Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Neutrino detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

The design, construction, and commissioning of the KATRIN experiment

The KArlsruhe TRItium Neutrino (KATRIN) experiment, which aims to make a direct and model-independent determination of the absolute neutrino mass scale, is a complex experiment with many components. More than 15 years ago, we published a technical design report (TDR) to describe the hardware design and requirements to achieve our sensitivity goal of 0.2 eV at 90%C.L. on the neutrino mass. Since then there has been considerable progress, culminating in the publication of first neutrino mass results with the entire beamline operating. In this paper, we document the current state of all completed beamline components (as of the first neutrino mass measurement campaign), demonstrate our ability to reliably and stably control them over long times,and present details on their respective commissioning campaigns.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Implementation and optimization of the PTOLEMY transverse drift electromagnetic filter

The PTOLEMY transverse drift filter is a new concept to enable precision analysis of the energy spectrum of electrons near the tritium β-decay endpoint. Here, we detail the implementation and optimization methods for successful operation of the filter for electrons with a known pitch angle. We present the first demonstrator that produces the required magnetic field properties with an iron return-flux magnet. Two methods for the setting of filter electrode voltages are detailed. The challenges of low-energy electron transport in cases of low field are discussed, such as the growth of the cyclotron radius with decreasing magnetic field, which puts a ceiling on filter performance relative to fixed filter dimensions. Additionally, low pitch angle trajectories are dominated by motion parallel to the magnetic field lines and introduce non-adiabatic conditions and curvature drift. To minimize these effects and maximize electron acceptance into the filter, we present a three-potential-well design to simultaneously drain the parallel and transverse kinetic energies throughout the length of the filter. These optimizations are shown, in simulation, to achieve low-energy electron transport from a 1 T iron core (or 3 T superconducting) starting field with initial kinetic energy of 18.6 keV drained to < 10 eV (< 1 eV) in about 80 cm. This result for low field operation paves the way for the first demonstrator of the PTOLEMY spectrometer for measurement of electrons near the tritium endpoint to be constructed at the Gran Sasso National Laboratory (LNGS) in Italy.

47 OTHER INSTRUMENTATION↗

Wideband precision stabilization of the -18.6kV retarding voltage for the KATRIN spectrometer

The Karlsruhe Tritium Neutrino Experiment (KATRIN) measures the effective electron anti-neutrino mass with an unprecedented design sensitivity of 0.2 eV (90 % C.L.). In this experiment, the energy spectrum of beta electrons near the tritium decay endpoint is analyzed with a highly accurate spectrometer. To reach the KATRIN sensitivity target, the retarding voltage of this spectrometer must be stable to the ppm (1 × 10 -6 ) level and well known on various time scales (μs up to months), for values around -18.6 kV. A custom-designed high-voltage regulation system mitigates the impact of interference sources in the absence of a closed electric shield around the large spectrometer vessel. In this article, we describe the regulation system and its integration into the KATRIN setup. Independent monitoring methods demonstrate a stability within 2 ppm, exceeding KATRIN's specifications.

47 OTHER INSTRUMENTATION↗

Waveform resampling with LMN method

In this article, resampling is a common technique applied in digital signal processing. Based on the Fast Fourier Transformation (FFT), we apply an optimization called here the LMN method to achieve fast and robust re-sampling. In addition to performance comparisons with some other popular methods, we illustrate the effectiveness of this LMN method in a particle physics experiment: re-sampling of waveforms from Liquid Argon Time Projection Chambers.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Fiber-coupled digital photo sensors for large Time Projection Chambers

Here, this paper presents a novel approach to addressing challenges in neutrino event reconstruction within large Time Projection Chambers (TPCs). By integrating fiber-coupled digital silicon photomultipliers, we propose a design that enhances light detection and improves both energy resolution and event reconstruction. Advancements in power and signal over fiber technologies are leveraged to deploy digital sensors within the TPC bulk volume, enabling precise timing and robust particle identification.

47 OTHER INSTRUMENTATION↗

Measurement of the mean excitation energy of liquid argon

The mean excitation energy (I-value) of liquid argon is a critical input for energy estimation in neutrino oscillation experiments. It is measured to be 199 +4 -5 eV using the range of 402.2 MeV protons from the Fermilab Linac. This compares to the author's recent evaluation of (197 ± 7) eV based on a combination of an oscillator strength distribution analysis, gaseous argon range measurements, sparse stopping power data on solid argon, and an extrapolation of data on the effect of phase from other substances. Using all sources of information, we recommend a value of (198 ± 4) eV for liquid argon, which is significantly higher than 188 eV, from ICRU-37's gaseous argon evaluation, commonly used in Monte Carlo codes such as Geant4.

47 OTHER INSTRUMENTATION↗

Project 8 apparatus for cyclotron radiation emission spectroscopy with 83m Kr and tritium

Cyclotron Radiation Emission Spectroscopy (CRES) is a novel technique for the precise measurement of relativistic electron energy. This technique is being employed by the Project 8 collaboration for measuring a high-precision tritium beta decay spectrum to perform a frequency-based measurement of the neutrino mass. In this work, we describe the Project 8 Phase II apparatus, used for the detection of the CRES signal from the conversion electrons of 83m Kr and the first CRES measurement of the beta-decay spectrum of molecular tritium.

Neutrino detectors↗

Thermodynamic stability of xenon-doped liquid argon detectors

Liquid argon detectors are employed in a wide variety of nuclear and particle physics experiments. The addition of small quantities of xenon to argon modifies its scintillation, ionization, and electroluminescence properties and can improve its performance as a detection medium. However, a liquid argon-xenon mixture can develop instabilities, especially in systems that require phase transitions or that utilize high xenon concentrations. In this work, we analyze the causes of these instabilities and describe a small (liter-scale) apparatus with a unique cryogenic circuit specifically designed to handle argon-xenon mixtures. The system is capable of condensing argon gas mixed with $\mathscr{O}$ (1%) xenon by volume and maintains a stable liquid mixture near the xenon saturation limit while actively circulating it in the gas phase. We also demonstrate control over instabilities that develop when the detector condition is allowed to deviate from optimized settings. This progress enables future liquid argon detectors to benefit from the effects of high concentrations of xenon doping, such as more efficient detection of low-energy ionization signals. In conclusion, this work also develops tools to study and mitigate instabilities in large argon detectors that use low concentration xenon doping.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Combined search for neutrinos from dark matter self-annihilation in the Galactic Center with ANTARES and IceCube

In this work, we present the results of the first combined dark matter search targeting the Galactic Centre using the ANTARES and IceCube neutrino telescopes. For dark matter particles with masses from 50 to 1000 GeV, the sensitivities on the self-annihilation cross section set by ANTARES and IceCube are comparable, making this mass range particularly interesting for a joint analysis. Dark matter self-annihilation through the $\tau^+\tau^-$, $\mu^+\mu^-$, $b\bar{b}$ and $W^+W^-$ channels is considered for both the Navarro-Frenk-White and Burkert halo profiles. In the combination of 2,101.6 days of ANTARES data and 1,007 days of IceCube data, no excess over the expected background is observed. Limits on the thermally-averaged dark matter annihilation cross section $\langle\sigma_A\upsilon\rangle$ are set. These limits present an improvement of up to a factor of two in the studied dark matter mass range with respect to the individual limits published by both collaborations. When considering dark matter particles with a mass of 200 GeV annihilating through the $\tau^+\tau^-$ channel, the value obtained for the limit is $7.44 \times 10^{-24} \text{cm}^{3}\text{s}^{-1}$ for the Navarro-Frenk-White halo profile. For the purpose of this joint analysis, the model parameters and the likelihood are unified, providing a benchmark for forthcoming dark matter searches performed by neutrino telescopes.

79 ASTRONOMY AND ASTROPHYSICS↗

Measurement of the π - -Ar total hadronic cross section at the LArIAT experiment

We present the first measurement of the negative pion total hadronic cross section on argon in a restricted phase space, which we performed at the Liquid Argon In A Testbeam (LArIAT) experiment. All hadronic reaction channels, as well as hadronic elastic interactions with scattering angle greater than 5° are included. The pions have kinetic energies in the range 100–700 MeV and are produced by a beam of charged particles impinging on a solid target at the Fermilab test beam facility. LArIAT employs a 0.24 ton active mass liquid argon time projection chamber (LArTPC) to measure the pion hadronic interactions. For this measurement, LArIAT has developed the “thin slice method,” a new technique to measure cross sections with LArTPCs. While moderately higher, our measurement of the π - -Ar total hadronic cross section is generally in agreement with the geant4 prediction.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗