Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “NCSP”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Sensitivity-based Experiment Design Optimization for a Molybdenum Critical Experiment

A lack of intermediate molybdenum benchmarks in the ICSBEP has been identified by LANL, Y-12, and IRSN. This lacking adversely effects criticality safety operations and leaves new differential molybdenum data unvalidated. NCERC is proposing a series of intermediate integral experiments to better the understanding of molybdenum systems. Using MCNP6.2 with the ENDF/B-VIII.0 nuclear data library a single unmoderated and four moderated system designs were identified using a sensitivity optimization method. Each proposed system was found to be at least twice as sensitive to the 95 Mo capture cross section in the URR as the sole existing intermediate molybdenum benchmark in the ISCBEP handbook. The addition of a new molybdenum sensitive intermediate system would improve future nuclear data evaluations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Cumulative $\chi^2$ Metric for VALID for ENDF/B-VII.1 and ENDF/B-VIII.0 in SCALE 6.3b9

Nuclear data testing is generally performed in a manner similar to validation: a series of critical benchmark experiments is modeled, and the differences between calculated and expected results are examined to understand the performance of a code and cross section set. This process is repeated for multiple sets of experiments with different transport codes and sometimes with different datasets. Occasionally, data processing differences are also important in understanding the differences in calculated results. Relevant experts then meet periodically to compare results and set priorities for improvement in the next round of data updates. This process has been largely effective, despite the confounding factors of different benchmark sets, application areas, sponsors, nationalities, and the resulting different priorities.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Validation of Jezebel Reactivity Coefficients and Sensitivity Analysis

Nuclear data validation is often performed today using criticality measurements. The gold standard for criticality measurements is the International Criticality Safety Benchmark Experiment Project (ICSBEP). The validation specifically focuses on the effective multiplication factor ($k_{eff}$). $K_{eff}$ is a relatively easy parameter to infer and has reduced uncertainty due to being at or above critical. However, while $k_{eff}$ is the most documented parameter and its uncertainties and sensitivities have been evaluated in great detail, it cannot be used as a standalone metric to determine inaccuracies in nuclear data (e.g., cross section data, PFNS, nu), which is based on theory, physics, and differential measurements. The Experiments Underpinned by Computational Learning for Improvements in nuclear Data (EUCLID) project aims to identify compensating errors in specific isotope nuclear data by optimally designing experiments that are, or are not sensitive to a suite of measurement parameters beyond $k_{eff}$. By identifying parameters that are sensitive to each other, oppositely sensitive, or have substantial magnitude differences in sensitivity, experiments can be designed to constrain questionable nuclear data. One sensitivity that is of particular interest to this project includes the sensitivity of reactivity coefficients. Reactivity coefficients compare reactivity, which is related to $k_{eff}$ at two different states therefore being sensitive to small changes in the system. The most common type of reactivity coefficient measurements is comparison to void for a small sample within the assembly. It is key that the sample sizes are small enough to not affect the flux of the full system. Reactivity coefficients were evaluated for many early experiments to better understand transport corrected cross sections. In fact, ICSBEP includes reactivity coefficient results as “Supplemental Measurements” in appendices for a handful of older benchmarks. One of those benchmarks is Jezebel, the bare Pu critical assembly. This paper compares new simulations of reactivity coefficients for Jezebel, and explores the sensitivity of reactivity coefficients to small changes in nuclear data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Design of Temperature Dependent Critical Experiments with SPRF/CX

This paper describes the investigation of temperature-dependent critical experiments using the Seven Percent Critical Experiments (7uPCX) and Burnup Credit Critical Experiments (BUCCX) fuel types within the Sandia Pulsed Reactor Facility/Critical Experiments (SPRF/CX) apparatus at Sandia National Laboratories (Sandia). The goal of these experiments is to test the effect of varying system temperature on the $\kappa$ eff bias of water-moderated systems. Temperatures of 5–95°C were considered in this work. Eighteen representative lattice configurations were analyzed that had variations in the number of fuel rods and water holes, as well as in the array configuration, to achieve a variety of moderation regimes. The configurations were based on those detailed in the LEU-COMP-THERM-078 and LEU- COMP-THERM-079 experiments, both of which were published in the International Handbook of Evaluated Criticality Safety Benchmark Experiments (ICSBEP Handbook).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A Verification of Flux Sensitivity Estimates Using the MCNP Tally Perturbation Tool

Nuclear data is commonly used in applications such as nuclear nonproliferation, safeguards, and criticality safety. More specifically, nuclear data is used in predictive simulation codes like the Monte-Carlo N-Particle (MCNP ® ) transport code, Serpent, and similar radiation transport codes. The improvement of nuclear data enables more precise and accurate simulations, which result in higher fidelity designs and reduced operational/procedural costs. Therefore, the improvement of nuclear data is of paramount importance across the nuclear community. Nuclear data is improved and validated through integral benchmark experiments. The design of benchmark experiments is an extensive process; therefore, these experiments are often optimized on multiple characteristics, including sensitivity to the nuclear data, during the design process. Sensitivity is a measure of how much a quantity changes due to changes in independent variables such as experimental configuration. An experimental design that has a larger sensitivity to the nuclear data of interest will have a larger impact on the accuracy and precision of the validated data. Past integral benchmark experiments have primarily used the effective multiplication factor ($k_{eff}$) as the predominant measured quantity; however, experiments designed with other quantities in mind would be able to optimize on validating different areas of the nuclear data. A primary goal of the EUCLID project is to design, constrain, and reduce compensating errors in experiments focused on quantities other than $k_{eff}$ to better validate nuclear data across the board. Currently, there is a capability in MCNP to easily calculate the sensitivity of $k_{eff}$ to specific nuclear data of numerous reactions types and isotopes (KSEN card); however, the sensitivity of other quantities must be estimated in more strenuous manners. For example, the perturbation feature (PERT card) of MCNP can be used to estimate first-order sensitivities of some response in fixed source simulations. A recent announcement revealed that the first- and second-order perturbation features in previous releases of MCNP contained a bug. It was identified that particles were being scored into the wrong energy bin. The bug is in the most recent public release (MCNP6.2); however, a patch has been added to the most up to date version (MCNP6.2.2) that has not been released publicly. A direct comparison of the PERT card results for an F4 (neutron flux averaged over a cell) tally before and after the patch are shown in figure 1. All simulations used in the sensitivity estimates in this report were performed with MCNP6.2.2. This work verifies the patched MCNP perturbation tool by comparing first order sensitivities made using the PERT card to estimates made using manual perturbation of the compact ENDF (ACE) files.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Sensitivity-based Similarity Metrics for New Experiment Design Optimization

The nuclear data used in advanced reactor simulations requires validation. Data from nuclear criticality experiments can provide this validation. New nuclear criticality experiment design requires extensive knowledge and expert judgement such that the experimental design parameters are selected in such a way to keep the experiment subcritical. To aide in this experimental design process, professionals can utilize sensitivity and uncertainty analysis. Sensitivity and uncertainty analysis relies on matching new application experiments with currently existing benchmark experiments. Currently, there is functionality in the Whisper 1.1 software package to calculate a similarity metric based on neutron multiplication factor sensitivity coefficients between a new application designed by the user and existing International Criticality Safety Benchmark Experiment Project (ICSBEP) benchmarks. The Whisper 1.1 software package is included in Monte Carlo N-Particle ® Code Version 6.21 (MCNP ® 6.2). This work is geared toward expanding this capability to new similarity metrics based on beta-effective sensitivity coefficients and reactivity coefficient sensitivity coefficients. While the investigation of these sensitivity coefficients is presented in detail in separate works at this same conference, this work will be primarily focused on studying the similarity metrics in more detail. These similarity metrics will then be incorporated into the optimization algorithms used for experiment design in EUCLID (Experiments Underpinned by Computational Learning for Improvements in nuclear Data), which is a Los Alamos National Laboratory (LANL) project designed to constrain nuclear data of interest, such that adjustments can be made to possible inaccuracies. A more detailed optimization can be subsequently performed by breaking down these similarity metrics by isotope, reaction, and energy.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

FLASSH 1.0: Full Law Analysis Scattering System Hub

Nuclear technologies, such as thermal reactors and critical systems, are driven by reaction rates which are directly dependent on thermal neutrons. The ability to calculate reaction rates is directly linked to the capability to predict and understand the cross sections. For atoms bound within a material structure, the available modes of energy exchange are captured in the Thermal Scattering Law (TSL, i.e. S(α,β)). The TSL is fundamentally a material property and can be defined explicitly to account for the excitation and deexcitation of the lattice energy states. This work describes the development of the Full Law Analysis Scattering System Hub (FLASSH) which calculates the TSL and cross sections. FLASSH is a modern code which has been designed to produce accurate TSL evaluations, remove historical approximations, and improve formulations while making advance physics accessible and simple to use.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Impact of Spontaneous Fission Neutron Emission Energy on Neutron Detector Response

A parametric study was simulated in MCNP to investigate the impact of spontaneous fission neutron energy on neutron detector response. A total of 880 configurations were simulated by varying 3 He pressure and polyethylene reflector thickness for 8 different isotopes. Results showed that deviations between the simulated isotopes become more prevalent at higher energies with 238 U showing the greatest deviation. It was also observed that configurations comparable to most detection setups, 10 atm and 6 - 8 cm polyethylene, were closer to the upper bound of deviations from a 252 Cf. 240 Pu, a common spontaneous fission source of interest, ranged from 2% - 3% within this space. This suggests that further investigation is required to determine exact correction factors when calibrating neutron detectors with a 252 Cf. Although demonstrated here for a 4π-detection system, future plans include simulating a more detailed model of the MC-15 detection setup to determine exact correction factors for future experiments.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Preliminary RAM-RODD results for the MUSiC subcritical configurations

The Measurement of Uranium Subcritical and Critical (MUSiC) was performed at the DOE’s National Criticality Experiments Research Center (NCERC) located in the Nevada National Security Site (NNSS). The measurement utilized the Rocky Flats shells to perform benchmark measurements of similar highly enriched uranium (HEU) systems that span a wide range of reactivities. The Rocky Flats (RF) shells are 93.16% U-235 enriched metal hemishells that can be stacked concentrically. Ten configurations were measured with effective multiplication factors spanning between deeply subcritical (~ 0.64) through delayed critical. Details of the measured configurations are listed in Table 1. This unique set of measurements with its large span of reactivies is being used to determine the range over which neutron noise techniques such as Feynman variance-to-mean, Rossi-alpha, and pulsed neutron source techniques can be accurately employed for a bare HEU system. The results of the measurements will be published as a benchmark in The International Criticality Safety Benchmark Evaluation Project (ICSBEP) Handbook. The results will support the growing amount of subcritical benchmark data, such as the SCRaP measurements, that is available to the community. The measurements were performed using several different detector systems for the purposes of cross-validation and obtaining detector independent results. Four detector systems were deployed, three by the NCERC team and one from the University of Michigan. The detector systems included a Neutron Multiplicity Array Detector (NoMAD) system (similar to the MC-15), four small volume 0.635 cm (Ø) × 7.59 cm 3 He detectors (ideal for measuring prompt neutron decay constants due to their fast recovery speed), the Rossi Alpha Measurements – Rapid Organic (n, γ) Discrimination Detector (RAM-RODD), and the Organic Scintillator Array (OSCAR). RAM-RODD is an array of eight 5.08 cm (Ø) × 5.08 cm EJ-309 organic scintillator detectors. OSCAR is a University of Michigan system and is an array of twelve 5.08 cm (Ø) × 5.08 cm stilbene detectors. Details of measurements performed with OSCAR will be discussed in a separate talk. The focus of this work is preliminary results obtained by RAM-RODD for the 8 subcritical configurations. Additional details on the measurements and on the setup and deployment of RAM-RODD will be discussed. Preliminary neutron noise analysis results including Rossi-alpha and Feynman-alpha will also be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Rossi-alpha Analysis of CURIE Experiment

Critical assembly measurement and operations are crucial to the development of benchmark data to support research into criticality safety, radiation-detection development, and the overall application of nuclear technologies. Accurate nuclear data are needed for accurate predictive simulations, and validation using critical experiments is an important part of the nuclear data pipeline. The accuracy of nuclear data are improved using more robust and targeted measurements. In particular, the intermediate energy range of uranium is of great interest. LANL has successfully performed the Zeus series of experiments on the Comet assembly to investigate the intermediate energy range for HEU with various moderators. A successor to these experiments is the benchmark for the Critical Unresolved Region Integral Experiment (CURIE), designed to be sensitive to the unresolved resonance region (URR). This experiment is designed using polytetrafluoroethylene, more commonly known as Teflon, moderators. The CURIE experiment was successfully conducted at the National Criticality Experiments Research Center (NCERC). The Rossi-alpha method was used to evaluate the propensity of the CURIE configurations to sustain fission chains by estimating the prompt neutron decay constant α. This work evaluates the α at delayed critical using Rossi-alpha for different Teflon moderator thicknesses in the CURIE experiment. These results will help improve understanding of the CURIE benchmark experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Validation of KENO Delayed Neutron Fraction Capabilities

The delayed neutron fraction, which is necessary for the safe operation of reactors, varies by fissionable material and neutron spectrum. A prompt fission neutron spectrum has been included in the SCALE 6.2 release to account for the removal of delayed neutrons from precursor materials from the neutron balance. This paper describes how experimental measurements from criticality safety benchmarks were used to validate the SCALE calculational procedure for the delayed neutron fraction. Additionally, the effect of nuclear data uncertainty on the KENO calculation of β eff was examined with the SAMPLER sequence.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Preliminary NoMAD Results of the MUSIC Experiment

The Measurement of Uranium Subcritical and Critical (MUSiC) experiment was carried out from December 2020 through April 2021 at the National Criticality Experiments Research Center (NCERC). This measurement campaign featured bare configurations of the Rocky Flats highly-enriched uranium (HEU) shells, with each configuration having different numbers of these shells. The goal of the experiment was to test multiple neutron multiplicity detectors and measurement methods for a large range of neutron multiplication values, to see when the combination of detectors and methods break down as the configurations reach the delayed supercritical window. Adding subcritical integral benchmarks gives additional validation to nuclear data. These benchmarks provide additional parameters against which to validate the data. While critical benchmarks have just a single value, $K_{eff}$ , subcritical benchmarks can be used to infer multiple parameters. As an example, recent subcritical benchmarks utilizing the Hage-Cifarelli formalism have three quantities of interest ($R_{1}$, $R_{2}$, and $M_{L}$). This gives nuclear data evaluators additional data to use when performing their evaluations, and allows for these benchmarks to be useful for additional types of nuclear data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance of the Initial Implementation of the Shift Monte Carlo Code in SCALE 6.3

The Shift Monte Carlo code will be introduced in SCALE 6.3 as an alternative to the KENO V.a, KENO-VI, and Monaco codes. Calculations were performed to establish the performance of Shift for criticality safety analyses within the criticality safety analyses sequence (CSAS) based on models in the Verified, Archived Library of Inputs and Data (VALID). This test suite contains over 600 critical experiment models covering a broad range of fissile materials and neutron energy spectra. The comparisons presented include calculated k eff values and runtime performance for serial calculations and a selection of parallel calculations. Comparisons are presented for multigroup (MG) and continuous-energy (CE) calculations for KENO V.a and KENO-VI models. Results generated with a beta version of SCALE 6.3 indicate excellent agreement in k eff values between KENO and Shift. The largest differences in the average k eff value calculated for the 15 categories of KENO V.a models are 0.00020 ± 0.00011 Δ k for MG calculations and 0.00011 ± 0.00005 Δ k for CE calculations. Similar comparisons in three categories using KENO-VI result in the largest differences for MG calculations: as 0.00004 ± 0.00003 Δ k , and -0.00002 ± 0.00003 Δ k for CE. The preliminary results also indicate that Shift is faster than KENO on a per particle basis, especially for fast spectrum systems. The uncertainty per history is also higher, however, so the Monte Carlo figure of merit is higher for KENO for thermal and intermediate spectrum systems. As expected, Shift generally has better speedup than KENO for parallel calculations, regardless of neutron energy spectrum.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Update of the Nuclear Criticality Slide Rule: Review of the Estimation of the Number of Fissions

IRSN (France), LLNL (USA) and ORNL (USA) began a long-term collaboration effort in 2015 to update the nuclear criticality Slide Rule (https://ncsp.llnl.gov/analytical-methods/criticality-sliderule) for the emergency response to a nuclear criticality accident. The Slide Rule permits the estimation of neutron and gamma dose rates and integrated doses based upon estimated fission yields, as a function of distance from the fission source, and time after criticality accidents for different critical systems. This paper presents the review of the section “estimation of the number of fissions”, named “fission yield” in the Slide Rule document. This estimation is important because the other information provided by the Slide Rule is directly proportional to the number of fissions. The previous models, based on Hansen and Barbry formulae, will be presented with their associated assumptions and limitations. Then, new proposals will be presented with a comparison to past criticality accidents and experimental data. The new formulae, based on the heat energy equation, cover many types of criticality accidents (solution, dry or low-moderated powder, rods/assemblies in water and dry metal) and require limited information in an emergency situation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Update of the Nuclear Criticality Slide Rule Calculations: Plutonium systems – Delayed Fission Gamma

IRSN (France), LLNL (USA) and ORNL (USA) began a long-term collaboration effort in 2015 to update the nuclear criticality Slide Rule for the emergency response to a nuclear criticality accident. The Slide Rule permits the estimation of neutron and gamma dose rates and integrated doses based upon estimated fission yields, as a function of distance from the fission source, and time after criticality accidents for different critical systems. This paper presents results from the fourth phase of the current update of the Slide Rule project, in which delayed fission-product gamma (DFG) dose rates of unreflected plutonium critical systems were compared by several modern 3D radiation transport codes (MCNP, COG, SCALE), using updated flux-to-dose conversion factors. Dose rates are calculated for fissile material at five moderation ratios (H/Pu), at 1 m above the ground as a function of distance (between 30 cm and 1,200 m) from the external surface of the source to the center of the detector, and for periods between 1 s and 1,000 min after the critical instantaneous event. Further efforts have been devoted to the determination of the delayed gamma source, by comparing the time-dependent energy spectra obtained from several methods. Overall, DFG dose rates calculated by each participant led to consistent results. Extra effort is under way to identify the cause of the remaining differences, by comparing precisely the gamma source, and particularly nuclides inventories.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Multigroup Examination of Nickel-Reflected HEU System

Critical configurations of HEU-MET-FAST-003 (HMF-003) from the International Criticality Safety Benchmark Evaluation Project Handbook were modeled for addition into the Verified, Archived Library of Inputs and Data maintained at Oak Ridge National Laboratory. HMF-003 contains models of a highly enriched uranium sphere with a spherical metal reflector of natural uranium, tungsten carbide, or nickel. For these simple models, good agreement is expected between the k eff calculated with continuous-energy (CE) and multigroup (MG) transport. However, using the CSAS5 sequence of the SCALE 6.2.4 package, the 8 in. thick nickel reflector model resulted in a difference of around 1.2 % Δ k . Results presented a clear indication of poor performance for the SCALE 252-group based on ENDF/B-VII.1 cross section library for this model. The bias was investigated over a range of nickel thickness and then compared with other MG libraries available in SCALE 6.2.4. As the nickel thickness increases, the MG k eff deviates from the CE result, confirming a performance issue with the MG calculation. Additionally, the reactions were compared between the two libraries to help determine the cause of k eff bias. Finally, additional MG libraries within SCALE 6.3 and based on ENDF/B-VII.1 and ENDF/B-VIII were reviewed. The 302-group and 1597-group result in significant improvements compared with the 252-group library. Nickel cross sections were modified from ENDF/B-VII.1 to ENDF/B-VIII. For the ENDF/B-VIII library, the deviation between the CE libraries and MG libraries is less pronounced than for ENDF/VII.1, except for the 1597-group. This examination clearly indicates the importance of validating calculations with applicable benchmark experiments and caution when using MG libraries.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Evaluation of Oak Ridge National Laboratory Health Physics Research Reactor Operation Data for Critical Benchmark Creation

The Oak Ridge National Laboratory (ORNL) Health Physics Research Reactor (HPRR) was a research reactor designed and built at ORNL in 1961. The critical assembly used a highly enriched uranium and molybdenum alloy as the fuel and could be operated in steady-state or burst modes. The HPRR has recently been the object of an investigation to create a criticality benchmark. Such benchmarks are very important, as they are used primarily to show the accuracy of newly developed modeling codes and to help experimental validation and reactor licensing. The evaluated experiments considered in this paper were carried out between 1974 and 1986 from various HPRR activities such as steady-state subcritical, steady-state critical, and burst prompt super-critical operations of the reactor for dosimetry, irradiation, or training purposes. By using the HPRR experimental logbook information and the as-built drawings of the critical assembly, a highly detailed model of the HPRR was created with SCALE 6.2.4/KENO-VI, and a first version of a critical benchmark of the HPRR was developed following the International Criticality Safety Benchmark Evaluation Project (ICSBEP) guidelines for thorough description and uncertainty/sensitivity quantification. Unfortunately, in most of the evaluated experiments, the obtained difference between calculated and experimental k eff is around 1,000 pcm, corresponding to a relative error of approximately 1%, beyond the quality standards of the ICSBEP recommending a relative error below 0.1%. Moreover, the derived experimental uncertainty is high, around 4% relative, mainly due to the U-Mo fuel density uncertainty, but also from numerous other factors. For these reasons, the creation of a valuable critical benchmark from HPRR operation data is thus far compromised. In this paper, the different steps of the experiments’ evaluation are summarized, and the reasons for the experimental/calculation discrepancies and potential ways to solve them are explored. This paper also aims to remind us always to exercise considerable care when performing experimental work, and to record all the data possible for potential future uses.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Impact of Increased Latent Generations on Sensitivity Calculations with SCALE

Analyses of cross section sensitivity data from systems with fissile material allow analysts to associate an importance for each material, nuclide, reaction, and neutron energy by simulating real world criticality scenarios. Although criticality safety validation efforts can be guided by the cross-section sensitivity and uncertainty data generated for a particular system, these calculations can often be computationally expensive and sometimes cumbersome without proper guidance. The TSUNAMI suite within the SCALE code package has several methods for generating sensitivity data, including multigroup and continuous energy (CE) capabilities. The release of SCALE 6.3 has three different CE methods for generating cross section sensitivity data: (1) the Iterated Fission Probability (IFP) method with the KENO Monte Carlo transport solver, (2) the IFP method with the Shift Monte Carlo transport solver, and (3) the Contributon-Linked eigenvalue sensitivity/Uncertainty estimation via Tracklength importance CHaracterization (CLUTCH) method with the KENO Monte Carlo transport solver. Although the CLUTCH method has additional parameters for generating sensitivity data files relative to the IFP method, all three methods use latent generations, which are the generations between an event (i.e., fission) and the assessment of importance based on the asymptotic population of progeny neutrons. Increasing the number of latent generations in a calculation leads to increased discrimination of the sensitivity coefficients but at the cost of the increased uncertainty associated with those generated values. Analysts must balance the accuracy of the sensitivity calculations and its uncertainty with the associated computational cost involved in generating the values. This paper discusses the impact of adjusting the latent generation parameter for a range of sensitivity values and how these changes compare with the direct perturbation values obtained from a change of ±0.5% Δ k in both benchmark and safety application models. Two benchmarks from the International Handbook of Evaluated Criticality Safety Benchmark Experiments and the MPC-32 dual purpose canister for spent nuclear fuel are used for analysis.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗