Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Notes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Note: Measurement of the runaway electrons in the J-TEXT tokamak

The runaway electrons have been measured by hard x-ray detectors and soft x-ray array in the J-TEXT tokamak. The hard x-ray radiations in the energy ranges of 0.5-5 MeV are measured by two NaI detectors. The flux of lost runaway electrons can be obtained routinely. The soft x-ray array diagnostics are used to monitor the runaway beam generated in disruptions since the soft x-ray is dominated by the interaction between runaway electrons and metallic impurities inside the plasma. With the aid of soft x-ray array, runaway electron beam has been detected directly during the formation of runaway current plateau following the disruptions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Note: Emittance measurements of intense pulsed proton beam for different pulse length and repetition rate

The high intensity ion source (SILHI), in operation at CEA-Saclay, has been used to produce a 90 mA pulsed proton beam with pulse length and repetition rates suitable for the European Spallation Source (ESS) linac. Typical r-r{sup '} rms normalized emittance values smaller than 0.2{pi} mm mrad have been measured for operation in pulsed mode (0.01 < duty cycle < 0.15 and 1 ms < pulse duration < 10 ms) that are relevant for the design update of the Linac to be used at the ESS in Lund.

43 PARTICLE ACCELERATORS↗

Note: A sample holder design for sensitive magnetic measurements at high temperatures in a magnetic properties measurement system

A sample holder design for high temperature measurements in a commercial MPMS SQUID magnetometer from Quantum Design is presented. It fulfills the requirements for the simultaneous use of the oven and reciprocating sample option (RSO) options, thus allowing sensitive magnetic measurements up to 800 K. Alternating current susceptibility can also be measured, since the holder does not induce any phase shift relative to the ac driven field. It is easily fabricated by twisting Constantan Copyright-Sign wires into a braid nesting the sample inside. This design ensures that the sample be placed tightly into a tough holder with its orientation fixed, and prevents any sample displacement during the fast movements of the RSO transport, up to high temperatures.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Note: Grazing incidence small and wide angle x-ray scattering combined with imaging ellipsometry

The combination of grazing incidence small angle x-ray scattering (GISAXS) and grazing incidence wide angle x-ray scattering (GIWAXS) with optical imaging ellipsometry is presented as an upgrade of the available measurement techniques at the wiggler beamline BW4 of the Hamburger Synchrotronstrahlungslabor. The instrument is introduced with the description of the alignment procedure to assure the measurement of imaging ellipsometry and GISAXS/GIWAXS on the same sample spot. To demonstrate the possibilities of the new instrument examples of morphological investigation on films made of poly(3-hexylthiophene) and [6,6]-phenyl-C{sub 61} butyric acid methyl ester as well as textured poly(9,9-dioctylfluorene-alt-benzo-thia-diazole) are shown.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Note: Rotaphone, a new self-calibrated six-degree-of-freedom seismic sensor

We have developed and tested (calibration, linearity, and cross-axis errors) a new six-degree-of-freedom mechanical seismic sensor for collocated measurements of three translational and three rotational ground motion velocity components. The device consists of standard geophones arranged in parallel pairs to detect spatial gradients. The instrument operates in a high-frequency range (above the natural frequency of the geophones, 4.5 Hz). Its theoretical sensitivity limit in this range is 10{sup -9} m/s in ground velocity and 10{sup -9} rad/s in rotation rate. Small size and weight, and easy installation and maintenance make the instrument useful for local-earthquake recording and seismic prospecting.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Note: Statistical errors estimation for Thomson scattering diagnostics

A practical way of estimating statistical errors of a Thomson scattering diagnostic measuring plasma electron temperature and density is described. Analytically derived expressions are successfully tested with Monte Carlo simulations and implemented in an automatic data processing code of the JET LIDAR diagnostic.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Note: Comparison of grazing incidence small angle x-ray scattering of a titania sponge structure at the beamlines BW4 (DORIS III) and P03 (PETRA III)

Grazing incidence small angle x-ray scattering (GISAXS) is a powerful technique for morphology investigation of nanostructured thin films. GISAXS measurements at the newly installed P03 beamline at the storage ring PETRA III in Hamburg, Germany, are compared to the GISAXS data from the beamline BW4 at the storage ring DORIS III, which had been used extensively for GISAXS investigations in the past. As an example, a titania thin film sponge structure is investigated. Compared to BW4, at beamline P03 the resolution of larger structures is slightly improved and a higher incident flux leads to a factor of 750 in scattered intensity. Therefore, the acquisition time in GISAXS geometry is reduced significantly at beamline P03.

43 PARTICLE ACCELERATORS↗

Note: Laser frequency shifting by using two novel triple-pass acousto-optic modulator configurations

We report the design of two novel triple-pass acousto-optic modulator systems. These designs are extensions of the well known acousto-optic modulator (AOM) double-pass configuration, which eliminates the angle dependence of the diffracted beam with respect to the modulation frequency. In a triple-pass system, however, the frequency dependence of the angle does not disappear but the frequency shift is larger, spanning 3 times the AOM central frequency. In some applications, such as optically pumped Cesium-beam frequency standards, the frequencies of the two laser beams remain fixed and a triple-pass optical system can be used to reduce to one the number of lasers used in such atomic clocks. The two triple-pass configurations use either a retro-reflecting mirror, or a right angle prism to pass for third time the laser beam through the AOM, obtaining diffraction efficiencies of about 27% and 44%, respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Note: Precision viscosity measurement using suspended microchannel resonators

We report the characterization of a suspended microchannel resonator (SMR) for viscosity measurements in a low viscosity regime (<10 mPa s) using two measurement schemes. First, the quality factor (Q-factor) of the SMR was characterized with glycerol-water mixtures. The measured Q-factor at 20 Degree-Sign C exhibits a bilinear behavior with the sensitivity of 1281 (mPa s){sup -1} for a lower (1-4 mPa s) and 355 (mPa s){sup -1} for a higher viscosity range (4-8 mPa s), respectively. The second scheme is the vibration amplitude monitoring of the SMR running in a closed loop feedback. When compared in terms of the measurement time, the amplitude-based measurement takes only 0.1 {approx} 1 ms while the Q-factor-based measurement takes {approx}30 s. However, the viscosity resolution of the Q-factor-based measurement is at least three times better than the amplitude-based measurement. By comparing the Q-factors of heavy water and 9.65 wt.% glycerol-water mixture that have very similar viscosities but different densities, we confirmed that the SMR can measure the dynamic viscosity without the density correction. The obtained results demonstrate that the SMR can measure the fluid viscosity with high precision and even real-time monitoring of the viscosity change is possible with the amplitude-based measurement scheme.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Note: Helical nanobelt force sensors

We present the fabrication and characterization of helical nanobelt force sensors. These self-sensing force sensors are based on the giant piezoresistivity of helical nanobelts. The three-dimensional helical nanobelts are self-formed from 27 nm-thick n-type InGaAs/GaAs bilayers using rolled-up techniques, and assembled onto electrodes on a micropipette using nanorobotic manipulations. The helical nanobelt force sensors can be calibrated using a calibrated atomic force microscope cantilever system under scanning electron microscope. Thanks to their giant piezoresistance coefficient (515 Multiplication-Sign 10{sup -10} Pa{sup -1}), low stiffness (0.03125 N/m), large-displacement capability ({approx}10 {mu}m), and good fatigue resistance, they are well suited to function as stand-alone, compact ({approx}20 {mu}m without the plug-in support), light ({approx}5 g including the plug-in support), versatile and large range ({approx}{mu}N) and high resolution ({approx}nN) force sensors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Note: Excited State Studies of Ozone using State-Specific Multireference Coupled Cluster Methods

Vertical excitation energies obtained with state-specific multi-reference coupled cluster (MRCC) methods are reported for the ozone molecule. Using state-specific MRCC non-iterative methods with singles, doubles, and non-iterative triples (MRCCSD(T)) we obtain 4.40 eV for the challenging doubly excited 21A1 state when using a reliable model space. This estimate is in good agreement with experiment (4.5 eV). We also compare our MRCC results with the excitation energies obtained with high-order equation-of-motion coupled cluster methods

ab initio↗

Note. Switch-Mode Hybrid Current Controllers for Quantum Cascade Lasers

Chemical sensing in the mid-infrared has been revolutionized by the advent of quantum cascade lasers. Their higher current and voltage demands compared to laser diodes however, negatively impact size, weight and power footprint for fieldable systems, particularly in hot environments. This letter presents a switch-mode/linear hybrid controller design, furnishing low-noise drive current up to 2 amperes at compliance voltages up to 15 volts, with noise levels close to the Johnson noise of the internal resistors. Current modulation from near zero to 1.8 Amps is also demonstrated at frequencies up to a kilohertz.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗