Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Monte Carlo Method”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Deterministic methods for numerical simulation of high-energy runaway electron avalanches

The possibilities of two deterministic methods for describing the kinetics of high-energy runaway electrons (REs) are analyzed as alternatives to stochastic methods requiring unrealistically large computing resources in problems of numerical simulation of electric discharges in dense gases involving REs. One of the methods being developed in recent years is based on multigroup equations for the moments of the electron distribution function, while the second method, which is conventionally used to solve problems in gas discharges, is based on the diffusion-drift equation. The modern method of multigroup equations allows one to calculate the RE energy distribution and the spatial RE distribution along the electric force, which are close to these distributions obtained by the Monte Carlo method if the number N of energy groups is chosen properly. The diffusion-drift equation does not give the energy distribution, but its advantage is the possibility of obtaining spatial RE distributions using small computing resources not only along but also perpendicular to the electric force, which are close to those calculated by the Monte Carlo method. To simulate discharges by the method of multigroup equations, it is necessary to know a priori the number N of groups providing good accuracy, the characteristic RE multiplication time t{sub e}, and the energy runaway threshold {epsilon}{sub th} as functions of the electric-field overvoltage. The diffusion-drift equation requires the specification, along with t{sub e}, of the directed RE velocity and longitudinal and transverse diffusion coefficients calculated by the Monte Carlo method.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fully consistent Eulerian Monte Carlo fields method for solving probability density function transport equations in turbulence modeling

The probability density function (PDF) transport equation method is a sophisticated model for the closure of turbulent mixing and turbulent reactive flows. An efficient solution approach for solving the PDF transport equation has been vital for the method to be widely used in applications. The Eulerian Monte Carlo fields (EMCF) method has been developed to solve the PDF transport equation efficiently for decades. A recent work by Wang et al. revealed a serious issue of the EMCF method for not being fully consistent with the PDF transport equation for which the method is designed to solve. This work advances the state of the art by introducing fully consistent EMCF methods for solving the PDF transport equation. The fully consistent EMCF formulations are derived for two different PDF equation forms. The consistency of the EMCF formulations is mathematically confirmed by examining the derived moment transport equations from the EMCF formulations and from the PDF transport equation. The method of manufactured solutions is employed to further verify the consistency and convergence of the different EMCF formulations numerically. The newly introduced EMCF formulations bring the EMCF method to full consistency with the PDF transport equations for the first time.

42 ENGINEERING↗

Variance Estimation in Monte Carlo Eigenvalue Simulations Using Spectral Analysis Method

The Monte Carlo (MC) method is the 'gold standard' for performing nuclear reactor calculations and criticality safety analyses because of its ability to handle complex geometries and physics. Reactor and criticality safety analyses require solving eigenvalue problems in complex nuclear systems. Once a stationary fission source distribution is obtained in MC simulations, the sample mean of many stationary cycles is calculated. The MC simulation sample mean is typically referred to as a tally. Variance, or standard deviation, of the sample mean/tally is needed to indicate the level of statistical uncertainty in the simulation and to understand the convergence of the sample mean. Current MC codes typically use sample variance to estimate the statistical uncertainty of the simulation and assume that the MC stationary cycles are independent. However, it is known that cycles are correlated, and estimators of the variance that ignore these correlations systematically underestimate the variance. In this paper, we propose a novel method in the Fourier frequency domain to estimate the variance of the sample mean in MC eigenvalue calculations. Results indicate that the proposed estimator can be unbiased compared to the real variance. The proposed estimator requires minimal additional computing effort.

42 ENGINEERING↗

SCALE 6.2 Continuous-energy Tsunami- 3D capabilities - 14566

The TSUNAMI (Tools for Sensitivity and Uncertainty Analysis Methodology Implementation) capabilities within the SCALE code system make use of sensitivity coefficients for an extensive number of criticality safety applications, such as quantifying the data-induced uncertainty in the eigenvalue of critical systems, assessing the neutronic similarity between different systems, quantifying computational biases, and guiding nuclear data adjustment studies. The need to model geometrically complex systems with improved ease of use and fidelity and the desire to extend TSUNAMI analysis to advanced applications have motivated the development of a SCALE 6.2 module for calculating sensitivity coefficients using three-dimensional (3D) continuous-energy (CE) Monte Carlo methods: CE TSUNAMI-3D. This paper provides an overview of the theory, implementation, and capabilities of the CE TSUNAMI-3D sensitivity analysis methods. CE TSUNAMI contains two methods for calculating sensitivity coefficients in eigenvalue sensitivity applications: (1) the Iterated Fission Probability (IFP) method and (2) the Contribution-Linked eigenvalue sensitivity/Uncertainty estimation via Track length importance Characterization (CLUTCH) method. This work also presents the Generalized Adjoint Response in Monte Carlo method (GEAR-MC), a first-of-its-kind approach for calculating adjoint-weighted, generalized response sensitivity coefficients - such as flux responses or reaction rate ratios - in CE Monte Carlo applications. The accuracy and efficiency of the CE TSUNAMI-3D eigenvalue sensitivity methods are assessed from a user perspective in a companion publication, and the accuracy and features of the CE TSUNAMI-3D GEAR-MC methods are detailed in this paper. (authors)

42 ENGINEERING↗

Monte Carlo solution methods in a moment-based scale-bridging algorithm for thermal radiative transfer problems: Comparison with Fleck and Cummings

We have developed a moment-based scale-bridging algorithm for thermal radiative transfer problems. The algorithm takes the form of well-known nonlinear-diffusion acceleration which utilizes a low-order (LO) continuum problem to accelerate the solution of a high-order (HO) kinetic problem. The coupled nonlinear equations that form the LO problem are efficiently solved using a preconditioned Jacobian-free Newton-Krylov method. This work demonstrates the applicability of the scale-bridging algorithm with a Monte Carlo HO solver and reports the computational efficiency of the algorithm in comparison to the well-known Fleck-Cummings algorithm. (authors)

97 MATHEMATICS AND COMPUTING↗

A Review of Best Practices for Monte Carlo Criticality Calculations

Monte Carlo methods have been used to compute k eff and the fundamental mode eigenfunction of critical systems since the 1950s. While such calculations have become routine using standard codes such as MCNP and SCALE/KENO, there still remain 3 concerns that must be addressed to perform calculations correctly: convergence of k eff and the fission distribution, bias in k eff and tally results, and bias in statistics on tally results. This paper provides a review of the fundamental problems inherent in Monte Carlo criticality calculations. To provide guidance to practitioners, suggested best practices for avoiding these problems are discussed and illustrated by examples.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A Wigner Monte Carlo approach to density functional theory

In order to simulate quantum N-body systems, stationary and time-dependent density functional theories rely on the capacity of calculating the single-electron wave-functions of a system from which one obtains the total electron density (Kohn–Sham systems). In this paper, we introduce the use of the Wigner Monte Carlo method in ab-initio calculations. This approach allows time-dependent simulations of chemical systems in the presence of reflective and absorbing boundary conditions. It also enables an intuitive comprehension of chemical systems in terms of the Wigner formalism based on the concept of phase-space. Finally, being based on a Monte Carlo method, it scales very well on parallel machines paving the way towards the time-dependent simulation of very complex molecules. A validation is performed by studying the electron distribution of three different systems, a Lithium atom, a Boron atom and a hydrogenic molecule. For the sake of simplicity, we start from initial conditions not too far from equilibrium and show that the systems reach a stationary regime, as expected (despite no restriction is imposed in the choice of the initial conditions). We also show a good agreement with the standard density functional theory for the hydrogenic molecule. These results demonstrate that the combination of the Wigner Monte Carlo method and Kohn–Sham systems provides a reliable computational tool which could, eventually, be applied to more sophisticated problems.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Analysis of Plane-Parallel Electron Beam Propagation in Different Media by Numerical Simulation Methods

Simulation by the Monte Carlo method is widely used to calculate the character of ionizing radiation interaction with substance. A wide variety of programs based on the given method allows users to choose the most suitable package for solving computational problems. In turn, it is important to know exactly restrictions of numerical systems to avoid gross errors. Results of estimation of the feasibility of application of the program PCLab (Computer Laboratory, version 9.9) for numerical simulation of the electron energy distribution absorbed in beryllium, aluminum, gold, and water for industrial, research, and clinical beams are presented. The data obtained using programs ITS and Geant4 being the most popular software packages for solving the given problems and the program PCLab are presented in the graphic form. A comparison and an analysis of the results obtained demonstrate the feasibility of application of the program PCLab for simulation of the absorbed energy distribution and dose of electrons in various materials for energies in the range 1–20 MeV.

61 RADIATION PROTECTION AND DOSIMETRY↗

Low-Z linac targets for low-MV gold nanoparticle radiation therapy

Purpose: To investigate the potential of low-Z/low-MV (low-Z) linac targets for gold nanoparticle radiotherapy (GNPT) and to determine the microscopic dose enhancement ratio (DER) due to GNP for the alternative beamlines. In addition, to evaluate the degradation of dose enhancement arising from the increased attenuation of x rays and larger skin dose in water for the low-MV beams compared to the standard linac. Methods: Monte Carlo simulations were used to compute dose and DER for various flattening-filter-free beams (2.5, 4, 6.5 MV). Target materials were beryllium, diamond, and tungsten-copper high-Z target. Target thicknesses were selected based on 20%, 60%, 70%, and 80% of the continuous slowing down approximation electron ranges for a given target material and energy. Evaluation of the microscopic DER was carried out for 100 nm GNP including the degradation factors due to beam attenuation. Results: The greatest increase in DER compared to the standard 6.5 MV linac was for a 2.5 MV Be-target (factor of ∼2). Skin dose ranged from ∼10% (Be, 6.5 MV-80%) to ∼85% (Be, 2.5 MV-20%) depending on the target case. Attenuation of 2.5 MV beams at 22 cm was higher by ∼75% compared with the standard beam. Taking into account the attenuation at 22 cm depth, the effective dose enhancement was up to ∼60% above the DER of the high-Z target. For these cases the effective DER ranged between ∼1.6 and 6 compared with the standard linac. Conclusions: Low-Z (2.5 MV) GNPT is possible even after accounting for greater beam attenuation for deep-seated tumors (22 cm) and the increased skin dose. Further, it can lead to significant sparing of normal tissue while simultaneously escalating the dose in the tumor cells.

61 RADIATION PROTECTION AND DOSIMETRY↗

Advanced Capability of Monte Carlo Transport and Depletion Calculation Program SuperMC for Fusion and Fission Applications

Since the advantages of high simulation accuracy and flexible geometry representation, the Monte Carlo methods have been broadly adopted in nuclear design and analysis of nuclear energy systems. However, great challenges exist for the current Monte Carlo methods including the calculation modeling of complex geometries, slow convergence of complex calculation, etc. Super Monte Carlo Simulation Program for Nuclear and Radiation Process (SuperMC), developed by FDS team, is a general purpose, intelligent and multi-functional program for the design and safety evaluation of nuclear systems, which is designed to perform the comprehensive neutronics calculation. The latest version of SuperMC can accomplish the transport calculation of n,{gamma} for criticality and shielding problems, depletion calculation of isotopes, and has been integrated with the functions of automatic modeling, visualization and cloud computing. The latest progress will be introduced in this paper. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Low energy isomers of (H{sub 2}O){sub 25} from a hierarchical method based on Monte Carlo temperature basin paving and molecular tailoring approaches benchmarked by MP2 calculations

We report new global minimum candidate structures for the (H{sub 2}O){sub 25} cluster that are lower in energy than the ones reported previously and correspond to hydrogen bonded networks with 42 hydrogen bonds and an interior, fully coordinated water molecule. These were obtained as a result of a hierarchical approach based on initial Monte Carlo Temperature Basin Paving sampling of the cluster's Potential Energy Surface with the Effective Fragment Potential, subsequent geometry optimization using the Molecular Tailoring Approach with the fragments treated at the second order Møller-Plesset (MP2) perturbation (MTA-MP2) and final refinement of the entire cluster at the MP2 level of theory. The MTA-MP2 optimized cluster geometries, constructed from the fragments, were found to be within <0.5 kcal/mol from the minimum geometries obtained from the MP2 optimization of the entire (H{sub 2}O){sub 25} cluster. In addition, the grafting of the MTA-MP2 energies yields electronic energies that are within <0.3 kcal/mol from the MP2 energies of the entire cluster while preserving their energy rank order. Finally, the MTA-MP2 approach was found to reproduce the MP2 harmonic vibrational frequencies, constructed from the fragments, quite accurately when compared to the MP2 ones of the entire cluster in both the HOH bending and the OH stretching regions of the spectra.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Impurity lattice Monte Carlo for hypernuclei

Abstract We consider the problem of including $$\varLambda $$ Λ hyperons into the ab initio framework of nuclear lattice effective field theory. In order to avoid large sign oscillations in Monte Carlo simulations, we make use of the fact that the number of hyperons is typically small compared to the number of nucleons in the hypernuclei of interest. This allows us to use the impurity lattice Monte Carlo method, where the minority species of fermions in the full nuclear Hamiltonian is integrated out and treated as a worldline in Euclidean projection time. The majority fermions (nucleons) are treated as explicit degrees of freedom, with their mutual interactions described by auxiliary fields. This is the first application of the impurity lattice Monte Carlo method to systems where the majority particles are interacting. Here, we show how the impurity Monte Carlo method can be applied to compute the binding energies of the light hypernuclei. In this exploratory work we use spin-independent nucleon–nucleon and hyperon–nucleon interactions to test the computational power of the method. We find that the computational effort scales approximately linearly in the number of nucleons. The results are very promising for future studies of larger hypernuclear systems using chiral effective field theory and realistic hyperon–nucleon interactions, as well as applications to other quantum many-body systems.

Frame, Dillon↗

Sci-Sat AM: Radiation Dosimetry and Practical Therapy Solutions - 02: Dosimetric effects of gold nanoparticle surface coatings

Introduction: Gold nanoparticles (GNPs) can enhance radiation therapy within a tumour, increasing local energy deposition under irradiation, but experimental evidence suggests the enhancement is not as large as predicted by dose enhancement alone. Many studies neglect to account for surface coatings that are frequently used to optimize GNP uptake and biological distribution. This study uses Monte Carlo methods to investigate the consequences on local dose enhancement due to including these surface coatings. Methods: Using the PENELOPE Monte Carlo code system, GNP irradiation was simulated both with and without surface coatings of polyethylene glycol (PEG) of various molecular weights. Dose was scored to the gold, coating, and surrounding water, and the dosimetric differences between these scenarios were examined. Results: The simulated PEG coating absorbs a large portion of the energy that would otherwise be deposited in the medium. The mean dose to water was reduced by up to 2.5, 3.5, and 4.5% for GNPs of diameters 50, 20, and 10 nm, respectively. This effect was more pronounced for smaller GNPs, thicker coatings, and low photon source energies where the enhancement due to GNPs is the greatest. The molecular weight of the coating material did not have a significant impact on the dose. Conclusions: The inclusion of a coating material in GNP enhanced radiation may reduce the dose enhancement due to the nanoparticles. Both the composition and size of the coating play a role in the level of this reduction and should be considered carefully.

60 APPLIED LIFE SCIENCES↗

Uncertainty Analyses for Localized Tallies in Monte Carlo Eigenvalue Calculations

It is well known that statistical estimates obtained from Monte Carlo criticality simulations can be adversely affected by cycle-to-cycle correlations in the fission source. In addition, there are several other more fundamental issues that may lead to errors in Monte Carlo results. These factors can have a significant impact on the calculated eigenvalue, localized tally means and their associated standard deviations. In fact, modern Monte Carlo computational tools may generate standard deviation estimates that are a factor of five or more lower than the true standard deviation for a particular tally due to the inter-cycle correlations in the fission source. The magnitude of this under-prediction can climb as high as one hundred when combined with an ill-converged fission source or poor sampling techniques. Since Monte Carlo methods are widely used in reactor analysis (as a benchmarking tool) and criticality safety applications, an in-depth understanding of the effects of these issues must be developed in order to support the practical use of Monte Carlo software packages. A rigorous statistical analysis of localized tally results in eigenvalue calculations is presented using the SCALE/KENO-VI and MCNP Monte Carlo codes. The purpose of this analysis is to investigate the under-prediction in the uncertainty and its sensitivity to problem characteristics and calculational parameters, and to provide a comparative study between the two codes with respect to this under-prediction. It is shown herein that adequate source convergence along with proper specification of Monte Carlo parameters can reduce the magnitude of under-prediction in the uncertainty to reasonable levels; below a factor of 2 when inter-cycle correlations in the fission source are not a significant factor. In addition, through the use of a modified sampling procedure, the effects of inter-cycle correlations on both the mean value and standard deviation estimates can be isolated.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A multi-group Monte Carlo core analysis method and its application in SCWR design

Complex geometry and spectrum have been the characteristics of many newly developed nuclear energy systems, so the suitability and precision of the traditional deterministic codes are doubtable while being applied to simulate these systems. On the contrary, the Monte Carlo method has the inherent advantages of dealing with complex geometry and spectrum. The main disadvantage of Monte Carlo method is that it takes long time to get reliable results, so the efficiency is too low for the ordinary core designs. A new Monte Carlo core analysis scheme is developed, aimed to increase the calculation efficiency. It is finished in two steps: Firstly, the assembly level simulation is performed by continuous energy Monte Carlo method, which is suitable for any geometry and spectrum configuration, and the assembly multi-group constants are tallied at the same time; Secondly, the core level calculation is performed by multi-group Monte Carlo method, using the assembly group constants generated in the first step. Compared with the heterogeneous Monte Carlo calculations of the whole core, this two-step scheme is more efficient, and the precision is acceptable for the preliminary analysis of novel nuclear systems. Using this core analysis scheme, a SCWR core was designed based on a new SCWR assembly design. The core output is about 1,100 MWe, and a cycle length of about 550 EFPDs can be achieved with 3-batch refueling pattern. The average and maximum discharge burn-up are about 53.5 and 60.9 MWD/kgU respectively. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗