Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Microscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Multimodal Atomic Force Microscopy for the Characterization of Metallic Particulates

This study investigates the utility of multimodal, or functional, atomic force microscopy (AFM) for the characterization of individual particles and particle ensembles. In single-particle analyses, AFM imaging modes provided orthogonal insights into mechanical and magnetic properties that are not accessible through conventional electron microscopy. Although the experiments were inherently delicate and time-intensive, with an observed sample loss rate of approximately 30%, these techniques enabled the qualitative differentiation of grain structures and magnetic domains, underscoring the challenges of experimental robustness. For particle ensembles, AFM enabled the extraction of reliable 2D and 3D particle size distributions. However, efforts to chemically differentiate particles based on mechanical property contrasts were limited by scaling effects and the qualitative nature of the data. Overall, multimodal AFM offers valuable complementary information, but its application requires careful consideration of methodological limitations, particularly for sample integrity, calibration, and scalability of mechanical and magnetic measurements. This report is organized to first address the application of AFM to single-particle analysis using various imaging modalities, followed by its potential role in ensemble-level particle screening and differentiation.

36 MATERIALS SCIENCE↗

Understanding Biases in Sample Preparation Techniques for Coupled Scanning Electron Microscopy and MAMA PuO 2 Morphological Analysis

In this project, the scanning electron microscopy (SEM) sampling method used during the statistical design study (SDS) was investigated to determine if any sampling biases were present in the analyzed data. Using standard particle size distribution powders from the National Institute of Standards and Technology (NIST 1984 standard reference material) with the origin wet dispersion method, it was determined that a bias to smaller particles was present. This was supported by theoretical calculations using Stokes’ law to determine the settling rate of spherical particles of roughly the same size and mass as those found in the SDS. Based on the theoretical calculations, it was determined that the settling rate for each of the 76 powder sets in the SDS could be unique based on specific particle shape and mass distributions, making a universal correction factor/formula not applicable. Therefore, priority shifted to developing an improved wet dispersion method that significantly reduced the particle settling rate for all particle size and shapes. This was achieved by replacing the original solvent (isopropyl alcohol) with a heavy liquid (lithium heteropolytungstates), which dramatically slowed the settling rate and allowed for the capture of a suitable homogeneous aliquot. SEM imaging and Morphological Analysis for Material Attribution (MAMA) software analysis were conducted on the NIST standard, and the SEM/MAMA data were compared to data captured by a dynamic image analysis particle size analyzer. The resulting data confirmed that the new wet dispersion method does indeed deliver an improved representative aliquot to the SEM stub. For instance, in the NIST certificate, the average particle size is ~17.1 µm ± 2.2 µm with a normal distribution. The initial wet dispersion method resulted in a drastically reduced average particle size of 6.1 µm in addition to a non-representative heavy bi-modal distribution whereas the improved LST wet dispersion method resulting in an average particle size that was much closer to the NIST certificate (12.7 µm) with a similar normal distribution. Although the improved method was still short of the NIST certificate average, atomic force microscopy analysis determined that the resulting ~20-25% reduction in size was due to particles sinking into the carbon sticky tape used for SEM imaging. It is believed that that this bias can be calibrated in a much more predicable manner than the original settling rate bias. In addition, the matching normal distribution curves between the NIST certificate and the heavy liquid method indicate a much-improved representative aliquot has been sampled and imaged. A surrogate CeO 2 powder was used to reflect PuO 2 more accurately and to aid in implementing radiological controls and shielding. The resulting data sets from the SEM/MAMA method and the particle size analyzer give almost identical average particle sizes and particle distribution statistics. Future work will re-analyze several select runs from the SDS to determine if morphological signatures can be found with the improved sampling method.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SEM/EBSD Characterization of Baffle-Former Bolts Designated for High Energy X-ray Microscopy Studies at the Advanced Photon Source

This report documents the microstructural and surface characterization of two high-fluence baffle-former bolts (BFBs) harvested from a commercial pressurized water reactor (PWR) after nearly four decades of service. These bolts experienced extreme conditions including high neutron fluence, elevated temperatures, corrosive primary water, and sustained mechanical loads, all of which contribute to degradation mechanisms such as irradiation-assisted stress corrosion cracking (IASCC). Using scanning electron microscopy (SEM) and electron backscatter diffraction (EBSD), the study assessed bulk and near-surface microstructures, grain boundary characteristics, and in-service oxide layers. The results revealed significant differences between bolts exposed to 41 dpa and 29 dpa, including differences in recrystallization extent, deformation structures, and oxidation morphology. These findings establish critical baseline data for integration with advanced synchrotron-based high-energy X-ray microscopy (HEXM) and computational crystal plasticity models. Ultimately, the work supports improved mechanistic understanding and predictive capability regarding the long-term performance of reactor core internal components.

Lach, Tim [Oak Ridge National Laboratory (ORNL), O↗

Nanometrology of Biomass for Bioenergy: The Role of Atomic Force Microscopy and Spectroscopy in Plant Cell Characterization

Ethanol production using extracted cellulose from plant cell walls (PCW) is a very promising approach to biofuel production. However, efficient throughput has been hindered by the phenomenon of recalcitrance, leading to high costs for the lignocellulosic conversion. To overcome recalcitrance, it is necessary to understand the chemical and structural properties of the plant biological materials, which have evolved to generate the strong and cohesive features observed in plants. Therefore, tools and methods that allow the investigation of how the different molecular components of PCW are organized and distributed and how this impacts the mechanical properties of the plants are needed but challenging due to the molecular and morphological complexity of PCW. Atomic force microscopy (AFM), capitalizing on the interfacial nanomechanical forces, encompasses a suite of measurement modalities for nondestructive material characterization. Here, we present a review focused on the utilization of AFM for imaging and determination of physical properties of plant-based specimens. The presented review encompasses the AFM derived techniques for topography imaging (AM-AFM), mechanical properties (QFM), and surface/subsurface (MSAFM, HPFM) chemical composition imaging. In particular, the motivation and utility of force microscopy of plant cell walls from the early fundamental investigations to achieve a better understanding of the cell wall architecture, to the recent studies for the sake of advancing the biofuel research are discussed. An example of delignification protocol is described and the changes in morphology, chemical composition and mechanical properties and their correlation at the nanometer scale along the process are illustrated.

09 BIOMASS FUELS↗

High-Resolution Transmission Electron Microscopy Study of a Powder River Basin Coal-Derived Fly Ash

Examination of a fly ash derived from the combustion of a low-S, subbituminous Powder River Basin coal by Scanning Electron Microscopy (SEM) and High-resolution Transmission Electron Microscopy (HRTEM), both supplemented by Energy-dispersive X-ray spectroscopy (EDS), showed that the fly ashes were dominated by amorphous phases, Ca-rich plagioclase feldspars, Mg-rich phases, complex Ca-Mg-Al-Si-Ti-Fe grains, and trace amounts of REE-rich particles. Many of the particles were rimmed by a Ca-S, possibly a sulfate. HRTEM-EDS examination of a REE-rich particle proved it to be a mix of light- and heavy-rare earth minerals mixed with amorphous phases.

58 GEOSCIENCES↗

Quantitative Microscopy Reveals Stepwise Alteration of Chromatin Structure during Herpesvirus Infection

During lytic herpes simplex virus 1 (HSV-1) infection, the expansion of the viral replication compartments leads to an enrichment of the host chromatin in the peripheral nucleoplasm. We have shown previously that HSV-1 infection induces the formation of channels through the compacted peripheral chromatin. Here, we used three-dimensional confocal and expansion microscopy, soft X-ray tomography, electron microscopy, and random walk simulations to analyze the kinetics of host chromatin redistribution and capsid localization relative to their egress site at the nuclear envelope. Our data demonstrated a gradual increase in chromatin marginalization, and the kinetics of chromatin smoothening around the viral replication compartments correlated with their expansion. We also observed a gradual transfer of capsids to the nuclear envelope. Later in the infection, random walk modeling indicated a gradually faster transport of capsids to the nuclear envelope that correlated with an increase in the interchromatin channels in the nuclear periphery. Our study reveals a stepwise and time-dependent mechanism of herpesvirus nuclear egress, in which progeny viral capsids approach the egress sites at the nuclear envelope via interchromatin spaces.

59 BASIC BIOLOGICAL SCIENCES↗

Using Graphene Liquid Cell Transmission Electron Microscopy to Study in Situ Nanocrystal Etching

Graphene liquid cell electron microscopy provides the ability to observe nanoscale chemical transformations and dynamics as the reactions are occurring in liquid environments. This manuscript describes the process for making graphene liquid cells through the example of graphene liquid cell transmission electron microscopy (TEM) experiments of gold nanocrystal etching. The protocol for making graphene liquid cells involves coating gold, holey-carbon TEM grids with chemical vapor deposition graphene and then using those graphene-coated grids to encapsulate liquid between two graphene surfaces. These pockets of liquid, with the nanomaterial of interest, are imaged in the electron microscope to see the dynamics of the nanoscale process, in this case the oxidative etching of gold nanorods. By controlling the electron beam dose rate, which modulates the etching species in the liquid cell, the underlying mechanisms of how atoms are removed from nanocrystals to form different facets and shapes can be better understood. Graphene liquid cell TEM has the advantages of high spatial resolution, compatibility with traditional TEM holders, and low start-up costs for research groups. Current limitations include delicate sample preparation, lack of flow capability, and reliance on electron beam-generated radiolysis products to induce reactions. With further development and control, graphene liquid cell may become a ubiquitous technique in nanomaterials and biology, and is already being used to study mechanisms governing growth, etching, and self-assembly processes of nanomaterials in liquid on the single particle level.

36 MATERIALS SCIENCE↗

Micropuncture of Bowman's Space in Mice Facilitated by 2 Photon Microscopy

Renal micropuncture and renal 2-photon imaging are seminal techniques in renal physiology. However, micropuncture is limited by dependence on conventional microscopy to surface nephron features, and 2-photon studies are limited in that interventions can only be assessed at the organ, rather than the nephron level. In particular, micropuncture studies of the glomeruli of mice have been challenged by the paucity of surface glomeruli in mice. To address this limitation in order to pursue studies of aspirate from Bowman's space in mouse physiologic models, we developed 2-photon glomerular micropuncture. We present a novel surgical preparation that allows lateral access to the kidney while preserving the required vertical imaging column for 2-photon microscopy. Administration of high molecular weight fluorescein isothiocyanate (FITC)- dextran is used to render the renal vasculature and therefore glomeruli visible for 2-photon imaging. A quantum dot-coated pipette is then introduced under stereotactic guidance to a glomerulus selected from the several to many which may be visualized within the imaging window. In this protocol, we provide details of the preparation, materials, and methods necessary to carry out the procedure. This technique facilitates previously-impossible physiologic study of the kidney, including recovery of filtrate from Bowman's space and all segments of the nephron within the imaging depth limit, about 100 µm below the renal capsule. Pressure, charge and flow may all be measured using the introduced pipette. Here, we provide representative data from liquid chromatography/mass spectrometry performed on aspirate from Bowman's space. We expect this technique to have wide applicability in renal physiologic investigation.

Matsushita, Katsuyuki↗

Optimizing Magnetic Force Microscopy Resolution and Sensitivity to Visualize Nanoscale Magnetic Domains

Magnetic force microscopy (MFM) enables mapping local magnetic fields across a sample surface with nanoscale resolution. To perform MFM, an atomic force microscopy (AFM) probe whose tip has been magnetized vertically (i.e., perpendicular to the probe cantilever) is oscillated at a fixed height above the sample surface. The resultant shifts in the oscillation phase or frequency, which are proportional to the magnitude and sign of the vertical magnetic force gradient at each pixel location, are then tracked and mapped. Although the spatial resolution and sensitivity of the technique increases with decreasing lift height above the surface, this seemingly straightforward path to improved MFM images is complicated by considerations such as minimizing topographical artifacts due to shorter range van der Waals forces, increasing the oscillation amplitude to further improve sensitivity, and the presence of surface contaminants (in particular water due to humidity under ambient conditions). In addition, due to the orientation of the probe's magnetic dipole moment, MFM is intrinsically more sensitive to samples with an out-of-plane magnetization vector. Here, high-resolution topographical and magnetic phase images of single and bicomponent nanomagnet artificial spin-ice (ASI) arrays obtained in an inert (argon) atmosphere glovebox with <0.1 ppm O 2 and H 2 O are reported. Further, optimization of lift height and drive amplitude for high resolution and sensitivity while simultaneously avoiding the introduction of topographical artifacts is discussed, and detection of the stray magnetic fields emanating from either end of the nanoscale bar magnets (~250 nm long and <100 nm wide) aligned in the plane of the ASI sample surface is shown. Likewise, using the example of a Ni-Mn-Ga magnetic shape memory alloy (MSMA), MFM is demonstrated in an inert atmosphere with magnetic phase sensitivity capable of resolving a series of adjacent magnetic domains each ~200 nm wide.

47 OTHER INSTRUMENTATION↗

State-of-the-Art Electron Microscopy For Physical Sciences Research

The ability to provide high-resolution information about a variety of materials has made electron microscopy a valuable tool for the physical sciences research community. In recent years, many advanced electron microscopy techniques have been developed to provide access to new classes of materials or provide new types of information about materials. This Methods Collection focuses on a selection of these state-of-the-art techniques, including those that provide access to information about materials in liquids and gases and those that provide new or enhanced information about more conventional solid materials.

47 OTHER INSTRUMENTATION↗

Fluorescence Microscopy Denoising (FMD) dataset

We created a dataset - the Fluorescence Microscopy Denoising (FMD) dataset - that is dedicated to Poisson-Gaussian denoising. The dataset consists of 12,000 real fluorescence microscopy images obtained with commercial confocal, two-photon, and wide-field microscopes and representative biological samples such as BPAE cells, zebrafish, and mouse brain tissues. We use image averaging to effectively obtain ground truth images and 60,000 noisy images with different noise levels.

Image Denoising↗

Ultrastructural pathogenesis of lesions produced by exposure to oxygen difluoride with correlative light microscopy

The lungs of rats exposed to OF2 were examined by light and electron microscopy. The exposures were for 30 to 60 minutes to an average of 4.5 ppm OF2, the minimal lethal dose. Animals were sacrificed after 30 (group 1) and 60 minutes (group 2) exposure and 1 (group 3) and 2 (group 4) hours following 60 minutes exposure. Mild gross changes were observed in groups 3 and 4, but no light microscopic lesions were found. Alterations were noted in all four groups using electron microscopy. These were mostly indicative of fluid change and consisted of blebbing of the endothelial and epithelial layers of the alveolocapillary wall and rarification of the cytoplasm of these cells. The lamellar bodies of the Type II cells showed an increasing and consistent loss of matrix structure and density. These fine structural changes increased in quantity and severity as time of exposure or post-exposure period increased. (Modified author abstract)

Harrison, G.↗

Holographic microscopy studies of emulsions

A holographic microscopy system that records and observes the dynamic properties of separation of dispersed immiscible fluids is described. The holographic construction system and reconstruction system that were used to obtain particle size and distribution information from the holograms are discussed. The holographic microscopy system is used to observed the phase separating processes in immiscible fluids that were isothermally cooled into the two phase region. Nucleation, growth rates, coalescence, and particle motion are successfully demonstrated with this system. Thus a holographic particle sizing system with a resolution of 2 micrometers and a field of view of 100 cu cm was developed that provides the capability of testing the theories of separating immiscible fluids for particle number densities in the range of 10 to 10 to the 7th power particles.

Witherow, W. K.↗

Investigation of wear phenomena by microscopy

The various wear mechanisms involved in the loss of material from metallic and nonmetallic surfaces are discussed. The results presented indicate how various microscopy techniques used in conjunction with other analytical tools can assist in the elucidation of a wear mechanism. Without question, microscopy is the single most important tool for the study of the wear of surfaces, to assess and address inherent mechanisms of the material removal process.

Buckley, D. H.↗

Analytical electron microscopy of Mg-SiO smokes - A comparison with infrared and XRD studies

Analytical electron microscopy conducted for Mg-SiO smokes (experimentally obtained from samples previously characterized by IR spectroscopy) indicates that the microcrystallinity content of unannealed smokes increases with increased annealing for up to 30 hr. The growth of forsterite microcrystallites in the initially nonstoichiometric smokes may give rise to the contemporaneous growth of the SiO polymorph tridymite and MgO; after 4 hr of annealing, these react to form enstatite. It is suggested that XRD analysis and IR spectroscopy should be conducted in conjunction with detailed analytical electron microscopy for the detection of emerging crystallinity in vapor-phase condensates.

Rietmeijer, F. J. M.↗

Direct investigation of subsurface interface electronic structure by ballistic-electron-emission microscopy

A new technique for spectroscopic investigation of subsurface interface electronic structure has been developed. The method, ballistic-electron-emission microscopy (BEEM), is based on scanning tunneling microscopy. BEEM makes possible, for the first time, direct imaging of subsurface interface properties with nanometer spatial resolution. The first application of BEEM to subsurface Schottky-barrier interfaces is reported.

Kaiser, W. J.↗

Scanning Tunneling Microscopy methods for spectroscopic imaging of subsurface interfaces

A new method for spatially-resolved, spectroscopic investigation of subsurface interface structure has been developed. The method, Ballistic Electron Emission Microscopy (BEEM), is based on Scanning Tunneling Microscopy (STM) techniques. BEEM combines STM vacuum tunneling with unique ballistic electron spectroscopy capabilities. BEEM enables, for the first time, direct imaging of subsurface interface electronic properties with nanometer spatial resolution. STM topographic images of surface structure and BEEM images of subsurface properties are obtained simultaneously. BEEM capabilities are demonstrated by investigation of important metal-semiconductor interfaces.

Bell, L. D.↗

A scanning electron microscopy study of the macro-crystalline structure of 2-(2,4-dinitrobenzyl) pyridine

The compound, 2-(2,4-dinitrobenzyl) pyridine, was synthesized in the laboratory; an introductory level electron microscopy study of the macro-crystalline structure was conducted using the scanning electron microscope (SEM). The structure of these crystals was compared with the macrostructure of the crystal of 2-(2,4-dinitrobenzyl) pyridinium bromide, the hydrobromic salt of the compound which was also synthesized in the laboratory. A scanning electron microscopy crystal study was combined with a study of the principle of the electron microscope.

Ware, Jacqueline↗