak power usage. The landing site for the '01 rover has not been selected yet. Site selection will make as full use as possible of Mars Global Surveyor data, and will involve substantial input from the broad Mars science community. Summary: The following table describes the mass, power, providers, and key scientific objectives of all the major elements of the Athena payload. Additional Athena payload information may be found at: http://astrosun.tn.cornell.edu/athena/index.html. Additional information contained in the original.

Squyes, S. W.↗

Dynamical Aspects of the Quark Gluon Plasma

Shortly after the Big Bang the entire universe was filled with a nearly perfect fluid known as the Quark Gluon Plasma. Relativistic heavy ion collisions can now reproduce this fluid in the laboratory where the Quark Gluon Plasma exhibits a rapid but smooth cross-over phase transition into hadrons at vanishing net-baryon densities. Recent experiments plan to explore finite baryon densities where a critical point is expected. If found, this would mark the first discovery of a critical point in a relativistic system described by a fundamental theory of nature, which would have far-reaching consequences for high-energy nuclear physics and nuclear astrophysics (such as in neutron star mergers). Characteristic temperatures of equilibrium (e.g. the inflection point of the entropy density) and transport coefficients (e.g. minimum of the shear viscosity over entropy density) vary widely at a cross-over phase transition but converge at a critical point, and extracting the behavior of these characteristic temperatures is a major focal point of this research. Specifically, the interplay between strange and light hadrons is exploited to study the flavor hierarchy in the cross-over region. To investigate this, a viscous relativistic hydrodynamics framework with two conserved charges is being developed into a new open-source code along with initial conditions that contain baryon number and strangeness. Flow observables sensitive to the equation of state and transport coefficients are calculated across beam energies. New techniques are being developed to study this flavor hierarchy from first principles and to extract the characteristic temperatures from experimental data. Through this new dynamical framework, this project provides essential guidance to the Beam Energy Scan II runs at Relativistic Heavy-Ion Collider and the future Facility for Antiproton and Ion Research facility in the search for the Quantum Chromodynamic critical point and subsequent investigation of the baryon-rich Quark Gluon Plasma.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Evidence against the Efimov effect in 12 C from spectroscopy and astrophysics

Background: The Efimov effect is a universal phenomenon in physics whereby three-body systems are stabilized via the interaction of an unbound two-body subsystems. A hypothetical state in 12 C at 7.458-MeV excitation energy, comprising a loose structure of three α particles in mutual two-body resonance, has been suggested in the literature to correspond to an Efimov state in nuclear physics. The existence of such a state has not been demonstrated experimentally. Purpose: Using a combination of γ spectroscopy, charged-particle spectroscopy, and astrophysical rate calculations allowing for strict limits on the existence of such a state to been established here. Method: Using the combined data sets from two recent experiments, one with the TexAT (Texas Active Target) TPC (Time Projection Chamber) to measure α decay and the other with Gammasphere to measure γ decay of states in 12 C populated by 12 N and 12 B β decay, respectively, we achieve high sensitivity to states in close proximity to the α threshold in 12 C. Results: No evidence of a state at 7.458 MeV is seen in either data set. Using a likelihood method, the 95% confidence limit γ -decay branching ratio is determined as a function of the β-decay feeding strength relative to the Hoyle state. In parallel, calculations of the 3α reaction rate show the inclusion of the Efimov corresponds to a large increase in the reaction rate around 5 × 10 7 K. Conclusion: From decay spectroscopy—at the 95% confidence limit, the Efimov state cannot exist at 7.458 MeV with any γ-decay branching ratio unless the β strength is less than 0.7% of the Hoyle state. This limit is evaluated for a range of different excitation energies and the results are not favorable for existence of the hypothetical Efimov state in 12 C . Furthermore, the 3α reaction rate with the inclusion of a state between 7.43 and 7.53 MeV exceeds the rate required for stars to undergo the red giant phase.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Validation of SAS4A/SASSYS-1 for predicting steady-state single-phase natural circulation

The validation of system analysis codes for nuclear reactor systems is required for the development and application of these computational tools. Designed as a comprehensive system analysis code for advanced nuclear reactors, SAS4A/SASSYS-1 requires validation of its physics model for capturing single-phase natural circulation behavior. To support the validation of SAS4A/SASSYS-1, high-precision experiments are performed capturing steady-state single-phase natural circulation on a scaled facility with comprehensive instrumentation. In this work, dedicated tests are performed quantifying the critical modeling parameters, and a single-phase natural circulation benchmark dataset is obtained with well-documented uncertainty and comprehensive facility description. The validation is then performed against the dataset examining the capability of SAS4A/SASSYS-1 in simulating steady-state single-phase natural circulation. The experimental facility is modeled in the candidate code. Solution verification is performed using Richardson-extrapolation-based estimators which quantify and restrict numerical errors from discretization. Input uncertainty provided by the benchmark dataset is forward propagated through the candidate code, quantifying the output uncertainty in a Monte Carlo approach. The composition of the output uncertainty is also quantified through a variance-based sensitivity analysis. With the uncertainty quantified for each individual condition, a detailed comparison between the simulation results and experimental data is performed covering the whole dataset. The results show consistent agreement for all primary parameters. The current validation activity provides a valuable benchmark dataset for the validation of system analysis codes in capturing single-phase natural circulation and demonstrates satisfactory prediction capability of SAS4A/SASSYS1 for steady-state single-phase natural circulation.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Demonstration of acoustic monitoring for structural health of microreactors: Through use of neural networks and resonant ultrasound spectroscopy

Nuclear microreactors prioritize modularity and portability and are intended to be a cost-effective technology for non-conventional nuclear markets. As such, the development of microreactors into a safe and feasible solution for energy security applications will necessitate the development of non-destructive technologies to monitor the integrity of inaccessible reactors components during operation. This demonstration applies linear and nonlinear acoustic techniques, in combination with machine learning, to detect and classify mechanical changes (stress and damage) in a test article which are broadly representative of potential operating challenges within a functioning microreactor. All necessary data has been collected for this demonstration, with minor experimental issues identified that can be addressed in follow-on work. Motivated by the expected conditions within a functioning microreactor, we have demonstrated our monitoring techniques on a core-block-like test article using an unstructured excitation source that approximates the noisy acoustic environment expected during reactor operation. At all stress states mechanically applied to the test article, a machine learning model using an artificial neural network was able to classify with 100% accuracy whether a 3D laser vibrometry point measurement was made on an intact or artificially defective test article. Further, model predictions about whether the defect interface was rough or smooth were 95% accurate, indicating the ability of acoustic techniques to recover defect characteristics. Resonant ultrasound spectroscopy (RUS) was also applied to the dataset to provide further quantitative insights about material properties. RUS analysis was ultimately hampered by several minor experimental and data issues, limiting results to certain cases for this demonstration. Last, analysis using nonlinear RUS exhibited sensitivity to changing levels of applied stresses for each intact and defective state. As presented in this demonstration, acoustic monitoring exhibits sensitivity to stress changes, which are of concern due to high thermal gradients expected during startup and operation. Further, our techniques distinguish between measurements made on intact and damaged test articles.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Benchmark evaluation of one dimensional array of HEU moderated and reflected by Lucite

The evaluation of two HEU-Lucite experiments is presented. The critical experiments were performed using the Planet Universal Critical Assembly Machine at Los Alamos National Laboratory in 2019. In these experiments, HEU foils were interleaved with Lucite in a column stack and were moderated and reflected from the square Lucite plates. The neutron data produced were used to approximate the multiplication of each measured configuration. The evaluation of the experiments using calculational techniques is presented in the paper. A Monte-Carlo computational model to be used with MCNP6 was developed for the determination of uncertainties and the effects of various uncertainties on the multiplication factor were studied. The evaluation of the benchmark was performed for comparison of calculation results with the experimental data and validation of calculation techniques in particular the newly available thermal scattering data for the Lucite material. The sensitivity studies include parametric variations of material composition and geometry. Experimental uncertainties were low, with the overall height of the HEU/Lucite stack being the largest contributor to the overall uncertainty in k{sub eff}. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗