Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Microscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Transmission-type angle deviation microscopy

We present a new microscopy technique that we call transmission angle deviation microscopy (TADM). It is based on common-path heterodyne interferometry and geometrical optics. An ultrahigh sensitivity surface plasmon resonance (SPR) angular sensor is used to expand dynamic measurement ranges and to improve the axial resolution in three-dimensional optical microscopy. When transmitted light is incident upon a specimen, the beam converges or diverges because of refractive and/or surface height variations. Advantages include high axial resolution ({approx}32 nm), nondestructive and noncontact measurement, and larger measurement ranges ({+-} 80 {mu}m) for a numerical aperture of 0.21in a transparent measurement medium. The technique can be used without conductivity and pretreatment.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Enabling Bipolar Membrane Manufacturing Using Microscopy

Bipolar membranes (BPMs) used for water treatment suffer from interface instabilities, causing premature failure and decreased performance. Recent research has highlighted the impacts of membrane morphology on mechanical behavior and performance. Improved material performance of thin film membranes requires enhanced transport properties coupled with better control of the mechanical characteristics to avoid premature failure of the film. Thus, morphology is a key parameter when developing and evaluating novel membrane materials. Microscopy offers unique advantages for nano-scale characterization of thin film membrane interfaces and morphologies. In this study, the interface junction of BPMs was evaluated using scanning electron microscopy (SEM) and energy dispersive X-ray spectroscopy (EDX). BPMs were fabricated using (1) hot pressing lamination, (2) bench-scale solution casting, and (3) roll-to-roll sequential casting (R2R). Both commercial and in-house fabricated ion exchange membranes were used in the BPMs. The BPMs were comprised of a cation exchange membrane and an anion exchange membrane with a catalyst layer sandwiched in between. Cross sectional SEM and EDX images of the membrane interface junction were compared among the different fabrication techniques and materials. The bench cast catalyst layers were nonuniform compared to the R2R and hot pressed membranes, demonstrating the importance of precise catalyst application conditions. Different thicknesses of the BPMs and individual membrane layers revealed that polymer solution concentration needs to be optimized during manufacturing. This work shows that microscopy can identify key processing parameters that affect BPM interface junction quality at the microscale to enable manufacturing of high performance BPMs.

36 MATERIALS SCIENCE↗

Enabling Roll-to-Roll Manufacturing of Bipolar Membranes Using Microscopy

Bipolar membranes (BPMs) used for water treatment suffer from interface instabilities, causing premature failure and decreased performance. Recent research has highlighted the impacts of membrane morphology on mechanical behavior and performance. Improved material performance of thin film membranes requires enhanced transport properties coupled with better control of the mechanical characteristics to avoid premature failure of the film. Thus, morphology is a key parameter when developing and evaluating novel membrane materials. Microscopy offers unique advantages for nano-scale characterization of thin film membrane interfaces and morphologies. In this study, the interface junction of BPMs was evaluated using scanning electron microscopy (SEM) and energy dispersive X-ray spectroscopy (EDX). BPMs were fabricated using (1) hot pressing lamination, (2) bench-scale solution casting, and (3) roll-to-roll sequential casting (R2R). Both commercial and in-house fabricated ion exchange membranes were used in the BPMs. The BPMs were comprised of a cation exchange membrane and an anion exchange membrane with a catalyst layer sandwiched in between. Cross sectional SEM and EDX images of the membrane interface junction were compared among the different fabrication techniques and materials. The bench cast catalyst layers were nonuniform compared to the R2R and hot pressed membranes, demonstrating the importance of precise catalyst application conditions. Different thicknesses of the BPMs and individual membrane layers revealed that polymer solution concentration needs to be optimized during manufacturing. This work shows that microscopy can identify key processing parameters that affect BPM interface junction quality at the microscale to enable manufacturing of high performance BPMs.

36 MATERIALS SCIENCE↗

Polymer Filler Aging and Failure Studied by Lateral Force Microscopy

In the present work, we study, via force microscopy, the basic physical interactions of a single bead of silica filler with a PDMS matrix both before and after exposure to gamma radiation. Our goal was to confirm our results from last year, and to explore force microscopy as a means of obtaining particle-scale polymer/filler interactions suitable for use as empirical inputs to a computational model consisting of an ensemble of silica beads embedded in a PDMS matrix. Through careful calibration of a conventional atomic force microscope, we obtained both normal and lateral force data that was fitted to yield adhesion, surface shear modulus, and friction of a 1 {micro}m silica bead in contact with PDMS layers of various thickness. Comparison of these terms before and after gamma exposure indicated that initially, radiation exposure lead to softening of the PDMS, but eventually resulted in stiffening. Simultaneously, adhesion between the polymer and silica decreased. This could indicate a serious failure path for filled PDMS exposed to radiation, whereby stiffening of the bulk polymer leads to loss of compressive elastic behavior, while a decrease in polymer filler adhesion results in an increased likelihood of stress failure under load. In addition to further testing of radiation damaged polymers, we also performed FEA modeling of silica beads in a silicone matrix using the shear modulus and adhesion values isolated from the force microscopy experiments as model inputs. The resulting simulation indicated that as a polymer stiffens due to impinging radiation, it also undergoes weakening of adhesion to the filler. The implication is that radiation induces a compound failure mode in filled polymer systems.

36 MATERIALS SCIENCE↗

A versatile enhanced freeze-substitution protocol for volume electron microscopy

Volume electron microscopy, a powerful approach to generate large three-dimensional cell and tissue volumes at electron microscopy resolutions, is rapidly becoming a routine tool for understanding fundamental and applied biological questions. One of the enabling factors for its adoption has been the development of conventional fixation protocols with improved heavy metal staining. However, freeze-substitution with organic solvent-based fixation and staining has not realized the same level of benefit. Here, we report a straightforward approach including osmium tetroxide, acetone and up to 3% water substitution fluid (compatible with traditional or fast freeze-substitution protocols), warm-up and transition from organic solvent to aqueous 2% osmium tetroxide. Once fully hydrated, samples were processed in aqueous based potassium ferrocyanide, thiocarbohydrazide, osmium tetroxide, uranyl acetate and lead acetate before resin infiltration and polymerization. We observed a consistent and substantial increase in heavy metal staining across diverse and difficult-to-fix test organisms and tissue types, including plant tissues ( Hordeum vulgare ), nematode ( Caenorhabditis elegans ) and yeast ( Saccharomyces cerevisiae ). Our approach opens new possibilities to combine the benefits of cryo-preservation with enhanced contrast for volume electron microscopy in diverse organisms.

59 BASIC BIOLOGICAL SCIENCES↗

Super-resolution microscopy reveals protein spatial reorganization in early innate immune responses.

Over the past decade optical approaches were introduced that effectively break the diffraction barrier. Of particular note were introductions of Stimulated Emission/Depletion (STED) microscopy, Photo-Activated Localization Microscopy (PALM), and the closely related Stochastic Optical Reconstruction Microscopy (STORM). STORM represents an attractive method for researchers, as it does not require highly specialized optical setups, can be implemented using commercially available dyes, and is more easily amenable to multicolor imaging. We implemented a simultaneous dual-color, direct-STORM imaging system through the use of an objective-based TIRF microscope and filter-based image splitter. This system allows for excitation and detection of two fluorophors simultaneously, via projection of each fluorophor's signal onto separate regions of a detector. We imaged the sub-resolution organization of the TLR4 receptor, a key mediator of innate immune response, after challenge with lipopolysaccharide (LPS), a bacteria-specific antigen. While distinct forms of LPS have evolved among various bacteria, only some LPS variations (such as that derived from E. coli) typically result in significant cellular immune response. Others (such as from the plague bacteria Y. pestis) do not, despite affinity to TLR4. We will show that challenge with LPS antigens produces a statistically significant increase in TLR4 receptor clusters on the cell membrane, presumably due to recruitment of receptors to lipid rafts. These changes, however, are only detectable below the diffraction limit and are not evident using conventional imaging methods. Furthermore, we will compare the spatiotemporal behavior of TLR4 receptors in response to different LPS chemotypes in order to elucidate possible routes by which pathogens such as Y. pestis are able to circumvent the innate immune system. Finally, we will exploit the dual-color STORM capabilities to simultaneously image LPS and TLR4 receptors in the cellular membrane at resolutions at or below 40nm.

59 BASIC BIOLOGICAL SCIENCES↗

On the use of peak-force tapping atomic force microscopy for quantification of the local elastic modulus in hardened cement paste

A surface of epoxy-impregnated hardened cement paste was investigated using a novel atomic force microscopy (AFM) imaging mode that allows for the quantitative mapping of the local elastic modulus. The analyzed surface was previously prepared using focussed ion beam milling. The same surface was also characterized by electron microscopy and energy-dispersive X-ray spectroscopy. We demonstrate the capability of this quantitative nanomechanical mapping to provide information on the local distribution of the elastic modulus (from about 1 to about 100 GPa) with a spatial resolution in the range of decananometers, that corresponds to that of low-keV back-scattered electron imaging. Despite some surface roughness which affects the measured nanomechanical properties it is shown that topography, adhesion and Young's modulus can be clearly distinguished. The quantitative mapping of the local elastic modulus is able to discriminate between phases in the cement paste microstructure that cannot be distinguished from the corresponding back-scattered electron images.

36 MATERIALS SCIENCE↗

Cryoelectron Microscopy Structure of Purified gamma-Secretase at 12 angstrom Resolution

{gamma}-Secretase, an integral membrane protein complex, catalyzes the intramembrane cleavage of the {beta}-amyloid precursor protein (APP) during the neuronal production of the amyloid {beta}-peptide. As such, the protease has emerged as a key target for developing agents to treat and prevent Alzheimer's disease. Existing biochemical studies conflict on the oligomeric assembly state of the protease complex, and its detailed structure is not known. Here, we report that purified active human {gamma}-secretase in digitonin has a total molecular mass of {approx} 230 kDa when measured by scanning transmission electron microscopy. This result supports a complex that is monomeric for each of the four component proteins. We further report the three-dimensional structure of the {gamma}-secretase complex at 12 {angstrom} resolution as obtained by cryoelectron microscopy and single-particle image reconstruction. The structure reveals several domains on the extracellular side, three solvent-accessible low-density cavities, and a potential substrate-binding surface groove in the transmembrane region of the complex.

59 BASIC BIOLOGICAL SCIENCES↗

Amyloid Structure and Assembly: Insights from Scanning Transmission Electron Microscopy

Amyloid fibrils are filamentous protein aggregates implicated in several common diseases such as Alzheimer's disease and type II diabetes. Similar structures are also the molecular principle of the infectious spongiform encephalopathies such as Creutzfeldt-Jakob disease in humans, scrapie in sheep, and of the so-called yeast prions, inherited non-chromosomal elements found in yeast and fungi. Scanning transmission electron microscopy (STEM) is often used to delineate the assembly mechanism and structural properties of amyloid aggregates. In this review we consider specifically contributions and limitations of STEM for the investigation of amyloid assembly pathways, fibril polymorphisms and structural models of amyloid fibrils. This type of microscopy provides the only method to directly measure the mass-per-length (MPL) of individual filaments. Made on both in vitro assembled and ex vivo samples, STEM mass measurements have illuminated the hierarchical relationships between amyloid fibrils and revealed that polymorphic fibrils and various globular oligomers can assemble simultaneously from a single polypeptide. The MPLs also impose strong constraints on possible packing schemes, assisting in molecular model building when combined with high-resolution methods like solid-state nuclear magnetic resonance (NMR) and electron paramagnetic resonance (EPR).

59 BASIC BIOLOGICAL SCIENCES↗

Microfluidic system for transmission electron microscopy

We present a microfluidic system that maintains liquid flow in a specimen chamber for (scanning) transmission electron microscope ((S)TEM) imaging. The specimen chamber consists of two ultra-thin silicon nitride windows supported by silicon microchips. They are placed in a specimen holder that seals the sample from the vacuum in the electron microscope, and incorporates tubing to and from the sample connected to a syringe pump outside the microscope. Using results obtained from fluorescence microscopy of microspheres flowing through the system, an equation to characterize the liquid flow through the system was calibrated. Gold nanoparticles of diameters of 30 and 100 nm moving in liquid were imaged with a 200 kV STEM. It was concluded that despite strong influences from Brownian motion, and sensitivity to small changes in the depth of the bypass channel, the electron microscopy flow data matched the calculated flow speed within an order of magnitude. The system allows for rapid (within a minute) liquid exchange, which can potentially be used, for example, to investigate the response of specimens, e.g., eukaryotic-, or bacterial cells, to certain stimuli.

99 GENERAL AND MISCELLANEOUS↗

How Precisely Can Individual Molecules Be Analyzed? A Case Study on Locally Quantifying Forces and Energies Using Scanning Probe Microscopy

Recent advances in scanning probe microscopy methodology have enabled the measurement of tip-sample interactions with picometer accuracy in all three spatial dimensions, thereby providing a detailed site-specific and distance-dependent picture of the related properties. This paper explores the degree of detail and accuracy that can be achieved in locally quantifying probe-molecule interaction forces and energies for adsorbed molecules. Toward this end, cobalt phthalocyanine (CoPc), a promising CO 2 reduction catalyst, was studied on Ag(111) as a model system using low-temperature, ultrahigh vacuum noncontact atomic force microscopy. Data were recorded as a function of distance from the surface, from which detailed three-dimensional maps of the molecule's interaction with the tip for normal and lateral forces as well as the tip-molecule interaction potential were constructed. The data were collected with a CO molecule at the tip apex, which enabled a detailed visualization of the atomic structure. Determination of the tip-substrate interaction as a function of distance allowed isolation of the molecule-tip interactions; when analyzing these in terms of a Lennard-Jones-type potential, the atomically resolved equilibrium interaction energies between the CO tethered to the tip and the CoPc molecule could be recovered. Interaction energies peaked at less than 160 meV, indicating a physisorption interaction. As expected, the interaction was weakest at the aromatic hydrogens around the periphery of the molecule and strongest surrounding the metal center. In conclusion, the interaction, however, did not peak directly above the Co atom but rather in pockets surrounding it.

36 MATERIALS SCIENCE↗

Atomic-resolution scanning transmission electron microscopy through 50-nm-thick silicon nitride membranes

Silicon nitride membranes can be used for windows of environmental chambers for in situ electron microscopy. We report that aberration corrected scanning transmission electron microscopy (STEM) achieved atomic resolution on gold nanoparticles placed on both sides of a 50-nm-thick silicon nitride membrane at 200 keV electron beam energy. Spatial frequencies of 1/1.2 A were visible for a beam semi-angle of 26.5 mrad. Imaging though a 100-nm-thick membrane was also tested. The achieved imaging contrast was evaluated using Monte Carlo simulations of the STEM imaging of a sample of with a representative geometry and composition.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Scattering effect on the imaging depth limit in two-photon fluorescence microscopy

A model for the propagation of a focused light beam in a strongly scattering medium is used to analyse various factors that limit the capability of two-photon fluorescence microscopy (TPFM) to image deep sections of optically thick biological specimens. The TPFM imaging depth is shown to be limited by three main factors: (1) beam broadening as a result of multiple small-angle scattering, leading to a loss of submicron lateral resolution; (2) strong near-surface fluorescence at large imaging depths as a result of the increase in average source power in order to compensate for scattering losses; (3) reduction in useful two-photon fluorescence signal level because of the exponential attenuation of the excitation power. The influence of these factors is examined in a small-angle diffusion approximation of radiative transfer theory. The first two of them are shown to set a fundamental TPFM limit, whereas the last is an instrumental limitation and appears to be the most critical to state-of-the-art commercial two-photon laser scanning microscopy systems for the vast majority of fluorophores in current use.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Competing Two-phase Coexistence in Doped Manganites: Direct Observations by in situ Lorentz Electron Microscopy

We examined thin epitaxial films La{sub 5/8-y}Pr{sub y}Ca{sub 3/8}MnO{sub 3} (LPCMO:y=0.275-0.3) in situ by Lorentz transmission electron microscopy (TEM) and other microscopy methods. Clear evidence was obtained for the competing two-phase coexistence of antiferromagnetic charge-ordered (CO) and ferromagnetic (FM) phases that exhibit mesoscale phase separation below the metal-to-insulator transition (MIT) at -164 K. In addition, we observed some regions of mixed CO- and FM-domain contrast attributed earlier to formation of the new CO-FM phase. Using in situ heating/cooling TEM experiments, we interpret this effect as the interfacial wetting phenomenon inherent to the first-order CO-FM phase transition, rather than to the formation of new CO-FM phase. It is evidenced by the partial magnetic melting of CO phase at interfaces with the FM phase, thereby creating charge-disordered spin-glass metastates. For coexisting CO- and FM-domain configurations, we directly refined the relationship between charge-orbital and spin-ordering vectors, consistent with FM moments pinned by (101)-crystal twins in LPCMO films. We also discuss the striking linear dependence observed below MIT for the log-resistance behavior and the CO fraction in LPCMO directly measured by TEM. Such linear dependence does not follow typical percolation equations, suggesting that percolation model needs further revisions for transport description of manganites.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Measuring the Burgers vector of dislocations with dark-field X-ray microscopy

The subsurface dynamics of dislocations are essential to many properties of bulk crystalline materials. However, it is challenging to characterize a bulk crystal by conventional transmission electron microscopy (TEM) due to the limited penetration depth of electrons. A novel X-ray imaging technique – dark-field X-ray microscopy (DFXM) – was developed to image hierarchical dislocation structures in bulk crystals. While today's DFXM can effectively map the line structures of dislocations, it is still challenging to quantify the Burgers vectors, the key characterization governing the dislocation behaviors. Here, we extend the 'invisibility criterion' formalism from the TEM theory to the geometrical-optics model of DFXM and demonstrate the consistency between DFXM and dark-field TEM using multi-diffraction-peak imaging for a single edge dislocation. Due to the practical difficulty of multi-peak DFXM experiments, we further study how the Burgers vector effect is encoded for a single-peak DFXM experiment. Using the geometrical-optics DFXM simulation, we explore the asymmetry of rocking tilt scans at different rolling tilts and develop a new method to characterize the Burgers vector. The conclusions of this study advance our understanding of the use of DFXM in characterizing individual dislocations, enabling the connection from bulk DFXM imaging to dislocation mechanics.

36 MATERIALS SCIENCE↗

Three-Dimensional Single-Molecule Localization Microscopy in Whole-Cell and Tissue Specimens

Super-resolution microscopy techniques are versatile and powerful tools for visualizing organelle structures, interactions, and protein functions in biomedical research. However, whole-cell and tissue specimens challenge the achievable resolution and depth of nanoscopy methods. We focus on three-dimensional single-molecule localization microscopy and review some of the major roadblocks and developing solutions to resolving thick volumes of cells and tissues at the nanoscale in three dimensions. These challenges include background fluorescence, system- and sample-induced aberrations, and information carried by photons, as well as drift correction, volume reconstruction, and photobleaching mitigation. We also highlight examples of innovations that have demonstrated significant breakthroughs in addressing the abovementioned challenges together with their core concepts as well as their trade-offs.

59 BASIC BIOLOGICAL SCIENCES↗

Nanoscale imaging of whole cells using a liquid enclosure and a scanning transmission electron microscopy

Nanoscale imaging techniques are needed to investigate cellular function at the level of individual proteins and to study the interaction of nanomaterials with biological systems. We imaged whole fixed cells in liquid state with a scanning transmission electron microscope (STEM) using a micrometer-sized liquid enclosure with electron transparent windows providing a wet specimen environment. Wet-STEM images were obtained of fixed E. coli bacteria labeled with gold nanoparticles attached to surface membrane proteins. Mammalian cells (COS7) were incubated with gold-tagged epidermal growth factor and fixed. STEM imaging of these cells resulted in a resolution of 3 nm for the gold nanoparticles. The wet-STEM method has several advantages over conventional imaging techniques. Most important is the capability to image whole fixed cells in a wet environment with nanometer resolution, which can be used, e.g., to map individual protein distributions in/on whole cells. The sample preparation is compatible with that used for fluorescent microscopy on fixed cells for experiments involving nanoparticles. Thirdly, the system is rather simple and involves only minimal new equipment in an electron microscopy (EM) laboratory.

59 BASIC BIOLOGICAL SCIENCES↗