Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “NOISE INTENSITY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Wave/particle interactions in the plasma sheet

The most frequent and intense waves observed in the geomagnetic tail region are short wavelength electrostatic broadband emissions. Early observations of these waves were made by using IMP 7 and 8 respectively. A broad frequency range for the waves was found, from about 10Hz to several kHz, with an average r.m.s. electric field amplitude of about 1mV/m was found. Other less frequent and less intense wave modes were also identified: magnetic noise bursts and electrostatic electron-cyclotron waves. The highest frequency of occurrence of the electrostatic noise as found in the region near the plasma sheet boundary when anisotropic fluxes of ions streaming either earthward or antiearthward were present. It was confirmed, by using ISEE data that the waves were usually observed during times of ion streaming and that the intensity and frequency range was maximum in the plasma sheet boundary layer and fell off dramatically in the tail lobe and central plasma sheet regions. It is suggested that increases in the electron and ion temperature in going from the tail lobe to the central plasma sheet are a result of scattering of resonant, boundary layer plasma.

Dusenberry, P. R.↗

Performance of a continuously rotating half-wave plate on the POLARBEAR telescope

A continuously rotating half-wave plate (CRHWP) is a promising tool to improve the sensitivity to large angular scales in cosmic microwave background (CMB) polarization measurements. With a CRHWP, single detectors can measure three of the Stokes parameters, I, Q and U, thereby avoiding the set of systematic errors that can be introduced by mismatches in the properties of orthogonal detector pairs. We focus on the implementation of CRHWPs in large aperture telescopes (i.e. the primary mirror is larger than the current maximum half-wave plate diameter of ~0.5 m), where the CRHWP can be placed between the primary mirror and focal plane. In this configuration, one needs to address the intensity to polarization (I→P) leakage of the optics, which becomes a source of 1/f noise and also causes differential gain systematics that arise from CMB temperature fluctuations. In this paper, we present the performance of a CRHWP installed in the {\scshape Polarbear} experiment, which employs a Gregorian telescope with a 2.5 m primary illumination pattern. The CRHWP is placed near the prime focus between the primary and secondary mirrors. We find that the I→P leakage is larger than the expectation from the physical properties of our primary mirror, resulting in a 1/f knee of 100 mHz. The excess leakage could be due to imperfections in the detector system, i.e. detector non-linearity in the responsivity and time-constant. We demonstrate, however, that by subtracting the leakage correlated with the intensity signal, the 1/f noise knee frequency is reduced to 32 mHz (ℓ ~ 39 for our scan strategy), which is very promising to probe the primordial B-mode signal. We also discuss methods for further noise subtraction in future projects where the precise temperature control of instrumental components and the leakage reduction will play a key role.

79 ASTRONOMY AND ASTROPHYSICS↗

Noise radiation from the side edges of flaps

The recently observed phenomenon of high noise radiation from the side edges of flaps in flow is investigated by way of a simple two-dimensional model problem. The model is based upon a physical picture of boundary layer vorticity being swept around the edge by spanwise flow on the flap. The model problem is developed and solved and the resulting noise radiation calculated. Further, a mathematical condition for the vortex to be captured by the potential flow and swept around the edge is derived. The results show that the sound generation depends strongly upon the strength of the vorticity and distance from the edge and that it can be more intense than the more common trailing edge noise source in agreement with the experimental observations.

Hardin, J. C.↗

Calibration of 2-D soil zymography for correct analysis of enzyme distribution

Soil zymography is a new technique developed to visualize two-dimensional distributions of enzyme activities. The method is composed of incubating a membrane saturated with an enzyme-specific fluorogenic substrate on a surface of the soil sample, followed by recording the membrane image generated by a fluorescent product (e.g. MUF: methylumbelliferone) in ultraviolet light. Despite its relative ease of use, performing zymography involves multiple user-made decisions that might affect the accuracy of enzyme activity estimates. Thus, unification of the zymography methodology is required for correct estimations and comparisons of various studies. We investigated the following methodological aspects of the implementation of zymography: (a) camera settings and image processing, (b) effects of evaporation and (c) calibration procedures. Camera settings (shutter speeds or exposure time) affected the intensity of background fluorescence and signal-to-noise ratios (SNR). However, because their combined effects varied depending on MUF concentrations, light and camera setting need to be optimized for the expected range of MUF concentrations prior to zymography. Evaporation of MUF solution from the membrane had no effect on fluorescence. Relations between MUF concentration and intensity of fluorescence during calibrations demonstrated a saturated pattern and were strongly affected by image noise outside the optimal range (e.g. 8–14 μm MUF pixel -1 ). We developed a new calibration approach that is based on a piecewise linear regression. The new approach accounted for specific ranges of MUF concentration and uses nonuniformly saturated membranes, reflecting the real distribution of enzyme activities in soil. The new calibration algorithm eliminated biases of the standard calibration and resulted in greater accuracy in predicting MUF concentrations.

59 BASIC BIOLOGICAL SCIENCES↗

SU-D-BRF-03: Improvement of TomoTherapy Megavoltage Topogram Image Quality for Automatic Registration During Patient Localization

Purpose: To improve the quality of mega-voltage orthogonal scout images (MV topograms) for a fast and low-dose alternative technique for patient localization on the TomoTherapy HiART system. Methods: Digitally reconstructed radiographs (DRR) of anthropomorphic head and pelvis phantoms were synthesized from kVCT under TomoTherapy geometry (kV-DRR). Lateral (LAT) and anterior-posterior (AP) aligned topograms were acquired with couch speeds of 1cm/s, 2cm/s, and 3cm/s. The phantoms were rigidly translated in all spatial directions with known offsets in increments of 5mm, 10mm, and 15mm to simulate daily positioning errors. The contrast of the MV topograms was automatically adjusted based on the image intensity characteristics. A low-pass fast Fourier transform filter removed high-frequency noise and a Weiner filter reduced stochastic noise caused by scattered radiation to the detector array. An intensity-based image registration algorithm was used to register the MV topograms to a corresponding kV-DRR by minimizing the mean square error between corresponding pixel intensities. The registration accuracy was assessed by comparing the normalized cross correlation coefficients (NCC) between the registered topograms and the kV-DRR. The applied phantom offsets were determined by registering the MV topograms with the kV-DRR and recovering the spatial translation of the MV topograms. Results: The automatic registration technique provided millimeter accuracy and was robust for the deformed MV topograms for three tested couch speeds. The lowest average NCC for all AP and LAT MV topograms was 0.96 for the head phantom and 0.93 for the pelvis phantom. The offsets were recovered to within 1.6mm and 6.5mm for the processed and the original MV topograms respectively. Conclusion: Automatic registration of the processed MV topograms to a corresponding kV-DRR recovered simulated daily positioning errors that were accurate to the order of a millimeter. These results suggest the clinical use of MV topograms as a promising alternative to MVCT patient alignment.

60 APPLIED LIFE SCIENCES↗

Exposure time for space-borne IR spatial interferometer

A mathematical analysis is performed to determine the relationship between the signal-to-noise ratio and the exposure time for an orbiting IR heterodyne spatial interferometer. The analysis includes consideration of the transformation of the interferogram to obtain the source angular intensity distribution so that the signal-to-noise ratio pertains to the angular distribution rather than to the interferogram. The analysis is applied to a number of known IR sources. The results presented show that an interferometer with a 30-m baseline using half-meter telescopes should be able to image a source such as IRC + 30219 with a signal-to-noise ratio of 10 in a total exposure time of less than an hour.

Wolfe, R. H., Jr.↗

X-ray variability of Scorpius X-1 during a multiwavelength campaign

Consideration is given to the X-ray variability of Scorpius X-1, which was observed with Ginga on March 9-11, 1989 as part of a multiwavelength campaign. The temporal characteristics observed, including quasi-periodic oscillations, HF noise, and VLF noise, are consistent with previous observations of Sco X-1. Quasi-periodic oscillations are observed on both the normal branch and the lower flaring branch, but not on the upper flaring branch. Limits are placed on the fractional rms variation of quasi-period oscillations on the upper flaring branch of less than or approximately equal to 2 percent of the total intensity. The characteristics of the observed red noise components are found to vary along the flaring branch. The fractional rms variation of VLF noise increases from less than 2 to greater than 6 percent as Sco X-1 moves from the flaring branch-normal branch vertex to the upper end of the flaring branch.

Hertz, P.↗

Probing the localization of magnetic dichroism by atomic-size astigmatic and vortex electron beams

We report localization of a magnetic dichroic signal on atomic columns in electron magnetic circular dichroism (EMCD), probed by beam distorted by four-fold astigmatism and electron vortex beam. With astigmatic probe, magnetic signal to noise ratio can be enhanced by blocking the intensity from the central part of probe. However, the simulations show that for atomic resolution magnetic measurements, vortex beam is a more effective probe, with much higher magnetic signal to noise ratio. For all considered beam shapes, the optimal SNR constrains the signal detection at low collection angles of approximately 6–8 mrad. Irrespective of the material thickness, the magnetic signal remains strongly localized within the probed atomic column with vortex beam, whereas for astigmatic probes, the magnetic signal originates mostly from the nearest neighbor atomic columns. Due to excellent signal localization at probing individual atomic columns, vortex beams are predicted to be a strong candidate for studying the crystal site specific magnetic properties, magnetic properties at interfaces, or magnetism arising from individual atomic impurities.

36 MATERIALS SCIENCE↗

Quantum fluctuations of radiation in a ring Nd : YAG chip laser

We report theoretical and experimental investigation of intensity fluctuations in a travelling-wave ring Nd : YAG chip laser, caused by the noise of spontaneous emission. In accordance with theory and experiment, quantum intensity fluctuations in the laser under study decrease dramatically with increasing pump over the threshold. As a result of the research performed, the factor β is found, which determines the ratio of the rate of spontaneous emission into the generated mode to the total rate of spontaneous emission into all modes. The effect of the relaxation rate from the lower laser level on quantum fluctuations of the radiation intensity is found. (control of radiation parameters)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Study of the Acoustic Effects of Hydrokinetic Tidal Turbines in Admiralty Inlet, Puget Sound

Hydrokinetic turbines will be a source of noise in the marine environment - both during operation and during installation/removal. High intensity sound can cause injury or behavioral changes in marine mammals and may also affect fish and invertebrates. These noise effects are, however, highly dependent on the individual marine animals; the intensity, frequency, and duration of the sound; and context in which the sound is received. In other words, production of sound is a necessary, but not sufficient, condition for an environmental impact. At a workshop on the environmental effects of tidal energy development, experts identified sound produced by turbines as an area of potentially significant impact, but also high uncertainty.

54 ENVIRONMENTAL SCIENCES↗

A beamline for ultrafast extreme ultraviolet magneto-optical spectroscopy in reflection near the shot noise limit

High harmonic generation (HHG) makes it possible to measure spin and charge dynamics in materials on femtosecond to attosecond timescales. However, the extreme nonlinear nature of the high harmonic process means that intensity fluctuations can limit measurement sensitivity. Here we present a noise-canceled, tabletop high harmonic beamline for time-resolved reflection mode spectroscopy of magnetic materials. We use a reference spectrometer to independently normalize the intensity fluctuations of each harmonic order and eliminate long term drift, allowing us to make spectroscopic measurements near the shot noise limit. Here, these improvements allow us to significantly reduce the integration time required for high signal-to-noise (SNR) measurements of element-specific spin dynamics. Looking forward, improvements in the HHG flux, optical coatings, and grating design can further reduce the acquisition time for high SNR measurements by 1–2 orders of magnitude, enabling dramatically improved sensitivity to spin, charge, and phonon dynamics in magnetic materials.

47 OTHER INSTRUMENTATION↗

COSMIC INFRARED BACKGROUND FLUCTUATIONS AND ZODIACAL LIGHT

We performed a specific observational test to measure the effect that the zodiacal light can have on measurements of the spatial fluctuations of the near-IR background. Previous estimates of possible fluctuations caused by zodiacal light have often been extrapolated from observations of the thermal emission at longer wavelengths and low angular resolution or from IRAC observations of high-latitude fields where zodiacal light is faint and not strongly varying with time. The new observations analyzed here target the COSMOS field at low ecliptic latitude where the zodiacal light intensity varies by factors of ∼2 over the range of solar elongations at which the field can be observed. We find that the white-noise component of the spatial power spectrum of the background is correlated with the modeled zodiacal light intensity. Roughly half of the measured white noise is correlated with the zodiacal light, but a more detailed interpretation of the white noise is hampered by systematic uncertainties that are evident in the zodiacal light model. At large angular scales (≳100″) where excess power above the white noise is observed, we find no correlation of the power with the modeled intensity of the zodiacal light. This test clearly indicates that the large-scale power in the infrared background is not being caused by the zodiacal light.

79 ASTRONOMY AND ASTROPHYSICS↗

Cosmic Infrared Background Fluctuations and Zodiacal Light

We performed a specific observational test to measure the effect that the zodiacal light can have on measurements of the spatial fluctuations of the near-IR (near-infrared)background. Previous estimates of possible fluctuations caused by zodiacal light have often been extrapolated from observations of the thermal emission at longer wavelengths and low angular resolution or from IRAC (Infrared Array Camera) observations of high-latitude fields where zodiacal light is faint and not strongly varying with time. The new observations analyzed here target the COSMOS (Cosmic Evolution Survey) field at low ecliptic latitude where the zodiacal light intensity varies by factors of approximately 2 over the range of solar elongations at which the field can be observed. We find that the white-noise component of the spatial power spectrum of the background is correlated with the modeled zodiacal light intensity. Roughly half of the measured white noise is correlated with the zodiacal light, but a more detailed interpretation of the white noise is hampered by systematic uncertainties that are evident in the zodiacal light model. At large angular scales (greater than or approximately equal to 100 arcseconds) where excess power above the white noise is observed, we find no correlation of the power with the modeled intensity of the zodiacal light. This test clearly indicates that the large-scale power in the infrared background is not being caused by the zodiacal light.

cosmology: observations aEuro" diffuse radiation a↗

Characterization of Pump-Induced Acoustics in Space Launch System Main Propulsion System Liquid Hydrogen Feedline Using Airflow Test Data

High intensity acoustic edgetones located upstream of the RS-25 Low Pressure Fuel Turbo Pump (LPFTP) were previously observed during Space Launch System (STS) airflow testing of a model Main Propulsion System (MPS) liquid hydrogen (LH2) feedline mated to a modified LPFTP. MPS hardware has been adapted to mitigate the problematic edgetones as part of the Space Launch System (SLS) program. A follow-on airflow test campaign has subjected the adapted hardware to tests mimicking STS-era airflow conditions, and this manuscript describes acoustic environment identification and characterization born from the latest test results. Fluid dynamics responsible for driving discrete excitations were well reproduced using legacy hardware. The modified design was found insensitive to high intensity edgetone-like discretes over the bandwidth of interest to SLS MPS unsteady environments. Rather, the natural acoustics of the test article were observed to respond in a narrowband-random/mixed discrete manner to broadband noise thought generated by the flow field. The intensity of these responses were several orders of magnitude reduced from those driven by edgetones.

Eberhart, C. J.↗

Improvement in the Accuracy of Flux Measurement of Radio Sources by Exploiting an Arithmetic Pattern in Photon Bunching Noise

A hierarchy of statistics of increasing sophistication and accuracy is proposed to exploit an interesting and fundamental arithmetic structure in the photon bunching noise of incoherent light of large photon occupation number, with the purpose of suppressing the noise and rendering a more reliable and unbiased measurement of the light intensity. The method does not require any new hardware, rather it operates at the software level with the help of high-precision computers to reprocess the intensity time series of the incident light to create a new series with smaller bunching noise coherence length. The ultimate accuracy improvement of this method of flux measurement is limited by the timing resolution of the detector and the photon occupation number of the beam (the higher the photon number the better the performance). The principal application is accuracy improvement in the signal-limited bolometric flux measurement of a radio source.

79 ASTRONOMY AND ASTROPHYSICS↗

Correlation between spectral state and quasi-periodic oscillation parameters in GX 5-1

In a series of seven Exosat observations, the bimodal spectral behavior and the quasi-periodic oscillation (QPO)/red noise properties of GX 5-1 show a strict correlation. In one of the two spectral states (characterized by a 'horizontal branch' in the hardness-intensity diagram), strong 20-40 Hz QPO and red noise below about 60 Hz were always present. In the other ('normal branch'), no QPO between 6 and 60 Hz or red noise above 1 Hz were detected, but there was an indication for weak QPO near 5 Hz. In both states 'very low frequency noise' (VLFN) is detected below 0.1 Hz which has a power-law shape and and which extends down to the lowest observed frequencies (0.0001 Hz). The VLFN is probably not directly related to the QPO. The results are compared to those on Sco X-1 and Cyg X-2 and it is concluded that, although all three sources show bimodal spectral and QPO/red noise behavior, there is a qualitative difference between GX 5-1 and Cyg X-2 on one hand and Sco X-1 on the other.

Van Der Klis, M.↗

Magneto-Optical Sensing Beyond the Shot Noise Limit

Magneto-optical sensors including spin noise spectroscopies and magneto-optical Kerr effect microscopies are now ubiquitous tools for materials characterization that can provide new understanding of spin dynamics, hyperfine interactions, spin-orbit interactions, and charge-carrier g-factors. Both interferometric and intensity-difference measurements can provide photon-shot-noise-limited sensitivity, but further improvements in sensitivity with classical resources require either increased laser power that can induce unwanted heating and electronic perturbations or increased measurement times that can obscure out-of-equilibrium dynamics and slow experimental throughput. Proof-of-principle measurements have already demonstrated quantum enhanced spin noise measurements with a squeezed readout field that are likely to be critical to the nonperturbative characterization of spin excitations in quantum materials that emerge at low temperatures. Here, a truncated nonlinear interferometric readout for low-temperature magneto-optical Kerr effect and related magneto-optical microscopies that is accessible with today's quantum optical resources is proposed. 10 nrad/$\sqrt{Hz}$ sensitivity is achievable with optical power as small as 1 µW. As a result, measurements may be performed at temperatures as low as 83 mK in commercially available dilution refrigerators. This combination of high sensitivity and low operating temperature is impossible to achieve with any classical measurement. The quantum advantage for the proposed measurements persists even in the limit of large loss and small squeezing parameters.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗