Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MAGNETIC RESONANCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Prospective Clinical Implementation of a Novel Magnetic Resonance Tracking Device for Real-Time Brachytherapy Catheter Positioning

Purpose: We designed and built dedicated active magnetic resonance (MR)-tracked (MRTR) stylets. We explored the role of MRTR in a prospective clinical trial. Methods and Materials: Eleven gynecologic cancer patients underwent MRTR to rapidly optimize interstitial catheter placement. MRTR catheter tip location and orientation were computed and overlaid on images displayed on in-room monitors at rates of 6 to 16 frames per second. Three modes of actively tracked navigation were analyzed: coarse navigation to the approximate region around the tumor; fine-tuning, bringing the stylets to the desired location; and pullback, with MRTR stylets rapidly withdrawn from within the catheters, providing catheter trajectories for radiation treatment planning (RTP). Catheters with conventional stylets were inserted, forming baseline locations. MRTR stylets were substituted, and catheter navigation was performed by a clinician working inside the MRI bore, using monitor feedback. Results: Coarse navigation allowed repositioning of the MRTR catheters tips by 16 mm (mean), relative to baseline, in 14 ± 5 s/catheter (mean ± standard deviation [SD]). The fine-tuning mode repositioned the catheter tips by a further 12 mm, in 24 ± 17 s/catheter. Pullback mode provided catheter trajectories with RTP point resolution of ∼1.5 mm, in 1 to 9 s/catheter. Conclusions: MRTR-based navigation resulted in rapid and optimal placement of interstitial brachytherapy catheters. Catheters were repositioned compared with the initial insertion without tracking. In pullback mode, catheter trajectories matched computed tomographic precision, enabling their use for RTP.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Paramagnetic Mn 8 Fe 4 -co-Polystyrene Nanobeads as a Potential T 1 –T 2 Multimodal Magnetic Resonance Imaging Contrast Agent with In Vivo Studies

In developing a cluster-nanocarrier design, as a magnetic resonance imaging contrast agent, we have investigated the enhanced relaxivity of a manganese and iron-oxo cluster grafted within a porous polystyrene nanobead with increased relaxivity due to a higher surface area. The synthesis of the cluster-nanocarrier for the cluster Mn 8 Fe 4 O 12 (O 2 CC 6 H 4 CH=CH 2 ) 16 (H 2 O) 4 , cross-linked with polystyrene (the nano-carrier), under miniemulsion conditions is described. By including a branched hydrophobe, iso-octane, the resulting nanobeads are porous and similar to 70 nm in diameter. The increased surface area of the nanobeads compared to nonporous nanobeads leads to an enhancement in relaxivity; r 1 increases from 3.8 to 5.2 ± 0.1 mM -1 s -1 , and r 2 increases from 11.9 to 50.1 ± 4.8 mM -1 s -1 , at 9.4 teslas, strengthening the potential for T 1 and T 2 imaging. Several metrics were used to assess stability, and the porosity produced no reduction in metal stability. Synchrotron X-ray fluorescence microscopy was used to demonstrate that the nanobeads remain intact in vivo . In depth, physicochemical characteristics were determined, including extensive pharmacokinetics, in vivo imaging, and systemic biodistribution analysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Spin transport, magnetoresistance, and electrically detected magnetic resonance in amorphous hydrogenated silicon nitride

We report on a study of spin transport via electrically detected magnetic resonance (EDMR) and near-zero field magnetoresistance (MR) in silicon nitride films. Silicon nitrides have long been important materials in solid state electronics. Although electronic transport in these materials is not well understood, electron paramagnetic resonance studies have identified a single dominating paramagnetic defect and have also provided physical and chemical descriptions of the defects, called K centers. Our EDMR and MR measurements clearly link the near-zero field MR response to the K centers and also indicate that K center energy levels are approximately 3.1 eV above the a-SiN:H valence band edge. In addition, our results suggest an approach for the study of defect mediated spin-transport in inorganic amorphous insulators via variable electric field and variable frequency EDMR and MR which may be widely applicable.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Computational study of runaway electrons in MST tokamak discharges with applied resonant magnetic perturbation

A numerical study of magnetohydrodynamics (MHD) and tracer-particle evolution investigates the effects of resonant magnetic perturbations (RMPs) on the confinement of runaway electrons (REs) in tokamak discharges conducted in the Madison Symmetric Torus. In computational results of applying RMPs having a broad toroidal spectrum but a single poloidal harmonic, m = 1 RMP does not suppress REs, whereas m = 3 RMP achieves significant deconfinement but not the complete suppression obtained in the experiment. MHD simulations with the NIMROD code produce sawtooth oscillations, and the associated magnetic reconnection can affect the trajectory of REs starting in the core region. Simulations with m = 3 RMP produce chaotic magnetic topology over the outer region, but the m = 1 RMP produces negligible changes in field topology, relative to applying no RMP. Using snapshots of the MHD simulation fields, full-orbit relativistic electron test particle computations with KORC show ≈50% loss from the m = 3 RMP compared to the 10%–15% loss from the m = 1 RMP. Here, test particle computations of the m = 3 RMP in the time-evolving MHD simulation fields show correlation between MHD activity and late-time particle losses, but total electron confinement is similar to computations using magnetic-field snapshots.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Magnetic Resonance Frequency Shifts of Spin-Polarized Cesium Atoms in a Cs–Rb Mixture

The interaction of spin-polarized cesium atoms with cesium and rubidium atoms under conditions of optical orientation of atoms is considered. On the basis of data on spin-exchange complex cross sections in the Cs–Cs and Cs–Rb systems, a calculation of a magnetic resonance frequency shift of cesium atoms in a Cs–Rb mixture, as well as comparison of the calculated values of the frequency shift with experimental data, is performed.

74 ATOMIC AND MOLECULAR PHYSICS↗

A resistive MHD model and simulation on plasma flow evolution in the presence of resonant magnetic perturbation in a tokamak

Nonaxisymmetric magnetic fields such as the intrinsic error field and the externally applied resonant magnetic perturbation (RMP) in a tokamak are known to influence the plasma momentum transport and flow evolution through plasma response, which itself strongly depends on the plasma flow as well. The nonlinear interaction between plasma response and flow has been previously modeled in the conventional error field theory with the “no-slip” condition, which has been recently extended to allow the “free-slip” condition. In this work, we further target this specific process and numerically simulate the nonlinear plasma response and flow evolution in the presence of a single-helicity RMP in a circular-shaped model tokamak configuration, based on the full resistive MHD model in the initial-value code NIMROD. Time evolution of the parallel (to k) flow or “slip frequency” profile and its asymptotic steady state obtained from the NIMROD simulations are compared with both conventional and extended nonlinear response theories. Here, k is the wave vector of the propagating island. Good agreement with the extended theory with free-slip condition has been achieved for the parallel flow profile evolution in response to RMP in all resistive regimes, whereas the difference from the conventional theory with the no-slip condition tends to diminish as the plasma resistivity approaches zero.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Direct imaging of neural currents using ultra-low field magnetic resonance techniques

Using resonant interactions to directly and tomographically image neural activity in the human brain using magnetic resonance imaging (MRI) techniques at ultra-low field (ULF), the present inventors have established an approach that is sensitive to magnetic field distributions local to the spin population in cortex at the Larmor frequency of the measurement field. Because the Larmor frequency can be readily manipulated (through varying B.sub.m), one can also envision using ULF-DNI to image the frequency distribution of the local fields in cortex. Such information, taken together with simultaneous acquisition of MEG and ULF-NMR signals, enables non-invasive exploration of the correlation between local fields induced by neural activity in cortex and more `distant` measures of brain activity such as MEG and EEG.

60 APPLIED LIFE SCIENCES↗

Comparative Dynamics of Leucine Methyl Groups in FMOC-Leucine and in a Protein Hydrophobic Core Probed by Solid-State Deuteron Nuclear Magnetic Resonance over 7-324 K Temperature Range

Quantitative dynamics of methyl groups in 9-fluorenylmethyloxycarbonyl-leucine (FMOC-leu) have been analyzed and compared with earlier studies of methyl dynamics in chicken villin headpiece subdomain protein (HP36) labeled at L69, a key hydrophobic core position. A combination of deuteron solid-state nuclear magnetic resonance experiments over the temperature range of 7-324 K and computational modeling indicated that while the two compounds show the same modes of motions, there are marked differences in the best-fit parameters of these motions. One of the main results is that the crossover observed in the dynamics of the methyl groups in the HP36 sample at 170 K is absent in FMOC-leu. A second crossover at around 95-88 K is present in both samples. The differences in the behavior of the two compounds suggest that some of the features of methyl dynamics reflect the complexity of the protein hydrophobic core and are not determined solely by local interactions.

59 BASIC BIOLOGICAL SCIENCES↗

Enhanced helium exhaust during edge-localized mode suppression by resonant magnetic perturbations at DIII-D

Effective helium confinement time, τ p * ,He , and its ratio with energy confinement time, τ p * ,He / τ E , are key metrics quantifying the suitability of fusion plasmas for a continuous burn. Comparisons in the DIII-D tokamak of discharges with suppression of edge localized modes (ELMs) by resonant magnetic field perturbations (RMPs) to the corresponding unperturbed ELMy discharges found that both of these metrics were strongly reduced, by a factor of approximately 2, after application of the RMPs. This reduction in τ p * ,He during RMP ELM suppression was observed in the plasma core, edge, and pumping plenum, where higher neutral helium concentration during RMPs was also measured. In conclusion, these findings provide evidence that future devices employing RMP ELM suppression may meet or even exceed the helium exhaust provided by the ELMs themselves, reducing helium ash, and thus maintaining high fusion gain.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Drift kinetic effects on plasma response to resonant magnetic perturbation for EU DEMO design

Abstract A systematic investigation of the plasma response to an externally applied resonant magnetic perturbation (RMP) field, for the purpose of controlling edge localized modes, is carried out for an EU DEMO reference plasma. Particular emphasis is placed on the role of kinetic effects associated with both thermal particles and fusion-born alphas. The single fluid, resistive model predicts a large peak amplification of the n = 1 ( n is the toroidal mode number) plasma response to the target equilibrium, which is found to be close to the Troyon no-wall limit. A more advanced response model, including kinetic resonances between the RMP perturbation and drift motions of thermal and energetic particles, on the other hand, finds a strong suppression of the n = 1 field amplification. A major role is played by the precessional drift resonance of fusion-born alphas. A strong parallel sound wave damping model is found to well reproduce the full kinetic response results for the DEMO plasma, in terms of both the resonant field response amplitude and the plasma displacement. Finally, both fluid and kinetic models produce similar responses for the n = 2 and 3 RMP fields for the considered DEMO plasma, whilst kinetic effects again become important for the n = 4 RMP due to proximity of the reference plasma to the no-wall limit for the n = 4 ideal kink instability.

Physics↗

H-1 Nuclear Magnetic Resonance Metabolomics Analysis Identifies Novel Urinary Biomarkers for Lung Function

Chronic obstructive pulmonary disease (COPD), characterized by chronic airflow limitation, is a serious and growing public health concern. The major environmental risk factor for COPD is tobacco smoking, but the biological mechanisms underlying COPD are not well understood. In this study, we used proton nuclear magnetic resonance (1H-NMR) spectroscopy to identify and quantify metabolites associated with lung function in COPD. Plasma and urine were collected from 197 adults with COPD and from 195 adults without COPD. Samples were assayed using a 600 MHz NMR spectrometer, and the resulting spectra were analyzed against quantitative spirometric measures of lung function. After correcting for false discoveries and adjusting for covariates (sex, age, smoking) several spectral regions in urine were found to be significantly associated with baseline lung function. These regions correspond to the metabolites trigonelline, hippurate and formate. Concentrations of each metabolite, standardized to urinary creatinine, were associated with baseline lung function (minimum p-value = 0.0002 for trigonelline). No significant associations were found with plasma metabolites. Two of the three urinary metabolites positively associated with baseline lung function, i.e. hippurate and formate, are often related to gut microflora. This suggests that the microbiome composition is variable between individuals with different lung function. Alternatively, the nature and origins of all three associated metabolites may reflect lifestyle differences affecting overall health. Our results will require replication and validation, but demonstrate the utility of NMR metabolomics as a screening tool for identifying novel biomarkers of lung disease or disease risk.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Nuclear spin conversion of water inside fullerene cages detected by low-temperature nuclear magnetic resonance

The water-endofullerene H{sub 2}O@C{sub 60} provides a unique chemical system in which freely rotating water molecules are confined inside homogeneous and symmetrical carbon cages. The spin conversion between the ortho and para species of the endohedral H{sub 2}O was studied in the solid phase by low-temperature nuclear magnetic resonance. The experimental data are consistent with a second-order kinetics, indicating a bimolecular spin conversion process. Numerical simulations suggest the simultaneous presence of a spin diffusion process allowing neighbouring ortho and para molecules to exchange their angular momenta. Cross-polarization experiments found no evidence that the spin conversion of the endohedral H{sub 2}O molecules is catalysed by {sup 13}C nuclei present in the cages.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Nuclear magnetic resonance study of hydrogen mobility in LaY{sub 2}Ni{sub 9}H{sub x} and CeY{sub 2}Ni{sub 9}H{sub x}

In order to investigate the mobility of hydrogen in the ternary compounds LaY{sub 2}Ni{sub 9} and CeY{sub 2}Ni{sub 9}, we have measured the proton nuclear magnetic resonance (NMR) spectra and the proton spin-lattice relaxation rates R{sub 1} for LaY{sub 2}Ni{sub 9}H{sub x} (x=0.78 and 10.3) and CeY{sub 2}Ni{sub 9}H{sub x} (x=0.79 and 7.2). The measurements have been performed at the resonance frequencies of 14, 23.8 and 90 MHz over the temperature range of 11-404 K. For LaY{sub 2}Ni{sub 9}H{sub x}, the behavior of R{sub 1} is consistent with the presence of a considerable contribution due to motionally modulated dipole-dipole interaction between nuclear spins. This contribution can be satisfactorily described in terms of the Bloembergen-Purcell-Pound model with a Gaussian distribution of activation energies for hydrogen diffusion; the value of the average activation energy resulting from such a description for LaY{sub 2}Ni{sub 9}H{sub 10.3} is approximately 0.36 eV. For CeY{sub 2}Ni{sub 9}H{sub x} compounds, the measured proton spin-lattice relaxation rates are dominated by the contribution due to the interaction between proton spins and paramagnetic centers over the entire temperature range studied. Only qualitative information on H mobility in these compounds has been obtained from the narrowing of NMR spectra. Possible paths of H diffusion in LaY{sub 2}Ni{sub 9}H{sub x} and CeY{sub 2}Ni{sub 9}H{sub x} are discussed in terms of the distances between the interstitial sites occupied by hydrogen. - Graphical abstract: The temperature dependences of the proton spin-lattice relaxation rates R{sub 1} measured at 14, 23.8 and 90 MHz for LaY{sub 2}Ni{sub 9}H{sub 10.3}. The frequency-dependent increase in R{sub 1} at T>250 K indicates the onset of the motional contribution to the relaxation rates.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Bi-directional magnetic resonance based wireless power transfer for electronic devices

In order to power or charge electronic devices wirelessly, a bi-directional wireless power transfer method has been proposed and experimentally investigated. In the proposed design, two receiving coils are used on both sides of a transmitting coil along its central axis to receive the power wirelessly from the generated magnetic fields through strongly coupled magnetic resonance. It has been observed experimentally that the maximum power transfer occurs at the operating resonant frequency for optimum electric load connected across the receiving coils on both side. The optimum wireless power transfer efficiency is 88% for the bi-directional power transfer technique compared 84% in the one side receiver system. By adopting the developed bi-directional power transfer method, two electronic devices can be powered up or charged simultaneously instead of a single device through usual one side receiver system without affecting the optimum power transfer efficiency.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Detection of biological uranium reduction using magnetic resonance

The conversion of soluble uranyl ions (UOurn:x-wiley:00063592:media:BIT24369:tex2gif-stack-1) by bacterial reduction to sparingly soluble uraninite (UO2(s)) is being studied as a way of immobilizing subsurface uranium contamination. Under anaerobic conditions, several known types of bacteria including iron and sulfate reducing bacteria have been shown to reduce U (VI) to U (IV). Experiments using a suspension of uraninite (UO2(s)) particles produced by Shewanella putrefaciens CN32 bacteria show a dependence of both longitudinal (T1) and transverse (T2) magnetic resonance (MR) relaxation times on the oxidation state and solubility of the uranium. Gradient echo and spin echo MR images were compared to quantify the effect caused by the magnetic field fluctuations (equation image) of the uraninite particles and soluble uranyl ions. Since the precipitate studied was suspended in liquid water, the effects of concentration and particle aggregation were explored. A suspension of uraninite particles was injected into a polysaccharide gel, which simulates the precipitation environment of uraninite in the extracellular biofilm matrix. A reduction in the T2 of the gel surrounding the particles was observed. Tests done in situ using three bioreactors under different mixing conditions, continuously stirred, intermittently stirred, and not stirred, showed a quantifiable T2 magnetic relaxation effect over the extent of the reaction.

54 ENVIRONMENTAL SCIENCES↗

Dynamics of asymmetric non-polymeric binary glass formers—A nuclear magnetic resonance and dielectric spectroscopy study

We study a dynamically asymmetric binary glass former with the low-T{sub g} component m-tri-cresyl phosphate (m-TCP: T{sub g} = 206 K) and a spirobichroman derivative as a non-polymeric high-T{sub g} component (T{sub g} = 382 K) by means of {sup 1}H nuclear magnetic resonance (NMR), {sup 31}P NMR, and dielectric spectroscopy which allow component-selectively probing the dynamics. The entire concentration range is covered, and two main relaxation processes with two T{sub g} are identified, T{sub g1} and T{sub g2}. The slower one is attributed to the high-T{sub g} component (α{sub 1}-process), and the faster one is related to the m-TCP molecules (α{sub 2}-process). Yet, there are indications that a small fraction of m-TCP is associated also with the α{sub 1}-process. While the α{sub 1}-relaxation only weakly broadens upon adding m-TCP, the α{sub 2}-relaxation becomes extremely stretched leading to quasi-logarithmic correlation functions at low m-TCP concentrations—as probed by {sup 31}P NMR stimulated echo experiments. Frequency-temperature superposition does not apply for the α{sub 2}-process and it reflects an isotropic, liquid-like motion which is observed even below T{sub g1}, i.e., in the matrix of the arrested high-T{sub g} molecules. As proven by 2D {sup 31}P NMR, the corresponding dynamic heterogeneities are of transient nature, i.e., exchange occurs within the distribution G(lnτ{sub α2}). At T{sub g1} a crossover is found for the temperature dependence of (mean) τ{sub α2}(T) from non-Arrhenius above to Arrhenius below T{sub g1} which is attributed to intrinsic confinement effects. This “fragile-to-strong” transition also leads to a re-decrease of T{sub g2}(c{sub m−TCP}) at low concentration c{sub m−TCP}, i.e., a maximum is observed in T{sub g2}(c{sub m−TCP}) while T{sub g1}(c{sub m−TCP}) displays the well-known plasticizer effect. Although only non-polymeric components are involved, we re-discover essentially all features previously reported for polymer-plasticizer systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Resonant-magnetic-perturbation-induced plasma transport in H-mode pedestals

Plasma toroidal rotation reduces reconnection of externally applied resonant magnetic perturbation (RMP) fields {delta}B on rational (q = m/n) magnetic flux surfaces. Hence, it causes radial perturbations {delta}B{sub {rho}m/n} to be small there, and thus inhibits magnetic island formation and stochasticity in the edge of high (H-) mode confinement tokamak plasmas. However, electron collisional damping combined with the spatial magnetic flutter {delta}B{sub {rho}m/n} induced by RMPs in the vicinity of rational surfaces causes a radial electron heat diffusivity in which {chi}{sub e Parallel-To }{sup eff}{approx}(v{sub Te}{sup 2}/{nu}{sub e})/(1+x{sup 2}/{delta}{sub Parallel-To }{sup 2}) is an effective parallel electron thermal diffusivity. These effects are reduced by magnetic shear effects at a distance x from rational surfaces for |x|>{delta}{sub Parallel-To} but amplified for {delta}B-caret{sub {rho}m/n}(x)>{delta}B-caret{sub {rho}m/n}(0). A kinetic, toroidal model of these RMP-flutter-induced plasma transport effects is developed and compared to a previously developed cylindrical model. The RMP-induced increases in plasma transport can be large enough to reduce plasma gradients in H-mode pedestals. Thus, they may contribute to suppressing edge localized modes in tokamak plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Toroidal modeling of penetration of the resonant magnetic perturbation field

A toroidal, quasi-linear model is proposed to study the penetration dynamics of the resonant magnetic perturbation (RMP) field into the plasma. The model couples the linear, fluid plasma response to a toroidal momentum balance equation, which includes torques induced by both fluid electromagnetic force and by (kinetic) neoclassical toroidal viscous (NTV) force. The numerical results for a test toroidal equilibrium quantify the effects of various physical parameters on the field penetration and on the plasma rotation braking. The neoclassical toroidal viscous torque plays a dominant role in certain region of the plasma, for the RMP penetration problem considered in this work.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗