Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “NODES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Comparison of plug flow and multi-node stratified tank modeling approaches regarding computational efficiency and accuracy

Residential water heaters contain water stratified by temperature-driven density differences. This implies that a water tank can reach a state in which the top and bottom sections have different temperatures, unless mixing happens. A high degree of thermal stratification can improve the efficiency of some water heaters, by saving the amount of energy required for the heat-up process. Studies of stratification became popular in the 1970s and it remains an active research topic today. The research has led to the development of different models and techniques to better predict and define a stratified tanks behavior. By comparing these models and techniques used previously to describe thermal stratification, the phenomenon could be better understood, exploited, and used to increase efficiency and thermal energy capacity in modern water tanks. From the existing models, we found the one-dimensional standard plug-flow and a multi node model to be appropriate for analyzing the processes of the heat up and cool-down in a water tank. These two models are based on energy balances. This work involved comparing the accuracy and computational effort needed to implement these models. To assess accuracy, we compared both types of existing models to experimental data (also collected in this work) which included a heat up process using an external heat pump. This external process included a layering process that has an eddy diffusivity at five times the rate of thermal diffusion. For this project, we implemented the models in MATLAB, the multi-paradigm numerical computing environment. We quantified model accuracy using the root mean squared error between modeled data and experimental data for six measured tank temperatures. Comparing the accuracy and the computational time taken to run the simulation provides a method to contrast the performance of each model and a way to rate it. The multi node model was run using from 6 to 96 spatial nodes; the plug flow model was run using 1 to 0.001 º C temperature bin sizes. Additionally, timesteps were varied from 4 to 236 s. The results quantify the tradeoff between accuracy and computational time, providing guidance for simulations to intelligently select the best model type and simulation parameters. This research can be used to validate the pre-existing models and possibly improve the modern water tank.

Bulnes, Fernando Karg↗

Carrier and sampling frequency offset estimation for RF communication with crystal-less nodes

When the ultra-low power mm-scale sensor node does not have a crystal oscillator and phase-lock loop, it inevitably exhibits significant carrier frequency offset (CFO) and sampling frequency offset (SFO) with respect to the reference frequencies in the gateway. This disclosure enables efficient real-time calculation of accurate SFO and CFO at the gateway, thus the ultra-low power mm-scale sensor node can be realized without a costly and bulky clock reference crystal and also power-hungry phase lock loop. In the proposed system, the crystal-less sensor starts transmission with repetitive RF pulses with a constant interval, followed by the data payload using pulse-position modulation (PPM). A proposed algorithm uses a two-dimensional (2D) fast Fourier transform (FFT) based process that identifies the SFO and CFO at the same time to establish successful wireless communication between the gateway and crystal-less sensor nodes.

Kim, Hun-Seok↗

Scalable I/O Systems via Node-Local Storage: Approaching 1 TB/sec File I/O

The growth in the computational capability of modern supercomputing systems has been accompanied by corresponding increases in CPU count, total RAM, and total storage capacity. Indeed, systems such as Blue-Gene/L [3], BlueGene/P, Ranger, and the Cray XT series have grown to more than 100k processors, with 100 TeraBytes of RAM and are attached to multi-PetaByte storage systems. However, as part of this design evolution, large supercomputers have lost node-local storage elements, such as disks. While this decision was motivated by important considerations like overall system reliability, it also resulted in these systems losing a key level in their memory hierarchy, with nothing to fill the gap between local RAM and the parallel file system. While today's large supercomputers are typically attached to fast parallel file systems, which provide tens of GBs/s of I/O bandwidth, the computational capacity has grown much faster than the storage bandwidth capacity. As such, these machines are now provided with much less than 1GB/s of I/O bandwidth per TeraFlop of compute power, which is below the generally accepted limit required for a well-balanced system [8] [16]. The result is that today's limited I/O bandwidth is choking the capabilities of modern supercomputers, specifically in terms of limiting their working sets and making fault tolerance techniques, such as checkpointing, prohibitively expensive. This paper presents an alternative system design oriented on using node-local storage to improve aggregate system I/O bandwidth. We focus on the checkpointing use-case and present an experimental evaluation of SCR, a new checkpointing library that makes use of node-local storage to significantly improve the performance of checkpointing on large-scale supercomputers. Experiments show that SCR achieves unprecedented write speeds, reaching 700GB/s on 8,752 processors. Our results scale such that we expect a similarly structured system consisting of 12,500 processors to achieve aggregate I/O bandwidth of 1 TB/s.

99 GENERAL AND MISCELLANEOUS↗

Slow Nodes Cost Your Users Valuable Resources. Can You Find Them?

Many High Performance Computing applications have a static load balance which is easy and cheap to implement. When one or a few nodes are not performing properly this makes the whole code slow down to the rate limiting performance of the slowest node. We describe the utilization of a coded called Bugget which has been used on Catamount and the Cray Linux Environment to quickly identify these nodes so they can be removed from the user pool until the next appropriate maintenance period.

99 GENERAL AND MISCELLANEOUS↗

Multiscale wireless sensor node for impedance-based SHM and low-frequency vibration data acquisition

This paper presents recent developments in an extremely compact, wireless impedance sensor node (WID3, Wireless Impedance Device) at Los Alamos National Laboratory for use in impedance-based structural health monitoring (SHM), Sensor diagnostics and low-frequency vibrational data acquisition. The current generation WID3 is equipped with an Analog Devices AD5933 impedance chip that can resolve measurements up to 100 kHz, a frequency range ideal for many SHM applications. An integrated set of multiplexers allows the end user to monitor seven piezoelectric sensors from a single sensor node. The WID3 combines on-board processing using an Atmega1281 microcontroller, data storage using flash memory, wireless communications capabilities, and a series of internal and external triggering options into a single package to realize a truly comprehensive, self-contained wireless active-sensor node for SHM applications. Furthermore, we recently extended the capability of this device by implementing low-frequency analog to digital and digital and analog converters so that the same device can measure structural vibration data. The WID3 requires less than 70 mW of power to operate, and it can operate in various wireless network paradigms. The performance of this miniaturized and portable device is compared to our previous results and its broader capabilities are demonstrated.

42 ENGINEERING↗

Particle removal challenges with EUV patterned mask for the sub-22nm HP node

The particle removal efficiency (PRE) of cleaning processes diminishes whenever the minimum defect size for a specific technology node becomes smaller. For the sub-22 nm half-pitch (HP) node, it was demonstrated that exposure to high power megasonic up to 200 W/cm{sup 2} did not damage 60 nm wide TaBN absorber lines corresponding to the 16 nm HP node on wafer. An ammonium hydroxide mixture and megasonics removes {ge}50 nm SiO{sub 2} particles with a very high PRE, A sulfuric acid hydrogen peroxide mixture (SPM) in addition to ammonium hydroxide mixture (APM) and megasonic is required to remove {ge}28 nm SiO{sub 2} particles with a high PRE. Time-of-flight secondary ion mass spectroscopy (TOFSIMS) studies show that the presence of O{sub 2} during a vacuum ultraviolet (VUV) ({lambda} = 172 nm) surface conditioning step will result in both surface oxidation and Ru removal, which drastically reduce extreme ultraviolet (EUV) mask life time under multiple cleanings. New EUV mask cleaning processes show negligible or no EUV reflectivity loss and no increase in surface roughness after up to 15 cleaning cycles. Reviewing of defect with a high current density scanning electron microscope (SEM) drastically reduces PRE and deforms SiO{sub 2} particles. 28 nm SiO{sub 2} particles on EUV masks age very fast and will deform over time, Care must be taken when reviewing EUV mask defects by SEM. Potentially new particles should be identified to calibrate short wavelength inspection tools, Based on actinic image review, 50 nm SiO{sub 2} particles on top of the EUV mask will be printed on the wafer.

36 MATERIALS SCIENCE↗

Pancreatic neuroendocrine tumors: MR imaging features preoperatively predict lymph node metastasis

Purposes: Predictive factors of lymph node metastasis (LNM) in pancreatic neuroendocrine tumors (pNETs) are not well established. We sought to identify the value of MR imaging features in preoperatively predicting the lymph node metastasis of pNETs. Materials and methods: In this study, we enrolled 108 consecutive patients with pNETs between January 2009 and June 2018. MR morphologic features and quantitative data were evaluated. Predictors of LNM were evaluated using univariate and multivariate logistic regression models. Results: A total of 108 patients with pNETs were finally enrolled, including 82 LNM-negative and 26 LNM-positive patients. Features significantly related to the LNM of pNETs at univariate analysis were tumor size > 2 cm (P = 0.003), Ki-67 > 5% (P = 0.002), non-enhancement pattern (P < 0.001), apparent diffusion coefficient value (P < 0.001), main pancreatic duct dilation (P < 0.001) and pancreatic atrophy (P = 0.032) and extrapancreatic tumor spread (P = 0.001), CNRs during arterial, portal and delay phase (P = 0.005, 0.047, and 0.045, respectively), and histological classification (P = 0.006). At multivariate analysis, non-enhancement pattern (P = 0.019; odds ratio, 6.652; 95% CI 1.369, 32.321) and main pancreatic duct dilation (P = 0.018; odds ratio, 6.745; 95% CI 1.379, 32.991) were independent risk factors for predicting the LNM of pNETs. Conclusion: The non-enhancement characteristic and main pancreatic duct dilation appear to be linked with LNM in pNETs. These radiological predictors can be easily obtained preoperatively, and may help to avoid missing pNETs with a high risk of LNM.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Activin type IB receptor signaling in prostate cancer cells promotes lymph node metastasis in a xenograft model

Highlights: Black-Right-Pointing-Pointer ActRIB signaling induces Snail and S100A4 expressions in prostate cancer cells. Black-Right-Pointing-Pointer The prostate cancer cell lines expressing an active form of ActRIB were established. Black-Right-Pointing-Pointer ActRIB signaling promotes EMT and lymph node metastasis in xenograft model. -- Abstract: Activin, a member of the transforming growth factor-{beta} family, has been known to be a growth and differentiating factor. Despite its pluripotent effects, the roles of activin signaling in prostate cancer pathogenesis are still unclear. In this study, we established several cell lines that express a constitutive active form of activin type IB receptor (ActRIBCA) in human prostate cancer cells, ALVA41 (ALVA-ActRIBCA). There was no apparent change in the proliferation of ALVA-ActRIBCA cells in vitro; however, their migratory ability was significantly enhanced. In a xenograft model, histological analysis revealed that the expression of Snail, a cell-adhesion-suppressing transcription factor, was dramatically increased in ALVA-ActRIBCA tumors, indicating epithelial mesenchymal transition (EMT). Finally, mice bearing ALVA-ActRIBCA cells developed multiple lymph node metastases. In this study, we demonstrated that ActRIBCA signaling can promote cell migration in prostate cancer cells via a network of signaling molecules that work together to trigger the process of EMT, and thereby aid in the aggressiveness and progression of prostate cancers.

60 APPLIED LIFE SCIENCES↗

Implementation of extrinsic cohesive zone model (ECZM) in 2D finite-discrete element method (FDEM) using node binding scheme

The combined finite-discrete element method (FDEM) has been widely used for rock fracturing simulations. Conventionally, FDEM is realized using the intrinsic cohesive zone model (ICZM); however, it has the drawback of artificial compliance and high computational expense. As a complement, the extrinsic cohesive zone model (ECZM) is seen to be realized in FDEM recently, whereas the node splitting scheme utilized is cumbersome. Here, within the framework of ICZM-based FDEM, we propose a node binding scheme to efficiently bind the pre-discretized finite elements and thus guarantee the continuum behavior of materials in the elastic stage. The yield surfaces, controlled by ECZM, are dynamically embedded by invoking the pre-inserted cohesive elements. The effectiveness and efficiency of the proposed approach are validated and tested by performing a suite of numerical experiments. Compared with ICZM-based FDEM, the proposed approach can correctly capture material deformation and reduce the computation cost. In contrast to the existing ECZM-based FDEM, the proposed approach can overcome the frequent and complex element topology updating. Finally, this work provides a novel perspective that fully inherits the advantages of both ICZM and ECZM, but circumvents their shortcomings, which guarantees a more efficient and effective simulation of brittle material evolution from continuum to discontinuum.

58 GEOSCIENCES↗

Integrated reactor architecture of conductive network and catalytic nodes to accelerate polysulfide conversion for durable and high-loading Li-S batteries

The development of carbon-based heterogeneous framework host with synergistic catalytic and conductive effects for sulfur cathode is a promising strategy to realize high performance lithium sulfur batteries (LSBs). Here, an integrated reactor architecture with defective carbon nodes (IRA-DC) is designed for serving as high-loading (92.4 wt%) sulfur host. The hierarchical porous IRA-DC consists of untangled conductive carbon nanotube network and Co/N co-doped catalytic nodes with high dispersity. Therein the optimization of electric field distribution and homogenization of adsorption-catalysis sites offer the multi-electron conversion reaction of polysulfides with excellent kinetics and stability. The resultant IRA-DC/S cathode enables a high areal capacity of 8.86 mAh cm -2 under ultra-high sulfur loading (13.1 mg cm -2 ) and lean electrolyte (8 μL mg sulfur -1 ). It also displays a long-term cycling performance (1200 cycles at 1 C) and ultrahigh rate performance up to 20 C (with a capacity of 473.6 mAh g -1 ). In conclusion, this work provides an electrode building strategy by optimizing the environments of heterogeneous electrocatalysis and micro electric field to activate the polysulfide conversion efficiency and utilization of high-loading sulfur in monolithic sulfur-carbon cathodes.

25 ENERGY STORAGE↗

Radiation Therapy for Cutaneous Squamous Cell Carcinoma Involving the Parotid Area Lymph Nodes: Dose and Volume Considerations

Purpose: The intraparotid and periparotid lymph nodes are the most commonly involved when skin cancer of the head and neck metastasizes beyond the primary site. We sought to report the clinical outcome of patients treated with radiation therapy for parotid-area metastases from cutaneous squamous cell carcinoma of the head and neck. Methods and Materials: The records of 36 patients treated with radiation therapy for cutaneous squamous cell carcinoma involving the parotid-area lymph nodes were reviewed. All patients had clinically N0 necks and were without evidence of distant disease. Thirty patients (83%) were treated postoperatively after gross total tumor resection. Median dose to the parotid area was 60 Gy (range, 50-72 Gy). Treatment of clinically N0 necks consisted of surgical dissection (7 patients), irradiation (15 patients), and observation (14 patients). Results: The 5-year estimate of local (parotid) control was 86% in patients treated using surgery with postoperative therapy and 47% in patients treated using radiation therapy alone. Three of 4 patients with tumors that relapsed locally after surgery and postoperative radiation received a dose of less than 60 Gy. Elective neck irradiation decreased the incidence of subsequent nodal failures from 50% to 0% and significantly improved neck control (p < 0.001). The 5-year overall survival rate was 63%. Conclusions: Surgery followed by radiation therapy to doses of at least 60 Gy results in effective local control for patients with parotid area metastasis from cutaneous squamous cell carcinoma. Routine irradiation of the clinically N0 neck is recommended.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Newer Imaging Modalities to Assist With Target Localization in the Radiation Treatment of Prostate Cancer and Possible Lymph Node Metastases

Precise localization of prostate cancer and the drainage lymph nodes is mandatory to define an accurate clinical target volume for conformal radiotherapy. Better target definition and delineation on a daily basis is surely important in quality assurance for fractionated radiation therapy. This article reviews the evidence for major emerging techniques that show promise in better identifying the clinical target volume. Partial prostate boost by brachytherapy, intensity-modulated radiation therapy, or protons has become possible not only with standard imaging techniques but also with the availability of metabolic images obtained by magnetic resonance spectroscopy. Even though fluorine-18 fluorodeoxyglucose ({sup 18}F-FDG) positron emission tomography has not been found to be useful, novel radiolabeled tracers may eventually prove of value in the diagnosis and treatment planning of prostate cancer. For the metastatic lymph nodes, lymphotropic nanoparticle-enhanced magnetic resonance imaging using ultra-small superparamagnetic iron oxide particles has greater accuracy as compared with conventional techniques and has been instrumental in delineating the lymphatic drainage of the prostate gland. These novel investigational techniques could further help in optimizing conformal radiotherapy for patients with prostate cancer. The concepts of biologic target volume, real target volume, and multidimensional conformal radiotherapy are being explored.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Cyclooxygenase-2 Expression as a Predictor of Para-Aortic Lymph Node Recurrence in Uterine Cervical Cancer

Purpose: The overexpression of cyclooxygenase-2 (COX-2) is associated with a worse prognosis and the development of distant metastases in cervical cancer. This matched-pair analysis examined whether COX-2 expression is associated with para-aortic lymph node (PALN) recurrence in uterine cervical cancer treated with radiotherapy (RT). Methods and Materials: For this study, we matched 20 patients with PALN recurrence after definitive or postoperative RT by stage with 20 others who did not have PALN recurrence. Of the 20 patients with PALN recurrence, definitive or postoperative RT was performed in 11 and 9 patients, respectively. COX-2 expression was assessed immunohistochemically using a mouse monoclonal antibody on formalin-fixed paraffin-embedded tumor specimens taken before RT. A logistic regression model was used to predict for PALN recurrence. Results: COX-2 was expressed in 28 (70%) of the 40 patients. The staining intensity was as follows: weak in 19 (47%), moderate in 6 (15%), and strong in 3 (8%) patients. The patients with PALN recurrence had much greater expression of COX-2 (17 patients, 85%) than did the control group (11 patients, 55%; p = 0.04). Strong staining intensity of COX-2 was seen only in the PALN recurrence group. The statistically significant factors associated with PALN recurrence were positive pelvic lymph nodes (odds ratio, 7.61; 95% confidence interval, 1.55-37.37; p = 0.01) and COX-2 expression (odds ratio, 1.47; 95% confidence interval, 1.04-2.09; p = 0.03). Conclusion: Our findings suggest that COX-2 overexpression in the initial tumor tissue might be associated with PALN recurrence after RT in cervical cancer patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of Breast Sentinel Lymph Node Coverage by Standard Radiation Therapy Fields

Background: Biopsy of the breast sentinel lymph node (SLN) is now a standard staging procedure for early-stage invasive breast cancer. The anatomic location of the breast SLN and its relationship to standard radiation fields has not been described. Methods and Materials: A retrospective review of radiotherapy treatment planning data sets was performed in patients with breast cancer who had undergone SLN biopsy, and those with a surgical clip at the SLN biopsy site were identified. The location of the clip was evaluated relative to vertebral body level on an anterior-posterior digitally reconstructed radiograph, treated whole-breast tangential radiation fields, and standard axillary fields in 106 data sets meeting these criteria. Results: The breast SLN varied in vertebral body level position, ranging from T2 to T7 but most commonly opposite T4. The SLN clip was located below the base of the clavicle in 90%, and hence would be excluded from standard axillary radiotherapy fields where the inferior border is placed at this level. The clip was within the irradiated whole-breast tangent fields in 78%, beneath the superior-posterior corner multileaf collimators in 12%, and outside the tangent field borders in 10%. Conclusions: Standard axillary fields do not encompass the lymph nodes at highest risk of containing tumor in breast cancer patients. Elimination of the superior-posterior corner MLCs from the tangent field design would result in inclusion of the breast SLN in 90% of patients treated with standard whole-breast irradiation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Intensity-Modulated Radiotherapy for Cervical Lymph Node Metastases From Unknown Primary Cancer

Purpose: To compare the effectiveness of intensity-modulated radiotherapy (IMRT) and conventional (two-dimensional) radiotherapy in the treatment of cervical lymph node metastases from unknown primary cancer (UPC). Methods and Materials: Between February 2003 and September 2006, 23 patients with UPC of squamous cell carcinoma were treated with IMRT. Extended putative mucosal and bilateral nodal sites were irradiated to a median dose of 66 Gy. In 19 patients, IMRT was performed after lymph node dissection, and in 4 patients primary radiotherapy was given. The conventional radiotherapy group (historical control group) comprised 18 patients treated to a median dose of 66 Gy between August 1994 and October 2003. Results: Twenty patients completed treatment. As compared with conventional radiotherapy, the incidence of Grade 3 acute dysphagia was significantly lower in the IMRT group (4.5% vs. 50%, p = 0.003). By 6 months, Grade 3 xerostomia was detected in 11.8% patients in the IMRT group vs. 53.4% in the historical control group (p = 0.03). No Grade 3 dysphagia or skin fibrosis was observed after IMRT but these were noted after conventional radiotherapy (26.7%, p = 0.01) and 26.7%, p = 0.03) respectively). With median follow-up of living patients of 17 months, there was no emergence of primary cancer. One patient had persistent nodal disease and another had nodal relapse at 5 months. Distant metastases were detected in 4 patients. The 2-year overall survival and distant disease-free probability after IMRT did not differ significantly from those for conventional radiotherapy (74.8% vs. 61.1% and 76.3% vs. 68.4%, respectively). Conclusions: Use of IMRT for UPC resulted in lower toxicity than conventional radiotherapy, and was similar in efficacy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Utility of Positron Emission Tomography Compared With Mediastinoscopy for Delineating Involved Lymph Nodes in Stage III Lung Cancer: Insights for Radiotherapy Planning From a Surgical Cohort

Purpose: Mediastinoscopy is routinely carried out on the majority of nonmetastatic, non-small-cell lung cancer (NSCLC) patients in our institution. We used the results of mediastinoscopy from a Stage III NSCLC cohort to assess the reliability of positron emission tomography (PET) scans at identifying involved mediastinal lymph nodes (MLN) when used during radiotherapy planning. Methods and Materials: Mediastinoscopy was the gold standard. Characteristics of PET were calculated for nodal sensitivity. To compare the impact on contouring, theoretical nodal targets (NTs) containing involved MLNs were generated using PET and mediastinoscopy. We determined whether the NT derived from PET (NT-P) was equivalent to, greater than, or less than that seen with the mediastinoscopy (NT-M). Results: Data for 122 patients with Stage III NSCLC, treated between 2000 and 2004, were analyzed. After exclusions, 87 patients with Stage III disease by mediastinoscopy were analyzed. Overall PET sensitivity was 61% and positive predictive value was 94%. Of the 87 patients, 33 (38%) had no abnormal MLN findings by PET. Of 36 Stage IIIA cancer patients, 18 (50%) had NT-P equivalent to NT-M, 10 (28%) had smaller NT-Ps, and 8 (22%) had larger NT-Ps compared with NT-Ms. Of 18 Stage IIIB cancer patients, NTs were equivalent in 6 (34%); in 1 patient (5%) NT-P was larger than the corresponding NT-M, and in 11 (61%) smaller than the corresponding NT-M. Conclusions: In this study PET had modest sensitivity to detect MLN involvement and underestimated the extent of involved nodes for target definition. The role of PET in mediastinal contouring needs to be evaluated prospectively and ideally correlated with a pathology standard.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Prospective Clinical Trial of Positron Emission Tomography/Computed Tomography Image-Guided Intensity-Modulated Radiation Therapy for Cervical Carcinoma With Positive Para-Aortic Lymph Nodes

Purpose: To describe a more aggressive treatment technique allowing dose escalation to positive para-aortic lymph nodes (PALN) in patients with cervical cancer, by means of positron emission tomography (PET)/computed tomography (CT)-guided intensity-modulated radiation therapy (IMRT). Here, we describe methods for simulation and planning of these treatments and provide objectives for target coverage as well as normal tissue sparing to guide treatment plan evaluation. Methods and Materials: Patients underwent simulation on a PET/CT scanner. Treatment plans were generated to deliver 60.0 Gy to the PET-positive PALN and 50.0 Gy to the PALN and pelvic lymph node beds. Treatment plans were optimized to deliver at least 95% of the prescribed doses to at least 95% of each target volume. Dose-volume histograms were calculated for normal structures. Results: The plans of 10 patients were reviewed. Target coverage goals were satisfied in all plans. Analysis of dose-volume histograms indicated that treatment plans involved irradiation of approximately 50% of the bowel volume to at least 25.0 Gy, with less than 10% receiving at least 50.0 Gy and less than 1% receiving at least 60.0. With regard to kidney sparing, approximately 50% of the kidney volume received at least 16.0 Gy, less than 5% received at least 50.0 Gy, and less than 1% received at least 60.0 Gy. Conclusions: We have provided treatment simulation and planning methods as well as guidelines for the evaluation of target coverage and normal tissue sparing that should facilitate the more aggressive treatment of cervical cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dose Distribution Analysis of Axillary Lymph Nodes for Three-Dimensional Conformal Radiotherapy With a Field-in-Field Technique for Breast Cancer

Purpose: We previously reported that most of axillary regions could be irradiated by the modified tangential irradiation technique (MTIT). The purpose of this study was to determine whether the three-dimensional conformal radiotherapy (3D-CRT) with a field-in-field technique improves dosimetry for the breast and axillary nodes. Methods and Materials: Fifty patients with left-sided breast cancer were enrolled. With MTIT, we planned the radiation field to be wider in the cranial direction than the standard tangential fields to include the axillary regions. With 3D-CRT, a field-in-field technique was used to spare the heart and contralateral breast to the extent possible by applying the multileaf collimator manually. Dose-volume histograms were compared for the breast, axillary region, heart, lung, and other normal tissues. Results: There were no significant differences in the percent volume of the breast receiving >90% of the prescribed dose (V90) between MTIT and 3D-CRT. The mean V90 of the level I to III axillary regions were increased from 93.7%, 48.2%, and 41.3% with MTIT to 97.6%, 85.8%, and 82.8% with 3D-CRT. 3D-CRT significantly reduced the volume of the heart receiving >30 Gy (mean, 7.6 vs. 15.9 mL), the percent volume of the bilateral lung receiving >20 Gy (7.4% vs. 8.9%), and the volume of other normal tissues receiving >107% of the prescribed dose (0.1 vs. 2.9 mL). Conclusion: The use of 3D-CRT with a field-in-field technique improves axillary node coverage, while decreasing doses to the heart, lungs, and the other normal tissues, compared with MTIT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗