EXPRES. I. HD 3651 as an Ideal RV Benchmark

The next generation of exoplanet-hunting spectrographs should deliver up to an order of magnitude improvement in radial velocity (RV) precision over the standard 1 m s{sup −1} state-of-the-art spectrographs. This advance is critical for enabling the detection of Earth-mass planets around Sun-like stars. New calibration techniques such as laser frequency combs and stabilized etalons ensure that the instrumental stability is well characterized. However, additional sources of error include stellar noise, undetected short-period planets, and telluric contamination. To understand and ultimately mitigate error sources, the contributing terms in the error budget must be isolated to the greatest extent possible. Here, we introduce a new high-cadence RV program, the Extreme Precision Spectrograph (EXPRES) 100 Earths Survey, which aims to identify rocky planets around bright, nearby G and K dwarfs. We also present a benchmark case: the 62 day orbit of a Saturn-mass planet orbiting the chromospherically quiet star, HD 3651. The combination of high eccentricity (0.6) and a moderately long orbital period ensures significant dynamical clearing of any inner planets. Our Keplerian model for this planetary orbit has a residual rms of 58 cm s{sup −1} over a ∼6 month time baseline. By eliminating significant contributors to the RV error budget, HD 3651 serves as a standard for evaluating the long-term precision of extreme precision RV programs.

79 ASTRONOMY AND ASTROPHYSICS↗

Study on spectral/radiometric characteristics of the Thematic Mapper for land use applications

Previous characterization of scan-related low-frequency noise was extended and refined through detailed analysis of shutter calibration data on CCT-ADDS tapes and reflective-band data from nighttime acquisitions. A recommended correction procedure was identified that uses calibration shutter data both as a diagnostic and to obtain correction values. Through comparison of coincident TM and MSS data, illustrations of the added information content of TM data for agricultural applications were developed. The capability of improved spatial resolution to better define boundaries and to resolve spatial details is shown. Spectral analysis of tasseled-cap transformations of TM and MSS data shows high correlation between greenness features, greater signal range for TM, and indications that a subset of TM bands could accurately simulate MSS data, if required.

Malila, W. A.↗

Two AFC Loops For Low CNR And High Dynamics

Two alternative digital automatic-frequency-control (AFC) loops proposed to acquire (or reacquire) and track frequency of received carrier radio signal. Intended for use where carrier-to-noise ratios (CNR's) low and carrier frequency characterized by high Doppler shift and Doppler rate because of high relative speed and acceleration, respectively, between transmitter and receiver. Either AFC loops used in place of phase-locked loop. New loop concepts integrate ideas from classical spectrum-estimation, digital-phase-locked-loop, and Kalman-Filter theories.

Hinedi, Sami M.↗

Interstellar detection of the intersystem line Si II lambda 2335 toward zeta Ophiuchi

We report on the detection of the weak intersystem transistion of Si II lambda 2335 A in the sight line toward zeta Oph using the Ech-B mode (3.5 km/s resolution) of the Goddard High Resolution Spectrograph. The high-quality spectrum is characterized by an empirically measured signal-to-noise of 450, in excellent agreement with that expected from photon-statistics. The measured equivalent width of the Si II line is W(sub lambda) = 0.48 +/- 0.12 mA. Using the new experimental f-value of Calamai, Smith, and Bergeson, we find a Si II column density of 2.34 (+/- 0.58) x 10(exp 15) atoms/sq cm and (Si/H)(sub zeta Oph) = 1.78 (+/- 0.44) x 10(exp -6) for the principal absorbing component(s) at v(sub sun) approx. = -15 km/s. Analysis of the Si II lambda 1808 absorption over the same velocity range using the new experimental f-value of Bergeson & Lawler yields a column density (corrected for saturation) that is consistent within the weak line errors and confirms the relative accuracies of these new f-values. Furthermore, these results indicate that accurate abundances can now be derived for Si II, particularly from the weak Si II lambda 2335 A since it is free of saturation effects. For the zeta Oph v(sub sun) approx. = -15 km/s component(s), we find that greater than 95% of the available cosmic abundance (i.e. the 1989 meteoritic abundances of Anders & Grevesse) of Mg, Fe, and Si is 'missing' from the gas phase and is presumably locked up in the dust. These elements are present in the dust grains in ratios of Fe/Si approximately equals 0.9 and Mg/Si approximately equals 1.1, consistent with the ratio of their cosmic abundances. These ratios are in sharp contrast to more diffuse clouds like those seen toward the high-latitude halo star HD 93521 where in the dust Fe/Si approximately equals 1.8 and Mg/Si approximately equals 2.1.

Cardelli, Jason A.↗

Performance of Small Pore Microchannel Plates

Small pore size microchannel plates (MCP's) are needed to satisfy the requirements for future high resolution small and large format detectors for astronomy. MCP's with pore sizes in the range 5 micron to 8 micron are now being manufactured, but they are of limited availability and are of small size. We have obtained sets of Galileo 8 micron and 6.5 micron MCP's, and Philips 6 micron and 7 micron pore MCP's, and compared them to our larger pore MCP Z stacks. We have tested back to back MCP stacks of four of these MCP's and achieved gains greater than 2 x 1O(exp 7) with pulse height distributions of less than 40% FWHM, and background rates of less than 0.3 events sec(exp -1) cm(exp -2). Local counting rates up to approx. 100 events/pore/sec have been attained with little drop of the MCP gain. The bare MCP quantum efficiencies are somewhat lower than those expected, however. Flat field images are characterized by an absence of MCP fixed pattern noise.

Siegmund, O. H. W.↗

Characterization of Photoreceivers for LISA

LISA will use quadrant photo receivers as front-end devices for the phase meter measuring the motion of drag-free test masses in both angular orientation and separation. We have set up a laboratory testbed for the characterization of photo receivers. Some of the limiting noise sources have been identified and their contribution has been either measured or determined from the measured data. We have built a photo receiver with a 0.5 mm diameter quadrant photodiode with an equivalent input noise of better than 1.8 pA/(square root of)Hz below 20 MHz and a 3 dB bandwidth of 34 MHz.

Cervantes, F. Guzman↗

The Design, Implementation, and Performance of the Astro-H SXS Aperture Assembly and Blocking Filters

The calorimeter array of the JAXA Astro-H (renamed Hitomi) Soft X-ray Spectrometer (SXS) was designed to provide unprecedented spectral resolution of spatially extended cosmic x-ray sources and of all cosmic x-ray sources in the Fe-K band around 6 keV, enabling essential plasma diagnostics. The properties that make the SXS array a powerful x-ray spectrometer also make it sensitive to photons from the entire electromagnetic band, and particles as well. If characterized as a bolometer, it would have a noise equivalent power (NEP) of less than 4x10(exp -18) W/(Hz)0.5(exp 0.5). Thus it was imperative to shield the detector from thermal radiation from the instrument and optical and UV photons from the sky. Additionally, it was necessary to shield the coldest stages of the instrument from the thermal radiation emanating from the warmer stages. Both of these needs are addressed by a series of five thin-film radiation-blocking filters, anchored to the nested temperature stages, that block long-wavelength radiation while minimizing x-ray attenuation. The aperture assembly is a system of barriers, baffles, filter carriers, and filter mounts that supports the filters and inhibits their potential contamination. The three outer filters also have been equipped with thermometers and heaters for decontamination. We present the requirements, design, implementation, and performance of the SXS aperture assembly and blocking filters.

radiation - blocking filters↗

The Design, Implementation, and Performance of the Astro-H SXS Aperture Assembly and Blocking Filters

The calorimeter array of the JAXA Astro-H (renamed Hitomi) Soft X-ray Spectrometer (SXS) was designed to provide unprecedented spectral resolution of spatially extended cosmic x-ray sources and of all cosmic x-ray sources in the Fe-K band around 6 keV. The properties that make the SXS a powerful x-ray spectrometer also make it sensitive to the entire electromagnetic band. If characterized as a bolometer, it would have a noise equivalent power (NEP) of < 4x10(exp -18) W/(Hz)0.5. Thus it was imperative to shield the detector from thermal radiation from the instrument and optical and UV photons from the sky. Additionally, it was necessary to shield the coldest stages of the instrument from the thermal radiation emanating from the warmer stages. These needs are addressed by a series of five thin-film radiation blocking filters that block long-wavelength radiation while minimizing x-ray attenuation. The SXS aperture assembly is a system of barriers, baffles, filter carriers, and filter mounts that supports the filters and inhibits their potential contamination. The three warmer filters also were equipped with thermometers and heaters for decontamination.

microcalorimeter↗

H2RG Detector Characterization for RIMAS and Instrument Efficiencies

The Rapid infrared IMAger-Spectrometer (RIMAS) is a near-infrared (NIR) imager and spectrometer that will quickly follow up gamma-ray burst afterglows on the 4.3-meter Discovery Channel Telescope (DCT). RIMAS has two optical arms which allows simultaneous coverage over two bandpasses (YJ and HK) in either imaging or spectroscopy mode. RIMAS utilizes two Teledyne HgCdTe H2RG detectors controlled by Astronomical Research Cameras, Inc. (ARC/Leach) drivers. We report the laboratory characterization of RIMAS's detectors: conversion gain, read noise, linearity, saturation, dynamic range, and dark current. We also present RIMAS's instrument efficiency from atmospheric transmission models and optics data (both telescope and instrument) in all three observing modes.

Toy, Vicki L.↗

The Bidirectional Reflectance of Black Silicon Used in Space and Earth Remote Sensing Applications

Space-based astrophysical and remote sensing observations often require the detection and measurement of light originating from distant and relatively faint objects. These observations are highly susceptible to scattered light which may introduce imaging artifacts, obscure object details, and increase measurement noise. This paper describes the initial work of characterizing representative black materials used in coronagraph instruments and other spaceborne instruments. Measurements of “blackness” and the achieved reflectance of black silicon are provided in the spectral range from 400nm to 2500nm using 8o directional hemispherical measurements. The bidirectional reflectance of black silicon was also measured at discrete wavelengths, 633nm, and 1064nm, using the optical scatterometer located at NASA Goddard Space Flight Center’s Diffuser Calibration Laboratory (DCL). A 100mm diameter black silicon sample was fabricated and optically characterized. The BRDF of other well-known black materials such as Z306 and Fractal Black are also presented and discussed.

Georgiev, Georgi T.↗

The Bidirectional Reflectance of Black Silicon Used in Space and Earth Remote Sensing Applications

Space-based astrophysical and remote sensing observations often require the detection and measurement of light originating from distant and relatively faint objects. These observations are highly susceptible to scattered light which may introduce imaging artifacts, obscure object details, and increase measurement noise. This paper describes the initial work of characterizing representative black materials used in coronagraph instruments and other spaceborne instruments. Measurements of “blackness” and the achieved reflectance of black silicon are provided in the spectral range from 400nm to 2500nm using 8o directional hemispherical measurements. The bidirectional reflectance of black silicon was also measured at discrete wavelengths, 633nm, and 1064nm, using the optical scatterometer located at NASA Goddard Space Flight Center’s Diffuser Calibration Laboratory (DCL). A 100mm diameter black silicon sample was fabricated and optically characterized. The BRDF of other well-known black materials such as Z306 and Fractal Black are also presented and discussed.

Georgiev, Georgi T.↗

The Bidirectional Reflectance of Black Silicon Used in Space and Earth Remote Sensing Applications

Space-based astrophysical and remote sensing observations often require the detection and measurement of light originating from distant and relatively faint objects. These observations are highly susceptible to scattered light which may introduce imaging artifacts, obscure object details, and increase measurement noise. This paper describes the initial work of characterizing representative black materials used in coronagraph instruments and other spaceborne instruments. Measurements of “blackness” and the achieved reflectance of black silicon are provided in the spectral range from 400nm to 2500nm using 8o directional hemispherical measurements. The bidirectional reflectance of black silicon was also measured at discrete wavelengths, 633nm, and 1064nm, using the optical scatterometer located at NASA Goddard Space Flight Center’s Diffuser Calibration Laboratory (DCL). A 100mm diameter black silicon sample was fabricated and optically characterized. The BRDF of other well-known black materials such as Z306 and Fractal Black are also presented and discussed.

BRDF↗

A Vector Sensor-Based Acoustic Characterization System for Marine Renewable Energy

NoiseSpotter is a passive acoustic monitoring system that characterizes, classifies, and geo-locates anthropogenic and natural sounds in near real time. It was developed with the primary goal of supporting the evaluation of potential acoustic effects of offshore renewable energy projects. The system consists of a compact array of three acoustic vector sensors, which measures acoustic pressure and the three-dimensional particle velocity vector associated with the propagation of an acoustic wave, thereby inherently providing bearing information to an underwater source of sound. By utilizing an array of three vector sensors, the application of beamforming techniques can provide sound source localization, allowing for characterization of the acoustic signature of specific underwater acoustic sources. Here, performance characteristics of the system are presented, using data from controlled acoustic transmissions in a quiet environment and ambient noise measurements in an energetic tidal channel in the presence of non-acoustic flow noise. Data quality is demonstrated by the ability to reduce non-acoustic flow noise contamination, while system utility is shown by the ability to characterize and localize sources of sound in the underwater environment.

16 TIDAL AND WAVE POWER↗

Characterization of the Reverberation Chamber at the NASA Langley Structural Acoustics Loads and Transmission (SALT) Facility

In 2011 the noise generating capabilities in the reverberation chamber of the Structural Acoustic Loads and Transmission (SALT) facility at NASA Langley Research Center were enhanced with two fiberglass reinforced polyester resin exponential horns, each coupled to Wyle Acoustic Source WAS-3000 airstream modulators. This report describes the characterization of the reverberation chamber in terms of the background noise, diffusivity, sound pressure levels, the reverberation times and the related overall acoustic absorption in the empty chamber and with the acoustic horn(s) installed. The frequency range of interest includes the 80 Hz to 8000 Hz one-third octave bands. Reverberation time and sound pressure level measurements were conducted and standard deviations from the mean were computed. It was concluded that a diffuse field could be produced above the Schroeder frequency in the 400 Hz one-third octave band and higher for all applications. This frequency could be lowered by installing panel diffusers or moving vanes to improve the acoustic modal overlap in the chamber. In the 80 Hz to 400 Hz one-third octave bands a successful measurement will be dependent on the type of measurement, the test configuration, the source and microphone locations and the desired accuracy. It is recommended that qualification measurements endorsed in the International Standards be conducted for each particular application.

Grosveld, Ferdinand W.↗

A novel electron tunneling infrared detector

The pneumatic infrared detector, originally developed by Golay in the late 1940s, uses the thermal expansion of one cm(exp 3) of xenon at room temperature to detect the heat deposited by infrared radiation. This detector was limited by thermal fluctuations within a 10 Hz bandwidth, but suffered from long thermal time constants and a fragile structure. Nevertheless, it represents the most sensitive room temperature detector currently available in the long wavelength infrared (LWIR). Fabrication of this type of detector on smaller scales has been limited by the lack of a suitably sensitive transducer. Researchers designed a detector based on this principle, but which is constructed entirely from micromachined silicon, and uses a vacuum tunneling transducer to detect the expansion of the trapped gas. Because this detector is fabricated using micromachining techniques, miniaturization and integration into one and two-dimensional arrays is feasible. The extreme sensitivity of vacuum tunneling to changes in electrode separation will allow a prototype of this detector to operate in the limit of thermal fluctuations over a 10 kHz bandwidth. A calculation of the predicted response and noise of the prototype is presented with the general formalism of thermal detectors. At present, most of the components of the prototype have been fabricated and tested independently. In particular, a characterization of the micromachined electron tunneling transducer has been carried out. The measured noise in the tunnel current is within a decade of the limit imposed by shot noise, and well below the requirements for the operation of an infrared detector with the predicted sensitivity. Assembly and characterization of the prototype infrared detector will be carried out promptly.

Kenny, T. W.↗

Test and characterization of finely segmented pixel CZT detectors for future hard x-ray missions

The NuSTAR (Nuclear Spectroscopic Telescope Array) mission was launched in 2012, and it has successfully deployed the first orbiting telescopes to focus high energy X-ray (3 - 79 keV) light, providing a wealth of new information on high-energy X-rays sources. Follow-up missions, such as the proposed HEX-P, BEST, and FORCE, could perform a deeper black hole census providing a more refined measurement of black hole spins, allowing for greater knowledge about supermassive black holes. Here, these missions are motivated by the recent breakthroughs in the hard X-ray mirror technologies, where mirrors, either made of monolithic silicon segments, or made directly or via replication of shells, demonstrate the feasibility of making hard X-ray mirrors with angular resolutions of 5-10 arc-seconds Half Power Diameter (HPD) compared to the NuSTAR’s 1 arc-minute HPD. Such a high angular resolution requires matched detectors with higher degree of segmentation to fully benefit from the achievable improved spatial resolution. In the above framework, the HEXID ASIC, a novel pixelated front-end suitable for reading out a finely segmented CZT sensor with 150 μm pixel pitch in a hexagonal arrangement has been developed. This readout pixelated chip is capable of processing photon-generated charge packets over a large dynamic range (from 2 keV up to 180 keV), while keeping a low input noise (ENC <20 e - ). In this work, the initial characterization of the ASIC prototype will be presented.

47 OTHER INSTRUMENTATION↗

Nonlinearly stacked low noise turbofan stator

A nonlinearly stacked low noise turbofan stator vane having a characteristic curve that is characterized by a nonlinear sweep and a nonlinear lean is provided. The stator is in an axial fan or compressor turbomachinery stage that is comprised of a collection of vanes whose highly three-dimensional shape is selected to reduce rotor-stator and rotor-strut interaction noise while maintaining the aerodynamic and mechanical performance of the vane. The nonlinearly stacked low noise turbofan stator vane reduces noise associated with the fan stage of turbomachinery to improve environmental compatibility.

Schuster, William B.↗

Disorder to Order in Interface Patterns: Thermal Noise to Limit Cycle Transition in Dendrite Sidebranch Formation

Thin sample directional solidification experiments have been carried out in the model succinonitrile-camphor system to examine the origin of secondary branches in dendrite morphologies. Thermal noise at the dendrite tip creates interface instabilities which amplify to form sidebranches. This is accepted as the primary mode of sidebranching in dendritic growth from an undercooled melt and occurs in directional solidification of dendrites. The proposed limit cycle couples the growth of the tip with the initiation of the sidebranch. Directional solidification of curved interfaces is a driven dissipative system with the potential to form a limit cycle. Two sets of experiments were performed, the first holding velocity constant and evolving the gradient and the second imposing oscillating velocities around the natural period of sidebranching. Both experimental methods were found to characterize a transition from disordered sidebranching induced by thermal noise to ordered sidebranching produced by the limit cycle mechanisms. This is the first quantitative measurement of previously hypothesized limit cycle growth. These experiment sets have been quantitatively analyzed for dynamic behavior seen in limit cycles. High-quality data sets of the tip and instability enable the measurement of the FFT and analysis through a power spectrum. At low gradients, the sidebranches are found to be excited by thermal noise far away from the tip. As the gradient increases and velocity is held constant, the distance between the instability and tip decreases until limit cycle growth is found between the tip of the primary dendrite and the first forming sidebranch. An alternative to the deterministic limit cycles seen in experiments of gradient evolution is a limit cycle actively driven through the square wave oscillation of velocity. Crucial observations of the solidified microstructure conclude that this produced periodic interconnected bridges between the primary dendrites. This is a finding with potentially significant implications for commercial applications.

Trevor Lyons↗