Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Neutron Detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Absolute Neutron Rate Measurement and Non-Thermal/Thermonuclear Fusion Differentiation

The goal of fusion energy is to produce significantly more energy from fusion reactions than is input into the device. One of the products of fusion reactions is neutrons, which, due to their lack of charge, provide a unique view into the parameters of the device. Lawrence Livermore National Laboratory (LLNL) in collaboration with the University of California, Berkeley (UCB) have designed, assembled, and fielded a robust and portable neutron detection system known as PANDA (Portable and Adaptable Neutron Diagnostics for ARPA-E). This detector suite consists of three LaBr activation detectors that are calibrated to give a total neutron yield on shot, and twenty-four scintillators coupled to photo-multiplier tubes (SPMT). The SPMTs can be configured to attain spatial, temporal and/or energy information from fusion neutrons. The system was designed to be portable and is compartmentalized so that individual components can be used at different fusion facilities. During the duration of this work, part of the system was installed at the FuZE facility, a part of Zap Energy. Another component was installed that the CESZAR facility at the University of California, San Diego (UCSD) to support experiments by Magneto-Inertial Fusion Technologies, Inc. (MIFTI). The diagnostics were successful at both locations and the LLNL/UCB team supported the data analysis by creating and running analysis scripts and Monte-Carlo calculations. At Zap Energy the diagnostics demonstrated that the fusion from the FuZE device is thermonuclear in nature, a result that resulted in an invited talk at the American Physical Society Division of Plasma Physics and an invited paper. Additionally, temporal and spatial data was taken using the SPMTs to understand the duration and length of fusion production. At UCSD the neutron yield from the diagnostics was used to show improvements to fusion yields on their gas puff Z-pinch when using a gas shell surrounding the fuel. The success in this diagnostic has led to continued work at both Zap Energy and MIFTI, as well as follow on funding and interest at other fusion energy companies.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

An Artificial Neural Network System for Photon-Based Active Interrogation Applications

Active interrogation (AI) is a promising technique to detect shielded special nuclear materials (SNMs). At the University of Michigan, we are developing a photon-based AI system that uses bremsstrahlung radiation from an electron linear accelerator (linac) as an ionizing source and stilbene organic scintillating detectors for neutron detection. Stilbene scintillators are sensitive to fast neutrons and photons and have excellent pulse shape discrimination (PSD) capabilities. The traditional charge integration (CI) method commonly used for PSD analysis eliminates piled-up pulses and relies on a particle discrimination line to separate neutrons and photons. The presence of the intense photon flux during AI creates a significant number of piled-up events in the stilbene scintillator, thereby posing a great challenge to the traditional CI method. Identifying true single neutron pulses becomes challenging due to the presence of a pile-up cloud and overlapping neutron, photon and pile-up clouds in the PSD analysis. To mitigate the effect of pulse pile up and identify true single neutron pulses from stilbene scintillators, an artificial neural network (ANN) system is developed. The developed ANN system identifies single neutron pulses and neutron-photon combinations from piled-up events. The results obtained from a 252Cf measurement in the presence of the intense photon flux show that the developed ANN system outperforms the traditional CI method. Since many piled-up events lie above the particle discrimination line, they get misclassified as neutrons by the traditional CI method resulting in 25% overestimation of the net neutron count rate during the linac pulse. The overall net neutron count rate (single and restored neutrons) during the linac pulse, estimated by the ANN system is 60% of the ground truth. Energy spectroscopy of the ANN attributed single neutron pulses further provides evidence on the detection of prompt fission neutrons from the 252Cf fission source.

42 ENGINEERING↗

Active Neutron Interrogation to Detect Shielded Fissionable Material

Portable electronic neutron generators (ENGs) may be used to interrogate suspicious items to detect, characterize, and quantify the presence fissionable material based upon the measurement of prompt and/or delayed emissions of neutrons and/or photons resulting from fission. The small size (<0.2 m3), light weight (<12 kg), and low power consumption (<50 W) of modern ENGs makes them ideally suited for use in field situations, incorporated into systems carried by 2-3 individuals under rugged conditions. At Idaho National Laboratory we are investigating techniques and portable equipment for performing active neutron interrogation of moderate sized objects less than ~2-4 m3 to detect shielded fissionable material. Our research in this area relies upon the use of pulsed deuterium-tritium ENGs and the measurement of die-away prompt fission neutrons and other neutron signatures in-between neutron pulses from the ENG and after the ENG is turned off.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Detection of thermal neutrons with a CMOS pixel sensor for a future dosemeter

The RaMsEs group (Radioprotection et Mesures Environnementales) is developing a new compact device for operational neutron dosimetry. The electronic part of the detector is made of an integrated active pixel sensor, originally designed for tracking in particle physics. This device has useful features for neutrons, such as high detection efficiency for charged particles, good radiation resistance, high readout speed, low power consumption and high rejection of photon background. A good response of the device to fast neutrons has already been demonstrated [1]. In order to test the sensibility of the detector to thermal neutrons, experiments have been carried out with a 512 x 512 pixel CMOS sensor on a californium source moderated with heavy water (Cf.D{sub 2}O) on the Van Gogh irradiator at the LMDN, IRSN, Cadarache (France)). A thin boron converter is used to benefit from the significant cross section of the {sup 10}B (n,{alpha}) {sup 7}Li reaction. Results show a high detection efficiency (around 10{sup -3}) of the device to thermal neutrons. Our measurements are in good agreement with GEANT4 Monte Carlo simulations. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Detection of Landmines by Neutron Backscattering: Effects of Soil Moisture on the Detection System

Detection of buried land mines by using neutron backscattering technique (NBS) is a well established method. It depends on detecting a hydrogen anomaly in dry soil. Since a landmine and its plastic casing contain much more hydrogen atoms than the dry soil, this anomaly can be detected by observing a rise in the number of neutrons moderated to thermal or epithermal energy. But, the presence of moisture in the soil limits the effectiveness of the measurements. In this work, a landmine detection system using the NBS technique was designed. A series of Monte Carlo calculations was carried out to determine the limits of the system due to the moisture content of the soil. In the simulations, an isotropic fast neutron source ({sup 252}Cf, 100 mug) and a neutron detection system which consists of five {sup 3}He detectors were used in a practicable geometry. In order to see the effects of soil moisture on the efficiency of the detection system, soils with different water contents were tested.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

First near-threshold measurements of the 13 C($α, n$ 1 ) 16 O reaction for low-background-environment characterization

The modeling of background sources in large volume detection systems requires accurate nuclear cross sections for a variety of reactions. Among the most important are (α,n) on light nuclei, where α particles, up to ≈9 MeV, are produced from the decay of actinides present in trace amounts in detection and structural material. In order to model the neutron energy spectra and production of other secondary particles, the partial cross sections are needed. Yet very little experimental data exists for these partial cross sections because past measurements, hampered by the experimental challenges of neutron detection, have focused mostly on total reaction cross section measurements. Here, in this paper, the partial cross section of the 13 C(α,n 1 ) 16 O reaction is reported for the first time. The measurements were made near the reaction threshold using a high energy resolution helium spectrometer. The measurements show a rapidly increasing cross section, which quickly becomes a significant fraction of the total reaction cross section. Measurements are compared with previous theory estimates and differences of more than an order of magnitude are found. A comparison is made with new total cross section measurements and the current level of consistency is demonstrated.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Neutron Scattering Instrumentation Research and Development for High Spatial and Temporal Resolution Imaging at Oak Ridge National Laboratory

Neutron scattering facilities like those available at ORNL are enabling the discovery and development of advanced materials include those to be used for next generation energy storage systems. In spite of all the success that neutron imaging has enjoyed in recent years, even higher-impact research is limited by the current temporal and spatial resolution of neutron detection devices. In particular, the spatial resolution of all neutron imaging methods in use and under development is fundamentally limited by the variance introduced by the charged particles emitted from neutron absorption. Thus, we are investigating, designing and demonstrating an array of ~1 micron-sized glass scintillating fibers arranged via photonics-crystal-fiber patterning techniques-- with particle tracking (a must) so that position resolution can be finer than than that allowed by the charged particle ranges. The processes, knowledge and algorithms developed will allow for spatially (1 micron) and time resolved (<100 ns), high throughput neutron transmission imaging in large areas at reasonable costs.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Feasibility study of Self Powered Neutron Detectors in Fast Reactors for detecting local change in neutron flux distribution

Neutron flux monitoring system forms an integral part of the design of a Generation IV sodium cooled fast reactor system. Diverse possibilities of detector systems installation have to be investigated with respect to practicality and feasibility according to the detection parameters. In this paper, we demonstrate the feasibility of using self powered neutron detectors as in-core detectors in fast reactors for detecting local change in neutron flux distribution. We show that the gamma contribution from fission products decay in the fuel and activation of structural materials is very small compared to the fission gammas. Thus, it is possible for the in-core SPND signal to follow changes in local neutron flux as they are proportional to each other. This implies that the signal from an in-core SPND can provide dynamic information on the neutron flux perturbations occurring inside the reactor core. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

The Prompt Fission Neutron Spectrum of 235 U(n,f) below 2.5 MeV for Incident Neutrons from 0.7 to 20 MeV

New prompt fission neutron spectrum measurements are reported for 235 U(n,f) reactions induced by neutrons with energies from 0.7 to 20 MeV. These measurements cover outgoing neutron energies from 2.5 MeV down to 10 keV, using an array of 6 Li-glass scintillators for neutron detection and a double time-of-flight technique. The neutrons were produced at the Weapons Neutron Research facility of the Los Alamos Neutron Science Center. A detailed MCNP ® model of the experimental equipment and the surrounding room was used to interpret the experimental results. Backgrounds were measured in situ, making use of the time-dependent singles rates of the various detectors with asynchronous readout from waveform digitizers. The results presented here have been included in a re-evaluation of the fission neutron spectra for this fissioning system, a description of which is presented elsewhere in this issue.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Extraction of the neutron electric form factor from measurements of inclusive double spin asymmetries

Background: Measurements of the neutron charge form factor, G$n\atop{E}$, are challenging because the neutron has no net charge. Additionally, measurements of the neutron form factors must use nuclear targets which require accurately accounting for nuclear effects. Extracting G$n\atop{E}$ with different targets and techniques provides an important test of our handling of these effects. Purpose: The goal of the measurement was to use an inclusive asymmetry measurement technique to extract the neutron charge form factor at a four-momentum transfer of 1 (GeV/c) 2 . This technique has very different systematic uncertainties than traditional exclusive measurements and thus serves as an independent check of whether nuclear effects have been taken into account correctly. Method: The inclusive quasielastic reaction 3 $→\atop{He}$ ($→\atop{e}$, e') was measured at Jefferson Laboratory. The neutron electric form factor, G$n\atop{E}$, was extracted at Q 2 = 0.98 ( GeV/c) 2 from ratios of electron-polarization asymmetries measured for two orthogonal target spin orientations. This Q 2 is high enough that the sensitivity to G$n\atop{E}$ is not overwhelmed by the neutron magnetic contribution, and yet low enough that explicit neutron detection is not required to suppress pion production. Results: The neutron electric form factor, G$n\atop{E}$, was determined to be 0.0414 ± 0.0077 ( stat ) ± 0.0022 ( syst ), providing the first high-precision inclusive extraction of the neutron's charge form factor. In conclusion: The use of the inclusive quasielastic 3 $→\atop{He}$ ($→\atop{e}$, e') with a four-momentum transfer near 1 (GeV/c) 2 has been used to provide a unique measurement of G$n\atop{E}$. This new result provides a systematically independent validation of the exclusive extraction technique results and implies that the nuclear corrections are understood. This is contrary to the proton form factor where asymmetry and differential cross section measurements have been shown to have large systematic differences.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Development of ZnO Nanorod-Based Scintillators Grown Under a Low-Temperature Hydrothermal Method for Use in Alpha-Particle and Thermal Neutron Detectors

Due to material properties such as sub-nanosecond decay time and high light output, ZnO-based scintillators are being developed as a radiation detector material. In this study, ZnO nanorods grown via a low temperature hydrothermal method were investigated using photoluminescence (PL) and α-particle testing. Vertically aligned ZnO nanorods of varying lengths were grown and tested. The ZnO nanorod scintillators were compared to a MOCVD grown ZnO scintillator. In conclusion, the low temperature hydrothermal method shows promising performance for low-cost growth of ZnO scintillators for use as α-particle detectors and as a part of thermal neutron detection systems if doped with or in contact with a thermal neutron radiator.

36 MATERIALS SCIENCE↗

Reassessment of PHDS Fulcrum40h High Purity Germanium (HPGe) Detector System Performance

This report presents a comprehensive evaluation of the updated PHDS Fulcrum40h High Purity Germanium (HPGe) detector system, benchmarking its performance, usability, and software capabilities against the current National Nuclear Security Administration (NNSA) Nuclear Emergency Support Team (NEST) HPGe Detector System Requirements Document. Systematic measurements were conducted using a single Fulcrum40h detector to assess key parameters including gamma efficiency and resolution, neutron detection efficiency, gamma pulse-pileup response, and gamma-to-neutron crosstalk. The Fulcrum40h system, acquired in August 2022, has undergone recent updates by PHDS to address deficiencies identified following the initial NEST requirements release. The results provide critical insights into the detector’s operational capabilities and compliance with NNSA NEST standards.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fissile material holdup measurement systems: an historical review of hardware and software

The measurement of fissile material holdup is accomplished by passively measuring the energy-dependent photon flux and/or passive neutron flux emitted from the fissile material deposited within an engineered process system. Both measurement modalities--photon and neutron--require the implementation of portable, battery-operated systems that are transported, by hand, from one measurement location to another. Because of this portability requirement, gamma-ray spectrometers are typically limited to inorganic scintillators, coupled to photomultiplier tubes, a small multi-channel analyzer, and a handheld computer for data logging. For neutron detection, polyethylene-moderated, cadmium-back-shielded He-3 thermal neutron detectors are used, coupled to nuclear electronics for supplying high voltage to the detector, and amplifying the signal chain to the scaler for counting. Holdup measurement methods, including the concept of Generalized Geometry Holdup (GGH), are well presented by T. Douglas Reilly in LA-UR-07-5149 and P. Russo in LA-14206, yet both publications leave much of the evolutionary hardware and software to the imagination of the reader. This paper presents an historical review of systems that have been developed and implemented since the mid-1980s for the nondestructive assay of fissile material, in situ. Specifications for the next-generation holdup measurements systems are conjectured.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance of borated scintillator screens for high-resolution neutron imaging

The most commonly used screens for neutron imaging consist of 6 LiF + ZnS. This type of screen yields the highest light output per detected neutron. For high resolution, gadolinium oxysulfide (GOS, Gadox) screens are employed, which have a much higher detection efficiency, but a light output so much lower than LiF + ZnS that measurements are often limited by photon statistics. Historically, screens using boron as a neutron-sensitive material have not been very successful. However, a new preparation method was introduced recently that produces light output higher than Gadox with detection efficiency greater than LiF + ZnS. Measurements of these new borated screens were performed at the NeXT facility at ILL, Grenoble, in comparison to a high resolution Gadox screen.

10B↗

Detection of 14 MeV neutrons in high temperature environment up to 500 deg. C using 4H-SiC based diode detector

In reactor technology and industrial applications detection of fast and thermal neutrons plays a crucial role in getting relevant information about the reactor environment and neutron yield. The inevitable elevated temperatures make neutron yield measurements problematic. Out of the currently available semiconductors 4H-SiC seems to be the most suitable neutron detector material under extreme conditions due to its high heat and radiation resistance, large band-gap and lower cost of production than in case of competing diamond detectors. In the framework of the European I-Smart project, optimal {sup 4}H-SiC diode geometries were developed for high temperature neutron detection and have been tested with 14 MeV fast neutrons supplied by a deuterium-tritium neutron generator with an average neutron flux of 10{sup 10}-10{sup 11} n/(s*cm{sup 2}) at Neutron Laboratory of the Technical University of Dresden in Germany from room temperatures up to several hundred degrees Celsius. Based on the results of the diode measurements, detector geometries appear to play a crucial role for high temperature measurements up to 500 deg. C. Experimental set-ups using SiC detectors were constructed to simulate operation in the harsh environmental conditions found in the tritium breeding blanket of the ITER fusion reactor, which is planned to be the location of neutron flux characterization measurements in the near future. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

New Cerium-Based Metal-Organic Scintillators for Radiation Detection

We have previously shown that a new class of scintillating materials can be developed based on the synthesis and crystal growth of rare-earth metal-organic compounds. The first scintillator of this type consisted of single crystals of CeCl3(CH3OH)4 that were grown from a methanol solution. These crystals were shown to be applicable to both gamma-ray and fast neutron detection. Subsequently, metal-organic scintillators consisting of the compound LaBr3(CH3OH)4 activated with varying levels of Ce3+ and of CeBr3(CH3OH)4 were grown in single crystal form. We have now extended the development of this new class of scintillators to more complex organic components by reacting rare-earth halides such as CeCl3 or CeBr3 with different isomers of propanol and butanol including 1-propanol, isobutanol, n-butanol, and tert-butanol. The reaction of CeCl3 or CeBr3 with these organics results in the formation of new and relatively complex molecular crystals whose structures were determined using single-crystal X-ray diffraction. These new metal-organic scintillating materials were grown in single crystal form from solution, and their scintillation characteristics have been investigated using X-ray-excited luminescence plus energy spectra obtained with gamma-ray and alpha-particle sources. If the reactions between the inorganic and organic components are not carried out under very dry and highly controlled conditions, molecular structures can be formed that incorporate waters of hydration. The present observation of scintillation in these hydrated rare-earth metal-organic compounds is apparently an original finding, since we are not aware of any previous reports of scintillation being observed in a material that incorporates waters of hydration

Metal organics↗

Accelerating fissile material detection with a neutron source

A neutron detector system for discriminating fissile material from non-fissile material wherein a digital data acquisition unit collects data at high rate, and in real-time processes large volumes of data directly to count neutrons from the unknown source and detecting excess grouped neutrons to identify fission in the unknown source. The system includes a Poisson neutron generator for in-beam interrogation of a possible fissile neutron source and a DC power supply that exhibits electrical ripple on the order of less than one part per million. Certain voltage multiplier circuits, such as Cockroft-Walton voltage multipliers, are used to enhance the effective of series resistor-inductor circuits components to reduce the ripple associated with traditional AC rectified, high voltage DC power supplies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗