Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MAGNETIC INSTRUMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Hydrodynamic Effects on Modeling and Control of a High Temperature Active Magnetic Bearing Pump with a Canned Rotor

Embedding instrumentation and control Embedding instrumentation and control (I\&C) at the component level in nuclear power plants can improve component performance, lifetime, and resilience by optimizing operation, reducing the constraints on physical design, and providing on-board prognostics and diagnostics. However, the extreme environments that many nuclear power plant components operate in makes embedding instrumentation and control at the component level difficult. Successfully utilizing embedded I\&C requires developing a deep understanding of the system's dynamics and using that knowledge to overcome material and physical limitations imposed by the environment. In this paper, we will develop a coupled dynamic model of a high temperature (700 $^\circ$C) canned rotor pump that incorporates rotordynamics, hydrodynamics, and active magnetic bearing dynamics. Then we will compare two control design methods, one that uses a simplified decoupled model of the system and another that utilizes the full coupled system model. It will be seen that utilizing all the available knowledge of the system dynamics in the controller design yield an order of magnitude improvement in the magnitude of the magnetic bearing response to disturbances at the same level of control effort, a large reduction in the settling time of the system, and a smoother control action.

Melin, Alexander M↗

Simulation of the Charged Particle Deflection From the Sweeping Magnet Array in the Lunar Environment Heliospheric X-Ray Imager

The Lunar Environment heliospheric X-ray Imager (LEXI) is an instrument built to image x-rays from solar wind charge exchange in Earth’s magneto sheath. Monitoring the position of the magnetopause at the inner boundary of the magneto sheath allows us to understand how magnetic reconnection regulates how energy from the solar wind is deposited into Earth’s magnetosphere. LEXI is part of an upcoming lunar lander mission set to land in Mare Crisium. To repel unwanted charged particles, the instrument carries a permanent magnet array composed of 48 neodymium magnets. The array was designed to maximize charged particle deflection while minimizing stray magnetic fields, which could impact other instruments or spacecraft operation. A Runge–Kutta-based fully kinetic particle tracing model was created to evaluate the effectiveness of LEXI’s unique charged particle deflector array. Combined with the other particle suppression measures of the instrument, including physical structures and filters, the simulations show proton and electron transmission to the LEXI detector is expected to be sufficiently reduced to allow successful imaging. The flexible simulation model can be generalized to be used in examining the magnetic deflector array effectiveness of other instruments whose signals could be compromised by unwanted charged particle contamination.

Space environment effects↗

High Data Rate Detector for Neutron Reflectometer

Neutron reflectometers are a class of instruments that employ neutron diffraction for measuring the structure of thin films. The technique provides valuable information over a wide variety of scientific and technological applications including chemical aggregation, polymer and surfactant adsorption, structure of thin film magnetic systems, biological membranes, etc. Such instruments are considered to be one of the most important in the neutron science field. Newer facilities place growing demands on the count rate capability of the specialized neutron detectors required. Proportional Technologies completed the Phase I effort successfully with a fully operational prototype detector built at PTI and tested at the CG1A neutron beam of the High Flux Isotope Reactor (HFIR, Oak Ridge, TN). The prototype incorporated 3 panels of 14 copper-walled cells each (total of 42 cells), each lined with 1.3 μm of 10B4C. The detector was tested for efficiency, spatial resolution, count rate linearity, uniformity, overlap and scatter. Testing revealed stable operation, uniform response across cells, and successful resolution of individual cells. The maximum count rate tested in the 3 panels combined was 590 kHz, limited by a deadtime of about 1 μs in the digital electronics. The local rate measured in a single cell showed no deadtime losses up to 810 cps/mm2, indicating that a rate of 20 Mhz can be supported in the 308-cell detector planned for Phase II.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Practical SQUID Instrument for Nondestructive Testing

We report on the development of a scanning eddy-current imaging system designed to detect deep subsurface flaws in conducting materials. A high transition temperature (high-T c) superconducting quantum interference device (SQUID) magnetometer is employed to provide the required sensitivity at low frequencies, while a combination of small cylindrical high-Tc superconducting and A-metal shields enable the instrument to be scanned in a magnetically noisy environment, rather than the object under test. The shields are arranged to prevent unwanted excitation and ambient noise fields from reaching the SQUID, and to enhance spatial resolution and minimize undesirable edge effects. Thus far, the instrument has successfully detected cracks and pits through 10 layers of aluminum, with a combined thickness of 5 cm at room temperature.

Tralshawala, N.↗

SPIDER OPTIMIZATION. II. OPTICAL, MAGNETIC, AND FOREGROUND EFFECTS

SPIDER is a balloon-borne instrument designed to map the polarization of the cosmic microwave background (CMB) with degree-scale resolution over a large fraction of the sky. SPIDER's main goal is to measure the amplitude of primordial gravitational waves through their imprint on the polarization of the CMB if the tensor-to-scalar ratio, r, is greater than 0.03. To achieve this goal, instrumental systematic errors must be controlled with unprecedented accuracy. Here, we build on previous work to use simulations of SPIDER observations to examine the impact of several systematic effects that have been characterized through testing and modeling of various instrument components. In particular, we investigate the impact of the non-ideal spectral response of the half-wave plates, coupling between focal-plane components and Earth's magnetic field, and beam mismatches and asymmetries. We also present a model of diffuse polarized foreground emission based on a three-dimensional model of the Galactic magnetic field and dust, and study the interaction of this foreground emission with our observation strategy and instrumental effects. We find that the expected level of foreground and systematic contamination is sufficiently low for SPIDER to achieve its science goals.

79 ASTRONOMY AND ASTROPHYSICS↗

Magnetic field studies at Jupiter by Voyager 2 - Preliminary results

The Voyager 2 magnetic field experiment, for which the instrumentation is identical to that on Voyager 1, operated flawlessly throughout the second Jupiter encounter. The paper presents a brief overview of the results obtained to date on the Jovian magnetosphere, the bow shock, the magnetopause, and the extended magnetic tail. The results and the magnetic field geometry confirm the earlier conclusion from Voyager 1 that Jupiter has an enormous magnetic tail, approximately 300-400 Jupiter radii in diameter, trailing behind the planet with respect to the supersonic flow of the solar wind. Additional observations of the distortion of the inner magnetosphere by a concentrated plasma show a spatial merging of the equatorial magnetodisk current with the current sheet in the magnetic tail. Disturbances near Ganymede are discussed.

Ness, N. F.↗

SHARAQ Spectrometer - Current status and future experimental plans

The high-resolution SHARAQ spectrometer and the dedicated high-resolution beamline have been constructed at RI beam factory and commissioned in 2009. Lateral and angular dispersion matching conditions were achieved simultaneously for a primary beam with a momentum spread of 0.1% and an emittance of 3pi mmcentre dotmrad (sigma). An overview of the spectrometer and the beam-line, preliminary results from the commissioning runs, and future experimental plan with the system are described.

43 PARTICLE ACCELERATORS↗

On the plasma conditions at the dayside magnetopause of Saturn

The energy densities epsilon(P) of the low energy ions measured by the Low Energy Charged Particle experiment on Voyager 1 and 2 are compared to the magnetic field energy densities derived from the magnetometer instrument during the crossing of the dayside Saturn magnetopause. The ratios of the proton to magnetic field energy densities are greater than about 0.5 during the Voyager 2 crossing when the magnetopause was at about 18 R(s). During the Voyager 1 crossing of the magnetopause at about 23 R(s), the ratios were about 0.1, although they approached one as the spacecraft entered the region near 18 R(s). The observations show that the dayside Saturnian magnetopause can at times have high beta plasma conditions, similar to the situation found at Jupiter.

Lanzerotti, L. J.↗

The Radiation Belt Storm Probes Mission: Advancing Our Understanding of the Earth's Radiation Belts

We describe NASA's Radiation Belt Storm Probe (RBSP) mission, whose primary science objective is to understand, ideally to the point of predictability, the dynamics of relativistic electrons and penetrating ions in the Earth's radiation belts resulting from variable solar activity. The overarching scientific questions addressed include: 1. the physical processes that produce radiation belt enhancement events, 2. the dominant mechanisms for relativistic electron loss, and 3. how the ring current and other geomagnetic processes affect radiation belt behavior. The RBSP mission comprises two spacecraft which will be launched during Fall 2012 into low inclination lapping equatorial orbits. The orbit periods are about 9 hours, with perigee altitudes and apogee radial distances of 600 km and 5.8 RE respectively. During the two-year primary mission, the spacecraft orbits precess once around the Earth and lap each other twice in each local time quadrant. The spacecraft are each equipped with identical comprehensive instrumentation packages to measure, electrons, ions and wave electric and magnetic fields. We provide an overview of the RBSP mission, onboard instrumentation and science prospects and invite scientific collaboration.

Sibeck, David↗

Ion Escape from the Ionosphere of Titan

Ions have been observed to flow away from Titan along its induced magnetic tail by the Plasma Science Instrument (PLS) on Voyager 1 and the Cassini Plasma Spectrometer (CAPS) on Cassini. In both cases, the ions have been inferred to be of ionospheric origin. Recent plasma measurements made at another unmagnetized body, Venus, have also observed similar flow in its magnetic tail. Much earlier, the possibility of such flow was inferred when ionospheric measurements made from the Pioneer Venus Orbiter (PVO) were used to derive upward flow and acceleration of H(+), D(+) and O(+) within the nightside ionosphere of Venus. The measurements revealed that the polarization electric field in the ionosphere produced the principal upward force on these light ions. The resulting vertical flow of H(+) and D(+) was found to be the dominant escape mechanism of hydrogen and deuterium, corresponding to loss rates consistent with large oceans in early Venus. Other electrodynamic forces were unimportant because the plasma beta in the nightside ionosphere of Venus is much greater than one. Although the plasma beta is also greater than one on Titan, ion acceleration is expected to be more complex, especially because the subsolar point and the subflow points can be 180 degrees apart. Following what we learned at Venus, upward acceleration of light ions by the polarization electric field opposing gravity in the ionosphere of Titan will be described. Additional electrodynamic forces resulting from the interaction of Saturn's magnetosphere with Titan's ionosphere will be examined using a recent hybrid model.

Hartle, R.↗

Single-point inversion of the coronal magnetic field

The Fe XIII 10747 and 10798 Å lines observed in the solar corona are sensitive to the coronal magnetic field in such a way that, in principle, the full vector field at a point on the line of sight can be inferred from their combined polarization signals. This paper presents analytical inversion formulae for the field parameters and analyzes the uncertainty of magnetic field measurements made from such observations, assuming emission dominated by a single region along the line of sight. We consider the case of the current Coronal Multi-channel Polarimeter (CoMP) instrument as well as the future Coronal Solar Magnetism Observatory (COSMO) and Advanced Technology Solar Telescope (ATST) instruments. Uncertainties are estimated with a direct analytic inverse and with a Markov Chain Monte Carlo algorithm. We find that (in effect) two components of the vector field can be recovered with CoMP, and well recovered with COSMO or ATST, but that the third component can only be recovered when the solar magnetic field is strong and optimally oriented.

79 ASTRONOMY AND ASTROPHYSICS↗

Performance of a short 'magnetic bottle' electron spectrometer

In this article, a newly constructed electron spectrometer of the magnetic bottle type is described. The instrument is part of an apparatus for measuring the electron spectra of free clusters using synchrotron radiation. Argon and helium outer valence photoelectron spectra have been recorded in order to investigate the characteristic features of the spectrometer. The energy resolution (E/{Delta}E) has been found to be {approx}30. Using electrostatic retardation of the electrons, it can be increased to at least 110. The transmission as a function of kinetic energy is flat, and is not impaired much by retardation with up to 80% of the initial kinetic energy. We have measured a detection efficiency of most probably 0.6{sub -0.1}{sup +0.05}, but at least of 0.4. Results from testing the alignment of the magnet, and from trajectory simulations, are also discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

NOVEL CRYOGENIC ENGINEERING SOLUTIONS FOR THE NEW AUSTRALIAN RESEARCH REACTOR OPAL

In August 2006 the new 20MW low enriched uranium research reactor OPAL went critical. The reactor has 3 main functions, radio pharmaceutical production, silicon irradiation and as a neutron source. Commissioning on 7 neutron scattering instruments began in December 2006. Three of these instruments (Small Angle Neutron Scattering, Reflectometer and Time-of-flight Spectrometer) utilize cold neutrons.The OPAL Cold Neutron Source, located inside the reactor, is a 20L liquid deuterium moderated source operating at 20K, 330kPa with a nominal refrigeration capacity of 5 kW and a peak flux at 4.2meV (equivalent to a wavelength of 0.4nm). The Thermosiphon and Moderator Chamber are cooled by helium gas delivered at 19.8K using the Brayton cycle. The helium is compressed by two 250kW compressors (one with a variable frequency drive to lower power consumption).A 5 Tesla BSCCO (2223) horizontal field HTS magnet will be delivered in the 2{sup nd} half of 2007 for use on all the cold neutron instruments. The magnet is cooled by a pulse tube cryocooler operating at 20K. The magnet design allows for the neutron beam to pass both axially and transverse to the field. Samples will be mounted in a 4K to 800K Gifford-McMahon (GM) cryofurnace, with the ability to apply a variable electric field in-situ. The magnet is mounted onto a tilt stage. The sample can thus be studied under a wide variety of conditions.A cryogen free 7.4 Tesla Nb-Ti vertical field LTS magnet, commissioned in 2005 will be used on neutron diffraction experiments. It is cooled by a standard GM cryocooler operating at 4.2K. The sample is mounted in a 2{sup nd} GM cryocooler (4K-300K) and a variable electric field can be applied.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Higher Order Suppressor (HOS) for the PolLux Microspectroscope Beamline at the Swiss Light Source SLS

The mechanical design and performance of a device to suppress higher orders of a spherical grating monochromator at a constant deviation angle is described. The higher order suppressor (HOS) is used for a scanning transmission x-ray microspectroscope beamline (PolLux) at a bending magnet of the Swiss Light Source (SLS). The instruments allow microspectroscopy in polymer science, of biological samples in the water window as well as the study of magnetic materials with circular or linear polarized light in a photon energy range of 200 eV to 1400 eV. The HOS uses three mirrors acting as a low pass filter for soft x-rays to improve the absorption spectroscopy of carbon, oxygen and nitrogen 1s core levels. The successful installation and operation of the HOS located after the monochromator is reported. First results obtained using samples from materials research and environmental sciences exemplify the improved spectroscopy capabilities of the instrument.

43 PARTICLE ACCELERATORS↗

A method to calibrate measurement instruments to optimize the spectrometer optics for experiment E94-107 at JLab

A method to calibrate measurement instruments through the fulfillment of physical laws is described. This method is particularly well suited to determine and/or improve magnetic spectrometer optics databases as well as to establish the best resolution achievable with them. Here, this method was applied to obtain the best resolution achievable in the excitation and binding energy spectra of several hypernuclei produced in the experiment E94-107 performed at JLab, allowing us to obtain sub-MeV resolutions.

47 OTHER INSTRUMENTATION↗

Flying Cages in Traveling Wave Ion Mobility: Influence of the Instrumental Parameters on the Topology of the Host–Guest Complexes

Supramolecular mass spectrometry has emerged in the last decade as an orthogonal method to access, at the molecular level, the structures of noncovalent complexes extracted from the condensed phase to the rarefied gas phase using electrospray ionization. It is often considered that the soft nature of the ESI source confers to the method the capability to generate structural data comparable to those in the condensed phase. In the present paper, using the ammonium ion/cucurbituril combination as a model system, we investigate using ion mobility and computational chemistry the influence of the instrumental parameters on the topology, i.e., internal versus external association, of gaseous host/guest complex ions. MS and theoretical data are confronted to condensed phase data derived from nuclear magnetic resonance spectroscopy to assess whether the instrumental parameters can play an insidious role when trying to derive condensed phase data from mass spectrometry results. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The ISEE 1 and 2 Medium Energy Particles Experiment

The Medium Energy Particles Experiment (MEPE) on board ISEE 1 and 2 consists of the WIM instrument on ISEE 1 and the KED instrument on ISEE 2. Both instruments employ solid-state detectors and magnetic analysis to measure the angular, energy, and intensity distributions of protons (ions) above 24 keV and electrons above 20 keV. The WIM instrument also includes a composition measurement employing Delta E-by-E and time-of-flight techniques. Three-parameter analysis is performed above 250 keV/nucleon, and single parameter analysis is performed above 125 keV/nucleon for helium through oxygen. Three-dimensional angular distributions are obtained through the use of a scan platform in the WIM instrument and multiple detector heads in the KED instrument. A variety of operational modes are used to optimize data collection from both instruments. Resolutions up to 128 channels in energy, 192 samples over the unit sphere in angle, and 0.095 sec in time are available.

Williams, D. J.↗