Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Nanoscale Resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Application of a deep learning semantic segmentation model to helium bubbles and voids in nuclear materials

Imaging nanoscale radiation-induced defects using the transmission electron microscope (TEM) is a key factor in the successful implementation of materials for nuclear energy structural applications. Analyzing each defect in a TEM micrograph is currently a manual task. To identify the defects in a single image can take anywhere from 15 min to an hour and a project can require the analysis of anywhere from tens to ≥ 100 images. Here, we use artificial intelligence (AI) models to automate this task. For simplification, we evaluated images with only a single type of defect; helium bubbles. Additionally, we performed semantic segmentation of these helium bubble defects in electron microscopy images of irradiated FeCrAl alloys using a deep learning DefectSegNet model. This model, which was previously used to classify crystal defects, is inspired by the classic DenseNet and U-Net image segmentation models. It claims high spatial resolution, but has poor performance at object boundaries. Our paper improves the DefectSegNet model’s application by adding two new features. First, the DefectSegNet model is applied not only to perform calculation pixel-wise but also object (or feature) wise. Because object-wise metrics are directly relevant to our final goal of detecting bubbles, whereas pixel-wise classification is only an intermediate step, it is an important part of our study. Second, a distance map loss (DML) function has been added to increase its performance at object boundaries. It is crucial to accurately represent defects boundaries, especially bubbles, in order to track the bubble-induced swelling caused by irradiation. The boundary-focused DML function is also compared to other loss functions like Cross-entropy, Weighted Binary Cross Entropy (WBCE), Dice and Intersection over Union (IOU). Finally, by incorporating new features, we found a marked improvement on segmentation quality and better shape preservation at the boundaries and areas of the bubbles.

42 ENGINEERING↗

Microwave Microscopy and Its Applications

Understanding the nanoscale electrodynamic properties of a material at microwave frequencies is of great interest for materials science, condensed matter physics, device engineering, and biology. With specialized probes, sensitive detection electronics, and improved scanning platforms, microwave microscopy has become an important tool for cutting-edge materials research in the past decade. In this article, we review the basic components and data interpretation of microwave imaging and its broad range of applications. In addition to the general-purpose mapping of permittivity and conductivity, microwave microscopy is now exploited to perform quantitative measurements on semiconductor devices, photosensitive materials, ferroelectric domains and domain walls, and acoustic-wave systems. Implementation of the technique in low-temperature and high-magnetic-field chambers has also led to major discoveries in quantum materials with strong correlation and topological order. We conclude the review with an outlook of the ultimate resolution, operation frequency, and future industrial and academic applications of near-field microwave microscopy.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Thermoreflectance Detection of Point Defects Resulting from Focused Ion Beam Milling

Focused ion beam (FIB) milling is a commonly used tool for nanoscale material processing, such as for transmission electron microscopy (TEM) sample preparation, or the creation of fiducial markers prior to other processes and measurements. During milling, a high energy ion beam is used to remove material via sputtering. The expelled target material may return to the sample surface however, affecting subsequent measurements. Beam spreading or irradiation due to neutral gallium may also irradiate a larger area than intended. Extensive research has explored the effects of FIB milling on the prepared TEM sample, but few have looked at the effects of milling on the properties of the sample surrounding the milled region. We use multiple pump-probe laser-based techniques (time domain thermoreflectance and steady-state thermoreflectance) to measure the spatial extent of FIB-induced surface/subsurface changes on a series of silicon wafers milled at multiple currents and doses. We supplement these measurements with high-resolution scanning transmission electron microscopy, energy dispersive X-ray spectroscopy, stylus profilometry, and time-of-flight secondary ion mass spectroscopy. We find a sample surface affected by the FIB up to 1 mm from where milling occurred, with a notable dependence on the ion beam current. We also note remarkably high sensitivity to surface defects using the thermoreflectance metrologies, including detection where other measurements failed.

defects↗

Nanoscale properties of lead halide perovskites by scanning tunneling microscopy

Since the introduction of lead halide perovskites, tremendous progress has been made regarding their stability, reproducibility and durability. However, one of the issues that remains is related to the interfacial atomic structure arrangement and structure-property relationship under optical and electrical stimuli. In this critical review, we highlight the recent progress using scanning tunneling microscopy (STM) to understand the nanoscale properties and dynamic processes occurring in these halide perovskite materials. STM is known to be a very challenging technique, which is reflected by the low number of relevant publications in the last years. These initial reports mirror the unique potential of STM to give Ångstrom-scale insight into the (opto)-electronic properties, morphology and underlying electronic structure and provide a path toward harnessing the full potential of these materials. However, care must be taken to understand the effects of the perturbations caused by STM and tailor the measurement conditions accordingly.

36 MATERIALS SCIENCE↗

Kelvin probe force microscopy under ambient conditions

Kelvin probe force microscopy (KPFM) is a technique derived from atomic force microscopy that provides maps of surface potential or work function differences across material systems, with nanometre-scale resolution. KPFM is a useful tool for investigating electrical phenomena such as dipole orientation, interfacial charge transfer, charge accumulation, band bending and doping levels. This Primer aims to provide an overview of typical ambient-condition KPFM measurements, covering their underlying principles, experimental implementations and wide-ranging applications. Key KPFM variants, including amplitude and frequency modulation, heterodyne detection schemes and innovative open loop and pulsed force techniques, are discussed, with practical guidance on optimizing signal acquisition and reducing errors. Specialized approaches, such as time-resolved KPFM and multimodal KPFM, are discussed for their ability to capture dynamic charge processes and chemical information, respectively. Here, we highlight recent advances in KPFM applications, spanning metal alloys, soft matter, ferroelectrics, photovoltaics and 2D materials, showcasing its versatility across research domains. By addressing current limitations and identifying future opportunities, this Primer underscores the transformative potential of KPFM in advancing the understanding of nanoscale electrical phenomena.

Zahmatkeshsaredorahi, Amirhossein [Lehigh Univ., B↗

Direct measurement of thermal Knudsen forces in rarefied gas environments

At micro- and nanoscales, momentum transfer between surfaces is influenced by various physical mechanisms, including quantum fluctuations, electromagnetic interactions, electric charges, and the dynamics of (rarefied) gases. Under non-isothermal conditions, rarefied gases give rise to thermal Knudsen forces whose magnitudes strongly depend on the gas species and surface characteristics. Knudsen forces are particularly relevant in nanotechnology, optical manipulation, and aerospace systems, where gas rarefaction occurs due to highly confined geometries, sub-micrometer length scales, and reduced particle densities. Despite their significance, predictive modeling of Knudsen forces is limited by a lack of comprehensive experimental data across diverse materials and surface morphologies. Here, in this work, we present a highly sensitive and adaptable measurement platform capable of directly quantifying Knudsen forces using a suspended, interchangeable micro-cantilever within controlled rarefied helium and nitrogen environments. The system integrates optical fiber interferometry to precisely capture out-of-plane displacements at sub-micrometer resolution, driven by Knudsen forces. From the empirical data, we derive a robust correlation linking the magnitudes of Knudsen forces to energy accommodation coefficients, offering deeper insights into the underlying gas–surface interaction mechanisms.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Infrared surface phonon nanospectroscopy of an interacting dielectric-particle–dielectric-substrate dimer using fast electrons

Refinements in energy monochromation and aberration correction in state-of-the-art scanning transmission electron microscopes has opened access to the far infrared regime for spectroscopic characterization at the nanoscale. At these low energies, the dielectric environment, such as a dielectric slab adjacent to the target specimen, may no longer play a passive role in the spectrum. Instead, the environment may itself host resonances that mix with those of the target and complicate interpretation of its spectral responses. This article explores a theoretical description of the coupling between the collective vibrational surface modes of a dielectric particle and dielectric slab of varying thickness for the purpose of elucidating the interacting phononic excitations in dielectric materials typical of inelastic electron scattering measurements in the infrared. Dynamical coordinates and a governing Hamiltonian are rigorously defined in the quasistatic limit to account for phonon mode mixing and forcing by an aloof electron probe, which travels along a grazing trajectory, parallel to the dielectric slab. As the spectral window of interrogation by fast electron probes has been extended down to thermal energies with unprecedented meV energy resolution, theoretical models like that presented herein are crucial for accurate interpretation of experimental data.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Site-specific plan-view (S)TEM sample preparation from thin films using a dual-beam FIB-SEM

To fully evaluate the atomic structure, and associated properties of materials using transmission electron microscopy, examination of samples from three non-collinear orientations is needed. This is particularly challenging for thin films and nanoscale devices built on substrates due to limitations with plan-view sample preparation. In this work, a new method for preparation of high-quality, site-specific, plan-view TEM samples from thin-films grown on substrates, is presented and discussed. Here, it is based on using a dual-beam focused ion beam scanning electron microscope (FIB-SEM) system. To demonstrate the method, the samples were prepared from thin films of perovskite oxide BaSnO 3 grown on a SrTiO 3 substrate and metal oxide IrO 2 on a TiO 2 substrate, ranging from 20–80 nm in thicknesses using molecular beam epitaxy. While the method is optimized for the thin films, it can be extended to other site-specific plan-view samples and devices build on wafers. Aberration-corrected STEM was used to evaluate the quality of the samples and their applicability for atomic-resolution imaging and analysis.

BaSnO3↗

Modeling ablator grain structure impacts in ICF implosions

High-density carbon is a leading ablator material for inertial confinement fusion (ICF). This and some other ablator materials have grain structure which is believed to introduce very small-scale (~nm) density inhomogeneity. In principle, such inhomogeneity can affect key ICF metrics like fuel compression and yield, by, for example, acting as a seed for instabilities and inducing mix between ablator and fuel. However, assessments of such effects are uncertain due to the difficulty of modeling this small-scale structure in ICF simulations, typically requiring reduced-resolution modeling that scales these features. We present a grain model and show both the impact of de-resolving grains and the complex mixing dynamics such structures can induce. We find that different methods for de-resolving grains can yield both different total deposition of kinetic energy perturbations and different fuel–ablator mixing. We then show a simple-to-implement approach for approximately conserving the deposition of perturbed kinetic energy and demonstrate that, for the present grain model and test cases, this approach yields a reasonably matched time history of mix width between less and more resolved grain models. The simulations here also demonstrate the complex interaction history between grain-induced mixing and instability around the fuel–ablator interface, showing, for example, that the grain-induced perturbations typically trigger instability of conduction-driven density gradients in the DT fuel, enhancing mix penetration early in the acceleration of the shell. Furthermore simulating both microscale and nanoscale grains, we find initial evidence for larger mixing in the microscale case of the present model, despite smaller deposited kinetic energy perturbation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Nonequilibrium Thermodynamics of Colloidal Gold Nanocrystals Monitored by Ultrafast Electron Diffraction and Optical Scattering Microscopy

Metal nanocrystals exhibit important optoelectronic and photocatalytic functionalities in response to light. These dynamic energy conversion processes have been commonly studied by transient optical probes to date, but an understanding of the atomistic response following photoexcitation has remained elusive. In this paper, we use femtosecond resolution electron diffraction to investigate transient lattice responses in optically excited colloidal gold nanocrystals, revealing the effects of nanocrystal size and surface ligands on the electron–phonon coupling and thermal relaxation dynamics. First, we uncover a strong size effect on the electron–phonon coupling, which arises from reduced dielectric screening at the nanocrystal surfaces and prevails independent of the optical excitation mechanism (i.e., inter- and intraband). Second, we find that surface ligands act as a tuning parameter for hot carrier cooling. Particularly, gold nanocrystals with thiol-based ligands show significantly slower carrier cooling as compared to amine-based ligands under intraband optical excitation due to electronic coupling at the nanocrystal/ligand interfaces. Finally, we spatiotemporally resolve thermal transport and heat dissipation in photoexcited nanocrystal films by combining electron diffraction with stroboscopic elastic scattering microscopy. Taken together, we resolve the distinct thermal relaxation time scales ranging from 1 ps to 100 ns associated with the multiple interfaces through which heat flows at the nanoscale. Our findings provide insights into optimization of gold nanocrystals and their thin films for photocatalysis and thermoelectric applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Statistical White-Line Analysis in High-Throughput TXM-XANES for Chemical State Quantification

The transmission X-ray microscopy (TXM) based X-ray absorption near-edge structure (XANES) technique provides three-dimensional mapping of element-specific chemical states at nanometer-scale spatial resolution and micrometer-scale fields of view. However, compared to conventional volume-averaged XANES (VA-XANES) measurements, the inherently small voxel size in TXM-XANES leads to a lower signal-to-noise ratio, making full-spectrum analysis computationally demanding and less robust. Here, we present the structural and compositional conditions for a statistical white-line analysis framework under which chemical state information can be directly extracted from the white-line peak position in voxel spectra without the need for voxel-wise background subtraction or normalization, under well-defined structural and compositional conditions. The method is validated on layered oxide cathode materials, where low-order polynomial fitting accurately reproduces white-line features, and the extracted energy distributions correlate strongly with VA-XANES results. This statistical approach enables high-throughput, dose-efficient, and noise-robust chemical state quantification in TXM-XANES, offering broad applicability to functional materials requiring nanoscale oxidation-state mapping.

TXM↗

Nanophotonic waveguide chip-to-world beam scanning

A seamless chip-to-world photonic interface enables broad advancements in optical ranging, display, communication, computation and quantum information science. The ideal solution enables two-dimensional scanning of a diffraction-limited beam from anywhere on a photonic integrated circuit to a large number of resolvable spots. Current beam-scanning technologies are limited by a fundamental trade-off: photonic-integrated-circuits with diffractive optics offer scalability but have poor mode quality, whereas inertially limited micromechanical scanners provide high-quality beams but lack scalable integration. Here we report a photonic ski-jump—a nanoscale waveguide monolithically integrated on a piezoelectric cantilever—to overcome these limitations. It passively curls ~90° out-of-plane within a less-than-0.1 mm 2 footprint, emits a submicrometre, broadband diffraction-limited beam, and exhibits kilohertz-rate mechanical resonances with quality factors of over 10,000. Fabricated in a volume complementary metal–oxide–semiconductor (CMOS) foundry, our device enables scalable two-dimensional beam scanning. Driven on-resonance at CMOS-level voltages, it achieves a footprint-adjusted spot rate of 68.6 mega spots s –1 mm–², exceeding state-of-the-art micro-electro-mechanical systems mirrors by more than 50-fold, which is sufficient for one million pixels at 100 Hz from an approximately 1.5 mm diameter footprint. We demonstrate full-colour image and video projection, and single-photon initialization and readout from silicon vacancy centres in diamond. Finally, by demonstrating uniformity across a 64 ski-jump array, we establish a pathway to achieving greater than one gigaspot resolution at kilohertz rates within a sub-5-cm-diameter footprint, creating a seamless optical pipeline between integrated photonic processors and the free-space world.

Displays↗

Time-Resolved Structural Measurement of Thermal Resistance across a Buried Semiconductor Heterostructure Interface

The precise control and understanding of heat flow in heterostructures is pivotal for advancements in thermoelectric energy conversion, thermal barrier coatings, and efficient heat management in electronic and optoelectronic devices. In this study, we employ high-angular-resolution time-resolved X-ray diffraction to structurally measure thermal resistance in a laser-excited AlGaAs/GaAs semiconductor heterostructure. Our methodology offers femtometer-scale spatial sensitivity and nanosecond time resolution, enabling us to directly observe heat transport across a buried interface. We corroborate established Thermal Boundary Resistance (TBR) values for AlGaAs/GaAs heterostructures and demonstrate that TBR arises from material property discrepancies on either side of a nearly flawless atomic interface. This work not only sheds light on the fundamental mechanisms governing heat flow across buried interfaces but also presents a robust experimental framework that can be extended to other heterostructure systems, paving the way for optimized thermal management in next-generation devices.

36 MATERIALS SCIENCE↗

Spatially and Spectrally Resolved Defects in Polycrystalline CdTe Thin Films Revealed by Quantitative Cathodoluminescence

Increasing the grain size is a potential strategy to reduce grain-boundary recombination and improve performance of thin-film solar cells. Here, CdTe thin films with a range of grain sized were produced by varying the CdC1 2 post-deposition treatment temperature. We use high-resolution cathodoluminescence (CL) microscopy to study recombination and shallow defect levels in detail. Intensities from room temperature CL maps were compared across samples. We find that the CL intensity initially increases with grain size, as expected, but then plateaus as the grain size is increased further. The plateau is correlated with a decrease in the characteristic length-related to the carrier diffusion length-determined from CL intensity profiles near grain boundaries. In addition, low-temperature CL measurements demonstrate the evolution of the defect levels with CdC1 2 temperature.

cadmium telluride thin films↗

Coherent anti-Stokes Raman scattering with squeezed light: CARS for quantum-enhanced spectroscopy and imaging

We theoretically investigate quantum-enhanced coherent anti-Stokes Raman scattering (CARS) using squeezed light to amplify vibrational transition rates at low photon flux. Quantum sensing approaches are needed for nondestructive nanometrology such as in bioimaging where reduced photodamage is desired while retaining resolution and sensitivity. We analyze both single-mode squeezing applied to the pump field and two-mode squeezing between the pump and Stokes fields. We also show that the ordering of displacement and squeezing operations—whether displacement precedes squeezing or squeezing precedes displacement—has an impact on the resulting CARS transition amplitudes due to a difference in the photon number and the quantum-enhancement coefficients, with the latter offering a stronger enhancement in the case of two modes squeezing of the pump and Stokes under experimentally accessible conditions. Furthermore, our calculations capture these quantum enhancements through the intrinsic photon-number correlations of squeezed light, eliminating the need for interferometric detection or higher pump powers that are otherwise required to reach comparable sensitivities in classical CARS. Finally, we outline a quantum plasmonic extension of our model in which local field enhancements caused by surface plasmon excitation in metallic nanoparticles can be incorporated via mode-selective field amplification factors, offering a pathway toward combining squeezed-light quantum optics with surface-enhanced nanoscale spectroscopy and imaging.

Atomic & molecular structure↗

Microscopic theory, analysis, and interpretation of conductance histograms in molecular junctions

Molecular electronics break-junction experiments are widely used to investigate fundamental physics and chemistry at the nanoscale. Reproducibility in these experiments relies on measuring conductance on thousands of freshly formed molecular junctions, yielding a broad histogram of conductance events. Experiments typically focus on the most probable conductance, while the information content of the conductance histogram has remained unclear. Here we develop a microscopic theory for the conductance histogram by merging the theory of force-spectroscopy with molecular conductance. The procedure yields analytical equations that accurately fit the conductance histogram of a wide range of molecular junctions and augments the information content that can be extracted from them. Our formulation captures contributions to the conductance dispersion due to conductance changes during the mechanical elongation inherent to the experiments. In turn, the histogram shape is determined by the non-equilibrium stochastic features of junction rupture and formation. The microscopic parameters in the theory capture the junction’s electromechanical properties and can be isolated from separate conductance and rupture force (or junction-lifetime) measurements. The predicted behavior can be used to test the range of validity of the theory, understand the conductance histograms, design molecular junction experiments with enhanced resolution and molecular devices with more reproducible conductance properties.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ion irradiation induced phase transformation in gold nanocrystalline films

Gold is a noble metal typically stable as a solid in a face-centered cubic (FCC) structure under ambient conditions; however, under particular circumstances aberrant allotropes have been synthesized. In this work, we document the phase transformation of 25 nm thick nanocrystalline (NC) free-standing gold thin-film via in situ ion irradiation studied using atomic-resolution transmission electron microscopy (TEM). Utilizing precession electron diffraction (PED) techniques, crystallographic orientation and the radiation-induced relative strains were measured and furthermore used to determine that a combination of surface and radiation-induced strains lead to an FCC to hexagonal close packed (HCP) crystallographic phase transformation upon a 10 dpa radiation dose of Au 4+ ions. Contrary to previous studies, HCP phase in nanostructures of gold was stabilized and did not transform back to FCC due to a combination of size effects and defects imparted by damage cascades.

36 MATERIALS SCIENCE↗

Quantitative and qualitative bone imaging: A review of synchrotron radiation microtomography analysis in bone research

All levels of the unique hierarchical structure of bone, consisting of collagen and hydroxyapatite crystals at the nanoscale to osteon/lamellae structures at the microscale, contribute to its characteristic toughness and material properties. Elements of bone's density and size contribute to bone quantity (or bone mass), whereas elements of bone's material composition, material properties, internal structure, and organization describe bone quality. Furthermore, bone quantity and quality can be degraded by factors such as aging, disease, treatments, and irradiation, compromising its ability to resist fracture and sustain loading. Accessing the morphology and architecture of bone at the microscale to quantify microstructural features and assess the degree of mineralization and path of crack propagation in bone provides crucial information on how these factors are influencing bone quantity and quality. Synchrotron radiation micro-computed tomography (SRμCT) was first used to assess bone structure at the end of the 1990's. One of the main advantages of the technique is that it enables accurate three-dimensional (3D), non-destructive quantification of structure while traditional histomorphometry on histological sections is inherantly destructive to the sample and two-dimensional (2D). Additionally, SRμCT uses monochromatic, high-flux X-ray beams to provide high-resolution and high-contrast imaging of bone samples. This allows the quantification of small microstructural features (e.g. osteocyte lacunae, canals, trabeculae, microcracks) and direct gray value compositional mapping (e.g. mineral quantification, cement lines) with greater speed and fidelity than lab-based micro-computed tomography. In this article, we review how SRμCT has been applied to bone research to elucidate the mechanisms by which bone aging, disease, and other factors affect bone fragility and resistance to fracture.

60 APPLIED LIFE SCIENCES↗