Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MCNPX”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

First Industrial Tests of a Drum Monitor Matrix Correction for the Fissile Mass Measurement in Large Volume Historic Metallic Residues with the Differential Die-away Technique

The fissile mass in radioactive waste drums filled with compacted metallic residues (spent fuel hulls and nozzles) produced at AREVA La Hague reprocessing plant is measured by neutron interrogation with the Differential Die-away measurement Technique (DDT. In the next years, old hulls and nozzles mixed with Ion-Exchange Resins will be measured. The ion-exchange resins increase neutron moderation in the matrix, compared to the waste measured in the current process. In this context, the Nuclear Measurement Laboratory (NML) of CEA Cadarache has studied a matrix effect correction method, based on a drum monitor ({sup 3}He proportional counter inside the measurement cavity). A previous study performed with the NML R and D measurement cell PROMETHEE 6 has shown the feasibility of method, and the capability of MCNP simulations to correctly reproduce experimental data and to assess the performances of the proposed correction. A next step of the study has focused on the performance assessment of the method on the industrial station using numerical simulation. A correlation between the prompt calibration coefficient of the {sup 239}Pu signal and the drum monitor signal was established using the MCNPX computer code and a fractional factorial experimental design composed of matrix parameters representative of the variation range of historical waste. Calculations have showed that the method allows the assay of the fissile mass with an uncertainty within a factor of 2, while the matrix effect without correction ranges on 2 decades. In this paper, we present and discuss the first experimental tests on the industrial ACC measurement system. A calculation vs. experiment benchmark has been achieved by performing dedicated calibration measurement with a representative drum and {sup 235}U samples. The preliminary comparison between calculation and experiment shows a satisfactory agreement for the drum monitor. The final objective of this work is to confirm the reliability of the modeling approach and the industrial feasibility of the method, which will be implemented on the industrial station for the measurement of historical wastes. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Overview on Shielding Analyses for the VENUS Instrument at SNS

VENUS, a world‐class versatile neutron imaging instrument, is under construction and is expected to be completed and ready to start commissioning in 2023. The range of cold to epithermal neutrons at SNS will give users of VENUS access to novel imaging methods, as well as to significantly improved existing methods. The instrument is being built on beam line 10 at Spallation Neutron Source (SNS) First Target Station (FTS) facing a decoupled poisoned hydrogen moderator. Instrument design, which includes optics, Front-End components and instrument enclosure components and shape started over 10 years ago and during this time had significant changes. All changes were supported by neutronics analyses to provide adequate shielding for both Front-End and instrument enclosure.Final optics design will provide the field of view (FOV) at the detector position (where the image is formed) to be as high as 0.20 by 0.20 m. Both the beam, which contains a large fraction of high-energy neutrons, and the desire for a large footprint on the detector are challenges for shielding design and budget, because the driving cost for the instrument is the beam line and enclosure shielding. For cost reason VENUS baseline design is optimized with respect to both the instrument cave footprint and its wall thickness, and Front-End shielding is tailored along the beam. Analyses are performed with the Monte Carlo particle transport code MCNPX version 2.7.0 to make choices on materials, thicknesses and configurations of the shielding. Numerous calculations are performed to meet space and coast constrain and to satisfy instrument physics needs and to comply with radiation protection requirements.

Gallmeier, Franz X.↗

Passive Safety Feature of KIPT Neutron Source Facility

Argonne National Laboratory (ANL) of the United States and Kharkov Institute of Physics and Technology (KIPT) of Ukraine have cooperated on the development, design, and construction of a neutron source facility. The facility was constructed at Kharkov, Ukraine and its commissioning process is underway. The facility has an electron accelerator driven subcritical assembly. The electron beam power is 100 kW using 100 MeV electrons. Tungsten or natural uranium is the target material for generating neutrons driving the subcritical assembly. The subcritical assembly is composed of WWR-M2 Russian fuel assemblies with U-235 enrichment of 19.7 wt%, surrounded by beryllium reflector assembles and graphite blocks. The water coolant operates at room temperature during normal operation, when the facility is operating at full power using 100-KW electron beam power. The passive safety features of the facility are discussed in in this study. Monte Carlo computer code MCNPX was utilized in the analyses with ENDF/BVII.0 nuclear data libraries. Negative reactivity temperature feedback was consistently observed, which is important for the facility safety performance. Due to the design of WWR-M2 fuel assemblies, slight temperature increase and the corresponding density decrease in the water coolant would cause relatively large reactivity drop, which offset the reactivity gain by mistakenly loading an additional fuel assembly. The increase of fuel temperature also causes sufficiently large reactivity decrease. This enhances the facility safety performance because fuel temperature increase provides prompt negative reactivity feedback. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Computational Study of 15 MeV Linac Radiation Doses at the UNLV Accelerator Facility

Linear electron accelerators (linacs) are used to generate Bremsstrahlung photons through the interaction of an electron beam with a heavy metal target. These Bremsstrahlung photons with endpoint energy equal to that of the impinging electron beam are typically collimated into a desired beam shape (fan or cone beams). At electron energies larger than 10 MeV, the interaction of the newly produced photons with the linac component materials leads to the production of neutrons. These neutrons are often undesired and pollute the collimated photon beam while increasing the dose rates at the facility due to the linac operation. MCNPX 2.7.0 code was used to investigate the production of neutrons due to the normal operation of a 15 MeV linac. Dose rates within the UNLV accelerator facility were calculated for both photons and neutrons. Furthermore, the irradiation of several materials using the K15 linac was modeled; the resulting neutron fluxes and dose rates were determined. (authors)

43 PARTICLE ACCELERATORS↗

Neutron and Gamma Correlations using CGM in MCNP 6.2.0

The general-purpose Monte Carlo radiation-transport code MCNP6{sup TM} came from the integration of MCNP5{sup TM} and MCNPX{sup TM}. The most recent release of MCNP, version 6.2.0, is scheduled for release in early 2017, which includes a variety of bug fixes and new features to the code. MCNP traditionally models nuclear reactions using Monte Carlo sampling techniques on measured and modeled cross-sectional data contained within ACE (A Compact Evaluated Nuclear Data File) libraries. In addition to reaction cross-sections, ACE libraries contain information relating to the production of secondary particles, such as secondary neutrons and photons. For example, an incident neutron on a nucleus can produce a nuclear reaction in the form (n, M{sub n}n'), where n is the incident neutron and M{sub n} is the number of secondary neutrons n' produced. Using this notation, different reactions can be described based on their neutron multiplicity, such as neutron capture (M{sub n} = 0), elastic and inelastic scattering (M{sub n} = 1), and reactions with multiple secondary neutrons (M{sub n} > 1). Accounting for secondary γ-rays emitted from the residual nuclei, this reaction can further be generalized as n, Mnn'M to describe a reaction producing M{sub n} neutrons and M -rays. These values M{sub n} and M are referred to as the neutron and multiplicities, respectively. ACE libraries contain the cross-sectional data for each reaction, and their corresponding statistically averaged multiplicities for neutrons and photons, M-bar{sub n} and M-bar{sub γ}. However, there are several limitations to reaction sampling using ACE libraries. First, the data contained within ACE libraries is limited by the accuracy of the model and/or experiment, which out of necessity can greatly simplify the true physics behind a reaction. For example, the value M{sub γ} in a (n, M{sub n}n'M{sub γ}γ) reaction is determined by the statistically averaged multiplicity M-bar{sub γ} instead of a distribution. Consequently, MCNP, unable to produce a continuous distribution, will utilizes a binary sampling around M-bar{sub γ}. While this sampling method provides a statistically average M{sub γ} over a large simulation, it is an inaccurate representation of an individual reaction and its corresponding secondary particles. Secondary neutrons are affected in a similar manner, such that different kinds of secondary neutrons can be sampled from the same interaction (eg., an inelastic neutron with an [n, 2n] neutron). Lastly, the random sampling technique for secondary particles remains completely independent of the sampled reaction, eliminating the ability to correlate secondary particles for a given reaction. To supplement these data libraries, additional codes and models describing certain nuclear reactions are employed. These codes can fill in the information missing from ACE, provide a better model to the true physics distribution, and can provide true correlated secondary particles, which has many useful applications in research and industry.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Shielding design for the LANSCE/WNR neutron flight paths - 25334

The shielding surrounding the spallation target and the neutron flight paths at the Los Alamos Neutron Science Center Weapons Neutron Research facility is simulated using a detailed MCNPX Monte Carlo model to determine neutron and γ-ray backgrounds in the experimental areas. In some cases the shielding needs to be modified depending on the requirements of planned experiments. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Rossi and Feynman-alpha formulas including prompt neutron decay and detector die away time constants - 25396

A simple Rossi-alpha formula and the corresponding Feynman-alpha formula have been derived that take into account two time constants; one characterizing the prompt neutron decay in the fissile source domain and the other the detector die-away time. The derivation of the formula is an extension of the classic heuristic method. A test problem is defined and simulated using the Monte Carlo MCNPX code in order to illustrate the applicability of the formulas. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Activation analysis of the concrete in the Fleurus cyclotron facility - 25604

The purpose of this paper is to discuss the approach and the results of a recent activation analysis concerning a cyclotron facility located in Fleurus, Belgium, where isotopes of medical applications were produced by irradiating either solid (Tl) or gaseous targets (Xe) with 20-30 MeV proton beams. This paper discusses the choice of the intra-nuclear cascade model implemented in MCNP/X to correctly simulate the spallation reactions of the protons in the target, since no nuclear data are available for the isotopes of interest. TENDL nuclear data library, which is based on the models of the nuclear code system TALYS, plays a key role in the selection of the model. The neutron flux distribution throughout the installation and the activation rates in the concrete walls are then calculated with the help of a comprehensive MCNPX model of the facility. The estimated activities are in good agreement with the measurements taken in 2017 in the frame of the ongoing decommissioning of this facility. (authors)

43 PARTICLE ACCELERATORS↗

An MCNP6 Version of the Visual Editor - Paper 2

The Visual Editor is a graphical user interface for working with the MCNP computer code developed at Los Alamos National Laboratory. It consists of a graphical user interface written in C++ that is linked directory to the MCNP Fortran code. Work on the original Visual Editor started in 1992 and was first published in 1993. The original version of the Visual Editor was created on Unix/Linux operating systems and was linked to the MCNP computer code. The Visual Editor was adapted to the Windows operating system in 1999. In 2008 the Visual Editor was adapted to work with the MCNPX computer code. This paper discusses the latest upgrade of the Visual Editor to be compatible with the MCNP6 computer code. Two graphical user interfaces have been created, the Visual MCNP6 Plotter and the Visual MCNP6 Editor. The Visual MCNP6 Plotter includes all of the standard plotting features available in the default MCNP6 plotting package including geometry plotting, tally plotting, cross section plotting, mesh tally plotting and weight window mesh plotting. The Visual MNCP6 Editor has additional capabilities to allow for the creation of MCNP input files with graphical tools. The Visual MCNP6 Editor allows user to create and modify the input file within the Editor. Modifications are not allowed in the Visual MCNP6 Plotter. Both graphical user interfaces allow for advanced plotting features including 3D geometry plots and particle track plotting. Complete details on these tools along with their current status can be found at the Visual Editor website (www.mcnpvised.com). (author)

61 RADIATION PROTECTION AND DOSIMETRY↗

Comparing Measured (a,n) Thick Target Yields to MCNP6 using TENDL 2012 Libraries - Paper 31

MCNP6, due to the heritage of MCNPX, has always possessed the capability to transport the light ions, such as alpha particles. Two types of competing physics take place during the particle transport: atomic and nuclear physics. Charged particles lose energy to media due to Coulombic interactions. MCNP6 models Coulombic interactions through the use of the continuous slowing down approximation. Stopping powers are calculated at a variety of energies using the Bethe-Bloch formula with Sternheimer and Peierls density effect correction. For energies less than 1.31 MeV/AMU, a low-energy SPAR model is used. When the energy of the particle is high enough, there is a transition from nuclear interactions to nucleon interactions. MCNP6 possess various physics models to account for these types of intra-nuclear cascades. These models are less accurate at low energies. Even though MCNP6 will transport these light ions to low energies (i.e. less than 20 MeV), most of the available model physics in MCNP6, for nuclear interactions, has a suggested minimum energy of ∼20-200 MeV. The result of the poorer prediction at low energies causes important light ion events, such as F-19(a,n)Na-22 from U-234 decay in UF{sub 6}, to produce orders of magnitude fewer neutrons in MCNP6 than should be emitted. As with neutrons, ACE (A Compact ENDF) formatted light ion libraries have been developed from several different evaluations. These libraries possess better physics at low energies where the physics models break down. The TENDL 2012 evaluations possess alpha transport libraries, in ACE format, such that they can easily be used with codes like MCNP6 that read ACE formatted cross sections. As a result, a capability was developed for MCNP6 to read and implement these library cross sections when the light ion reached energies below the library upper energy cutoff. Perfectly modelling an experiment for benchmark comparisons to a code calculation can be tricky. For complex setups, systematic error is always possible; and usually a hefty uncertainty analysis is required to quantify just the geometry setup and material combination choices. For an (a,n) interaction, a thick target yield is defined as the amount of neutrons emitted given that the alpha ranges out in the material. For alpha transport at low energy <10 MeV, in reasonably dense materials (>1-2 g/cc), with a material dimension length larger than a few hundred microns, alpha particles will tend to completely stop and range out in the material. For Li, Be, B, C, N, O, F, Na, Mg and Al thick target yields exist in 200 keV intervals from 1 to 9.8 MeV (most of the elements do have (a,n) thresholds above 1 MeV). Because modelling a thick target yield in MCNP6 is much easier than attempting to account for the complexity of systematic error from a full out experiment, we present here comparisons of (a,n) thick target yields to those calculated in MCNP6 using the TENDL 2012 alpha library evaluations.

61 RADIATION PROTECTION AND DOSIMETRY↗

Testing the Delayed Gamma Capability in MCNP6 - Paper 86

The mission of the Domestic Nuclear Detection Office (DNDO) is to quickly and reliably detect unauthorized attempts to import or transport special nuclear material (SNM) for use against the United States. Developing detection equipment to meet this objective requires accurate simulation of both the detectable signature and detection mechanism. MCNP6 is capable of transporting the various types of radiation encountered in these scenarios; however, the accuracy of MCNP6 must be quantified such that we can be confident in the results of the simulations. Delayed gamma transport is one important component of these detection scenarios. Delayed gamma transport is defined as the combination of gamma emission from radioactive and subsequent transport through matter. MCNP always possessed the ability to emit delayed neutrons from fission; however, these delayed neutron spectra and intensity were functional fits and not directly sampled from the created fission products. Furthermore, there existed no method to emit the decay photons from radioactive fission products (or any radioactive nucleus) A delayed particle capability was initially added to MCNPX 2.6.A in 2005 to sample the radioactive fission product parents and emit decay particles resulting from the decay chain. At the point of capture, a residual nucleus is created and decayed using the CINDER90 depletion code. MCNP only sends CINDER90 a residual radioactive nucleus and not a flux (i.e. capture rate). As a result, the Bateman equations for the solution are coupled first order differential equations with constant coefficients. Theoretically, these equations could be solved analytically; however, CINDER90 employs a numerical Markov linear chain scheme to solve these equations. This paper addresses a more simplified approach to benchmarking in order to best assess: (1) whether or not deficiencies exist in the current methodology for certain types of decay chains; and (2) paths forward for improving the delayed particle emission capability. We utilize closed form analytic solutions to the granddaughter equations for particular sets of isotope systems to compare the accuracy of the delayed gamma capability in MCNP6. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Towards application of a neutron cross-section uncertainty propagation capability in the criticality safety methodology - 14434

At the Paul Scherrer Institute (PSI) the methodology for criticality safety evaluations (CSE) used for Swiss applications is focused, following common practice, on establishing an upper subcriticality limit (USL) for the effective neutron multiplication factor (k{sub eff}), based on a statistical evaluation of the obtained validation results in terms of the calculated-to-benchmark k{sub eff} values. Recently, a new computational tool referred to as NUSS (Nuclear data Uncertainty Stochastic Sampling) was developed in order to propagate neutron-nuclear data (ND) uncertainties in calculations with Monte Carlo transport codes in combination with general-purpose ND libraries in ACE format. Thereby, this tool should now allow for a quantification of ND data uncertainties in CSE and to introduce these into the CSE criteria definition. This paper concerns an application of the NUSS methodology for criticality validation studies. Calculated k{sub eff} uncertainty estimations were obtained for the current PSI validation suite including in total 149 critical benchmark configurations for which in-house MCNP(X) models were developed, covering both uranium and mixed uranium-plutonium oxide fuels. The MCNPX-2.7.0 code was used together with the ENDF/B-VII.1 ND library while the ND variance-covariance matrixes (VCM) were taken from both SCALE-6.0 44-group libraries and also from ENDF/B-VII.1 files. Based on the newly obtained information on the uncertainties, a re-assessment of the lower tolerance bound (LTB) for k{sub eff} using the total uncertainties as weighting factors is proposed as means for the present PSI CSE methodology upgrade and some possible directions of further methodology enhancements are discussed next. (authors)

42 ENGINEERING↗

Improved Moderator Performance Calculations at SNS

The Spallation Neutron Source (SNS) at Oak Ridge National Laboratory reached a nominal operating power of 1 MW in September, 2009. Even at ~2/3 of its designed capacity, SNS already becomes the brightest pulsed neutron source in the world, and a premier facility for material and life science research. To provide accurate target performance estimation and to meet future development needs, we had developed an as-built model for the operating target system of SNS. Based on this asbuilt model, the moderator performance at SNS was recalculated taking advantage of the improved physics and tallying method in the Monte Carlo simulation code, MCNPX, and most recent scattering kernels. The neutron flux intensity spectra, emission time distributions of neutron pulses and moderator brightness profiles regarding the SNS moderator performance are presented and discussed. Compared to the previous results, the current calculations show ~10-20% lower in flux with improved emission time distributions of neutron pulses. The difference between the two data sets is analyzed, as well as other factors impacting the moderator performance at SNS. The current calculation results will serve as source terms for the instrument performance simulations at SNS.

Lu, Wei↗

Can Handheld Plastic Detectors Do Both Gamma and Neutron Isotopic Identification with Directional Source Location?

This paper demonstrates, through MCNPX simulations, that a compact hexagonal array of detectors can be utilized to do both gamma isotopic identification (ID) along with neutron identification while simultaneously finding the direction of the source relative to the detector array. The detector array itself is composed of seven borated polyvinyl toluene (PVT) hexagonal light pipes approximately 4 inches long and with a 1.25 inch face-to-face thickness assembled in a tight configuration. The gamma ID capability is realized through judicious windowing algorithms as is the neutron spectral unfolding. By having multiple detectors in different relative positions, directional determination of the source can be realized. By further adding multiplicity counters to the neutron counts, fission events can be measured.

61 RADIATION PROTECTION AND DOSIMETRY↗

Absolute Calibration of Image Plate for electrons at energy between 100 keV and 4 MeV

The authors measured the absolute response of image plate (Fuji BAS SR2040) for electrons at energies between 100 keV to 4 MeV using an electron spectrometer. The electron source was produced from a short pulse laser irradiated on the solid density targets. This paper presents the calibration results of image plate Photon Stimulated Luminescence PSL per electrons at this energy range. The Monte Carlo radiation transport code MCNPX results are also presented for three representative incident angles onto the image plates and corresponding electron energies depositions at these angles. These provide a complete set of tools that allows extraction of the absolute calibration to other spectrometer setting at this electron energy range.

42 ENGINEERING↗

Personal dose equivalent conversion coefficients for neutron fluence over the energy range of 20 to 250 MeV

Monte Carlo simulations were performed to extend existing neutron personal dose equivalent fluence-to-dose conversion coefficients to an energy of 250 MeV. Presently, conversion coefficients, H(p,slab)(10,alpha)/Phi, are given by ICRP-74 and ICRU-57 for a range of angles of radiation incidence (alpha = 0, 15, 30, 45, 60 and 75 degrees ) in the energy range from thermal to 20 MeV. Standard practice has been to base operational dose quantity calculations <20 MeV on the kerma approximation, which assumes that charged particle secondaries are locally deposited, or at least that charged particle equilibrium exists within the tally cell volume. However, with increasing neutron energy the kerma approximation may no longer be valid for some energetic secondaries such as protons. The Los Alamos Monte Carlo radiation transport code MCNPX was used for all absorbed dose calculations. Transport models and collision-based energy deposition tallies were used for neutron energies >20 MeV. Both light and heavy ions (HIs) (carbon, nitrogen and oxygen recoil nuclei) were transported down to a lower energy limit (1 keV for light ions and 5 MeV for HIs). Track energy below the limit was assumed to be locally deposited. For neutron tracks <20 MeV, kerma factors were used to obtain absorbed dose. Results are presented for a discrete set of angles of incidence on an ICRU tissue slab phantom.

61 RADIATION PROTECTION AND DOSIMETRY↗

A Monte Carlo based spent fuel analysis safeguards strategy assessment

Safeguarding nuclear material involves the detection of diversions of significant quantities of nuclear materials, and the deterrence of such diversions by the risk of early detection. There are a variety of motivations for quantifying plutonium in spent fuel assemblies by means of nondestructive assay (NDA) including the following: strengthening the capabilities of the International Atomic Energy Agencies ability to safeguards nuclear facilities, shipper/receiver difference, input accountability at reprocessing facilities and burnup credit at repositories. Many NDA techniques exist for measuring signatures from spent fuel; however, no single NDA technique can, in isolation, quantify elemental plutonium and other actinides of interest in spent fuel. A study has been undertaken to determine the best integrated combination of cost effective techniques for quantifying plutonium mass in spent fuel for nuclear safeguards. A standardized assessment process was developed to compare the effective merits and faults of 12 different detection techniques in order to integrate a few techniques and to down-select among the techniques in preparation for experiments. The process involves generating a basis burnup/enrichment/cooling time dependent spent fuel assembly library, creating diversion scenarios, developing detector models and quantifying the capability of each NDA technique. Because hundreds of input and output files must be managed in the couplings of data transitions for the different facets of the assessment process, a graphical user interface (GUI) was development that automates the process. This GUI allows users to visually create diversion scenarios with varied replacement materials, and generate a MCNPX fixed source detector assessment input file. The end result of the assembly library assessment is to select a set of common source terms and diversion scenarios for quantifying the capability of each of the 12 NDA techniques. We present here the generalized assessment process, the techniques employed to automate the coupled facets of the assessment process, and the standard burnup/enrichment/cooling time dependent spent fuel assembly library. We also clearly define the diversion scenarios that will be analyzed during the standardized assessments. Though this study is currently limited to generic PWR assemblies, it is expected that the results of the assessment will yield an adequate spent fuel analysis strategy knowledge that will help the down-select process for other reactor types.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A Study of 3He detectors for Active Interrogation

3He proportional counters have long been used as neutron detectors for both passive and active detection of Special Nuclear Material (SNM). The optimal configuration of these detectors as far as gas pressure, amount of moderating material, and size are concerned is highly dependent on what neutron signatures are being used to detect and identify SNM. We present here a parametric study of the neutron capture response of 3He detectors, based on Monte Carlo simulations using the MCNPX radiation transport code. The neutron capture response of the detectors has been modeled as a function of time after an incident neutron pulse.

3He↗