Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Image Reconstruction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Surrogate Distributed Radiological Sources—Part III: Quantitative Distributed Source Reconstructions

In this third part of a multi-paper series, we present quantitative image reconstruction results from aerial measurements of eight different surrogate distributed gamma-ray sources on flat terrain. Here, we show that our quantitative imaging methods can accurately reconstruct the expected shapes, and, after appropriate calibration, the absolute activity of the distributed sources. We conduct several studies of imaging performance versus various measurement and reconstruction parameters, including detector altitude and raster pass spacing, data and modeling fidelity, and regularization type and strength. The imaging quality performance is quantified using various quantitative image quality metrics. Our results confirm the utility of point source arrays as surrogates for truly distributed radiological sources, and advance the quantitative capabilities of Scene Data Fusion gamma-ray imaging methods.

Airborne survey↗

TH-EF-BRA-03: Assessment of Data-Driven Respiratory Motion-Compensation Methods for 4D-CBCT Image Registration and Reconstruction Using Clinical Datasets

Purpose: To evaluate the performance of a 4D-CBCT registration and reconstruction method that corrects for respiratory motion and enhances image quality under clinically relevant conditions. Methods: Building on previous work, which tested feasibility of a motion-compensation workflow using image datasets superior to clinical acquisitions, this study assesses workflow performance under clinical conditions in terms of image quality improvement. Evaluated workflows utilized a combination of groupwise deformable image registration (DIR) and image reconstruction. Four-dimensional cone beam CT (4D-CBCT) FDK reconstructions were registered to either mean or respiratory phase reference frame images to model respiratory motion. The resulting 4D transformation was used to deform projection data during the FDK backprojection operation to create a motion-compensated reconstruction. To simulate clinically realistic conditions, superior quality projection datasets were sampled using a phase-binned striding method. Tissue interface sharpness (TIS) was defined as the slope of a sigmoid curve fit to the lung-diaphragm boundary or to the carina tissue-airway boundary when no diaphragm was discernable. Image quality improvement was assessed in 19 clinical cases by evaluating mitigation of view-aliasing artifacts, tissue interface sharpness recovery, and noise reduction. Results: For clinical datasets, evaluated average TIS recovery relative to base 4D-CBCT reconstructions was observed to be 87% using fixed-frame registration alone; 87% using fixed-frame with motion-compensated reconstruction; 92% using mean-frame registration alone; and 90% using mean-frame with motion-compensated reconstruction. Soft tissue noise was reduced on average by 43% and 44% for the fixed-frame registration and registration with motion-compensation methods, respectively, and by 40% and 42% for the corresponding mean-frame methods. Considerable reductions in view aliasing artifacts were observed for each method. Conclusion: Data-driven groupwise registration and motion-compensated reconstruction have the potential to improve the quality of 4D-CBCT images acquired under clinical conditions. For clinical image datasets, the addition of motion compensation after groupwise registration visibly reduced artifact impact. This work was supported by the National Cancer Institute of the National Institutes of Health under Award Number R01CA166119. Hugo and Weiss hold a research agreement with Philips Healthcare and license agreement with Varian Medical Systems. Weiss receives royalties from UpToDate. Christensen receives funds from Roger Koch to support research.

60 APPLIED LIFE SCIENCES↗

Ghost imaging second harmonic generation microscopy

Second harmonic generation (SHG) microscopy is useful for visualizing interfaces and sub-structures within a wide range of materials due to the propensity for SHG to occur in non-centrosymmetric environments. However, since SHG is a nonlinear process generally necessitating small focal sizes for higher peak powers, a raster scanning approach is usually needed to build an SHG image over a significant sample size. While raster scanning is effective, there is a cost in terms of the time needed to acquire the image and, also, some materials cannot withstand the higher optical intensities within the small focal volume. As such, we describe a SHG microscopy approach based on ghost imaging (GI), which enables imaging data to be collected in parallel rather than sequentially as in raster scanning techniques. We experimentally demonstrate the approach and combine GI-SHG with compressive sensing to make further substantial gains in reducing the amount of sampling required for image reconstruction. Furthermore, GI-SHG is shown to have significant advantages for imaging in highly scattering environments, partly because GI is a background-free approach requiring spatial correlations between photons that travel two paths, with one path entirely devoid of sample interaction. This basic property of GI means that only the photons that travel unimpeded through the sample preserve the spatial correlations needed to reconstruct the image, while more scattered photons do not contribute to the overall GI signal. Finally, we compare the image quality and sampling properties of three different reconstruction algorithms used for compressive sensing.

47 OTHER INSTRUMENTATION↗

SU-E-I-45: Reconstruction of CT Images From Sparsely-Sampled Data Using the Logarithmic Barrier Method

Purpose: To develop and investigate whether the logarithmic barrier (LB) method can result in high-quality reconstructed CT images using sparsely-sampled noisy projection data Methods: The objective function is typically formulated as the sum of the total variation (TV) and a data fidelity (DF) term with a parameter λ that governs the relative weight between them. Finding the optimized value of λ is a critical step for this approach to give satisfactory results. The proposed LB method avoid using λ by constructing the objective function as the sum of the TV and a log function whose augment is the DF term. Newton's method was used to solve the optimization problem. The algorithm was coded in MatLab2013b. Both Shepp-Logan phantom and a patient lung CT image were used for demonstration of the algorithm. Measured data were simulated by calculating the projection data using radon transform. A Poisson noise model was used to account for the simulated detector noise. The iteration stopped when the difference of the current TV and the previous one was less than 1%. Results: Shepp-Logan phantom reconstruction study shows that filtered back-projection (FBP) gives high streak artifacts for 30 and 40 projections. Although visually the streak artifacts are less pronounced for 64 and 90 projections in FBP, the 1D pixel profiles indicate that FBP gives noisier reconstructed pixel values than LB does. A lung image reconstruction is presented. It shows that use of 64 projections gives satisfactory reconstructed image quality with regard to noise suppression and sharp edge preservation. Conclusion: This study demonstrates that the logarithmic barrier method can be used to reconstruct CT images from sparsely-amped data. The number of projections around 64 gives a balance between the over-smoothing of the sharp demarcation and noise suppression. Future study may extend to CBCT reconstruction and improvement on computation speed.

60 APPLIED LIFE SCIENCES↗

IMAGING THE ALGOL TRIPLE SYSTEM IN THE H BAND WITH THE CHARA INTERFEROMETER

Algol ({beta} Per) is an extensively studied hierarchical triple system whose inner pair is a prototype semi-detached binary with mass transfer occurring from the sub-giant secondary to the main-sequence primary. We present here the results of our Algol observations made between 2006 and 2010 at the CHARA interferometer with the Michigan Infrared Combiner in the H-band. The use of four telescopes with long baselines allows us to achieve better than 0.5 mas resolution and to unambiguously resolve the three stars. The inner and outer orbital elements, as well as the angular sizes and mass ratios for the three components, are determined independently from previous studies. We report a significantly improved orbit for the inner stellar pair with the consequence of a 15% change in the primary mass compared with previous studies. We also determine the mutual inclination of the orbits to be much closer to perpendicularity than previously established. State-of-the-art image reconstruction algorithms are used to image the full triple system. In particular an image sequence of 55 distinct phases of the inner pair orbit is reconstructed, clearly showing the Roche-lobe-filling secondary revolving around the primary, with several epochs corresponding to the primary and secondary eclipses.

79 ASTRONOMY AND ASTROPHYSICS↗

Metal artifact reduction in x-ray computed tomography (CT) by constrained optimization

Purpose: The streak artifacts caused by metal implants have long been recognized as a problem that limits various applications of CT imaging. In this work, the authors propose an iterative metal artifact reduction algorithm based on constrained optimization. Methods: After the shape and location of metal objects in the image domain is determined automatically by the binary metal identification algorithm and the segmentation of ''metal shadows'' in projection domain is done, constrained optimization is used for image reconstruction. It minimizes a predefined function that reflects a priori knowledge of the image, subject to the constraint that the estimated projection data are within a specified tolerance of the available metal-shadow-excluded projection data, with image non-negativity enforced. The minimization problem is solved through the alternation of projection-onto-convex-sets and the steepest gradient descent of the objective function. The constrained optimization algorithm is evaluated with a penalized smoothness objective. Results: The study shows that the proposed method is capable of significantly reducing metal artifacts, suppressing noise, and improving soft-tissue visibility. It outperforms the FBP-type methods and ART and EM methods and yields artifacts-free images. Conclusions: Constrained optimization is an effective way to deal with CT reconstruction with embedded metal objects. Although the method is presented in the context of metal artifacts, it is applicable to general ''missing data'' image reconstruction problems.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The SRT reconstruction algorithm for semiquantification in PET imaging

Purpose: The spline reconstruction technique (SRT) is a new, fast algorithm based on a novel numerical implementation of an analytic representation of the inverse Radon transform. The mathematical details of this algorithm and comparisons with filtered backprojection were presented earlier in the literature. In this study, the authors present a comparison between SRT and the ordered-subsets expectation–maximization (OSEM) algorithm for determining contrast and semiquantitative indices of {sup 18}F-FDG uptake. Methods: The authors implemented SRT in the software for tomographic image reconstruction (STIR) open-source platform and evaluated this technique using simulated and real sinograms obtained from the GE Discovery ST positron emission tomography/computer tomography scanner. All simulations and reconstructions were performed in STIR. For OSEM, the authors used the clinical protocol of their scanner, namely, 21 subsets and two iterations. The authors also examined images at one, four, six, and ten iterations. For the simulation studies, the authors analyzed an image-quality phantom with cold and hot lesions. Two different versions of the phantom were employed at two different hot-sphere lesion-to-background ratios (LBRs), namely, 2:1 and 4:1. For each noiseless sinogram, 20 Poisson realizations were created at five different noise levels. In addition to making visual comparisons of the reconstructed images, the authors determined contrast and bias as a function of the background image roughness (IR). For the real-data studies, sinograms of an image-quality phantom simulating the human torso were employed. The authors determined contrast and LBR as a function of the background IR. Finally, the authors present plots of contrast as a function of IR after smoothing each reconstructed image with Gaussian filters of six different sizes. Statistical significance was determined by employing the Wilcoxon rank-sum test. Results: In both simulated and real studies, SRT exhibits higher contrast and lower bias than OSEM at the cold lesions. This improvement is achieved at the expense of increasing the noise in the reconstructed images. For the hot lesions, SRT exhibits a small improvement in contrast and LBR over OSEM with 21 subsets and two iterations; however, this improvement is not statistically significant. As the number of iterations increases, the performance of OSEM improves over SRT but again without statistical significance. The curves of contrast and LBR as a function of IR after Gaussian blurring indicate that the advantage of SRT in the cold regions is maintained even after decreasing the noise level by Gaussian blurring. Conclusions: SRT, at the expense of slightly increased noise in the reconstructed images, reconstructs images of higher contrast and lower bias than the clinical protocol of OSEM. This improvement is particularly evident for images involving cold regions. Thus, it appears that SRT should be particularly useful for the quantification of low-count and cold regions.

60 APPLIED LIFE SCIENCES↗

An Image Processing Algorithm Based On FMAT

Information deleted in ways minimizing adverse effects on reconstructed images. New grey-scale generalization of medial axis transformation (MAT), called FMAT (short for Fuzzy MAT) proposed. Formulated by making natural extension to fuzzy-set theory of all definitions and conditions (e.g., characteristic function of disk, subset condition of disk, and redundancy checking) used in defining MAT of crisp set. Does not need image to have any kind of priori segmentation, and allows medial axis (and skeleton) to be fuzzy subset of input image. Resulting FMAT (consisting of maximal fuzzy disks) capable of reconstructing exactly original image.

Wang, Lui↗

STEREOSCOPIC POLAR PLUME RECONSTRUCTIONS FROM STEREO/SECCHI IMAGES

We present stereoscopic reconstructions of the location and inclination of polar plumes of two data sets based on the two simultaneously recorded images taken by the EUVI telescopes in the SECCHI instrument package onboard the Solar TErrestrial RElations Observatory spacecraft. The 10 plumes investigated show a superradial expansion in the coronal hole in three dimensions (3D) which is consistent with the two-dimensional results. Their deviations from the local meridian planes are rather small with an average of 6.{sup 0}47. By comparing the reconstructed plumes with a dipole field with its axis along the solar rotation axis, it is found that plumes are inclined more horizontally than the dipole field. The lower the latitude is, the larger is the deviation from the dipole field. The relationship between plumes and bright points has been investigated and they are not always associated. For the first data set, based on the 3D height of plumes and the electron density derived from SUMER/SOHO Si VIII line pair, we found that electron densities along the plumes decrease with height above the solar surface. The temperature obtained from the density scale height is 1.6-1.8 times larger than the temperature obtained from Mg IX line ratios. We attribute this discrepancy to a deviation of the electron and the ion temperatures. Finally, we have found that the outflow speeds studied in the O VI line in the plumes corrected by the angle between the line of sight and the plume orientation are quite small with a maximum of 10 km s{sup -1}. It is unlikely that plumes are a dominant contributor to the fast solar wind.

99 GENERAL AND MISCELLANEOUS↗

Development of a prototype Open-close positron emission tomography system

We developed a prototype positron emission tomography (PET) system based on a new concept called Open-close PET, which has two modes: open and close-modes. In the open-mode, the detector ring is separated into two halved rings and subject is imaged with the open space and projection image is formed. In the close-mode, the detector ring is closed to be a regular circular ring, and the subject can be imaged without an open space, and so reconstructed images can be made without artifacts. The block detector of the Open-close PET system consists of two scintillator blocks that use two types of gadolinium orthosilicate (GSO) scintillators with different decay times, angled optical fiber-based image guides, and a flat panel photomultiplier tube. The GSO pixel size was 1.6 × 2.4 × 7 mm and 8 mm for fast (35 ns) and slow (60 ns) GSOs, respectively. These GSOs were arranged into an 11 × 15 matrix and optically coupled in the depth direction to form a depth-of-interaction detector. The angled optical fiber-based image guides were used to arrange the two scintillator blocks at 22.5° so that they can be arranged in a hexadecagonal shape with eight block detectors to simplify the reconstruction algorithm. The detector ring was divided into two halves to realize the open-mode and set on a mechanical stand with which the distance between the two parts can be manually changed. The spatial resolution in the close-mode was 2.4-mm FWHM, and the sensitivity was 1.7% at the center of the field-of-view. In both the close- and open-modes, we made sagittal (y-z plane) projection images between the two halved detector rings. We obtained reconstructed and projection images of {sup 18}F-NaF rat studies and proton-irradiated phantom images. These results indicate that our developed Open-close PET is useful for some applications such as proton therapy as well as other applications such as molecular imaging.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Acquisition of STEM Images by Adaptive Compressive Sensing

Compressive Sensing (CS) allows a signal to be sparsely measured first and accurately recovered later in software [1]. In scanning transmission electron microscopy (STEM), it is possible to compress an image spatially by reducing the number of measured pixels, which decreases electron dose and increases sensing speed [2,3,4]. The two requirements for CS to work are: (1) sparsity of basis coefficients and (2) incoherence of the sensing system and the representation system. However, when pixels are missing from the image, it is difficult to have an incoherent sensing matrix. Nevertheless, dictionary learning techniques such as Beta-Process Factor Analysis (BPFA) [5] are able to simultaneously discover a basis and the sparse coefficients in the case of missing pixels. On top of CS, we would like to apply active learning [6,7] to further reduce the proportion of pixels being measured, while maintaining image reconstruction quality. Suppose we initially sample 10% of random pixels. We wish to select the next 1% of pixels that are most useful in recovering the image. Now, we have 11% of pixels, and we want to decide the next 1% of “most informative” pixels. Active learning methods are online and sequential in nature. Our goal is to adaptively discover the best sensing mask during acquisition using feedback about the structures in the image. In the end, we hope to recover a high quality reconstruction with a dose reduction relative to the non-adaptive (random) sensing scheme. In doing this, we try three metrics applied to the partial reconstructions for selecting the new set of pixels: (1) variance, (2) Kullback-Leibler (KL) divergence using a Radial Basis Function (RBF) kernel, and (3) entropy. Figs. 1 and 2 display the comparison of Peak Signal-to-Noise (PSNR) using these three different active learning methods at different percentages of sampled pixels. At 20% level, all the three active learning methods underperform the original CS without active learning. However, they all beat the original CS as more of the “most informative” pixels are sampled. One can also argue that CS equipped with active learning requires less sampled pixels to achieve the same value of PSNR than CS with pixels randomly sampled, since all the three PSNR curves with active learning grow at a faster pace than that without active learning. For this particular STEM image, by observing the reconstructed images and the sensing masks, we find that while the method based on RBF kernel acquires samples more uniformly, the one on entropy samples more areas of significant change, thus less uniformly. The KL-divergence method performs the best in terms of reconstruction error (PSNR) for this example [8].

Xie, Weiyi↗

Image-based iterative compensation of motion artifacts in computed tomography

Purpose: This article presents an iterative method for compensation of motion artifacts for slowly rotating computed tomography (CT) systems. Patient's motion introduces inconsistencies among projections and yields severe reconstruction artifacts for free-breathing acquisitions. Streaks and doubling of structures can appear and the resolution is limited by strong blurring. Methods: The rationale of the proposed motion compensation method is to iteratively correct the reconstructed image by first decomposing the perceived motion in projection space, then reconstructing the motion artifacts in image space, and finally subtracting the artifacts from an initial image. The initial image is reconstructed from the acquired data and might contain motion blur artifacts but, nevertheless, is considered as a reference for estimating the reconstruction artifacts. Results: Qualitative and quantitative figures are shown for experiments based on numerically simulated projections of a sequence of clinical images resulting from a respiratory-gated helical CT acquisition. The border of the diaphragm becomes progressively sharper and the contrast improves for small structures in the lungs. Conclusions: The originality of the technique stems from the fact that the patient motion is not explicitly estimated but the motion artifacts are reconstructed in image space. This approach could provide sharp static anatomical images on interventional C-arm systems or on slowly rotating X-ray equipments in radiotherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Advanced Millimeter-Wave Security Portal Imaging Techniques

Millimeter-wave imaging is rapidly gaining acceptance for passenger screening at airports and other secured facilities. This paper details a number of techniques developed over the last several years including novel image reconstruction and display techniques, polarimetric imaging techniques, array switching schemes, as well as high frequency high bandwidth techniques. Implementation of some of these methods will increase the cost and complexity of the mm-wave security portal imaging systems. RF photonic methods may provide new solutions to the design and development of the sequentially switched linear mm-wave arrays that are the key element in the mm-wave portal imaging systems.

99 GENERAL AND MISCELLANEOUS↗

Advanced Millimeter-Wave Imaging Enhances Security Screening

Millimeter-wave imaging is rapidly gaining acceptance for passenger screening at airports and other secured facilities. This paper details a number of techniques developed over the last several years including novel image reconstruction and display techniques, polarimetric imaging techniques, array switching schemes, as well as high frequency high bandwidth techniques. Implementation of some of these methods will increase the cost and complexity of the mm-wave security portal imaging systems. RF photonic methods may provide new solutions to the design and development of the sequentially switched linear mm-wave arrays that are the key element in the mm-wave portal imaging systems.

Imaging↗

Iris recognition via plenoptic imaging

Iris recognition can be accomplished for a wide variety of eye images by using plenoptic imaging. Using plenoptic technology, it is possible to correct focus after image acquisition. One example technology reconstructs images having different focus depths and stitches them together, resulting in a fully focused image, even in an off-angle gaze scenario. Another example technology determines three-dimensional data for an eye and incorporates it into an eye model used for iris recognition processing. Another example technology detects contact lenses. Application of the technologies can result in improved iris recognition under a wide variety of scenarios.

47 OTHER INSTRUMENTATION↗

Iris recognition via plenoptic imaging

Iris recognition can be accomplished for a wide variety of eye images by using plenoptic imaging. Using plenoptic technology, it is possible to correct focus after image acquisition. One example technology reconstructs images having different focus depths and stitches them together, resulting in a fully focused image, even in an off-angle gaze scenario. Another example technology determines three-dimensional data for an eye and incorporates it into an eye model used for iris recognition processing. Another example technology detects contact lenses. Application of the technologies can result in improved iris recognition under a wide variety of scenarios.

47 OTHER INSTRUMENTATION↗

Iris recognition via plenoptic imaging

Iris recognition can be accomplished for a wide variety of eye images by using plenoptic imaging. Using plenoptic technology, it is possible to correct focus after image acquisition. One example technology reconstructs images having different focus depths and stitches them together, resulting in a fully focused image, even in an off-angle gaze scenario. Another example technology determines three-dimensional data for an eye and incorporates it into an eye model used for iris recognition processing. Another example technology detects contact lenses. Application of the technologies can result in improved iris recognition under a wide variety of scenarios.

42 ENGINEERING↗

The impact of system matrix dimension on small FOV SPECT reconstruction with truncated projections

Purpose: A dedicated cardiac hybrid single photon emission computed tomography (SPECT)/CT scanner that uses cadmium zinc telluride detectors and multiple pinhole collimators for stationary acquisition offers many advantages. However, the impact of the reconstruction system matrix (SM) dimension on the reconstructed image quality from truncated projections and 19 angular samples acquired on this scanner has not been extensively investigated. In this study, the authors aimed to investigate the impact of the dimensions of SM and the use of body contour derived from adjunctive CT imaging as an object support in reconstruction on this scanner, in relation to background extracardiac activity. Methods: The authors first simulated a generic SPECT/CT system to image four NCAT phantoms with various levels of extracardiac activity and compared the reconstructions using SM in different dimensions and with/without body contour as a support for quantitative evaluations. The authors then compared the reconstructions of 18 patient studies, which were acquired on a GE Discovery NM570c scanner following injection of different radiotracers, including {sup 99m}Tc-Tetrofosmin and {sup 123}I-mIBG, comparing the scanner’s default SM that incompletely covers the body with a large SM that incorporates a patient specific full body contour. Results: The simulation studies showed that the reconstructions using a SM that only partially covers the body yielded artifacts on the edge of the field of view (FOV), overestimation of activity and increased nonuniformity in the blood pool for the phantoms with higher relative levels of extracardiac activity. However, the impact on the quantitative accuracy in the high activity region, such as the myocardium, was subtle. On the other hand, an excessively large SM that enclosed the entire body alleviated the artifacts and reduced overestimation in the blood pool, but yielded slight underestimation in myocardium and defect regions. The reconstruction using the larger SM with body contour yielded the most quantitatively accurate results in all the regions of interest for a range of uptake levels in the extracardiac regions. In patient studies, the SM incorporating patient specific body contour minimized extracardiac artifacts, yielded similar myocardial activity, lower blood pool activity, and subsequently improved myocardium-to-blood pool contrast (p < 0.0001) by an average of 7% (range 0%–18%) across all the patients, compared to the reconstructions using the scanner’s default SM. Conclusions: Their results demonstrate that using a large SM that incorporates a CT derived body contour in the reconstruction could improve quantitative accuracy within the FOV for clinical studies with high extracardiac activity.

61 RADIATION PROTECTION AND DOSIMETRY↗