Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Image reconstruction techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Identifying Neutrino Final States and Energies in MicroBooNE with New Deep-Learning Based LArTPC Reconstruction Frameworks

MicroBooNE, a Liquid Argon Time Projection Chamber (LArTPC) located in the $\nu_{\mu}$-dominated Booster Neutrino Beam at Fermilab, has been studying $\nu_{e}$ charged-current (CC) interaction rates to shed light on the MiniBooNE low energy excess. The LArTPC technology employed by MicroBooNE provides the capability to image neutrino interactions with mm-scale precision. Computer vision and other machine learning techniques are promising tools for image processing that could boost efficiencies for selecting $\nu_{e}$-CC and other rare signals, reduce cosmic and beam-induced backgrounds, and improve the reconstruction of neutrino energies. The MicroBooNE experiment has been at the forefront of developing and testing such techniques for use in physics analyses. In this poster we overview deep-learning based reconstruction methods. We will showcase the use of a recurrent neural network to estimate neutrino energies and present a new reconstruction framework that uses convolutional neural networks to locate neutrino interaction vertices, tag pixels with track and shower labels, and perform particle identification on reconstructed clusters. We will present studies characterizing the performance of these new tools and demonstrate their effectiveness through their use in an inclusive $\nu_{e}$-CC event selection.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Identifying Neutrino Final States and Energies in MicroBooNE with New Deep-Learning Based LArTPC Reconstruction Frameworks

MicroBooNE, a Liquid Argon Time Projection Chamber (LArTPC) located in the $\nu_{\mu}$-dominated Booster Neutrino Beam at Fermilab, has been studying $\nu_{e}$ charged-current (CC) interaction rates to shed light on the MiniBooNE low energy excess. The LArTPC technology employed by MicroBooNE provides the capability to image neutrino interactions with mm-scale precision. Computer vision and other machine learning techniques are promising tools for image processing that could boost efficiencies for selecting $\nu_{e}$-CC and other rare signals, reduce cosmic and beam-induced backgrounds, and improve the reconstruction of neutrino energies. The MicroBooNE experiment has been at the forefront of developing and testing such techniques for use in physics analyses. In this poster we overview deep-learning based reconstruction methods. We will showcase the use of a recurrent neural network to estimate neutrino energies and present a new reconstruction framework that uses convolutional neural networks to locate neutrino interaction vertices, tag pixels with track and shower labels, and perform particle identification on reconstructed clusters. We will present studies characterizing the performance of these new tools and demonstrate their effectiveness through their use in an inclusive $\nu_{e}$-CC event selection.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

GPU-based fast cone beam CT reconstruction from undersampled and noisy projection data via total variation

Purpose: Cone-beam CT (CBCT) plays an important role in image guided radiation therapy (IGRT). However, the large radiation dose from serial CBCT scans in most IGRT procedures raises a clinical concern, especially for pediatric patients who are essentially excluded from receiving IGRT for this reason. The goal of this work is to develop a fast GPU-based algorithm to reconstruct CBCT from undersampled and noisy projection data so as to lower the imaging dose. Methods: The CBCT is reconstructed by minimizing an energy functional consisting of a data fidelity term and a total variation regularization term. The authors developed a GPU-friendly version of the forward-backward splitting algorithm to solve this model. A multigrid technique is also employed. Results: It is found that 20-40 x-ray projections are sufficient to reconstruct images with satisfactory quality for IGRT. The reconstruction time ranges from 77 to 130 s on an NVIDIA Tesla C1060 (NVIDIA, Santa Clara, CA) GPU card, depending on the number of projections used, which is estimated about 100 times faster than similar iterative reconstruction approaches. Moreover, phantom studies indicate that the algorithm enables the CBCT to be reconstructed under a scanning protocol with as low as 0.1 mA s/projection. Comparing with currently widely used full-fan head and neck scanning protocol of {approx}360 projections with 0.4 mA s/projection, it is estimated that an overall 36-72 times dose reduction has been achieved in our fast CBCT reconstruction algorithm. Conclusions: This work indicates that the developed GPU-based CBCT reconstruction algorithm is capable of lowering imaging dose considerably. The high computation efficiency in this algorithm makes the iterative CBCT reconstruction approach applicable in real clinical environments.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Bulk properties of honeycomb lattices of superconducting microwave resonators

We have realized different honeycomb lattices for microwave photons in the 4 to 8 GHz band using superconducting spiral resonators. Each lattice comprises a few hundred sites. Two designs have been studied, one leading to two bands touching at the Dirac points and one where a gap opens at the Dirac points. Using a scanning laser technique to image the eigenmodes of this new type of photonic lattices, we are able to reconstruct their band structure. The measured bands are in excellent agreement with ab initio models that combine numerical simulations of the electromagnetic properties of the spiral resonator and analytical calculations.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Three-Dimensional Reconstruction and Microstructure Modeling of Porosity-Graded Cathode Using Focused Ion Beam and Homogenization Techniques

In this study, microstructure of a porosity-graded lanthanum strontium manganite (LSM) cathode of solid oxide fuel cells (SOFCs) has been characterized using focused ion beam (FIB) and scanning electron microscopy(SEM) combined with image processing. Two-point correlation functions of the two-dimensional (2D) images taken along the direction of porosity gradient are used to reconstruct a three-dimensional (3D) microstructure. The effective elastic modulus of the two-phase porosity-graded cathode is predicted using strong contrast (SC) and composite inclusion (CI) homogenization techniques. The effectiveness of the two methods in predicting the effective elastic properties of the porositygraded LSM cathode is investigated in comparison with the results obtained from the finite element model (FEM).

25 ENERGY STORAGE↗

Seeing in with X-rays: 4D Strain and Thermometry Measurements for Thermal-Mechanical Testing

Understanding temperature-dependent material decomposition and structural deformation induced by combined thermal-mechanical environments is critical for safety qualification of hardware under accident scenarios. Seeing in with X-rays elucidated the physics necessary to develop X-ray strain and thermometry diagnostics for use in optically opaque environments. Two parallel thermometry schemes were explored: X-ray fluorescence and X-ray diffraction of inorganic doped ceramics– colloquially known as thermographic phosphors. Two parallel surface strain techniques–Path-Integrated Digital Image Correlation and Frequency Multiplexed Digital Image Correlation–were demonstrated. Finally, preliminary demonstration of time-resolved digital volume correlation was performed by taking advantage of limited view reconstruction techniques. Additionally, research into blended ceramic-metal coatings was critical to generating intrinsic thermographic patterns for the future combination of X-ray strain and thermometry measurements.

36 MATERIALS SCIENCE↗

WE-AB-303-09: Rapid Projection Computations for On-Board Digital Tomosynthesis in Radiation Therapy

Purpose: To facilitate fast and accurate iterative volumetric image reconstruction from limited-angle on-board projections. Methods: Intrafraction motion hinders the clinical applicability of modern radiotherapy techniques, such as lung stereotactic body radiation therapy (SBRT). The LIVE system may impact clinical practice by recovering volumetric information via Digital Tomosynthesis (DTS), thus entailing low time and radiation dose for image acquisition during treatment. The DTS is estimated as a deformation of prior CT via iterative registration with on-board images; this shifts the challenge to the computational domain, owing largely to repeated projection computations across iterations. We address this issue by composing efficient digital projection operators from their constituent parts. This allows us to separate the static (projection geometry) and dynamic (volume/image data) parts of projection operations by means of pre-computations, enabling fast on-board processing, while also relaxing constraints on underlying numerical models (e.g. regridding interpolation kernels). Further decoupling the projectors into simpler ones ensures the incurred memory overhead remains low, within the capacity of a single GPU. These operators depend only on the treatment plan and may be reused across iterations and patients. The dynamic processing load is kept to a minimum and maps well to the GPU computational model. Results: We have integrated efficient, pre-computable modules for volumetric ray-casting and FDK-based back-projection with the LIVE processing pipeline. Our results show a 60x acceleration of the DTS computations, compared to the previous version, using a single GPU; presently, reconstruction is attained within a couple of minutes. The present implementation allows for significant flexibility in terms of the numerical and operational projection model; we are investigating the benefit of further optimizations and accurate digital projection sub-kernels. Conclusion: Composable projection operators constitute a versatile research tool which can greatly accelerate iterative registration algorithms and may be conducive to the clinical applicability of LIVE. National Institutes of Health Grant No. R01-CA184173; GPU donation by NVIDIA Corporation.

60 APPLIED LIFE SCIENCES↗

Study of azimuthal anisotropy of $\Upsilon$ (1S) mesons in pPb collisions at $\sqrt{S_{NN}}$ = 8.16 TeV

The azimuthal anisotropy of Image 1 mesons in high-multiplicity proton-lead collisions is studied using data collected by the CMS experiment at a nucleon-nucleon center-of-mass energy of 8.16 TeV. The Image 1 mesons are reconstructed using their dimuon decay channel. The anisotropy is characterized by the second Fourier harmonic coefficients, found using a two-particle correlation technique, in which the Image 1 mesons are correlated with charged hadrons. A large pseudorapidity gap is used to suppress short-range correlations. Nonflow contamination from the dijet background is removed using a low-multiplicity subtraction method, and the results are presented as a function of Image 1 transverse momentum. The azimuthal anisotropies are smaller than those found for charmonia in proton-lead collisions at the same collision energy, but are consistent with values found for Image 1 mesons in lead-lead interactions at a nucleon-nucleon center-of-mass energy of 5.02 TeV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

TU-EF-204-02: Hiigh Quality and Sub-MSv Cerebral CT Perfusion Imaging

Purpose: CT Perfusion (CTP) imaging is of great importance in acute ischemic stroke management due to its potential to detect hypoperfused yet salvageable tissue and distinguish it from definitely unsalvageable tissue. However, current CTP imaging suffers from poor image quality and high radiation dose (up to 5 mSv). The purpose of this work was to demonstrate that technical innovations such as Prior Image Constrained Compressed Sensing (PICCS) have the potential to address these challenges and achieve high quality and sub-mSv CTP imaging. Methods: (1) A spatial-temporal 4D cascaded system model was developed to indentify the bottlenecks in the current CTP technology; (2) A task-based framework was developed to optimize the CTP system parameters; (3) Guided by (1) and (2), PICCS was customized for the reconstruction of CTP source images. Digital anthropomorphic perfusion phantoms, animal studies, and preliminary human subject studies were used to validate and evaluate the potentials of using these innovations to advance the CTP technology. Results: The 4D cascaded model was validated in both phantom and canine stroke models. Based upon this cascaded model, it has been discovered that, as long as the spatial resolution and noise properties of the 4D source CT images are given, the 3D MTF and NPS of the final CTP maps can be analytically derived for a given set of processing methods and parameters. The cascaded model analysis also identified that the most critical technical factor in CTP is how to acquire and reconstruct high quality source images; it has very little to do with the denoising techniques often used after parametric perfusion calculations. This explained why PICCS resulted in a five-fold dose reduction or substantial improvement in image quality. Conclusion: Technical innovations generated promising results towards achieving high quality and sub-mSv CTP imaging for reliable and safe assessment of acute ischemic strokes. K. Li, K. Niu, Y. Wu: Nothing to disclose. G.-H. Chen: Research funded, GE Healthcare; Research funded, Siemens AX.

60 APPLIED LIFE SCIENCES↗

MO-DE-209-04: Radiation Dosimetry in Breast Tomosynthesis

Digital Breast Tomosynthesis (DBT) is rapidly replacing mammography as the standard of care in breast cancer screening and diagnosis. DBT is a form of computed tomography, in which a limited set of projection images are acquired over a small angular range and reconstructed into tomographic data. The angular range varies from 15° to 50° and the number of projections varies between 9 and 25 projections, as determined by the equipment manufacturer. It is equally valid to treat DBT as the digital analog of classical tomography – that is, linear tomography. In fact, the name “tomosynthesis” stands for “synthetic tomography.” DBT shares many common features with classical tomography, including the radiographic appearance, dose, and image quality considerations. As such, both the science and practical physics of DBT systems is a hybrid between computed tomography and classical tomographic methods. In this lecture, we will explore the continuum from radiography to computed tomography to illustrate the characteristics of DBT. This lecture will consist of four presentations that will provide a complete overview of DBT, including a review of the fundamentals of DBT acquisition, a discussion of DBT reconstruction methods, an overview of dosimetry for DBT systems, and summary of the underlying image theory of DBT thereby relating image quality and dose. Learning Objectives: To understand the fundamental principles behind tomosynthesis image acquisition. To understand the fundamentals of tomosynthesis image reconstruction. To learn the determinants of image quality and dose in DBT, including measurement techniques. To learn the image theory underlying tomosynthesis, and the relationship between dose and image quality. ADM is a consultant to, and holds stock in, Real Time Tomography, LLC. ADM receives research support from Hologic Inc., Analogic Inc., and Barco NV.; ADM is a member of the Scientific Advisory Board for Gamma Medica Inc.; A. Maidment, Research Support, Hologic, Inc.; Research Support, Barco, Inc.; Scientific Advisory Board, Gamma Medica, Inc.; Scientific Advisory Board, Real-Time Tomography, LLC.; Shareholder, Real-Time Tomography, LLC; J. Mainprize, Our lab has a research agreement with GE Healthcare on various topics in digital mammography and digital tomosynthesis; W. Zhao, Research grant from Siemens Health Care.

60 APPLIED LIFE SCIENCES↗

MO-DE-209-00: DBT Physics Basic to Advanced

Digital Breast Tomosynthesis (DBT) is rapidly replacing mammography as the standard of care in breast cancer screening and diagnosis. DBT is a form of computed tomography, in which a limited set of projection images are acquired over a small angular range and reconstructed into tomographic data. The angular range varies from 15° to 50° and the number of projections varies between 9 and 25 projections, as determined by the equipment manufacturer. It is equally valid to treat DBT as the digital analog of classical tomography – that is, linear tomography. In fact, the name “tomosynthesis” stands for “synthetic tomography.” DBT shares many common features with classical tomography, including the radiographic appearance, dose, and image quality considerations. As such, both the science and practical physics of DBT systems is a hybrid between computed tomography and classical tomographic methods. In this lecture, we will explore the continuum from radiography to computed tomography to illustrate the characteristics of DBT. This lecture will consist of four presentations that will provide a complete overview of DBT, including a review of the fundamentals of DBT acquisition, a discussion of DBT reconstruction methods, an overview of dosimetry for DBT systems, and summary of the underlying image theory of DBT thereby relating image quality and dose. Learning Objectives: To understand the fundamental principles behind tomosynthesis image acquisition. To understand the fundamentals of tomosynthesis image reconstruction. To learn the determinants of image quality and dose in DBT, including measurement techniques. To learn the image theory underlying tomosynthesis, and the relationship between dose and image quality. ADM is a consultant to, and holds stock in, Real Time Tomography, LLC. ADM receives research support from Hologic Inc., Analogic Inc., and Barco NV.; ADM is a member of the Scientific Advisory Board for Gamma Medica Inc.; A. Maidment, Research Support, Hologic, Inc.; Research Support, Barco, Inc.; Scientific Advisory Board, Gamma Medica, Inc.; Scientific Advisory Board, Real-Time Tomography, LLC.; Shareholder, Real-Time Tomography, LLC; J. Mainprize, Our lab has a research agreement with GE Healthcare on various topics in digital mammography and digital tomosynthesis; W. Zhao, Research grant from Siemens Health Care.

60 APPLIED LIFE SCIENCES↗

MO-DE-209-01: Primer On Tomosynthesis

Digital Breast Tomosynthesis (DBT) is rapidly replacing mammography as the standard of care in breast cancer screening and diagnosis. DBT is a form of computed tomography, in which a limited set of projection images are acquired over a small angular range and reconstructed into tomographic data. The angular range varies from 15° to 50° and the number of projections varies between 9 and 25 projections, as determined by the equipment manufacturer. It is equally valid to treat DBT as the digital analog of classical tomography – that is, linear tomography. In fact, the name “tomosynthesis” stands for “synthetic tomography.” DBT shares many common features with classical tomography, including the radiographic appearance, dose, and image quality considerations. As such, both the science and practical physics of DBT systems is a hybrid between computed tomography and classical tomographic methods. In this lecture, we will explore the continuum from radiography to computed tomography to illustrate the characteristics of DBT. This lecture will consist of four presentations that will provide a complete overview of DBT, including a review of the fundamentals of DBT acquisition, a discussion of DBT reconstruction methods, an overview of dosimetry for DBT systems, and summary of the underlying image theory of DBT thereby relating image quality and dose. Learning Objectives: To understand the fundamental principles behind tomosynthesis image acquisition. To understand the fundamentals of tomosynthesis image reconstruction. To learn the determinants of image quality and dose in DBT, including measurement techniques. To learn the image theory underlying tomosynthesis, and the relationship between dose and image quality. ADM is a consultant to, and holds stock in, Real Time Tomography, LLC. ADM receives research support from Hologic Inc., Analogic Inc., and Barco NV.; ADM is a member of the Scientific Advisory Board for Gamma Medica Inc.; A. Maidment, Research Support, Hologic, Inc.; Research Support, Barco, Inc.; Scientific Advisory Board, Gamma Medica, Inc.; Scientific Advisory Board, Real-Time Tomography, LLC.; Shareholder, Real-Time Tomography, LLC; J. Mainprize, Our lab has a research agreement with GE Healthcare on various topics in digital mammography and digital tomosynthesis; W. Zhao, Research grant from Siemens Health Care.

60 APPLIED LIFE SCIENCES↗

MO-DE-209-02: Tomosynthesis Reconstruction Methods

Digital Breast Tomosynthesis (DBT) is rapidly replacing mammography as the standard of care in breast cancer screening and diagnosis. DBT is a form of computed tomography, in which a limited set of projection images are acquired over a small angular range and reconstructed into tomographic data. The angular range varies from 15° to 50° and the number of projections varies between 9 and 25 projections, as determined by the equipment manufacturer. It is equally valid to treat DBT as the digital analog of classical tomography – that is, linear tomography. In fact, the name “tomosynthesis” stands for “synthetic tomography.” DBT shares many common features with classical tomography, including the radiographic appearance, dose, and image quality considerations. As such, both the science and practical physics of DBT systems is a hybrid between computed tomography and classical tomographic methods. In this lecture, we will explore the continuum from radiography to computed tomography to illustrate the characteristics of DBT. This lecture will consist of four presentations that will provide a complete overview of DBT, including a review of the fundamentals of DBT acquisition, a discussion of DBT reconstruction methods, an overview of dosimetry for DBT systems, and summary of the underlying image theory of DBT thereby relating image quality and dose. Learning Objectives: To understand the fundamental principles behind tomosynthesis image acquisition. To understand the fundamentals of tomosynthesis image reconstruction. To learn the determinants of image quality and dose in DBT, including measurement techniques. To learn the image theory underlying tomosynthesis, and the relationship between dose and image quality. ADM is a consultant to, and holds stock in, Real Time Tomography, LLC. ADM receives research support from Hologic Inc., Analogic Inc., and Barco NV.; ADM is a member of the Scientific Advisory Board for Gamma Medica Inc.; A. Maidment, Research Support, Hologic, Inc.; Research Support, Barco, Inc.; Scientific Advisory Board, Gamma Medica, Inc.; Scientific Advisory Board, Real-Time Tomography, LLC.; Shareholder, Real-Time Tomography, LLC; J. Mainprize, Our lab has a research agreement with GE Healthcare on various topics in digital mammography and digital tomosynthesis; W. Zhao, Research grant from Siemens Health Care.

60 APPLIED LIFE SCIENCES↗

MO-DE-209-03: Assessing Image Quality

Digital Breast Tomosynthesis (DBT) is rapidly replacing mammography as the standard of care in breast cancer screening and diagnosis. DBT is a form of computed tomography, in which a limited set of projection images are acquired over a small angular range and reconstructed into tomographic data. The angular range varies from 15° to 50° and the number of projections varies between 9 and 25 projections, as determined by the equipment manufacturer. It is equally valid to treat DBT as the digital analog of classical tomography – that is, linear tomography. In fact, the name “tomosynthesis” stands for “synthetic tomography.” DBT shares many common features with classical tomography, including the radiographic appearance, dose, and image quality considerations. As such, both the science and practical physics of DBT systems is a hybrid between computed tomography and classical tomographic methods. In this lecture, we will explore the continuum from radiography to computed tomography to illustrate the characteristics of DBT. This lecture will consist of four presentations that will provide a complete overview of DBT, including a review of the fundamentals of DBT acquisition, a discussion of DBT reconstruction methods, an overview of dosimetry for DBT systems, and summary of the underlying image theory of DBT thereby relating image quality and dose. Learning Objectives: To understand the fundamental principles behind tomosynthesis image acquisition. To understand the fundamentals of tomosynthesis image reconstruction. To learn the determinants of image quality and dose in DBT, including measurement techniques. To learn the image theory underlying tomosynthesis, and the relationship between dose and image quality. ADM is a consultant to, and holds stock in, Real Time Tomography, LLC. ADM receives research support from Hologic Inc., Analogic Inc., and Barco NV.; ADM is a member of the Scientific Advisory Board for Gamma Medica Inc.; A. Maidment, Research Support, Hologic, Inc.; Research Support, Barco, Inc.; Scientific Advisory Board, Gamma Medica, Inc.; Scientific Advisory Board, Real-Time Tomography, LLC.; Shareholder, Real-Time Tomography, LLC; J. Mainprize, Our lab has a research agreement with GE Healthcare on various topics in digital mammography and digital tomosynthesis; W. Zhao, Research grant from Siemens Health Care.

60 APPLIED LIFE SCIENCES↗

A Mobile Automated Tomographic Gamma Scanning System - 13231

Canberra Industries have recently designed and built a new automated Tomographic Gamma Scanning (TGS) system for mobile deployment. The TGS technique combines high-resolution gamma spectroscopy with low spatial resolution 3-dimensional image reconstruction to provide increased accuracy over traditional approaches for the assay of non-uniform source distributions in low-to medium-density, non-heterogeneous matrices. Originally pioneered by R. Estep at Los Alamos National Laboratory (LANL), the TGS method has been further developed and commercialized by Canberra Industries in recent years. The present system advances the state of the art on several fronts: it is designed to be housed in a standard cargo transport container for ease of transport, allowing waste characterization at multiple facilities under the purview of a single operator. Conveyor feed, drum rotator, and detector and collimator positioning mechanisms operated by programmable logic control (PLC) allow automated batch mode operation. The variable geometry settings can accommodate a wide range of waste packaging, including but not limited to standard 220 liter drums, 380 liter overpack drums, and smaller 20 liter cans. A 20 mCi Eu-152 transmission source provides attenuation corrections for drum matrices up to 1 g/cm{sup 3} in TGS mode; the system can be operated in Segmented Gamma Scanning (SGS) mode to measure higher density drums. To support TGS assays at higher densities, the source shield is sufficient to house an alternate Co-60 transmission source of higher activity, up to 250 mCi. An automated shutter and attenuator assembly is provided for operating the system with a dual intensity transmission source. The system's 1500 kg capacity rotator turntable can handle heavy containers such as concrete lined 380 liter overpack drums. Finally, data acquisition utilizes Canberra's Broad Energy Germanium (BEGE) detector and Lynx MCA, with 32 k channels, providing better than 0.1 keV/channel resolution to support both isotopic analysis with the MGA/MGAU software and a wide 3 MeV dynamic range. The calibration and verification of the system is discussed, and quantitative results are presented for a variety of drum types and matrices. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Recent Advancements in Tomographic Gamma Scanning for Non- Destructive Assay - 17321

Canberra Industries has recently designed and built a Tomographic Gamma Scanning (TGS) system for the deployment in a nuclear facility. The TGS technique combines high-resolution gamma spectroscopy with low spatial resolution 3- dimensional image reconstruction to provide increased accuracy over traditional approaches for the assay of non-uniform source distributions in low-to medium-density containers. The TGS system has been optimized to measure 120 liter drums and has the capability to measure containers of various sizes. Canberra has incorporated numerous enhancements and improvements to the latest system in both its hardware and software components. The signal processing chain and data analysis software have been configured to use either an electronic pulser or digital signal processing (DSP) electronics for dead time corrections. In the case of using the DSP electronics, the need to calibrate and maintain a pulser can be eliminated without sacrificing any performance. For the 120 liter container, the TGS system has been calibrated and validated with three different spatial resolutions, using two collimator aperture sizes, measuring 2.54 and 1.27 cm in width. The system has also been supplied and calibrated with a wide, rectangular collimator (25.4 cm W x 10.2 cm H) for scanning containers solely in the vertical axis. The TGS system also has an automated attenuator assembly, which has the capability to use a combination of attenuators to reduce the count rate for high activity samples. An extensive measurement campaign was performed in addition to the calibration verification to evaluate the accuracy of the system using rod sources, point sources, and a variety of matrices and source distributions. Improvements to the evaluation of the total measurement uncertainty based upon these studies have been incorporated into the analysis software package. Finally, the performance of this new TGS system will be demonstrated in the context of Canberra's previous TGS systems, including several 208 liter-based systems and a smaller, 20 liter container TGS system. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Impacts of Source Location in Tomographic Gamma Scanning - 17324

Canberra Industries has recently designed and built a Tomographic Gamma Scanning (TGS) system for the deployment in a nuclear facility. The TGS technique combines high-resolution gamma spectroscopy with low spatial resolution 3-dimensional image reconstruction to provide increased accuracy over traditional approaches for the assay of non-uniform source distributions in low-to medium-density containers. The TGS system has been optimized to measure 120 liter drums and has been equipped to use various collimators and attenuators to assay containers under a wide range of operational conditions. In this paper, we report on experimental work using TGS systems aimed at evaluating the effects of source locations at the limits of volume elements, or voxels, defined in the image reconstruction. These include sources placed at voxel boundaries within a single vertical layer and sources placed in the lowest and highest possible vertical positions within the containers. Building upon previous studies, the accuracy of the TGS system was also assessed by varying the radial position of a point source within a vertical segment. The robustness of the TGS image reconstruction algorithm to location of the sources location was also analyzed as a function of matrix density and gamma-ray energy. Methods to reduce the biases from source location at extreme positions within the container were implemented and tested. The results from this work have been used to better understand the total measurement uncertainty (TMU) and analysis methodology used in TGS systems currently deployed and under development. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ERTS image data compression technique evaluation

The author has identified the following significant results. Tapes of compressed ERTS data were obtained to permit later reconstruction and to prove that in general four ERTS MSS tapes can be put onto a single compressed tape. A compressed tape was reconstructed and imagery made. The data were compressed using the essentially information preserving SSDIAM algorithm, with mappings of from 1 to 3 levels and imagery was made of the result. This imagery shows that no visual degradation results from the one level mapping while compression is significantly increased. Mappings of up to three levels shows negligible deterioration in areas of moderate to high data activity, but contouring is noticeable in areas of uniform data such as the plains region.

Spencer, D. J.↗