Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Image Segmentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Satellite Image Algorithms

Presented by Conner Hatton at SIAM UQ Conference in Trieste, Italy, on February 27th, 2024. Conference details available online at https://www.siam.org/conferences/cm/conference/uq24

97 MATHEMATICS AND COMPUTING↗

Computer vision models and advanced TEM imaging for microstructures of irradiated AM316 stainless steels

Advancements were made in automating microscopy-based material characterization, particularly in studying irradiation effects on additively manufactured (AM) materials using machine learning (ML) and computer vision (CV). These automation efforts address the challenges of analyzing complex microstructures, accelerating the detection of irradiation-induced defects. Two CV models were developed at Argonne National Laboratory (ANL) to enhance transmission electron microscopy (TEM) analysis of irradiated AM 316 stainless steel. The first model focused on the detection of irradiation-induced dislocation loops, which contribute to material hardening and embrittlement. These loops, categorized as faulted or perfect, were automatically detected and classified using a Mask R-CNN model trained on TEM images from both in-situ and ex-situ ion irradiation experiments. The model achieved high accuracy, with precision, recall, and F1 scores of 0.839, 0.734, and 0.776, respectively, demonstrating its effectiveness in analyzing dislocation loops in irradiated AM materials. The second CV model was developed to analyze the size and wall thickness of dislocation cells in laser powder bed fusion (LPBF) 316 stainless steel. Using a U-Net++ architecture with EfficientNet as the encoder, the model was trained on TEM images to segment and measure cell size and wall thickness.

36 MATERIALS SCIENCE↗

Stochastic microstructural analysis of ceramic matrix composites using a high-fidelity multiscale framework

This paper presents a high-fidelity multiscale framework to simulate the mechanical behavior of ceramic matrix composites (CMCs), accounting for the complex micromorphology captured using detailed material characterization. First, high-resolution micrographs are obtained for the specific carbon fiber silicon-carbide-nitride matrix (C/SiNC) CMC to characterize the variability of the architectural features and manufacturing-induced defects at the microscale. An image processing algorithm is then used to precisely estimate the size and distribution of all subscale features and defects from the micrographs. The information is then used to generate a three-dimensional stochastic representative volume element (SRVE) to reconstruct microscale constituents accounting for the variability. As a result, the generated SRVEs are simulated using the high-fidelity generalized method of cells (HFGMC) micromechanics theory to investigate the effects of defects on the elastic properties of C/SiNC CMCs.

Ceramic Matrix Composites↗

A framework of computer vision-enhanced microfluidic approach for automated assessment of the transient sickling kinetics in sickle red blood cells

The occurrence of vaso-occlusive crisis greatly depends on the competition between the sickling delay time and the transit time of individual sickle cells, i.e., red blood cells from sickle cell disease (SCD) patients, while they are traversing the circulatory system. Many drugs for treating SCD work by inhibiting the polymerization of sickle hemoglobin (HbS), effectively delaying the sickling process in sickle cells (SS RBCs). Most previous studies on screening anti-sickling drugs, such as voxelotor, rely on in vitro testing of sickling characteristics, often conducted under prolonged deoxygenation for up to 1 hour. However, since the microcirculation of RBCs typically takes less than 1 minute, the results of these studies may be less accurate and less relevant for in vitro-in vivo correlation. In our current study, we introduce a computer vision-enhanced microfluidic framework designed to automatically capture the transient sickling kinetics of SS RBCs within a 1-min timeframe. Our study has successfully detected differences in the transient sickling kinetics between vehicle control and voxelotor-treated SS RBCs. This approach has the potential for broader applications in screening anti-sickling therapies.

59 BASIC BIOLOGICAL SCIENCES↗

An Anisotropic Local Method for Boundary Detection

Plan to submit this to the Journal of Statistical Analysis and Data Mining for their special issue on CoDA (Conference on Data Analysis, a meeting of analysts and scientists from the national labs)

97 MATHEMATICS AND COMPUTING↗

SU-F-I-12: Region-Specific Dictionary Learning for Low-Dose X-Ray CT Reconstruction

Purpose: Dictionary learning based method has attracted more and more attentions in low-dose CT due to the superior performance on suppressing noise and preserving structural details. Considering the structures and noise vary from region to region in one imaging object, we propose a region-specific dictionary learning method to improve the low-dose CT reconstruction. Methods: A set of normal-dose images was used for dictionary learning. Segmentations were performed on these images, so that the training patch sets corresponding to different regions can be extracted out. After that, region-specific dictionaries were learned from these training sets. For the low-dose CT reconstruction, a conventional reconstruction, such as filtered back-projection (FBP), was performed firstly, and then segmentation was followed to segment the image into different regions. Sparsity constraints of each region based on its dictionary were used as regularization terms. The regularization parameters were selected adaptively according to different regions. A low-dose human thorax dataset was used to evaluate the proposed method. The single dictionary based method was performed for comparison. Results: Since the lung region is very different from the other part of thorax, two dictionaries corresponding to lung region and the rest part of thorax respectively were learned to better express the structural details and avoid artifacts. With only one dictionary some artifact appeared in the body region caused by the spot atoms corresponding to the structures in the lung region. And also some structure in the lung regions cannot be recovered well by only one dictionary. The quantitative indices of the result by the proposed method were also improved a little compared to the single dictionary based method. Conclusion: Region-specific dictionary can make the dictionary more adaptive to different region characteristics, which is much desirable for enhancing the performance of dictionary learning based method.

60 APPLIED LIFE SCIENCES↗

Deep Learning for Semantic Segmentation of Defects in Advanced STEM Images of Steels

Crystalline materials exhibit long-range ordered lattice unit, within which resides nonperiodic structural features called defects. These crystallographic defects play a vital role in determining the physical and mechanical properties of a wide range of material systems. While computer vision has demonstrated success in recognizing feature patterns in images with well defined contrast, automated identification of nanometer scale crystallographic defects in electron micrographs governed by complex contrast mechanism is still a challenging task. Here, building upon an advanced defect imaging mode that offers high feature clarity, we introduce DefectSegNet - a new convolutional neural network (CNN) architecture that performs semantic segmentation of three common crystallographic defects in structural alloys: dislocation lines, precipitates and voids. Results from supervised training of a small set of high-quality defect images of steels show high pixel-wise accuracy across all three types of defects: 91.60 ± 1.77% on dislocations, 93.39 ± 1.00% on precipitates, and 98.85 ± 0.56% on voids. We discuss the sources of uncertainties in CNN prediction, and the training data in terms of feature density, representation and homogeneity and their effects on deep learning performance. Further defect quantification using DefectSegNet prediction outperforms human expert average, presenting a promising new workflow for fast and statistically meaningful quantification of materials defects.

36 MATERIALS SCIENCE↗

Application of a deep learning semantic segmentation model to helium bubbles and voids in nuclear materials

Imaging nanoscale radiation-induced defects using the transmission electron microscope (TEM) is a key factor in the successful implementation of materials for nuclear energy structural applications. Analyzing each defect in a TEM micrograph is currently a manual task. To identify the defects in a single image can take anywhere from 15 min to an hour and a project can require the analysis of anywhere from tens to ≥ 100 images. Here, we use artificial intelligence (AI) models to automate this task. For simplification, we evaluated images with only a single type of defect; helium bubbles. Additionally, we performed semantic segmentation of these helium bubble defects in electron microscopy images of irradiated FeCrAl alloys using a deep learning DefectSegNet model. This model, which was previously used to classify crystal defects, is inspired by the classic DenseNet and U-Net image segmentation models. It claims high spatial resolution, but has poor performance at object boundaries. Our paper improves the DefectSegNet model’s application by adding two new features. First, the DefectSegNet model is applied not only to perform calculation pixel-wise but also object (or feature) wise. Because object-wise metrics are directly relevant to our final goal of detecting bubbles, whereas pixel-wise classification is only an intermediate step, it is an important part of our study. Second, a distance map loss (DML) function has been added to increase its performance at object boundaries. It is crucial to accurately represent defects boundaries, especially bubbles, in order to track the bubble-induced swelling caused by irradiation. The boundary-focused DML function is also compared to other loss functions like Cross-entropy, Weighted Binary Cross Entropy (WBCE), Dice and Intersection over Union (IOU). Finally, by incorporating new features, we found a marked improvement on segmentation quality and better shape preservation at the boundaries and areas of the bubbles.

42 ENGINEERING↗

Results with a 32 element dual mode imager.

We present advances with a 32 element scalable, segmented dual mode imager. Scaling up the number of cells results in a 1.4 increase in efficiency over a system we deployed last year. Variable plane separation has been incorporated which further improves the efficiency of the detector. By using 20 cm diameter cells we demonstrate that we could increase sensitivity by a factor of 6. We further demonstrate gamma ray imaging in from Compton scattering. This feature allows for powerful dual mode imaging. Selected results are presented that demonstrate these new capabilities.

99 GENERAL AND MISCELLANEOUS↗

Results with a 32-element dual mode imager.

We present advances with a 32 element scalable, segmented dual mode imager. Scaling up the number of cells results in a 1.4 increase in efficiency over a system we deployed last year. Variable plane separation has been incorporated which further improves the efficiency of the detector. By using 20 cm diameter cells we demonstrate that we could increase sensitivity by a factor of 6. We further demonstrate gamma ray imaging in from Compton scattering. This feature allows for powerful dual mode imaging. Selected results are presented that demonstrate these new capabilities.

99 GENERAL AND MISCELLANEOUS↗

Automatic Segmentation of the Eye in 3D Magnetic Resonance Imaging: A Novel Statistical Shape Model for Treatment Planning of Retinoblastoma

Purpose: Proper delineation of ocular anatomy in 3-dimensional (3D) imaging is a big challenge, particularly when developing treatment plans for ocular diseases. Magnetic resonance imaging (MRI) is presently used in clinical practice for diagnosis confirmation and treatment planning for treatment of retinoblastoma in infants, where it serves as a source of information, complementary to the fundus or ultrasonographic imaging. Here we present a framework to fully automatically segment the eye anatomy for MRI based on 3D active shape models (ASM), and we validate the results and present a proof of concept to automatically segment pathological eyes. Methods and Materials: Manual and automatic segmentation were performed in 24 images of healthy children's eyes (3.29 ± 2.15 years of age). Imaging was performed using a 3-T MRI scanner. The ASM consists of the lens, the vitreous humor, the sclera, and the cornea. The model was fitted by first automatically detecting the position of the eye center, the lens, and the optic nerve, and then aligning the model and fitting it to the patient. We validated our segmentation method by using a leave-one-out cross-validation. The segmentation results were evaluated by measuring the overlap, using the Dice similarity coefficient (DSC) and the mean distance error. Results: We obtained a DSC of 94.90 ± 2.12% for the sclera and the cornea, 94.72 ± 1.89% for the vitreous humor, and 85.16 ± 4.91% for the lens. The mean distance error was 0.26 ± 0.09 mm. The entire process took 14 seconds on average per eye. Conclusion: We provide a reliable and accurate tool that enables clinicians to automatically segment the sclera, the cornea, the vitreous humor, and the lens, using MRI. We additionally present a proof of concept for fully automatically segmenting eye pathology. This tool reduces the time needed for eye shape delineation and thus can help clinicians when planning eye treatment and confirming the extent of the tumor.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Automatic Segmentation of Whole Breast Using Atlas Approach and Deformable Image Registration

Purpose: To compare interobserver variations in delineating the whole breast for treatment planning using two contouring methods. Methods and Materials: Autosegmented contours were generated by a deformable image registration-based breast segmentation method (DEF-SEG) by mapping the whole breast clinical target volume (CTVwb) from a template case to a new patient case. Eight breast radiation oncologists modified the autosegmented contours as necessary to achieve a clinically appropriate CTVwb and then recontoured the same case from scratch for comparison. The times to complete each approach, as well as the interobserver variations, were analyzed. The template case was also mapped to 10 breast cancer patients with a body mass index of 19.1-35.9 kg/m{sup 2}. The three-dimensional surface-to-surface distances and volume overlapping analyses were computed to quantify contour variations. Results: The median time to edit the DEF-SEG-generated CTVwb was 12.9 min (range, 3.4-35.9) compared with 18.6 min (range, 8.9-45.2) to contour the CTVwb from scratch (30% faster, p = 0.028). The mean surface-to-surface distance was noticeably reduced from 1.6 mm among the contours generated from scratch to 1.0 mm using the DEF-SEG method (p = 0.047). The deformed contours in 10 patients achieved 94% volume overlap before correction and required editing of 5% (range, 1-10%) of the contoured volume. Conclusion: Significant interobserver variations suggested a lack of consensus regarding the CTVwb, even among breast cancer specialists. Using the DEF-SEG method produced more consistent results and required less time. The DEF-SEG method can be successfully applied to patients with different body mass indexes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

MO-C-17A-11: A Segmentation and Point Matching Enhanced Deformable Image Registration Method for Dose Accumulation Between HDR CT Images

Purpose: To propose and validate a novel and accurate deformable image registration (DIR) scheme to facilitate dose accumulation among treatment fractions of high-dose-rate (HDR) gynecological brachytherapy. Method: We have developed a method to adapt DIR algorithms to gynecologic anatomies with HDR applicators by incorporating a segmentation step and a point-matching step into an existing DIR framework. In the segmentation step, random walks algorithm is used to accurately segment and remove the applicator region (AR) in the HDR CT image. A semi-automatic seed point generation approach is developed to obtain the incremented foreground and background point sets to feed the random walks algorithm. In the subsequent point-matching step, a feature-based thin-plate spline-robust point matching (TPS-RPM) algorithm is employed for AR surface point matching. With the resulting mapping, a DVF characteristic of the deformation between the two AR surfaces is generated by B-spline approximation, which serves as the initial DVF for the following Demons DIR between the two AR-free HDR CT images. Finally, the calculated DVF via Demons combined with the initial one serve as the final DVF to map doses between HDR fractions. Results: The segmentation and registration accuracy are quantitatively assessed by nine clinical HDR cases from three gynecological cancer patients. The quantitative results as well as the visual inspection of the DIR indicate that our proposed method can suppress the interference of the applicator with the DIR algorithm, and accurately register HDR CT images as well as deform and add interfractional HDR doses. Conclusions: We have developed a novel and robust DIR scheme that can perform registration between HDR gynecological CT images and yield accurate registration results. This new DIR scheme has potential for accurate interfractional HDR dose accumulation. This work is supported in part by the National Natural ScienceFoundation of China (no 30970866 and no 81301940)

60 APPLIED LIFE SCIENCES↗

TU-CD-207-12: Impact of Anatomical Noise On Detection Performance of Microcalcifications in Multi-Contrast Breast Imaging

Purpose: The anatomical noise power spectra (NPS) for differential phase contrast (DPC) and dark field (DF) imaging have recently been characterized using a power-law model with two parameters, alpha and beta, an innovative extension to the methodology used in x-ray attenuation based breast imaging such as mammography, DBT, or cone-beam CT. Beta values of 3.6, 2.6, and 1.3 have been measured for absorption, DPC, and DF respectively for cadaver breasts imaged in the coronal plane; these dramatic differences should be reflected in their detection performance. The purpose of this study was to determine the impact of anatomical noise on breast calcification detection and compare the detection performance of the three contrast mechanisms of a multi-contrast x-ray imaging system. Methods: In our studies, a calcification image object was segmented out of the multi-contrast images of a cadaver breast specimen. 50 measured total NPS were measured from breast cadavers directly. The ideal model observer detectability was calculated for a range of doses (5–100%) and a range of calcification sizes (diameter = 0.25–2.5 mm). Results: Overall we found the highest average detectability corresponded to DPC imaging (7.4 for 1 mm calc.), with DF the next highest (3.8 for 1 mm calc.), and absorption the lowest (3.2 for 1 mm calc.). However, absorption imaging also showed the slowest dependence on dose of the three modalities due to the significant anatomical noise. DPC showed a peak detectability for calcifications ∼1.25 mm in diameter, DF showed a peak for calcifications around 0.75 mm in diameter, and absorption imaging had no such peak in the range explored. Conclusion: Understanding imaging performance for DPC and DF is critical to transition these modalities to the clinic. The results presented here offer new insight into how these modalities complement absorption imaging to maximize the likelihood of detecting early breast cancers. J. Garrett, Y. Ge, K. Li: Nothing to disclose. G.-H. Chen: Research funded, GE Healthcare; Research funded, Siemens AX.

60 APPLIED LIFE SCIENCES↗

Unsupervised Tattoo Segmentation Combining Bottom-Up and Top-Down Cues

Tattoo segmentation is challenging due to the complexity and large variance in tattoo structures. We have developed a segmentation algorithm for nding tattoos in an image. Our basic idea is split-merge: split each tattoo image into clusters through a bottom-up process, learn to merge the clusters containing skin and then distinguish tattoo from the other skin via top-down prior in the image itself. Tattoo segmentation with unknown number of clusters is transferred to a gure-ground segmentation. We have applied our segmentation algorithm on a tattoo dataset and the results have shown that our tattoo segmentation system is e cient and suitable for further tattoo classi cation and retrieval purpose.

Allen, Josef D↗

TH-A-18C-01: Design Optimization of Segmented Scintillators for Megavoltage Cone- Beam CT

Purpose: Active matrix flat-panel imagers incorporating thick, segmented scintillators for megavoltage cone-beam CT (MV CBCT) imaging have demonstrated strong potential for facilitating soft-tissue visualization at low, clinically practical doses. In order to identify scintillator design parameters that optimize performance for this purpose, a modeling technique which includes both radiation and optical effects and which lends itself to computationally practical implementation has been developed and explored. Methods: A hybrid modeling technique, based on Monte Carlo event-by-event simulation of radiation transport and separate determination of optical effects, was devised as an alternative to computationally prohibitive event-by- event simulations of both radiation and optical transport. The technique was validated against empirical results from a previously reported 1.13 cm thick, 1.016 mm element-to-element pitch BGO scintillator prototype. Using this technique, the contrast-to-noise ratio (CNR) and spatial resolution performance of numerous scintillator designs, with thicknesses ranging from 0.5 to 6 cm and pitches ranging from 0.508 to 1.524 mm, were examined. Results: CNR and spatial resolution performance for the various scintillator designs demonstrate complex behavior as scintillator thickness and pitch are varied - exhibiting a clear trade-off between these two imaging metrics up to a thickness of ~3 cm. Based on these results, an optimization map highlighting those regions of design that provide a balance between these metrics was created. The map indicates that, for a given set of optical parameters, scintillator thickness and pitch can be judiciously chosen to maximize performance without resorting to thicker, more costly scintillators. Conclusion: Modeling radiation and optical effects in thick, segmented scintillators through use of a hybrid modeling technique provides a practical way to gain insight as to how to optimize the performance of such devices for radiotherapy imaging. Assisted by such modeling, the development of practical designs should greatly facilitate low-dose, soft tissue visualization through MV CBCT imaging. This project was supported in part by NIH grant R01 CA051397.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Instance Segmentation for Direct Measurements of Satellites in Metal Powders and Automated Microstructural Characterization from Image Data

In this work, we propose instance segmentation as a useful tool for image analysis in materials science. Instance segmentation is an advanced technique in computer vision which generates individual segmentation masks for every object of interest that is recognized in an image. Using an out-of-the-box implementation of Mask R-CNN, instance segmentation is applied to images of metal powder particles produced through gas atomization. Leveraging transfer learning allows for the analysis to be conducted with a very small training set of labeled images. As well as providing another method for measuring the particle size distribution, we demonstrate the first direct measurements of the satellite content in powder samples. After analyzing the results for the labeled data dataset, the trained model was used to generate measurements for a much larger set of unlabeled images. The resulting particle size measurements showed reasonable agreement with laser scattering measurements. The satellite measurements were self-consistent and showed good agreement with the expected trends for different samples. Finally, we present a small case study showing how instance segmentation can be used to measure spheroidite content in the UltraHigh Carbon Steel DataBase, demonstrating the flexibility of the technique.

36 MATERIALS SCIENCE↗