Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “LOSS CONE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Experimental investigation of the subsonic high-altitude operation of the NASA Lewis 10- by 10-foot supersonic wind tunnel

An experimental investigation was conducted in the NASA Lewis 10- by 10-Foot Supersonic Wind Tunnel during subsonic tunnel operation in the aerodynamic cycle to determine the test section flow characteristics near the Advanced Turboprop Project propeller model plane of rotation. The investigation used an eight-probe pitot static flow survey rake to measure total and static pressures at two locations in the wind tunnel: the test section and the bellmouth section (upstream of the two-dimensional flexible-wall nozzle). A cone angularity probe was used to measure any flow angularity in the test section. The evaluation was conducted at tunnel Mach numbers from 0.10 to 0.35 and at three operating altitudes from 2,000 to 50,000 ft. which correspond to tunnel reference total pressures from 1960 to 245 psfa, respectively. The results of this experimental investigation indicate a total-pressure loss area in the center of the test section and a static-pressure gradient from the test section centerline to the wall. These total and static pressure differences were observed at all tunnel operating altitudes and diminished at lower tunnel velocities. The total-pressure loss area was also found in the bellmouth section, which indicates that the loss mechanism is not the tunnel flexible-wall nozzle. The flow in the test section is essentially axial since very small flow angles were measured. The results also indicate that a correction to the tunnel total and static pressures must be applied in order to determine accurate freestream conditions at the test section centerline.

Hughes, Christopher E.↗

Cervix Motion in 50 Cervical Cancer Patients Assessed by Daily Cone Beam Computed Tomographic Imaging of a New Type of Marker

Purpose: To evaluate a new type of marker and a new method of marker implantation and to assess interfraction cervix motion for a large population of patients with locally advanced cervical cancer by daily cone beam computed tomographic (CBCT) imaging. Methods and Materials: We investigated the position of markers in 50 patients treated in prone position during at least 23 fractions. To reduce streaking artifacts in the planning CT scan, a new type of polymeric marker was used and compared with conventional gold markers. In addition, a new method of implantation was used in an attempt to reduce marker loss. In each fraction, a CT scan was acquired before dose delivery and aligned to the bony anatomy of the planning CT scan, simulating the clinical setup protocol. First, sufficient visibility of the markers was verified. Then, systematic and random displacement of the marker centroids was recorded and analyzed in 3 directions with regard to the planning CT and the first CBCT (to evaluate the presence of a vaginal catheter in the planning CT). Streaking artifacts were quantified with the standard deviation of the mean squared intensity difference in a radius around the marker. Results: Marker loss was minimal during treatment: in only 3 of the 50 patients 1 marker was lost. Streaking artifacts for the new markers were reduced compared with conventional gold markers. For the planning CT, M/Σ/σ were 0.4/3.4/2.2 mm, 1.0/5.5/4.5 mm, and −3.9/5.1/3.6 mm for the left-right, anterior-posterior, and cranial-caudal directions, respectively. With regard to the first CBCT scan, M/Σ/σ were 0.8/2.8/2.1, 0.6/4.4/4.4, and −1.3/4.5/3.6 mm. Conclusions: A new type of marker and implantation method was shown to have significantly reduced marker loss and streaking artifacts compared with gold fiducial markers. The recorded marker displacement confirms results reported in the existing literature but for a larger dataset.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Linear Boltzmann transport for jet propagation in the quark-gluon plasma: Inelastic processes and jet modification

A linear Boltzmann transport (LBT) Monte Carlo model has been developed to describe jet propagation and interaction with the quark-gluon plasma (QGP) in relativistic heavy-ion collisions. A complete set of elastic-scattering processes and medium-induced gluon emissions based on the higher-twist formalism are incorporated for both jet shower and medium recoil partons. It has been employed to describe experimental data on large transverse momentum hadron and jet spectra, correlation and jet substructures in high-energy heavy-ion collisions. Here, we document in detail the structure of the model and validation of the Monte Carlo implementations of the physics processes in LBT, in particular, the inelastic process of medium-induced gluon radiation. We carry out a comprehensive examination of the jet-medium interaction as implemented in LBT through energy loss and momentum broadening of a single hard parton, the energy and transverse momentum transfer from leading partons to medium-induced gluons and jet-induced medium excitation, and medium modification of reconstructed jets in a static and uniform medium. With realistic and event-by-event hydrodynamic medium in heavy-ion collisions, we compute and compare with experimental data on the jet cone-size dependence of the single inclusive jet suppression at both the BNL Relativistic Heavy-Ion Collider (RHIC) and the CERN Large Hadron Collider (LHC), the dijet asymmetry at the LHC and γ-jet correlation at RHIC. Effects of medium-induced gluon emissions and jet-induced medium excitation on jet observables are systematically examined. Rescatterings of the radiated gluons and recoil partons with the QGP are found essential to account for the enhancement of soft particle yield toward the edge of the jet cone.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Early-time radiation flux symmetry optimization and its effect on gas-filled hohlraum ignition targets on the National Ignition Facility

Achieving ignition on the National Ignition Facility (NIF) is tied to our ability to control and minimize deviations from sphericity of the capsule implosion. Low-mode asymmetries of the hot spot result from the combined effect of radiation drive asymmetries throughout the laser pulse and initial roughness on the capsule surface. In this paper, we report on simulations and experiments designed to assess, measure, and correct the drive asymmetries produced by the early-time (≈first 2 ns or “picket”) period of the laser pulse. The drive asymmetry during the picket is commonly thought to introduce distortions in the hot-spot shape at ignition time. However, a more subtle effect not previously considered is that it also leads to an asymmetry in shock velocity and timing, thereby increasing the fuel adiabat and reducing the margin for ignition. It is shown via hydrodynamic simulations that minimizing this effect requires that the early-time asymmetry be kept below 7.5% in the second Legendre mode (P{sub 2}), thus keeping the loss of performance margin below ≈10% for a layered implosion. Asymmetries during the picket of the laser pulse are measured using the instantaneous self-emission of a high-Z re-emission sphere in place of an ignition capsule in a hohlraum with large azimuthal diagnostic windows. Three dimensional simulations using the code HYDRA (to capture the effect of non-azimuthal hohlraum features) coupled to a cross-beam energy transfer model [Michel et al., Phys. Plasmas 17, 056305 (2010)] are used to establish the surrogacy of the re-emit target and to assess the early-time drive symmetry. Calculations using this model exhibit the same sensitivity to variations in the relative input powers between the different cones of NIF beams as measured for the “Rev5” CH target [Haan et al., Phys Plasmas 18, 051001 (2011)] and reported by Dewald et al. [Phys. Rev. Lett. 111, 235001 (2013)]. The same methodology applied to recently improved implosions using different hohlraum geometries and picket powers show good agreement with experimental data.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Optimal PV Inverter Control in Distribution Systems via Data-Driven Distributionally Robust Optimization

Distribution systems with high penetration of uncertain solar generation call for advanced control strategies of photovoltaics (PVs) inverters. This paper proposes a data-driven distributionally robust optimization (DDDRO) approach to optimally controlling the PV inverters to improve the system operation performance under solar power uncertainties. In the proposed DDDRO approach, a Wasserstein ball-based method is proposed to construct the distributional ambiguity set to model the uncertainties of PV generation through partial observations of historical data without knowing exact probability distributions. We further reformulate the computationally intractable DDDRO model to a mixed integer second order cone programming (MISOCP) problem. The effectiveness and out-of-sample performance of the proposed approach have been demonstrated on a modified IEEE 33-node system. We conduct a comparative study to compare the proposed method with traditional chance constrained programming (CCP). It shows that the proposed DDDRO approach can provide a less conservative yet robust solution to minimize the worse-case expectation of the total network loss while maintaining nodal voltages in a secure range.

Xue, Yaosuo↗

Computational Validation of a Two-Dimensional Semi-Empirical Model for Inductive Coupling in a Conical Pulsed Inductive Plasma Thruster

A two-dimensional semi-empirical model of pulsed inductive thrust efficiency is developed to predict the effect of such a geometry on thrust efficiency. The model includes electromagnetic and gas-dynamic forces but excludes energy conversion from radial motion to axial motion, with the intention of characterizing thrust efficiency loss mechanisms that result from a conical versus a at inductive coil geometry. The range of conical pulsed inductive thruster geometries to which this model can be applied is explored with the use of finite element analysis. A semi-empirical relation for inductance as a function of current sheet radial and axial position is the limiting feature of the model, restricting the applicability as a function of half cone angle to a range from ten degrees to about 60 degrees. The model is nondimensionalized, yielding a set of dimensionless performance scaling parameters. Results of the model indicate that radial current sheet motion changes the axial dynamic impedance parameter at which thrust efficiency is maximized. This shift indicates that when radial current sheet motion is permitted in the model longer characteristic circuit timescales are more efficient, which can be attributed to a lower current sheet axial velocity as the plasma more rapidly decouples from the coil through radial motion. Thrust efficiency is shown to increase monotonically for decreasing values of the radial dynamic impedance parameter. This trend indicates that to maximize the radial decoupling timescale should be long compared to the characteristic circuit timescale.

Hallock, Ashley K.↗

Heating effects on jack pine pyrogenic organic matter properties from a pyrocosm study in 2022

This dataset contains data associated with the preprint “Fire removes preexisting pyrogenic organic matter from the ecosystem through the mechanisms of both direct combustion and increasing mineralizability” (Luo et al., 2025b), which is the complementary study to the published paper “Reburning pyrogenic organic matter: a laboratory method for dosing dynamic heat fluxes from above” (Luo et al., 2025a). We designed a full-factorial experiment with different burial depths of jack pine (Pinus banksiana Lamb) pyrogenic organic matter (PyOM) (Surface, 1 cm, and 5 cm) and different heat-flux profiles (High, Low, and Control) to examine how subsequent fires affect the properties of preexisting PyOM. We measured total carbon (C), pH, dissolved organic carbon (DOC), dissolved inorganic carbon (DIC), and mineralized C (as CO₂-C, from a 12-week incubation).We found that high heat flux and/or surface placement resulted in substantial direct C losses through combustion. Intermediate heat exposure produced both combustion losses and increases in DOC and mineralizability, which may have complex long-term implications: an increased dissolved fraction of PyOM may promote downward transport into mineral soils and potentially contribute to deeper, longer-term C storage, but it may also make PyOM more susceptible to microbial decomposition. Under the lowest heat flux and deepest burial, most PyOM was retained, and changes in DOC and C mineralization were minimal. Finally, PyOM pH, an important chemical property, decreased under low-temperature heating but increased under higher temperatures.We uploaded pH data for all samples (“pH_of_all_samples.csv”); pH and temperature-related data (peak temperature and degree hours) for samples in High and Low heat-flux treatments (“pH_vs_peakT_and_degree_hours_only_for_heated_samples.csv”); total C data (“CN_pct_C_stock_C_loss_in_samples.csv”); DOC and DIC data (“doc_dic.csv”); and mineralized C (CO₂-C) data (“CO2-C_all_original.csv”). Additional details can be found in the Methods & Sampling section.All datasets uploaded to ESS-DIVE are clearly labeled, cleaned, and include both raw and derived data, ready for reuse in other analyses. All analysis code and raw datasets are also available on GitHub: https://github.com/MengmengLuo/Fire-removes-preexisting-pyrogenic-organic-matter-from-the-ecosystem.

54 ENVIRONMENTAL SCIENCES↗

Effect of different breathing patterns in the same patient on stereotactic ablative body radiotherapy dosimetry for primary renal cell carcinoma: A case study

Stereotactic ablative body radiotherapy (SABR) for primary renal cell carcinoma (RCC) targets requires motion management strategies to verify dose delivery. This case study highlights the effect of a change in patient breathing amplitude on the dosimetry to organs at risk and target structures. A 73-year-old male patient was planned for receiving 26 Gy of radiation in 1 fraction of SABR for a left primary RCC. The patient was simulated with four-dimensional computed tomography (4DCT) and the tumor internal target volume (ITV) was delineated using the 4DCT maximum intensity projection. However, the initially planned treatment was abandoned at the radiation oncologist's discretion after pretreatment cone-beam CT (CBCT) motion verification identified a greater than 50% reduction in superior to inferior diaphragm motion as compared with the planning 4DCT. This patient was resimulated with respiratory coaching instructions. To assess the effect of the change in breathing on the dosimetry to the target, each plan was recalculated on the data set representing the change in breathing condition. A change from smaller to larger breathing showed a 46% loss in planning target volume (PTV) coverage, whereas a change from larger breathing to smaller breathing resulted in an 8% decrease in PTV coverage. ITV coverage was similarly reduced by 8% in both scenarios. This case study highlights the importance of tools to verify breathing motion prior to treatment delivery. 4D image guided radiation therapy verification strategies should focus on not only verifying ITV margin coverage but also the effect on the surrounding organs at risk.

61 RADIATION PROTECTION AND DOSIMETRY↗

Relating reconnection rate, exhaust structure and effective resistivity

The magnetic reconnection structure consists of a central diffusion region (CDR) and a cone or wedge shaped reconnection exhaust containing accelerated plasma flows and electromagnetic fluctuations. We predict here the relationship among the exhaust half-cone angle (θ{sub e}), the half width (w) of the CDR, the outflow velocity V{sub o}, and the effective resistivity (η{sub eff}), which includes the effects of all the nonideal terms in the generalized Ohm's law. The effective resistivity is defined as the ratio of reconnection electric field E{sub rec} to the current density J{sub y} at the X point and it essentially represents the loss of momentum from the current-carrying plasma particles due to scattering by waves, their inertia or outflux from the CDR. The relation is checked against relevant results previously reported from laboratory experiments, space observations, and simulations, showing excellent agreement. The relation can be used for estimating the ad-hoc effective resistivity often used in magnetohydrodynamic modeling of reconnection.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ar-40/Ar-39 ages and cosmic ray exposure ages of Apollo 14 samples.

We have used the Ar-40/Ar-39 dating technique on eight samples of Apollo 14 rocks (14053, 14310), breccia fragments (14321), and soil fragments (14001, 14167). The large basalt fragments give reasonable Ar-40/Ar-39 release patterns and yield well defined crystallization ages of 3.89-3.95 aeons. Correlation of the Ar-40/Ar-39 release patterns with Ar-39/Ar-37 patterns showed that the low temperature fractions with high radiogenic argon loss came from K-rich phases. A highly shocked sample and fragments included in the breccia yield complex release patterns with a low temperature peak. The total argon age of these fragments is 3.95 aeons. Cosmic ray exposure ages on these samples are obtained from the ratio of spallogenic Ar-38 to reactor induced Ar-37 and show a distinct grouping of low exposure ages of 26 m.y. correlated with Cone crater. Other samples have exposure ages of more than 260 m.y. and identify material with a more complex integrated cosmic age exposure history.

Turner, G.↗

Channel electron multipliers - Detection efficiencies with opaque MgF2 photocathodes at XUV wavelengths

Detection efficiencies of channel electron multipliers (CEM) with opaque MgF2 photocathodes obtained in the extreme ultraviolet (XUV), 44 A to 990 A, are reported. A stable highly efficient response is reported for that interval, with no adverse effects on CEM performance. Efficiencies twice those of uncoated CEMs are obtained for 50 A to 350 A. The Mullard B419BL and Galileo 4510WL single-stage cone-cathode CEMs were used in the experiments. A rare-gas double ionization chamber was employed as absolute standard detector for 406 A to 990 A, and a flow Geiger counter filled with 96% argon and 4% isobutane for 44 A to 256 A. Absolute detection efficiencies are 10% higher from 67 A to 990 A when photocathodes are illuminated at an angle of incidence 45 deg. The photocathodes suffered no loss of response in storage (in vacuum or air) after an initial aging period. Effects of scattered UV radiation are greatly reduced when MgF2-coated CEMs are used in the XUV.

Lapson, L. B.↗

Assessment of Interfraction Patient Setup for Head-and-Neck Cancer Intensity Modulated Radiation Therapy Using Multiple Computed Tomography-Based Image Guidance

Purpose: Various image guidance systems are commonly used in conjunction with intensity modulated radiation therapy (IMRT) in head-and-neck cancer irradiation. The purpose of this study was to assess interfraction patient setup variations for 3 computed tomography (CT)-based on-board image guided radiation therapy (IGRT) modalities. Methods and Materials: A total of 3302 CT scans for 117 patients, including 53 patients receiving megavoltage cone-beam CT (MVCBCT), 29 receiving kilovoltage cone-beam CT (KVCBCT), and 35 receiving megavoltage fan-beam CT (MVFBCT), were retrospectively analyzed. The daily variations in the mediolateral (ML), craniocaudal (CC), and anteroposterior (AP) dimensions were measured. The clinical target volume-to-planned target volume (CTV-to-PTV) margins were calculated using 2.5Σ + 0.7 σ, where Σ and σ were systematic and random positioning errors, respectively. Various patient characteristics for the MVCBCT group, including weight, weight loss, tumor location, and initial body mass index, were analyzed to determine their possible correlation with daily patient setup. Results: The average interfraction displacements (± standard deviation) in the ML, CC, and AP directions were 0.5 ± 1.5, −0.3 ± 2.0, and 0.3 ± 1.7 mm (KVCBCT); 0.2 ± 1.9, −0.2 ± 2.4, and 0.0 ± 1.7 mm (MVFBCT); and 0.0 ± 1.8, 0.5 ± 1.7, and 0.8 ± 3.0 mm (MVCBCT). The day-to-day random errors for KVCBCT, MVFBCT, and MVCBCT were 1.4-1.6, 1.7, and 2.0-2.1 mm. The interobserver variations were 0.8, 1.1, and 0.7 mm (MVCBCT); 0.5, 0.4, and 0.8 mm (MVFBCT); and 0.5, 0.4, and 0.6 mm (KVCBCT) in the ML, CC, and AP directions, respectively. The maximal calculated uniform CTV-to-PTV margins were 5.6, 6.9, and 8.9 mm for KVCBCT, MVFBCT, and MVCBCT, respectively. For the evaluated patient characteristics, the calculated margins for different patient parameters appeared to differ; analysis of variance (ANOVA) and/or t test analysis found no statistically significant setup difference in any direction. Conclusions: Daily random setup errors and CTV-to-PTV margins for treatment of head-and-neck cancer were affected by imaging quality. Our data indicated that larger margins were associated with MVFBCT and MVCBCT, compared with smaller margins for KVCBCT. IGRT modalities with better image quality are encouraged in clinical practice.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Control of low-mode drive asymmetry in an efficient long-pulse low gas-fill density Hohlraum

Laser-driven Hohlraums filled with gas at lower densities (<0.6 mg/cc) have higher efficiency compared to original ≥ 0.96 mg/cc fill because of reduced backscatter losses [Hall et al., Phys. Plasmas 24, 052706 (2017)]. However, using low-density filled Hohlraums with longer drive required for lower adiabat implosions, and hence potentially higher inertial confinement fusion gain designs, has been challenging since the Hohlraum wall blow-off is less tamped, thus altering the laser beam absorption regions and drive symmetry. A series of NIF experiments using optimized pulse shaping, beam pointing, and temporal phasing have demonstrated, through imaging of the Hohlraum and capsule dynamics, that a symmetric implosion using a 14-ns low-adiabat drive pulse {2× longer than high-density-carbon ablator designs using low gas-fill density Hohlraums [Divol et al., Phys. Plasmas 24, 056309 (2017)]} is possible in a low backscatter loss 0.45 mg/cc He-filled Hohlraum. The ingress of the Hohlraum walls was mitigated by revisiting the adiabat-shaped design [Clark et al., Phys. Plasmas 21, 112705 (2014)] that uses a low-power (1 TW) trough that delays the wall expansion. Low-mode P 2 and P 4 drive asymmetry swings caused by the drift of the laser spots were essentially zeroed out by employing temporal beam phasing between cones of beams [Turner et al., Phys. Plasmas 7, 333 (2000)]. So the results also indicate an improved coupling efficiency of ~30% compared to an earlier design using higher density filled Hohlraums and pave the way for revisiting low-adiabat, high convergence drives using CH ablators.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

3D Magnetohydrodynamic Models of Nonthermal Photon Emission in the Binary System γ{sup 2} Velorum

Recent reports claiming an association of the massive star binary system γ{sup 2} Velorum (WR 11) with a high-energy γ-ray source observed by Fermi-LAT contrast the so far exclusive role of η Carinae as the hitherto only detected γ-ray emitter in the source class of particle-accelerating colliding-wind binary (CWB) systems. We offer support to this claim of association by providing dedicated model predictions for the nonthermal photon emission spectrum of γ{sup 2} Velorum. We use 3D magnetohydrodynamic modeling (MHD) to investigate the structure and conditions of the wind-collision region (WCR) of γ{sup 2} Velorum including the important effect of radiative braking in the stellar winds. A transport equation is then solved for the entire computational domain to study the propagation of relativistic electrons and protons. The resulting distributions of particles are subsequently used to compute nonthermal photon emission components. In agreement with observation in X-ray spectroscopy, our simulations yield a large shock-cone opening angle. We find the nonthermal γ-ray emission of γ{sup 2} Velorum to be of hadronic origin owing to the strong radiation fields in the binary system, which inhibit the acceleration of electrons to energies sufficiently high for efficient inverse-Compton radiation. We also discuss the strong dependence of a hadronic γ-ray component on the energy-dependent diffusion used in the simulations. Of two mass-loss rates for the WR star found in literature, only the higher rate is able to accommodate the observed γ-ray spectrum with reasonable values for important simulation parameters such as the injection ratio of high-energy particles within the WCR.

79 ASTRONOMY AND ASTROPHYSICS↗

Testing of 3-meter Prototype Fault Current Limiting Cables

Two 3-m long, single-phase cables have been fabricated by Ultera from second generation (2G) superconductor supplied by American Superconductor. The first cable was made with two layers of 2G tape conductor and had a critical current of 5,750 A while the second cable had four layers and a critical current of 8,500 A. AC loss was measured for both cables at ac currents of up to 4 kArms. Ultera performed initial fault current studies of both cables in Denmark with limited currents in the range from 9.1 to 44 kA. Results from these tests will provide a basis for a 25-m long, three-phase, prototype cable to be tested at ORNL early next year and a 300-m long, fault current limiting, superconducting cable to be installed in a ConEd substation in New York City.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Quantifying mass flows at Mt. Cleveland, Alaska between 2001 and 2020 using satellite photogrammetry

Measuring eruption volume provides constraints on the magma supply rate and plumbing systems and therefore is a critical component for monitoring volcanoes. We use ArcticDEM—a large collection of time-dependent digital elevation models (DEMs) derived from satellite stereo-photogrammetry — to construct a first-of-its-kind measurement of the volumes of recent mass flows at Mount Cleveland, Alaska. We quantify the volume of the products of the 2001 eruption (the largest in the past half-century) as (54.8 ± 0.5) × 10 -6 m -3 covering a total area of 5.09 km -2 . The total volume of material loss at the summit crater is (0.67 ± 0.02) × 10 -6 m -3 , which is likely caused by later explosions and collapses of the shallow magma chamber. The total eruptive volume between 2017 and 2020 is (0.086 ± 0.002) × 10 -6 m -3 . Elevation changes associated with lahars are variable. On the upper northern slopes of the volcano, the lahar channels were almost exclusively erosive, suggesting that lahars originating at the summit eroded and entrained loose materials high on the cone. In general, lahar deposits were thickest near their toes, with some reaching ~20 m thickness.

Chunli Dai↗

Demonstration of low-mode shape control in indirect-drive double shell implosions at the NIF

Double shell inertial confinement fusion is a concept for achieving robust thermonuclear burn that uses dense metal shells to compress deuterium-tritium (DT) fuel to fusion conditions. Double shell implosions are typically indirectly driven and involve a target that consists of a low-Z ablator, a foam layer, and a high-Z pusher surrounding the DT fuel. The goal of the campaign is to achieve a volumetric burn as radiation losses from the DT fuel are trapped by the opaque high-Z shell. The overall performance of double shell implosions relies on the efficient collisional transfer of kinetic energy between layers. The efficiency of this transfer (and therefore the overall performance of a given implosion) is degraded by the presence of low-mode asymmetries. P2 asymmetries are often observed in spatially resolved 2D radiographs of nominal double shell implosions. This work discusses three such experiments: one with an oblate P2 asymmetry, one with a prolate P2 asymmetry, and one with an approximate spherical symmetry. After performing a shape analysis of the oblate and prolate implosions to quantify asymmetries, these experimental results were compared with the results of hydrodynamic simulations for the two experiments. Differences between the experiment and simulation were then used to design an approximately spherical implosion by altering the incident laser cone fraction. Radiographs from the experiment that implemented the modified cone fraction show evidence of an implosion that is approximately spherical until bang time. This design is intended to serve as a point design for future studies that will seek to optimize various aspects of the double shell target.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Angular distribution of Cherenkov radiation from relativistic heavy ions taking into account deceleration in the radiator

Numerical methods are used to study the dependence of the structure and the width of the angular distribution of Vavilov-Cherenkov radiation with a fixed wavelength in the vicinity of the Cherenkov cone on the radiator parameters (thickness and refractive index), as well as on the parameters of the relativistic heavy ion beam (charge and initial energy). The deceleration of relativistic heavy ions in the radiator, which decreases the velocity of ions, modifies the condition of structural interference of the waves emitted from various segments of the trajectory; as a result, a complex distribution of Vavilov-Cherenkov radiation appears. The main quantity is the stopping power of a thin layer of the radiator (average loss of the ion energy), which is calculated by the Bethe-Bloch formula and using the SRIM code package. A simple formula is obtained to estimate the angular distribution width of Cherenkov radiation (with a fixed wavelength) from relativistic heavy ions taking into account the deceleration in the radiator. The measurement of this width can provide direct information on the charge of the ion that passes through the radiator, which extends the potentialities of Cherenkov detectors. The isotopic effect (dependence of the angular distribution of Vavilov-Cherenkov radiation on the ion mass) is also considered.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗