Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Isotopes and Radiation Sources”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Minimum Detectable Quantity Calculation for Radiation Portal Monitors

The minimum detectable quantity of a radiation portal monitor is the smallest amount of radioactive material that can be detected passing through the monitor (with a specified detection probability). The minimum detectable quantity is a function of many factors, including isotope, velocity, distance between pillars, height of portal and vehicle, source distribution and position, background radiation, background suppression, detector volume and positions, detector efficiency, decision metrics and algorithms, the presence of NORM (naturally occurring radioactive material), and alarm thresholds. Experimentally testing a radiation portal monitor to failure for all combinations of these factors is extremely time-consuming and often cost prohibitive. This document outlines a straightforward method for quickly estimating the minimum detectable quantity for moving sources over a large variety of conditions with a minimal number of static measurements. The document also describes a proof of concept software application that the International Atomic Energy Agency has designed based on the described method that can be used by Member States to estimate a monitor’s minimum detectable quantity.

Blessinger, Christopher S.↗

Distinguishing fissile uranium isotopes using an active well neutron coincidence counter

Proposed thorium-based nuclear fuel cycles are likely to require quantification and verification of 233 U within nuclear material. Because of their similar fission cross sections, active neutron nondestructive assay (NDA) systems may respond similarly to 233 U and 235 U. Traditional safeguards equipment has been optimized for 235 U and 238 U quantification associated with conventional uranium/plutonium fuel cycles and may not be directly applicable to 233 U quantification when mixed with other actinides. This work used models of the large volume active well coincidence counter (LV-AWCC) at Oak Ridge National Laboratory to evaluate the performance of this neutron NDA system to differentiate fissile uranium isotopes. The models were developed to simulate NDA system performance in response to a number of triangular radiation signature training device sources within the central cavity or well. This work predicted that the LV-AWCC can effectively differentiate 233 U from 235 U in certain modes of operation. In active mode, the LV-AWCC with the cadmium liner results in different doubles count rates between the fissile isotopes for a given fissile uranium mass. Without the cadmium liner, the uranium isotopes provide a statistically indistinguishable doubles count rate response for the fissile masses considered in this work (up to approximately 150 g). The cadmium liner serves to harden the neutron interrogation spectrum, which better exploits the notable difference in the 233 U and 235 U fission cross sections at approximately 1 eV. In passive mode, the two fissile isotopes exhibit different doubles and singles count rates regardless of liner presence because the passive source strength of 233 U is approximately 2 orders of magnitude stronger than that of 235 U due to the shorter half-life and correspondingly higher (α, n) yield. We conclude that using neutron interrogation in the LV-AWCC, two measurements are needed to quantify 233 U content in mixed uranium items. The first measurement is used to determine the total fissile uranium mass using a mode that cannot distinguish fissile isotopes (i.e., where a similar response is observed for both fissile uranium isotopes such as active doubles without cadmium or using a thermal neutron interrogation source). In conclusion, the second measurement is used to determine the 233 U content by using a differentiating technique (e.g., passive doubles, passive doubles to singles ratio, active doubles with cadmium).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron resonance transmission analysis prototype system for thorium fuel cycle safeguards

Emerging thorium-based reactor designs and fuel cycles present challenges to traditional non-destructive assay techniques used in international safeguards. Specifically, assaying the masses of 233 U and 235 U when they are present together in samples with high gamma ray backgrounds is difficult because of similar passive neutron signatures and relatively weak gamma-ray emissions of 233 U. The Pacific Northwest National Laboratory (PNNL) and the Massachusetts Institute of Technology (MIT) are developing a compact neutron resonance transmission analysis (NRTA) system as one potential solution to these challenges. The NRTA technique provides isotopic information for a sample via neutron time-of-flight (TOF) measurements that exploit a sample’s epithermal neutron resonance cross-sections. A recently developed portable NRTA system uses a commercially available, pulsed deuterium-tritium neutron generator with a ~2 m flight path and a GS20 lithium glass scintillator detector. Finally, this paper describes the prototype NRTA system design, a refined radiation transport model of the system, preliminary measurements with thorium and uranium sources, and demonstration of a quantitative isotopic estimation algorithm.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Radiation Signature Training Device Gamma Equivalent Spheres

Radiation signature training device sources are a continuation of a previous effort to produce a highly enriched uranium equivalent sphere. The original research was designed and motivated to produce a Department of Transportation special form source that emulated the passive gamma signature of a solid metal highly enriched uranium sphere. In addition, the mass reduction (i.e., of the 235 U) minimized logistical costs (security, criticality safety, radiological safety and transportation requirements). Radiation signature training device sources expand on the original concept, redesigning the encapsulation in a modular fashion that allows a variety of loadings. The result is a reconfigurable special nuclear material source set that can vary greatly in the magnitude of the gamma flux and the isotopic distribution. Use of the source to test a variety of standards (N42.34-2015, N42.38-2015, N42.43-2015, N42.53-2018, N42.48-2018, DHS-TCS Backpack Based Radiation Detection Systems, DHS-TCS Handheld Instruments Used for the Detection and Identification of Radionuclides, DHS-TCS Vehicle Mounted Mobile Systems) will be discussed.

Blessinger, Christopher S.↗

Excessive radon-based radiation in indoor air caused by soil building materials in traditional homes on Đồng Văn karst plateau, northern Vietnam

Radon-based radiation from natural soil building materials is an important factor likely influencing residents’ health as a contributing source of natural radiation. This work aims to quantify the nuclide-specific α-radiation of isotopes 222 Rn and 220 Rn in common types of houses in a region of northern Vietnam, Ɖông Văn karst plateau, to preliminarily (i) evaluate the total annual effective dose rates and (ii) assess the relative risk of cancer induction from indoor α-radiation for inhabitants. The average 222 Rn concentrations in all house types were lower than 100 Bq m -3 , but 220 Rn abundances were far higher than 222 Rn, even up to >1000 Bq m -3 in air close to a wall of unfired-soil bricks. The estimated total annual effective dose rates from indoor 222 Rn and 220 Rn and their progenies to residents with daily exposure of 13 h in the various types of houses range from 3.1 to 4.3 mSv a -1 for houses constructed with modified materials, but up to higher than 6 mSv a -1 in houses with raw building materials. The average risk of developing lung cancer as a consequence of a lifetime exposure to indoor α-radiation in affected homes ranges from 3.9% to 14.6%. 220 Rn and its metallic progenies contribute more than 80% of the total average lung cancer risk from total radon, being responsible for a range of 2.7–14.6% of the risk of developing lung cancer.

54 ENVIRONMENTAL SCIENCES↗

The LLNL rabbit: determination of trace element levels in polyethylene

Rabbit facilities are systems that pneumatically transport a sample carrier (known as a rabbit) to and from a radiation source. However, trace impurities in the polyethylene (PE) rabbit may interfere with measurements of short-lived isotopes. Activated impurities with short half-lives as 28 Al interfere with the fission product γ-ray, therefore the rabbit cannot be measured immediately. Neutron activation analysis was performed on various PE samples obtained from different manufacturers and the highest quality PE was used to fabricate a high-purity PE rabbit. Here, the impurities identified in the PE study were 27 Al, 48 Ca, 37 Cl, 50 Cr, 65 Cu, 127 I, 26 Mg, 55 Mn, and 30 Si.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Fixed-Energy Response-Function Analysis with Multi-Efficiency (FRAM) Software, Version 6

Researchers at Los Alamos National Laboratory have developed FixedEnergy Response- Function Analysis with Multiple Efficiency (FRAM), a powerful software tool for gamma-ray spectrometry isotopic analysis. This tool leverages Los Alamos expertise in nuclear safeguards, radiation detection systems, and related analysis techniques. A household name in the non-destructive assay community for over two decades, FRAM determines a special nuclear material source's isotopic composition by analyzing gamma-ray spectra. Los Alamos researchers have released the latest version of FRAM that incorporates several updates to the 2013 major release of FRAM, Version 5.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Detection of Isotopes in Urban Source Search Low-Count Gamma Spectra Using Hopfield Neural Networks

Source search campaigns involve measurements of background gamma-ray spectra with a mobile detector-spectrometer traveling along arbitrarily chosen trajectories over a wide screening area. Radiation counts are typically measured with a tellurium-doped sodium iodide [NaI(Tl)] scintillator detector-spectrometer in short acquisition intervals, usually 1 s. The objective is to detect orphan isotopes with half-lives shorter than those of the isotopes in the natural background. In principle, radioisotopes can be identified by their unique gamma emission spectrum. However, detecting orphan isotopes in search data is challenging because low counts measured in short acquisition intervals result in incomplete spectral lines. In this study, we investigate the performance of a Hopfield neural network (HNN) that implements an auto-associative memory for the detection of isotopes of interest in an urban search campaign. The HNN is trained on one example of gamma spectra with well-resolved spectral lines of each isotope of interest. During testing, the auto-associative memory implementation of the HNN processes low-count gamma spectra with partially complete isotopic lines by matching incoming measurements to the closest one of its memory-stored patterns. The testing database consisted of almost 10 000 1-s gamma spectra, including measurements of orphan isotopes 137 Cs, 241 Am, and 131 I, obtained during two urban search surveys with a NaI(Tl) detector. The performance of the HNN detection algorithm was evaluated using precision, recall, and F1 scores, and benchmarked with a multiple linear regression (MLR) identification algorithm. In conclusion, the test results demonstrate that HNN outperforms MLR in the detection of all the isotopes of interest.

Auto associative memory↗

PM2.5 Active Aerosol Collection Field Campaign Report

The long-range transport of aerosols can affect local air quality as well as contribute elements and constituents to mountain watersheds that have potentially positive (e.g., nitrate) and negative (e.g., heavy metals) effects to the local ecosystem. Isotopic analysis of aerosols can be a powerful tool for deconvolving the relative contributions of far-distant and local sources to the composition of collected aerosols. Our field campaign involved the week-long collection of PM2.5 (i.e., particulate matter with an aerodynamic diameter of about 2.5 microns) aerosols on filters, which were returned to the laboratories at Lawrence Berkeley National Laboratory (LBNL) for analysis. The sampling sites were located at the Gothic, Colorado Surface Atmosphere Integrated Field Laboratory (SAIL) Atmospheric Radiation Measurement (ARM) and the Mt. Crested Butte, Colorado SAIL ARM sites. The original intention was to measure the lead (Pb) and strontium (Sr) isotopic compositions of the collected aerosols at high precision to provide constraints on source portioning and attribution, as well as analyze the chemical compositions and nitrogen and carbon isotopic compositions. However, severe blank issues arose that prevented the planned isotopic analyses of Sr, Pb, C, and N and severely affected the analyses of the bulk chemical compositions of the collected aerosols, resulting in the failure of the study. The issue is described in Section 2.0.

54 ENVIRONMENTAL SCIENCES↗

Connecting radiation-driven changes in structural, thermal, and mechanical properties in several medical device polymers

Stemming from security threats and shortages in supply, a recent push has emerged to develop alternatives to radioisotope Cobalt-60 gamma radiation for sterilization of polymeric medical products, including electron beam (e-beam) and X-ray machine-based sources. However, before large-scale implementation, the effects of these non-isotope-based methods must be thoroughly investigated from several perspectives, involving their potential detrimental effects on the structural, thermal, and mechanical properties of polymers in medical devices. This paper investigates such effects in commonly used medical device polymers, including polypropylene homopolymer (PPH), polyolefin elastomer (POE), low-density polyethylene (LDPE), acrylonitrile butadiene styrene (ABS), and chlorobutyl rubber (CIIR). To connect radiation-driven changes in polymer structural and thermal properties and corresponding changes in mechanical properties, several characterization techniques were utilized, including gel permeation chromatography (GPC), Fourier transform infrared spectroscopy (FTIR), dynamic mechanical analysis (DMA) and differential scanning calorimetry (DSC). We found that the tensile strength of X-ray irradiated PPH, as well as X-ray, e-beam, and gamma irradiated CIIR decreases due to chain scission, which is corroborated by GPC and DMA. The GPC results of LDPE suggest chain scission, but interestingly without a corresponding decline in tensile strength. By comparison, POE and ABS appear to undergo further crosslinking with increasing irradiation dose, which generally strengthens them. Importantly, in the vast majority of the cases, there were small to no changes in properties upon changing radiation technologies (at a given dose), i.e., no radiation source dependence. However, in a few specific cases, radiation method dependencies did arise, for instance, in terms of the molecular weight of PPH being significantly increased upon X-ray irradiation, while the melting temperature, glass transition temperature, and elongation at break reduced compared to gamma. Overall, this study provides valuable insight into radiation-driven chemical and structural changes in polymers that produce changes in physical and functional properties.

36 MATERIALS SCIENCE↗

From Count Rates to Quantifying Isotopic Activities – Field Analysis of Radiation Monitoring Data

The Nevada National Security Site (NNSS) provides a comprehensive bicoastal radiological and nuclear emergency response to United States Department of Energy/National Nuclear Security Administration. A major part of the support is to provide systematic radiological search for lost or stolen sources, Radiological search is a core competency of the NNSS with its origin dating back to nuclear weapons test era. Search operations from multiple platforms is the common thread among the various NNSS assets, which include Aerial Measuring System (AMS), Maritime Support Team (MST), National Capitol Response (NCR), National Search Team (NST) and Radiological Assistance Program (RAP). Information collected and analyzed during search operations add to the actionable intelligence for the law enforcement agencies and provide valuable guidance for the tactical resolution of a nuclear or radiological crisis. Search is an intelligence and situational awareness driven operation and most often called upon during a radiological emergency, however it can be brought into play to thwart a potential threat by providing monitoring and surveillance support. The Office of Nuclear Incident Response (NA-84) serves as the technical leader in responding to and resolving nuclear and radiological threats worldwide and integrates its efforts with other NNSA stakeholders (e.g., NNSA office of Defense Nuclear Non-proliferation NA-22). The response includes expertise in the areas of radiological search, render safe, and consequence management. This article will discuss the methodologies, tools, procedures, and techniques to extract maximum radiological characterization information (isotopic composition, activities for individual isotopes, threat assessment etc.) from field monitoring or Search operation data.

61 RADIATION PROTECTION AND DOSIMETRY↗

Oak Ridge National Laboratory Shutdown Dose Rate Code Suite

The Oak Ridge National Laboratory (ORNL) shutdown dose rate (SDDR) code suite calculates gamma dose rates at a location of interest due to activation of materials. The code suite is based on the rigorous two-step (R2S) method that involves two radiation transport calculations: (1) neutron radiation transport to determine neutron fluxes in the material for which activation calculations will be performed and (2) gamma radiation transport to determine dose rates at a location of interest, due to material activation. The ORNL SDDR code suite is used to determine an importance function that characterizes the neutron’s importance to the final SDDR when the Monte Carlo radiation transport method is used. This report demonstrates how the ORNL SDDR code suite is implemented through the following codes: Monte Carlo N-Particle (MCNP) code Version 5-1.60, Oak Ridge Isotope Generator (ORIGEN), MSX suite of utilities, Neutron Activation Gamma Source Sampler (NAGSS), and Automated Variance Reduction Generator (ADVANTG). For this demonstration, the International Thermonuclear Experimental Reactor (ITER) SDDR benchmark problem is used and the dose rate result is compared to previously published work.

61 RADIATION PROTECTION AND DOSIMETRY↗

Measurement of the 230 Th( p ,2n)Pa229 and 230 Th( p ,3n)Pa228 reaction cross sections from 14.1 to 16.9 MeV

Actinium-225 is of interest for medical isotope production and there is on-going research into methods of producing Ac 225 , either directly or via the decay of its parent isotopes ( Th 229 , Pa 229 , and Ra 225 ). One method that has been suggested is the Th 230 ( p , 2 n ) Pa 229 reaction. However, there is no available cross-section data for this reaction in the literature. Purpose: Measure the Th 230 ( p , 2 n ) and Th 230 ( p , 3 n ) reaction cross sections in the energy range where the ( p , 2 n ) reaction is predicted to peak to determine the feasibility of Ac 225 production via the Th 230 ( p , 2 n ) reaction. Methods: Targets naturally enriched in Th 230 were irradiated at the Center for Accelerator Mass Spectrometry at Lawrence Livermore National Laboratory with energies ranging from 14.1 to 16.9 MeV. Furthermore, chemical processing was used to separate the protactinium activation products, followed by γ -ray spectroscopy to measure the activities of Pa 228 , 229 , 230 , 232 produced in the irradiation. Results: We find that excitation functions are reported for the first time in the literature for the Th 230 ( p , 2 n ) and Th 230 ( p , 3 n ) reactions in this energy range. The peak measured value of the Th 230 ( p , 2 n ) reaction was found to be 182 ± 12 mb at 14.4 ± 0.1 MeV. The Th 232 ( p , n ) Pa 232 reaction was used to verify the experimental conditions, the measured values are reported and are comparable to the existing literature values. From the γ -ray spectrometry data, the half-life of Pa 229 was measured as 1.5 ± 0.1 days, which is within the error of the half-life reported in the evaluated nuclear data as well as in the recent measurements, and the half-life of Pa 228 was measured as 19.5 ± 0.4 hours. Conclusions: Overall, the Th 230 ( p , 2 n ) Pa 229 reaction could reasonably be used for Ac 225 isotope production, although significant amounts of relatively isotopically pure Th 230 would be needed for significant production because the low alpha-decay branching ratio of Pa 229 and long half-life of Th 229 inhibit the in-growth of significant amounts of Ac 225 .

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Nuclear Interdiction Through Relocatable Detectors

The NNSA Office of Nuclear Smuggling Detection and Deterrence (NSDD) has investigated a set of minimal-infrastructure radiation detection systems as alternatives to fixed Radiation Portal Monitors (RPMs) for nuclear interdiction applications. These versatile and relocatable systems can improve nuclear security in missions or locations that do not warrant or support a standard fixed radiation detection system. Over 2019, a variety of relocatable detectors were characterized at the Interdiction Technologies Integration Laboratory at Pacific Northwest National Laboratory (PNNL). Evaluated detectors were diverse in their size and capabilities, ranging from backpack-sized systems to lane-spanning cargo scanning portals. Both spectroscopic and non-spectroscopic pedestrian and vehicle detection systems were characterized against uranium and plutonium sources. Signatures from the sources were modulated by both shielding and distance to quantify the performance of the relocatable systems as signal strength was decreased. Findings showed that relocatable spectroscopic detectors with isotope identification capabilities could reduce nuisance alarm rates compared to conventional fixed installation, gross-counting, radiation portal monitors. In vehicle scanning applications, detection ability generally trended with detection volume, regardless of spectral capability. In pedestrian scanning applications, several smaller backpack-sized detector systems were found to be more sensitive to detecting material than pedestrian portal monitors. The results of this characterization effort have helped inform the deployment of versatile equipment to improve nuclear security missions.

relocatable detectors, Nuclear Security↗

Photonuclear Physics in SCALE

Radiation shielding modeling involves a wide range of applications, such as power reactors, critical experiments, portable sources, linear accelerators, and fusion systems. Particle energy ranges vary from thermal energies to fast energy spectra. MAVRIC, as the radiation shielding sequence of the SCALE code system [1] developed and maintained by Oak Ridge National Laboratory, is capable of modeling both neutron and photon interactions in matter and is widely used by the US Nuclear Regulatory Commission, Department of Energy, the National Nuclear Security Administration, and radiation shielding practitioners all around the world. Although most applications don’t involve highly energetic photons that can cause photonuclear reactions and create coupled chains of high energy, ionized electrons and bremsstrahlung radiation within a material medium, when present, these reactions can have a significant impact upon the downstream particle fluxes from incident photons above 20 MeV. For example, linear accelerators used for medical isotope production are examples of applications in which high-energetic photons are generated and used for driving or controlling other components of a complex facility. Radiation shielding analyses of such a facility would require accounting for any and all significant sources of radiation. Unfortunately, MAVRIC included no data and methods to model either photonuclear reactions or the bremsstrahlung photons until this work, which enabled accounting for both. Photonuclear reaction cross sections were imported from the Evaluated Nuclear Data File libraries, and corresponding methods were implemented in the SCALE code system; see Section 2 for how the nuclear data are imported and used. Bremsstrahlung photons were modeled by assuming thick-target approximation whereby all generated electrons and positrons due to photon interactions are assumed to be absorbed within the same material in which they were born, yielding a quick particle transport simulation method by using fast lookup tables for generating subsequent gammas; see Section 4 for details. A suite of verification models was used to test implemented methods and associated data. Tests yielded satisfactory results for the new features. Enhancements will be released as part of the next major SCALE release (v7.0), which is anticipated to be deployed in 2025, with beta releases available in the interim.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Analysis of FRAM Measurements to Establish Methodology Uncertainty

Qualification measurements were performed at Oak Ridge National Laboratory (ORNL) on a variety of measurement standards. These measurements will be used to qualify the Fixed-Energy, Response Function Analysis with Multiple Efficiency (FRAM) code with a high purity germanium (HPGe) detector for use at ORNL. Measured items include uranium isotopic standards, U 3 O 8 line sources, and a uranium tetrafluoride source. The 235 U enrichment was estimated using the FRAM isotopic analysis software for each source and compared with the declared isotopic values.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Semi-empirical simulation of in-motion radiation detection systems

The Replicative Assessment of Spectroscopic Equipment (RASE) is an open-source software that uses experimental data as the basis to simulate the response of commercial radiation detectors to sources in various situations, particularly in the context of nuclear security and safeguards applications. Dynamic RASE introduces the capability to simulate scenarios where sources and detector are in relative motion. Position-dependent experimentally acquired gamma spectra are ingested by Dynamic RASE to build maps that describe the detector response over all space. These response maps are used to replicate the time-dependent energy spectra collected as sources move on a path near the detector. Here, a Gaussian process is used to build each map, incorporating a novel kernel adapted to the special case of radiation detection. The approach has been validated against experimental data acquired using a NaI-based detector for 137 Cs and 54 Mn sources. The capability to create accurate simulations using either long-dwell static measurements or dynamic pass-by measurements as source data has been demonstrated. Quantitative relative performance, benefits, and shortcomings are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗