Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Metering”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

The practical equity implications of advanced metering infrastructure

Reductions in advanced metering costs and the efficiency benefits of dynamic pricing make a compelling case to adopt both, particularly for industrial and commercial facilities. Regulators should seriously consider such policies for residential households as well. Regulators can take meaningful steps to mitigate, if not entirely offset, the possibility that some low-income ratepayers may have higher electricity bills with AM and DP. (author)

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Note: A real-time beam current density meter

We have developed a real-time beam current density meter for charged particle beams. It measures the mean current density by collimating a uniform and large diameter primary beam. The suppression of the secondary electrons and the deflection of the beam were simulated, and it was tested with a 105 keV Ar{sup 7+} ion beam.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a pepper-pot emittance meter for diagnostics of low-energy multiply charged heavy ion beams extracted from an ECR ion source

Several fluorescent materials were tested for use in the imaging screen of a pepper-pot emittance meter that is suitable for investigating the beam dynamics of multiply charged heavy ions extracted from an ECR ion source. SiO{sub 2} (quartz), KBr, Eu-doped CaF{sub 2}, and Tl-doped CsI crystals were first irradiated with 6.52-keV protons to determine the effects of radiation damage on their fluorescence emission properties. For such a low-energy proton beam, only the quartz was found to be a suitable fluorescent material, since the other materials suffered a decay in fluorescence intensity with irradiation time. Subsequently, quartz was irradiated with heavy {sup 12}C{sup 4+}, {sup 16}O{sup 4+}, and {sup 40}Ar{sup 11+} ions, but it was found that the fluorescence intensity decreased too rapidly to measure the emittance of these heavy-ion beams. These results suggest that a different energy loss mechanism occurs for heavier ions and for protons.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Algorithms to automate gap-dependent integral tuning for the 2.8-meter long horizontal field undulator with a dynamic force compensation mechanism

A 2.8-meter long horizontal field prototype undulator with a dynamic force compensation mechanism has been developed and tested at the Advanced Photon Source (APS) at Argonne National Laboratory (Argonne). The magnetic tuning of the undulator integrals has been automated and accomplished by applying magnetic shims. A detailed description of the algorithms and performance is reported.

43 PARTICLE ACCELERATORS↗

Eddy current flow meter model validation with a moving solid rod*

We report that the eddy current flow meter (ECFM) has been used to measure velocities and temperatures of conductive flows, such as liquid metal flows in a nuclear fission reactor. The goal of this paper is to develop a finite element electromagnetic model that can characterize the ECFM sensor performance and validate this finite element model with detailed velocity measurements of a controlled, well-characterized moving conductive solid rod. Both measurements and modeling were performed for various parameters that are important for ECFM performance such as rod velocity, rod material, ECFM sensor coil length, number of sensor coils, applied alternating current (AC) current amplitude, and applied ECFM AC frequency. For all parametric scans, the measurement and modeling agree well in both magnitude and trend. The normalized root-mean-square error between measurement and modeling is less than 10% for all cases. These results suggest that electromagnetic modeling could eventually be used to cost-effectively design future ECFM sensors in arbitrary geometry for more challenging applications such as liquid metal nuclear fission reactors.

47 OTHER INSTRUMENTATION↗

Measurement of a radial flow profile with eddy current flow meters and deep neural networks

Eddy current flow meters (ECFMs) measure flows of conductive fluids. Recent interest in ECFMs has increased due to applications in advanced nuclear reactors. ECFMs are well suited for such applications, as they can provide non-invasive measurements of flow in fluids that are often difficult to measure. Traditionally, ECFMs are operated using an alternating current at a single frequency, limiting ECFMs to measure average fluid velocities, blockages, or voids. Here, we expand the capabilities of ECFMs by measuring the fluid radial velocity profile of liquid mercury. To accomplish this, we made several ECFM sensitivity measurements at a range of frequencies. Different frequencies vary the electromagnetic skin depth of the device. By adjusting frequencies, we probed the fluid velocity at various radial locations and constructed a flow-velocity profile. The relationship between the ECFM measurements and velocity profile is nonlinear and requires solving an inverse problem. Using electromagnetic finite-element simulations to train a deep neural network (DNN), we created a model that provides a stable general relationship between the sensitivity measurements of an ECFM and the fluid velocity profile. Using ECFM measurements of liquid mercury, our DNN model calculates a flow profile that agrees well with computational fluid dynamics (CFD) simulations. This technique has potential to improve flow monitoring for optimization, safe operation of conductive fluid loops, and/or validating complex CFD models.

47 OTHER INSTRUMENTATION↗

A Proposal for a Subcritical Reactivity Meter based on Gandini and Salvatores' point kinetics equations for Multiplying Subcritical Systems

Multiplying Subcritical Systems were for a long time poorly studied and its theoretical description remains with plenty open questions. Great interest on such systems arose partly due to the improvement of hybrid concepts, such as the Accelerator-Driven Systems (ADS). Along with the need for new technologies to be developed, further study and understanding of subcritical systems are essential also in more practical situations, such as in the case of a PWR criticalization in their physical startup tests. Point kinetics equations are fundamental to continuously monitor the reactivity behavior to a possible variation of external sources intensity. In this case, quickly and accurately predicting power transients and reactivity becomes crucial. It is known that conventional Reactivity Meters cannot operate in subcritical levels nor describe the dynamics of multiplying systems in these conditions, by the very structure of the classical kinetic equations. Several theoretical models have been proposed to characterize the kinetics of such systems with special regard to the reactivity, as the one developed by Gandini and Salvatores among others. This work presents a discussion about the derivation of point kinetics equations for subcritical systems and the importance of considering the external source. From the point of view of the Gandini and Salvatores' point kinetics model and based on the experimental results provided by Lee and dos Santos, it was possible to develop an innovative approach. This article proposes an algorithm that describes the subcritical reactivity with external source, contributing to the advancement of studies in the field. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Factorization Machine Learning for Disaggregation of Transmission Load Profiles with High Penetration of Behind-the-Meter Solar

The ever-growing high penetration of ubiquitously distributed energy resources, especially behind-the-meter solar (BTM) generations, has significant impacts on nodal load (i.e., net injection) profiles and consequently caused imperative operational challenges to system operators such as regional transmission organizations (RTOs). Illustrated by real-world nodal data and examples at PJM Interconnection, this paper first discusses the application and necessity of effectively extracting daily nodal load profiles in a non-intrusive manner. More importantly, a novel bi-level architecture, including Factorization Machines (FM) learning procedure has been proposed to effectively disaggregate not only one node but every node in an RTO service territory. Specifically, FM leaning is adopted to capture the interconnections between related features to better utilize the correlation between buses in the same region and between a single bus and the zonal load. The proposed bi-level technique is numerically validated using real-world, minute-level, normalized, and anonymized nodal data at PJM service territory.

behind the meter solar, load disaggregation, load ↗

Distribution Transformer Health Monitoring using Smart Meter Data

The distribution electric grid has become a highly complex and intelligent network with changing load and customer types. This has generated unprecedented challenges and opportunities for utility companies–opportunities especially in the area of asset health/performance management. Moreover, several utilities are increasingly moving from the traditional reactive and time-based asset monitoring approach to a more proactive condition based method. However, this needs to be done in a low-cost and efficient manner. Here, this paper explores how existing sensor infrastructure such as smart meters can be utilized to provide utility operators with more visibility into the health and operation of their assets. The paper focuses primarily on service transformers.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Welcome to the Special Issue on Grid-Edge Computing With Behind-the-Meter Resources [Guest Editorial]

The integration of distributed energy resources (DERs), such as solar photovoltaic systems, as well as other synergistic assets, including electric vehicles, energy storage, and smart appliances, in electric power systems has been dramatically increasing in the past few years. These assets have the capability to provide much-needed flexibility to electric power systems for improved grid reliability, resilience, and economic efficiency; however, most of these resources are located behind the meter (BTM) on customer premises, and their flexibility is not fully used in current grid operations. Grid-edge computing plays an important role in unlocking the great benefits and potential that BTM resources could provide to electric power systems by enhancing visibility and controllability at the grid edge.

behind-the-meter resources↗

Building Energy Systems as Behind-the-Meter Resources for Grid Services: Intelligent load control and transactive control and coordination

To mitigate the impacts of climate change, significant reductions in emissions from all sectors of the economy are needed. The electricity generation sector has embarked on an ambitious plan to include renewable generation as part of its decarbonization efforts, and many cities and states are mandating all-electric buildings. While renewable resources will reduce emissions, they are not dispatchable, they vary temporally, and their generation is uncertain. Under these conditions, traditional approaches to managing grid reliability, where supply follows demand, will not be efficient and may not be cost-effective. Further, there is a more efficient alternative for balancing the supply–demand imbalance and for absorbing variability and uncertainty of renewable energy using distributed energy resources (DERs) as opposed to reserve generation. Because buildings consume more than 75% of total U.S. annual electricity consumption, behind-the-meter (BTM) DERs have a load flexibility of 77 GW of power and 90 GWh of virtual energy storage capacity nationwide (Kalsi, 2017). Therefore, some portion of the supply–demand imbalance can be met by these DERs at a lower cost compared to business-as-usual solutions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Scalable Meter Placement Method for Distribution System State Estimation

This paper studies the optimal meter placement problem for distribution system state estimation given limited measurement resources. We formulate the problem as a mixed integer semi-definite programming that minimizes the worst case estimation errors over a set of operating points. To solve the problem, we first relax the problem as a convex optimization problem. Motivated by the lack of scalability of existing solvers, we next leverage the special structure of the cost function and propose an algorithm based on barrier method that solves the problem with significantly better numerical performance. The proposed method has been validated on the IEEE 13-bus, IEEE 123-bus, and IEEE 8,500-bus feeders.

barrier method↗

Evaluating Synthetic Smart Meter Locations For Communication System Modeling

An important part of good communication models for smart grid applications, particularly when wireless protocols are used, is the location information of the nodes. We’ve developed metrics to assist in evaluating whether a given model with such information is representative of feeders found in the world. These metrics are applied to a set of feeder models with known good location information for the smart meter locations and compared to a set of feeder models with similar location information that is not expected to be representative of real-world feeders. The comparison reveals that the suspect models do not pass statistical tests utilizing the developed metrics, providing initial validation of the analysis technique.

smart meter, feeder model, GridLAB-D↗

A Peer-to-Peer Market-Based Control Strategy for a Smart Residential Community with Behind-the-Meter Distributed Energy Resources

This paper presents a distributed peer-to-peer market control strategy to manage and to enable resource sharing of behind-the-meter distributed energy resources in a residential community. In the proposed strategy, each consumer or prosumer determines the flexibility of their point of connection to the power network such that the obtained flexibility is network-feasible. Based on the feasible flexibility, the consumers and the prosumers trade power among each other at each time instance to fulfill their preferred load requirements while maximizing their payoffs and helping to regulate node voltages inside the community. Because the problem to be solved is non-convex, a distributed particle swarm optimization algorithm is used to coordinate the consumers/prosumers in a fully autonomous manner without any centralized or hierarchical coordination. Numerical simulations performed on a community of 48 homes demonstrate the efficacy of the proposed approach.

behind-the-meter↗

A Hierarchical Control Architecture: Utilization of Behind-the-Meter Appliances with Increased Visibility and Controllability

Optimal operations of distribution systems to enhance reliability and resiliency can be achieved if information with higher fidelity can be accessed from grid premise devices. This paper discusses a hierarchical control architecture that can introduce higher visibility and controllability by utilizing the estimated injection and absorption of different behind-the-meter controllable loads, and DERs, including EVs, within a premise. The acquired information is used to make control decisions for scheduling the premise appliances to reduce energy consumptions. The premise controller can also optimize the consumptions on a day-to-day basis in addition to taking input signals from the utility operators to support grid-service events (e.g., peak shaving). The entire control architecture is designed in a modular and scalable fashion that provides benefits to the utility from the reuse of existing infrastructure while creating opportunities for various grid services to be enabled by the operation of premise controllers.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Reducing Demand Charges and Onsite Generation Variability Using Behind-the-Meter Energy Storage

Electric utilities in the United States are increasingly employing demand charges and/or real-time pricing. This directive is bringing potential opportunities in deploying behindthe-meter energy storage (BMES) systems for various grid functionalities. This study quantifies techno-economic benefits of BMES in reducing demand charge and smoothing load/generation intermittencies, and determines how those benefits vary with onsite distributed photovoltaic. We proposed a two-stage control algorithm, whereby the first stage proactively determines costoptimal BMES configuration for reducing peak-demands and demand charges, and the second stage adaptively compensates intermittent generations and short load spikes that may otherwise increase the demand charges. The performance of the proposed algorithm is evaluated through a 24 hours time sweep simulation performed using data from smart microgrid testbed at Idaho National Laboratory (INL). The simulation results demonstrated that this research provides a simple but effective solution for peak shaving, demand charge reductions, and smoothing onsite PV variability.

25 ENERGY STORAGE↗

Deep Factorization Machine Learning for Disaggregation of Transmission Load Profiles with High Penetration of Behind-The-Meter Solar

The ever-growing integration of distributed energy resources (DERs), especially behind-the-meter (BTM) solar generations, poses imperative operational challenges to system operators such as regional transmission organizations (RTOs). It is important for RTOs to effectively and accurately extract actual load profiles at the transmission level for a single node with significant BTM solar injection. This paper first illustrates the necessity of disaggregating the daily actual load profile of a single node. Furthermore, by segmenting nodes with selected timeseries features, nodes with significant BTM solar generation are identified. Lastly, a bi-level framework is proposed, comprising reference node disaggregation and DeepFM nodal disaggregation, aimed at disaggregating the nodal load profiles from which system operators require more information. By adopting a hybrid Deep Factorization Machine (DeepFM) model, the model achieve accurate results by extracting both linear and nonlinear relations between nodes in the same region and the zonal load and nodal load profile. To overcome the lack of ground truth, this paper segments the load profile into daytime, nighttime, and zero-crossing points and utilizes the latter two for evaluation purposes. The proposed disaggregation procedure is validated using real world, minute-level, normalized, and anonymized nodal data in the PJM service territory.

42 ENGINEERING↗