Brain protein deciphered at Advanced Light Source

This computer-generated model of a rat glutamate receptor is the first complete portrait of this important link in the nervous system. At the top of the Y-shaped protein, a pair of molecules splay outward like diverging prongs. The bottom section, which is embedded in a neuronal membrane, houses the ion channel. The resolution of this image is 3.6 angstroms per pixel, or just under four ten-billionths of a meter per image unit. http://newscenter.lbl.gov/feature-stories/2010/01/21/glutamate-receptor/

43 PARTICLE ACCELERATORS↗

Single plasmonic split hole resonator nanostructure as an efficient nanoscale light source

We report a brief review of the results of experimental studies on the nonlinear optical interaction of laser radiation with a hybrid plasmonic nanostructure, i.e. a split hole resonator (SHR). We demonstrate second- and third-harmonic generation and mixed-frequency generation from a single SHR nanostructure. The practical application potential of an SHR nanostructure as a nanoprobe for measuring the femtosecond laser pulse duration and designing an all-optical nanodisplay is shown. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Cold-target recoil-ion momentum spectroscopy for diagnostics of high harmonics of the extreme-ultraviolet free-electron laser light source at SPring-8

We have developed a cold-target recoil-ion momentum spectroscopy apparatus dedicated to the experiments using the extreme-ultraviolet light pulses at the free-electron laser facility, SPring-8 Compact SASE Source test accelerator, in Japan and used it to measure spatial distributions of fundamental, second, and third harmonics at the end station.

43 PARTICLE ACCELERATORS↗

Cavity formation in a liquid Sn droplet driven by laser ablation pressure for an extreme ultraviolet light source target

An in situ approach to the formation of cavities in liquid Sn droplets for the purpose of increasing ion density from Sn plasma produced by a CO{sub 2} laser is investigated. Two-dimensional hydrodynamic simulations, treating the laser as a pulsed pressure source, are compared both spatially and temporally to experimental shadowgraphs for verification of cavity formation. It is shown that a 15 ns pulse from a 1.064 {mu}m laser with intensity of 2 x 10{sup 10} W/cm{sup 2} creates a cavity approximately 300 {mu}m wide and 100 {mu}m deep in approximately 1.4 {mu}s. The presence of the cavity enhances the conversion of laser energy to 13.5 nm radiation from the plasma.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Reconciling FTIR Spectroscopy with Top-off Operations at the Advanced Light Source

Top-off operations is a quasi-continuous injection mode that increases the flux and brightness of a synchrotron source and improves thermal stability of optical components by maintaining a constant current in the storage ring. Although the increased and constant flux is advantageous for FTIR measurements, the frequent injections (about one every 30 seconds in the ALS case) introduce artifacts into the spectrum by creating spikes in the interferogram data. These spikes are caused by brief beam motion during the injection event. Here, we describe our efforts to minimize the effects of top-off generated interferogram spikes on several FTIR spectrometers. They include using a fast feedback mirror system to correct for beam motion and a gating signal to inhibit interferogram collection during a top-off injection.

43 PARTICLE ACCELERATORS↗

From 3rd- to 4th-generation light sources: Free-electron lasers in the X-ray range

Activities on free-electron laser (FEL) x-ray sources, based on linear accelerators, to produce spatially coherent, ultra-short ({approx}100 fs) pulses with very high peak brilliance (10{sup 28}-10{sup 32} photons/s/mm{sup 2}/mrad{sup 2}/0.1% BW) are summarized. The scientific case includes time-resolved studies of dynamics on sub-ps scales, structural studies by imaging of non-periodic systems, and investigation of high energy-density phenomena such as non-linear x-ray optics and the production of warm dense matter. Examples are presented, with emphasis on the operational facilities, FLASH at DESY, Hamburg and LCLS in Stanford, California, and on the European XFEL project in Hamburg.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Reconciling FTIR Spectroscopy with Top-off Operations at the Advanced Light Source

Top-off operations is a quasi-continuous injection mode that increases the flux and brightness of a synchrotron source and improves thermal stability of optical components by maintaining a constant current in the storage ring. Although the increased and constant flux is advantageous for FTIR measurements, the frequent injections (about one every 30 seconds in the ALS case) introduce artifacts into the spectrum by creating spikes in the interferogram data. These spikes are caused by brief beam motion during the injection event. Here, we describe our efforts to minimize the effects of top-off generated interferogram spikes on several FTIR spectrometers. They include using a fast feedback mirror system to correct for beam motion and a gating signal to inhibit interferogram collection during a top-off injection.

47 OTHER INSTRUMENTATION↗

Soft x-ray scattering facility at the Advanced Light Source with real-time data processing and analysis

We present the development and characterization of a dedicated resonant soft x-ray scattering facility. Capable of operation over a wide energy range, the beamline and endstation are primarily used for scattering from soft matter systems around the carbon K-edge ({approx}285 eV). We describe the specialized design of the instrument and characteristics of the beamline. Operational characteristics of immediate interest to users such as polarization control, degree of higher harmonic spectral contamination, and detector noise are delineated. Of special interest is the development of a higher harmonic rejection system that improves the spectral purity of the x-ray beam. Special software and a user-friendly interface have been implemented to allow real-time data processing and preliminary data analysis simultaneous with data acquisition.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Nanoscience Beamline (I06) at Diamond Light Source

The Nanoscience beamline (I06) is one of seven Diamond Phase-I beamlines which has been operational since January 2007 delivering polarised soft x-rays, for a PhotoEmission Electron Microscope (PEEM) and branchline, in the energy range 80-2100 eV. The beamline is based on a collimated plane grating monochromator with sagittal focusing elements, utilising two APPLE II helical undulator sources, and has been designed for high flux density at the PEEM sample position. A {approx}5 {mu}m ({sigma}) diameter beam is focussed onto the sample in the PEEM allowing a range of experiments using x-ray absorption spectroscopy (XAS), x-ray magnetic circular dichroism (XMCD) and x-ray magnetic linear dichroism (XMLD) as contrast mechanisms. The beamline is also equipped with a branchline housing a 6T superconducting magnet for XMCD and XMLD experiments. The magnet is designed to move on and off the branchline which allows a diverse range of experiments.

43 PARTICLE ACCELERATORS↗

A Test Beamline on Diamond Light Source

A Test beamline B16 has been built on the 3 GeV Diamond synchrotron radiation source. The beamline covers a wide photon energy range from 2 to 25 keV. The beamline is highly flexible and versatile in terms of the available beam size (a micron to 100 mm) and the range of energy resolution and photon flux; by virtue of its several operational modes, and the different inter-changeable instruments available in the experiments hutch. Diverse experimental configurations can be flexibly configured using a five-circle diffractometer, a versatile optics test bench, and a suite of detectors. Several experimental techniques including reflectivity, diffraction and imaging are routinely available. Details of the beamline and its measured performance are presented.

43 PARTICLE ACCELERATORS↗

Cryogenic X-ray crystallographic studies of biomacromolecules at Turkish Light Source " Turkish DeLight "

X-ray crystallography is a robust and powerful structural biology technique that provides high-resolution atomic structures of biomacromolecules. Scientists use this technique to unravel mechanistic and structural details of biological macromolecules (e.g., proteins, nucleic acids, protein complexes, protein-nucleic acid complexes, or large biological compartments). Since its inception, single-crystal cryocrystallography has never been performed in Türkiye due to the lack of a single-crystal X-ray diffractometer. The X-ray diffraction facility recently established at the University of Health Sciences, Istanbul, Türkiye will enable Turkish and international researchers to easily perform high-resolution structural analysis of biomacromolecules from single crystals. Here, we describe the technical and practical outlook of a state-of-the-art home-source X-ray, using lysozyme as a model protein. The methods and practice described in this article can be applied to any biological sample for structural studies. Therefore, this article will be a valuable practical guide from sample preparation to data analysis.

59 BASIC BIOLOGICAL SCIENCES↗

Preliminary Commissioning and Performance of the Soft X-ray Micro-characterization Beamline at the Canadian Light Source

The Soft X-ray Micro-characterization Beamline (SXRMB) is a medium energy, bending magnet based beamline, designed to cover an energy range of 1.7-10 keV using two sets of crystals--InSb(111) and Si(111). The design goal is to deliver a flux of 2x10{sup 11} photons sec{sup -1}/100 mA with a resolution up to 10,000 for X-ray Absorption Spectroscopy. A KB mirror stage is designed to provide microprobe capability, with a spot size of 10x10 {mu}m{sup 2} and a flux of >10{sup 9} at the microprobe station. The beamline has been in the commissioning phase since 2008, and access to the X-ray absorption endstation is now open to general users. The optical commissioning and performance of the beamline is presented with some early experimental results.

43 PARTICLE ACCELERATORS↗

2-3 {mu}m mid infrared light sources using InGaAs/GaAsSb ''W'' type quantum wells on InP substrates

We have investigated the InGaAs/GaAsSb/InAlGaAs/InAlAs type-II ''W'' quantum wells (QWs) grown on InP substrates by molecular beam epitaxy. The photoluminescence (PL) emission wavelength longer than 2.56 {mu}m at room temperature (RT) is demonstrated for the first time in this material system. The PL emission peaks of our designed samples can cover a wide range from 2 to 2.5 {mu}m at cryogenic temperature. The samples show good optical quality that the reduction in integrated PL intensity is only around one order of magnitude from 35 K to RT. We found that the integrated PL intensity decreased as the emission wavelength increased, which is due to the reduction in the electron-hole wave function overlap. This is consistent with the calculated result. In the power dependent PL measurements, the emission peak of ''W'' type QWs show blue shifts with the excitation power (P{sub ex}) but does not follow the P{sub ex}{sup 1/3} rule as predicted by type-II band bending model. The localized states filling effect gives reasonable explanations for the observed phenomena.

36 MATERIALS SCIENCE↗

Robotic sample changers for macromolecular X-ray crystallography and biological small-angle X-ray scattering at the National Synchrotron Light Source II

In this work, we present two robotic sample changers integrated into the experimental stations for the macromolecular crystallography (MX) beamlines AMX and FMX, and the biological small-angle scattering (bioSAXS) beamline LiX. They enable fully automated unattended data collection and remote access to the beamlines. The system designs incorporate high-throughput, versatility, high-capacity, resource sharing and robustness. All systems are centered around a six-axis industrial robotic arm coupled with a force torque sensor and in-house end effectors (grippers). They have the same software architecture and the facility standard EPICS-based BEAST alarm system. The MX system is compatible with SPINE bases and Unipucks. It comprises a liquid nitrogen dewar holding 384 samples (24 Unipucks) and a stay-cold gripper, and utilizes machine vision software to track the sample during operations and to calculate the final mount position on the goniometer. The bioSAXS system has an in-house engineered sample storage unit that can hold up to 360 samples (20 sample holders) which keeps samples at a user-set temperature (277 K to 300 K). The MX systems were deployed in early 2017 and the bioSAXS system in early 2019.

36 MATERIALS SCIENCE↗

Plasma dynamics of a confined extreme ultraviolet light source

Laser plasmas were generated by ablation of aluminum targets via a Nd:YAG glass laser, of pulse energy 0.8 J, and duration 15 ns (full width at half maximum) at the fundamental wavelength (1.064 {mu}m). Emission lines in the wavelength range of 27-32 nm (45-37.8 eV) were mapped over a spatial range extending out 1.8 mm from the target surface and for a temporal range of 42 ns after the termination of the laser pulse. Two targets were utilized: a planar surface and a rectangular cavity. The latter was composed of a rectangular shaped cavity of depth 3 mm and height 1.2 mm, cut into an aluminum massive. An irradiance of I{sub p{approx}}10{sup 11} W/cm{sup 2} was delivered to both targets and the confining influence of the rectangular cavity upon plasma formation and expansion was studied. Diagnostics of the emitted spectra reveal the unique dynamics of restricted plasma plume expansion, which results in plasma-surface collisions and subsequent plasma rebound within the cavity. These effects give rise to strong enhancement of both continuum and line emission in the contained plasma plume. These enhancements are especially evident for the more highly charged ions. Superior emission from plasma-surface collisions are associated with ''forced recombination'' during early time scales, while enhanced emission at later stages are associated with plasma plume component rebound and collision.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Laser Safety for the Experimental Halls at SLAC_s Linac Coherent Light Source (LCLS)

The LCLS at the SLAC National Accelerator Laboratory will be the world's first source of an intense hard x-ray laser beam, generating x-rays with wavelengths of 1nm and pulse durations less than 100fs. The ultrafast x-ray pulses will be used in pump-probe experiments to take stop-motion pictures of atoms and molecules in motion, with pulses powerful enough to take diffraction images of single molecules, enabling scientists to elucidate fundamental processes of chemistry and biology. Ultrafast conventional lasers will be used as the pump. In 2009, LCLS will deliver beam to the Atomic Molecular and Optical (AMO) Experiment, located in one of 3 x-ray Hutches in the Near Experimental Hall (NEH). The NEH includes a centralized Laser Hall, containing up to three Class 4 laser systems, three x-ray Hutches for experiments and vacuum transport tubes for delivering laser beams to the Hutches. The main components of the NEH laser systems are a Ti:sapphire oscillator, a regen amplifier, green pump lasers for the oscillator and regen, a pulse compressor and a harmonics conversion unit. Laser safety considerations and controls for the ultrafast laser beams, multiple laser controlled areas, and user facility issues are discussed.

43 PARTICLE ACCELERATORS↗

The Physics of the Gas Attenuator for the Linac Coherent Light Source (LCLS)

A systematic assessment of a variety of physics issues affecting the performance of the LCLS X-ray beam attenuator is presented. Detailed analysis of the gas flow in the gas attenuator and in the apertures is performed. A lot of attention is directed towards the gas ionization and heating by intense X-ray pulses. The role of these phenomena in possible deviations of the attenuation coefficient from its 'dialed in' value is evaluated and found small in most cases. Other sources of systematic and statistical errors are also discussed. The regimes where the errors may reach a few percent correspond to the lower X-ray energies (less than 2 keV) and highest beam intensities. Other effects discussed include chemical interaction of the gas with apertures, shock formation in the transonic flow in the apertures of the attenuator, generation of electromagnetic wakes in the gas, and head-to-tail variation of the attenuation caused by the ionization of gas or solid. Possible experimental tests of the consistency of the physics assumptions used in the concept of the gas attenuator are discussed. Interaction of X-rays with the solid attenuator (that will be used at higher X-ray energies, from 2.5 to 8 keV) is considered and thermo-mechanical effects caused by the beam heating are evaluated. Wave-front distortions induced by non-uniform heating of both the solid and the gas are found to be small. An overall conclusion drawn from the analysis presented is that the attenuator will be a reliable and highly versatile device, provided that some caution is exercised in its use for highest beam intensities at lowest X-ray energies.

43 PARTICLE ACCELERATORS↗