Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Light sources”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Characterizing Hidden Structures at NSLS-II: Strongly Correlated Electron Systems, Functional Ceramics, Batteries, and Beyond

Brookhaven National Laboratory (New York) launched its highenergy X-ray science program at the inception of the National Synchrotron Light Source (NSLS), a U.S. Department of Energy (DOE) Office of Science User Facility. Built in the 1980s, the NSLS X17 beamline was the world’s first super-conducting wiggler facility and remained in service for more than 30 years. The NSLS facility was decommissioned in October 2014 and a third-generation synchrotron machine, DOE’s National Synchrotron Light Source II (NSLS-II), took over. Six years after completing construction, NSLS-II has a portfolio of 29 beamlines that includes two operating high-energy powder diffraction beamlines (XPD and PDF) and one high-energy imaging and diffraction beamline under construction (HEX).

36 MATERIALS SCIENCE↗

Local Intensity Enhancements in Spherical Microcavities: Implications for Photonic Chemical and Biological Sensors

In this report, we summarize recent findings regarding the use spherical microcavities in the amplification of light that is inelastically scattered by either fluorescent or Raman-active molecules. This discussion will focus on Raman scattering, with the understanding that analogous processes apply to fluorescence. Raman spectra can be generated through the use of a very strong light source that stimulates inelastic light scattering by molecules, with the scattering occurring at wavelengths shifted from that of the source and being most prominent at shifts associated with the molecules natural vibrational frequencies. The Raman signal can be greatly enhanced by exposing a molecule to the intense electric fields that arise near surfaces (typically of gold or silver) exhibiting nanoscale roughness. This is known as surface-enhanced Raman scattering (SERS). SERS typically produces gain factors of 103 - 106, but under special conditions, factors of 1010 - 1014 have been achieved.

Fuller, Kirk A.↗

Laser measuring system for incremental assemblies

Wire-wrapped frame assemblies used in spark chambers and the like can be measured using a system which utilizes a laser, an interferometer, and a retroreflector to precisely measure distance. A light source and a photodetector are located adjacent the incremental assembly and mounted on a movable carriage. The interferometer is also mounted on the movable carriage, while the laser and retroreflector are positioned at either end of the carriage track. The carriage is moved along one edge of the incremental assembly between the retroreflector and the laser, and as the carriage is moved, the light from the light source to the photodetector is interrupted. This produces a trigger command to a control unit which in turn causes a distance measurement to be made. A printout is provided for each sampling trigger command to list such items as ideal position, actual position and amount of error.

Etzel, J. G.↗

Stellar occultation of polarized light from circumstellar electrons. 4: Detached binary systems

The finite sizes of stars in detached binary systems are incorporated in the single scattering approximation of Brown, McLean, & Emslie (1978). In the absence of scatterer occultation, the predicted polarimetric variability is found to be represented by a terminating two harmonic time series, as previously found by Brown et al. (1978). When the occultation of scatterers by the light sources is included, additional Fourier harmonics are introduced. Model results are illustrated for a spherically symmetric scattering envelope centered on the primary star, in which it is found that for occultation effects to be identified in polarimetric data requires the separation of the system to be less than 10 times the radius of the primary, and for the primary to be the dominant light source.

Fox, G. K.↗

Data-driven picosecond X-ray imaging for quantitative plasma-induced shock characterization

Imaging dynamic events, especially shockwave behavior, is key to advancing high-energy-density (HED) research. Recent advances in fourth- and fifth-generation X-ray light sources allow for high-resolution imaging of fast phenomena, but limited beam time necessitates maximizing data acquisition. We present a benchtop-scale pulsed plasma device submerged in liquid heptane, capable of generating dynamic events at rates exceeding 10 Hz, supporting the field’s data-driven goals by producing large, high-quality imaging datasets. Using X-ray phase contrast imaging (XPCI) at the Advanced Photon Source, we imaged weak shockwaves (Mach ~ 1.2) in heptane interacting with plasma-induced cavitation bubbles, causing deviation from Rankine-Hugoniot behavior; to our knowledge, this represents the first direct imaging of such interaction. Our quantitative analysis offers insight into weak shock phenomena and energy-focusing applications in pulsed plasmas. These results highlight the potential for large datasets to advance dynamic HED research at current light source facilities, and have implications for fields such as inertial confinement fusion, plasma-enhanced chemical processing, and biomedical applications.

36 MATERIALS SCIENCE↗

Machine learning enabling high-throughput and remote operations at large-scale user facilities

Imaging, scattering, and spectroscopy are fundamental in understanding and discovering new functional materials. Contemporary innovations in automation and experimental techniques have led to these measurements being performed much faster and with higher resolution, thus producing vast amounts of data for analysis. These innovations are particularly pronounced at user facilities and synchrotron light sources. Machine learning (ML) methods are regularly developed to process and interpret large datasets in real-time with measurements. However, there remain conceptual barriers to entry for the facility general user community, whom often lack expertise in ML, and technical barriers for deploying ML models. Herein, we demonstrate a variety of archetypal ML models for on-the-fly analysis at multiple beamlines at the National Synchrotron Light Source II (NSLS-II). We describe these examples instructively, with a focus on integrating the models into existing experimental workflows, such that the reader can easily include their own ML techniques into experiments at NSLS-II or facilities with a common infrastructure. The framework presented here shows how with little effort, diverse ML models operate in conjunction with feedback loops via integration into the existing Bluesky Suite for experimental orchestration and data management.

36 MATERIALS SCIENCE↗

Biotechnology Approaches to Life Detection

The direct detection of organic biomarkers for living or fossil microbes on Mars by an in situ instrument is a worthy goal for future lander missions. Several new and innovative biotechnology approaches are being explored. Firstly we have proposed an instrument based on immunological reactions to specific antibodies to cause activation of fluorescent stains. Antibodies are raised or acquired to a variety of general and specific substances that might be in Mars soil. These antibodies are then combined with various fluorescent stains and applied to micron sized numbered spots on a small (2-3 cm) test plate where they become firmly attached after freeze drying. Using technology that has been developed for gene mining in DNA technology up to 10,000 tests per square inch can now be applied to a test plate. On Mars or the planet/moon of interest, a sample of soil from a trench or drill core is extracted with water and/or an organic solvent and ultrasonication and then applied to the test plate. Any substance, which has an antibody on the test plate, will react with its antibody and activate its fluorescent stain. At the moment a small UV light source will illuminate the test plate, which is observed with a small CCD camera, although other detection systems will be applied. The numbered spots that fluoresce indicate the presence of the tested-for substance, and the intensity indicates relative amounts. Furthermore with up to a thousand test plates available false positives and several variations of antibody can also be screened for. The entire instrument can be quite small and light, on the order of 10 cm in each dimension. A possible choice for light source may be small UV lasers at several wavelengths. Some of the wells or spots can contain simply standard fluorescent stains used to detect live cells, dead cells, DNA, etc. The stains in these spots may be directly activated, with no antibodies being necessary. The proposed system will look for three classes of biomarkers: those from extant life, such as DNA, those from extinct life such as hopanes, and those from organic compounds not necessarily associated with life such as PAHs, rocket exhaust contamination and other a/pre-biotic chemicals. Both monoclonal and polyclonal antibodies can be used. Monoclonal antibodies react with a very specific compound, but polyclonal antibodies may react to any of a whole family of compounds. Furthermore the technique of phage display to raise antibodies against classically non-antigenic molecules is also being considered. Additional information is contained in the original extended abstract.

Steele, Andrew↗

An Optical Oxygen Sensor for Long-Term Continuous Monitoring of Dissolved Oxygen in Perfused Bioreactors

For long-term growth of man1ITlalian cells in perfused bioreactors, it is essential to monitor the concentration of dissolved oxygen (DO) present in the culture medium to quantitate and control level of DO. Continuous measurement of the amount of DO in the cell culture medium in-line under sterile conditions in NASA's perfused bioreactor requires that the oxygen sensor provide increased sensitivity and be sterilizable and nontoxic. Additionally, long-term cell culture experiments require that the calibration be maintained several weeks or months. Although there are a number of sensors for dissolved oxygen on the market and under development elsewhere, very few meet these stringent conditions. An optical oxygen sensor (BOXY) based on dynamic fluorescent quenching and a pulsed blue LED light source was developed in our laboratory to address these requirements. Tris( 4,7 -diphenyl-l, 1 O-phenanthroline )ruthenium(II) chloride is employed as the fluorescent dye indicator. The sensing element consists of a glass capillary (OD 4.0 mm; ID 2.0 mm) coated internally with a thin layer of the fluorescent dye in silicone matrix and overlayed with a black shielding layer. Irradiation of the sensing element with blue light (blue LED with emission maximum at 475 nm) generates a red fluorescence centered at 626 nm. The fluorescence intensity is correlated to the concentration of DO present in the culture medium, following the modified non-linear Stern-Volmer equation. By using a pulsed irradiating light source, the problem of dye-bleaching, which is often encountered in long-term continuous measurements of tIns type, 'is minimized. To date we achieved sensor resolution of 0.3 mmHg at 50 mmHg p02, and 0.6 mmHg at 100 mmHg p02, with a response time of about one minute. Calibration was accomplished in sterile phosphate-buffered saline with a blood-gas analyzer (BGA) measurement as reference. Stand-alone software was also developed to control the sensor and bioreactor as well as to acquire data. Two HOXY sensors with a single calibration were employed to continuously monitor the DO in GTSF-2 medium during a Baby Hamster Kidney (BHK-21) cell culture in a Rotating Wall Perfused Vessel (RWPV) bioreactor for 90 days. HOXY sensors were located at the inlet to and outlet from the bioreactor. One of the sensors was placed between an oxygenator and the inlet to the bioreactor. The dissolved oxygen concentrations determined by both sensors were compared with those measured regularly with the BGA reference. The cell culture was maintained for 110 days. Sensor output was found to correlate well with the BGA data throughout the experiment, where the DO of the medium ranged between 25 and 50 mmHg at the bioreactor outlet and 90-130 mmHg at the bioreactor inlet. Measuring DO with the HOXY sensors versus the BGA reference indicated bias values of -2 mmHg and -15 mmHg, and precision values of +/-3mmHg and +/-16 mmHg at the bioreactor inlet and outlet, respectively.

Gao, F. G.↗

Attosecond light science and its application for probing quantum materials

In this paper, we review the development and application of coherent short wavelength light sources implemented using the high harmonic generation (HHG) process. The physics underlying HHG brought quantum physics into the domain of attosecond time-scales for the first time. Here, the observation and manipulation of electron dynamics on such short time-scales—a capability not conceived—of just a few decades ago—is becoming both more-and-more sophisticated and useful as a route to achieve exquisite control over short wavelength light. New experimental techniques are enabling HHG light sources to provide new insights into fundamental quantum interactions in materials, making it possible for the first time to capture the fastest charge, spin, photon and phonon interactions and to achieve diffraction-limited imaging at short wavelengths.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Combining diagnostics, modeling, and control systems for automated alignment of the TES beamline

X-ray beamlines are essential components of all synchrotron light sources. Practical operations involve frequent variation in beamline component positions and orientation, particularly when photon beam parameters shift due to experimental needs, or due to variations in the incoming photon beam. The alignment process can be time consuming and takes away from valuable beam time for experimental data collection. We describe progress in the automation of certain alignment tasks on the tender-energy X-ray spectroscopy (TES) beamline at the National Synchrotron Light Source II (NSLS-II). The beamline is controlled using the BlueSky software in which high level experimental plans guide the beamline components during an experiment. Numerous software packages exist for beamline modeling, and they may be tied to the beamline control system using a package we are continuing to develop called Sirepo-Bluesky. The photon beam distribution may be measured with fluorescent screens, and a relation between beam and machine state can be found by varying the mirror and aperture settings over a multi-dimensional range. We describe the results of such parameter varying measurements and how we are combining Sirepo-Bluesky with machine learning methods and reduced models to automate mirror alignment on the TES beamline.

36 MATERIALS SCIENCE↗

Stability of the fcc phase in shocked nickel up to 332 GPa

Despite making up 5-20 wt.% of Earth’s predominantly iron core, the melting properties of elemental nickel at core conditions remain poorly understood, due largely to a dearth of experimental data. We present here an in situ X-ray diffraction study performed on laser shock-compressed samples of bulk nickel, reaching pressures up to ~ 500 GPa. Hugoniot states of nickel were targeted using a flat-top laser drive, with in situ X-ray diffraction data collected using the Linac Coherent Light Source. Rietveld methods were used to determine the densities of the shocked states from the measured diffraction data, while peak pressures were determined using a combination of measured particle velocities, shock transit times, hydrodynamic simulations, and laser intensity calibrations. We observed solid compressed face-centered cubic (fcc) Ni up to at least 332 ± 30 GPa along the Hugoniot—significantly higher than expected from the majority of melt lines that have been proposed for nickel. We also bracket the partial melting onset to between 377 ± 38 GPa and 486 ± 35 GPa.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Light-Emitting Diodes (LED) for Primary Animal Habitat Lighting in Highly Controlled Environments

Significant alterations in Biological Clock responses have been reported following sidereal time changes (e.g., Jet-lag), and exposure to microgravity (e.g., daytime sleepiness). Additionally, light reduces circulating melatonin (spectral specificity greatest between 450-500 nm). It was hypothesized that LEDs can replace the current light sources used in zero gravity and terrestrial research laboratories because of their small size, low mass, low energy consumption and long functional life. This report evaluates the capacity of LEDs to entrain the circadian system of rats as judged by measurement of overt behavioral circadian rhythms (activity, feeding, drinking). These data were collected in highly controlled environments similar to the shuttle Animal Enclosure Modules. Two groups were compared: control - animals exposed to standard cool-white fluorescent lights, and test - animals exposed to LEDs with a spectral power distribution matching the fluorescent lights. Gross locomotor activity, feeding and drinking frequencies were continuously monitored and stored at 10 minute intervals. Animals were exposed to the following photoperiods: 28 days of 12L:12D, 19 days of 24L:0D and 16 days of 12L:12D. Light intensities tested varied between 0.1 to 100 lux. Rats received food and water ad libitum, and temperature and humidity were controlled throughout the study. The general health status of all rats was acceptable for each day of this study. No incidents of aggressive behavior were observed. Growth, locomotor activity, food and water consumption were comparable for all groups of animals, i.e, the circadian characteristics of the animals under these conditions were comparable. These results indicate that LED arrays are as effective in maintaining circadian rhythm stability as the commonly used cool-white fluorescent light sources. LEDs with their flexible spectrum, low energy requirements and minimal heat production have advantages for some chronopharmacology studies and for microgravity animal habitats.

Winget, C. M.↗

Bending Magnet Synchrotron Radiation Imaging with Large Orbital Collection Angles

Synchrotron radiation (SR) from bending magnets, wigglers, and undulators is now extensively produced for users at storage ring based light sources, with unique properties in terms of average brightness and stability. Here, we present a profound study of bending magnet SR intensity distribution in the image plane of a focusing optical system. Measurements of this intensity distribution at the MAX-IV low emittance storage ring are compared to theoretical predictions, and found to be in excellent agreement. This work shows upon the possibility of performing high resolution emittance diagnostics with visible or near-visible SR on upcoming low-emittance storage ring based light sources. As a byproduct of our study, we derive a closed analytical expression for the intensity distribution from a zero-emittance beam, in the limiting case of wide orbital collection angles. This expression finally allows us to demonstrate the meeting between classical electrodynamics applied to SR emission and focusing, and the Landau and Lifshitz prediction of radiation intensity distribution nearby a caustic.

36 MATERIALS SCIENCE↗

Synthesis and Observation of Emergent Phenomena in Epitaxial Heusler Compound Heterostructures

The proposal was on the synthesis and observation of emergent phenomena in epitaxial Heusler compound heterostructures. The large range of properties and number of Heusler compounds opens up a wide number of potential compounds that will exhibit emergent phenomena. The similarity, large range of relatively inexpensive, large area, high crystal quality, III-V bulk substrates, lattice parameters and the ability to tune the lattice parameters through ternary or quaternary III-V compound semiconductor epitaxial growth, makes III-V semiconductors an ideal choice for substrates for epitaxial growth of Heusler compounds. A number of half Heusler compounds have been predicted to exhibit band inversion, making them topological and are therefore expected to exhibit spin-momentum locked topological surface states with linear dispersion. Others are predicted to be semimetals with Weyl points and others semiconducting and magnetic. During the course of this grant, emphasis has been on investigating Heusler compounds with emergent phenomena and demonstrating the ability to tune their properties through alloying and strain. We have grown toplogical semimetal (PtLuSb, PtMnBi), Weyl (Co 2 MnAl, Co 2 TiGe), half metal (PtMnSb, Co 2 MnSi, Co 2 MnAl x Si 1-x , Co2FeAl), and semiconducting (CoTiSb, NiTiSn) and tuned their properties through alloying and epitaxial strain. We also investigated the closely related materials of rare-earth monopnictide, some of which have also been predicted to be topological. During the attempts to grow the PtMnBi, it was discovered that Bi, another predicted topological material when ultrathin, could be grown epitaxially on InSb, results for which are also reported here. The main focus for this effort has been on using variable photon energy and spin-dependent angle resolved photoemission (ARPES) to determine bulk band structure and surface states of pristine epitaxial films grown on III-V semiconductor and MgO substrates and correlate results with theory and transport measurements. Theory has been critical to interpretation of experimental results and has been essential in guiding experiments. The research benefited from several strong collaborations between the PIs and the beamline scientists at the Advanced Light Source at Lawrence Berkeley Laboratory, the Stanford Linear Accelerator Center (SLAC) at Stanford and at the Max Lab at Lund University in Sweden. The strong experiment - theory collaboration between the PI’s groups, the Palmstrøm group at UCSB and the Janotti group at the University of Delaware, has been critical for interpreting the experimental ARPES and magnetotransport measurements results and making predictions to guide experiments. Weekly interactive Zoom meetings made this work well. A collaboration between the Palmstrøm group and Dr. Alexei Fedorov at the Advanced Light Source (ALS) resulted in significant modifications to his end chamber to accommodate the vacuum suitcase that was designed and constructed in the Palmstrøm group at UCSB. In collaboration with beamline scientists, Drs. Makoto Hashimoto and Donghui Lu at SLAC, Palmstrøm made modifications to the vacuum suitcase and developed special sample holders that allowed samples to be grown in the Palmstrøm MBE systems at UCSB and transported in the UHV vacuum suitcase to SLAC for ARPES measurements. The development of the vacuum suitcase was essential for this grant as it has allowed variable photon energies to be used to identify surface versus bulk states on samples that could not be capped and decapped using As- or Sb-capping layers.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Photothermal heterodyne imaging of micron-sized objects

Micron-sized dye-doped polymer beads were imaged using transmitted/reflected light microscopy and photothermal heterodyne imaging (PHI) measurements. The transmitted/reflected light images show distinct ring patterns that are attributed to diffraction effects and/or internal reflections within the beads. In the PHI experiments pump laser induced heating changes the refractive index and size of the bead, which causes changes in the diffraction pattern and internal reflections. This creates an analogous ring pattern in the PHI images. The ring pattern disappears in both the reflected light and PHI experiments when an incoherent light source is used as a probe. When the beads are imaged in an organic medium heat transfer changes the refractive index of the environment, and gives rise to a ring pattern external to the beads in the PHI images. This causes the beads to appear larger than their physical dimensions in PHI experiments. This external signal does not appear when the beads are imaged in air because the refractive index changes in air are very small.

Bhandari, Janak (ORCID:0000000188423259)↗

Active Wide-Field Sky Simulator Design for the JPL Astrometry Testbed

Exoplanet detection through astrometry will provide mass measurements that are key to our understanding of exoplanet demographics. Astrometric surveys are also critical pre-cursor observations for identifying targets for future direct imaging missions, such as the HabEx and LUVOIR mission concepts. However, Earth-mass planets orbiting Sun-like stars within 10 pc only cause a 0.3 uas astrometric signal, which is about two orders of magnitude smaller than the current state-of-the-art. In order to advance the technologies needed for future astrometry instruments, a testbed capable of simulating and measuring equivalent Earth-like exoplanet astrometric signals was created. The testbed has a stable light source that simulates a field of stars and can introduce a sub-uas astrometric signal onto a central artificial target star. This is done by illuminating an array of pinholes lithographically printed onto a glass substrate and translating, with picometer resolution, a target-star pinhole located on a centrally cut flexure feature. To detect this motion, a diffractive pupil is used to calibrate the limiting optical distortions of an Offner relay. Presented in this paper are the requirements, design, and implementation of the wide-field astrometry testbed’s light source.

Bendek, Eduardo↗

Application and performance of the novel Elcomat 5000 autocollimator in slope-measuring profilometry of beamline optics

Autocollimators are used in profilometers for the precise form measurement of beam-shaping optics for synchrotron light sources and x-ray free-electron lasers. This application requires using an aperture stop, typically 2.5 mm in diameter, which limits the footprint of the autocollimator’s measuring beam on the optics to achieve a sufficiently high lateral resolution. Central to the development of profilometry has been the availability of commercial autocollimators, such as the Elcomat 3000 from Möller–Wedel Optical. Although autocollimators are generally not designed for use with small apertures, this device has proven capable and has become the de facto standard. Now that it has been replaced by the Elcomat 5000, we evaluate the performance of several autocollimators of this type at small apertures, including the characterization of instrument transfer functions with a chirped height profile. We demonstrate that the Elcomat 5000 is capable of repeatable angle measurements with a standard deviation of 0.014 arcsec at an aperture diameter of 1.6 mm, whereas the Elcomat 3000 achieves 0.03 arcsec at 2.5 mm, comparing models with modified reticle designs. Here, we also investigate the influence of optical aberrations of the autocollimator’s objective and their changes with the path length to the surface under test. We characterize the sensitivity of the angle measurement to changes in environmental parameters, in particular, barometric pressure. These efforts are aimed at approaching fundamental limits in the characterization of the shape of optical surfaces with autocollimator-based profilometers so that these are ready for characterizing the next generation of synchrotron and XFEL beamline optics.

angle metrology↗

Effects of Cryogenic Temperatures on LEDs and Optical Fiber

Light Emitting Diodes (LEDs) may provide a simple, low powered light source for future space missions. However, the effects of cryogenic temperatures on LEDs and optical fibers are largely unknown. Tests were performed on a selection of commercially-available LEDs, with wavelengths varying from 468 nm to 950 nm, as well as "white" LEDs. Dry ice and liquid nitrogen (LN2) were used to bring the LEDs to the desired temperatures. The optical fibers were tested using a specially-machined brass cylinder that would allow the fibers to be cooled slowly and evenly in an LN2 dewer. An optical fiber coupled to a spectrometer was used to acquired spectra of a calibration light source (wavelength range 253-922 nm) at various temperatures. Examination of the LED spectra has shown several different effects, depending on the LED in question. Those with wavelengths above 590 nm tend to show a "blue shift" in their peak wavelength and an increase in intensity. Other LEDs developed secondary or tertiary peaks, or showed no peak shift at all, although all LEDs did show an increase in observed intensity. The optical fiber showed a slight non-uniform decrease in transmission as the temperature cooled to -195 C.

Pantel, Erica R.↗