Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ION BEAMS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

A methodology for customizing implantation profiles of light ions using a single thin foil energy degrader

We report a method was developed to quantify the spatial distribution and implantation depth of energy-degraded light ions with a thin foil rotating energy degrader for use during multiple ion beam irradiation. The methodology covers three physical phenomena: ions passing through the thin foil, ions travelling through the vacuum to the target, and ion implantation into the target, and accounts for the distribution of ions both in depth and in plane. The processes of energy straggling and scattering were calculated using SRIM. The effects of raster-scanning, and the geometry of the system were implemented in scripts handling the SRIM output files. Elastic backscattering (EBS) using 2.38 MeV H+ protons was used to measure the helium depth profiles after implantation with and without thin foil energy degradation. Defect analysis with transmission electron microscopy confirmed the implantation profiles measured with EBS and calculated with SRIM.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

H - Ion Source RF Plasma Testing with 13 MHz and 27 MHz at the Spallation Neutron Source (SNS)

The baseline RF-driven H⁻ ion source configuration at the Spallation Neutron Source (SNS) facility uses a continuous wave (CW) 600 W 13 MHz RF system to ignite and maintain a low-density plasma inside the ion source vacuum chamber. After the continuous low-density 13 MHz plasma has been established, a pulsed (typical 1 ms pulse width and 60 Hz pulse repetition rate) 80 kW 2 MHz RF system is used to increase the plasma density to produce the pulsed H⁻ ion beam. Incremental upgrades and improvements to the SNS ion source systems have resulted in the ability to reliably operate an H⁻ ion source for SNS neutron production run cycles that can last up to four months. Conditions inside the SNS H⁻ ion source evolve throughout a four-month run cycle due to changes in impurity levels, sputtering, and erosion. As the internal ion source conditions change during the run cycle, there can also be changes in plasma stability and the 13 MHz RF power level required to ignite the plasma. This paper presents the preliminary results of testing performed on the SNS Ion Source Test Stand (ISTS) system where we looked at plasma ignition and plasma stability using 27 MHz RF in place of the baseline 13 MHz RF system.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Evaluation of the accuracy of stopping and range of ions in matter simulations through secondary ion mass spectrometry and Rutherford backscattering spectrometry for low energy heavy ion implantation

The freely available “Stopping and Range of Ions in Matter” (SRIM) code is used for evaluating ion beam ranges and depth profiles. We present secondary ion mass spectrometry and Rutherford backscattering experimental results of Si samples implanted with low energy Sb ions to evaluate the accuracy of SRIM simulations. We show that the SRIM simulation systematically overestimates the range by 2–6 nm and this overestimation increases for larger ion implantation energy. For the lowest energy implantation investigated, here we find up to a 25% error between the SRIM simulation and the measured range. Finally, the ion straggle shows excellent agreement between simulation and experimental results.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Wilson Prize article: Transverse phase-space manipulations in electron accelerators

I am honored and grateful that my contributions to phase-space manipulations in general, and emittance compensation specifically, have been recognized by the Wilson Prize. The purpose of this article is to bring together what I believe to be the most important elements of the broad topic of transverse phase-space manipulations, focusing on the underlying beam physics which enable these types of schemes. We see that emittance compensation can be categorized as an example of the larger class of nonsymplectic manipulations. While the discussion is specifically focused on electron beams, much of the physics can also pertain to ion beams.

43 PARTICLE ACCELERATORS↗

Studying Corrosion Using Miniaturized Particle Attached Working Electrodes and the Nafion Membrane

We developed a new approach to attach particles onto a conductive layer as a working electrode (WE) in a microfluidic electrochemical cell with three electrodes. Nafion, an efficient proton transfer molecule, is used to form a thin protection layer to secure particle electrodes. Spin coating is used to develop a thin and even layer of Nafion membrane. The effects of Nafion (5 wt% 20 wt%) and spinning rates were evaluated using multiple sets of replicates. The electrochemical performance of various devices was demonstrated. Additionally, the electrochemical performance of the devices is used to select and optimize fabrication conditions. The results show that a higher spinning rate and a lower Nafion concentration (5 wt%) induce a better performance, using cerium oxide (CeO2) particles as a testing model. The WE surfaces were characterized using atomic force microscopy (AFM), scanning electron microscopy-focused ion beam (SEM-FIB), time-of-flight secondary ion mass spectrometry (ToF-SIMS), and X-ray photoelectron spectroscopy (XPS). The comparison between the pristine and corroded WE surfaces shows that Nafion is redistributed after potential is applied. Our results verify that Nafion membrane offers a reliable means to secure particles onto electrodes. Furthermore, the electrochemical performance is reliable and reproducible. Thus, this approach provides a new way to study more complex and challenging particles, such as uranium oxide, in the future.

42 ENGINEERING↗

Efficient laser-driven proton acceleration from a petawatt contrast-enhanced second harmonic mixed-glass laser system

Efficient laser-driven plasma acceleration of ion beams requires precision control of the target–plasma profile, which is crucial to optimize the laser energy transfer. Along the laser propagation direction, this can be achieved by tailoring the temporal structure of the laser pulse. We show for the first time that frequency-doubling of a short pulse (hundreds-femtosecond range) petawatt-class mixed-glass laser system, which results in temporal intensity contrast enhancement, enables surface and volumetric laser–energy coupling, and the acceleration of proton beams from few-nanometer-thick foil targets. Experimentally, maximum ion energies and laser-to-proton energy conversion efficiencies were found to be both maximized at optimum laser and target conditions manifested when the normalized target density nearly equalizes the normalized laser vector potential, which is in agreement with theory and simulations. These signatures are recognized as a unique indication of the interaction between ultra-intense laser pulses with high temporal intensity contrast and ultra-thin nanometer-scale targets. Transverse modulations of accelerated proton beams in the form of bubble- and ring-like structures measured in the thinnest targets provide additional evidence of volumetric laser-driven particle acceleration regimes and transitional features in ultra-thin foil targets specific to laser–plasma interactions characterized by a high temporal intensity contrast. These results open avenues in the generation of high contrast laser pulses from short-pulse-femtosecond petawatt mixed-glass laser systems and demonstrate the feasibility of this technique for applications requiring high laser intensity contrast with high efficiency.

Physics↗

Long-lived isomeric states and quasiparticle band structures in neutron-rich 162,164 Gd nuclei from β decay

Neutron-rich nuclei 162,164 Eu were produced by bombarding a proton beam on a 238 U target at the Holifield Radioactive Ion Beam Facility at Oak Ridge National Laboratory and mass separating the 162,164 Eu products. New level schemes and new γ-ray transitions of the daughters 162,164 Gd were identified from β-decay spectroscopy studies. Additionally, half-lives of the 162,164 Eu were remeasured to clarify the previous ambiguous results. Two quasiparticle band structures were built and compared with neighboring nuclei. The β and γ bands were extended in 162 Gd and a γ band was extended in 164 Gd. Half-lives of the isomeric states at (6 - ) 1449 keV in 162 Gd and (4 - ) 1096 keV in 164 Gd were measured to be 99(3) μs and 0.56(3) μs, respectively. Projected shell model calculations were performed and found to be in good agreement with all of the experimental data.

150 ≤ A ≤ 189↗

HJET performance in RHIC Run 22

In Run 22, the polarized proton beams were resumed at RHIC after four years of heavy ion beam operation. Here we compare HJET performance in the 255 GeV proton Runs 17 and 22. It was found that analyzing power calibration obtained in Run 17 can be used in Run 22 absolute proton beam polarization measurements. Results for average absolute proton beam polarization in the RHIC Run 22 stores are presented.

43 PARTICLE ACCELERATORS↗

Characterization of Self-Magnetic Pinch (SMP) Radiographic Diode Performance on RITS-6 at Sandia National Laboratories

The goals of an electron beam-driven radiographic source are the focusing of high current at high voltage to a minimal spot size with excellent shot-to-shot reproducibility. The Self-Magnetic Pinch (SMP) diode makes use of such an intense electron beam impinging on a high-atomic weight (tantalum) converter, a counter-streaming ion beam to help minimize the spot size, and operation in a magnetic field-free diode region which further encourages small spot size. Through a series of diode development experiments, output voltages up to 12.5 MV and output currents up to 225 kA have been characterized, with resulting spot sizes below ~ few mm. Scaling studies with parameter variation, such as diode aspect ratio and anode-cathode (A-K) gap variation, give systematic validation to what has heretofore been noted anecdotally by other research groups. While the lack of an imbedded magnetic field helps minimize the SMP spot size, a secondary result may be the generation of beam instabilities which can terminate the radiation pulse. There is anecdotal evidence that in-situ DC heating of the diode region can help stabilize the beam pinch. Clear experimental evidence exists that DC heating/RF cleaning results in better control over the counter-streaming ion population. Expanded use of spatial dose-rate detection is shown to yield new insights into electron beam dynamics in the SMP diode. An attendant study of the SMP diode as a load for an Inductive Voltage Adder (IVA) driver leads to insights into the behavior of the IVA-SMP diode configuration, viewed as a total system, and yields constraints on the overall impedance behavior of the SMP diode load.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Improved Electrostatic Design of the Jefferson Lab 300 kV DC Photogun and the Minimization of Beam Deflection

An electron beam with high bunch charge and high repetition rate is required for electron cooling of the ion beam to achieve the high luminosity required for the proposed electron-ion colliders. An improved design of the 300 kV DC high voltage photogun at Jefferson Lab was incorporated toward overcoming the beam loss and space charge current limitation experienced in the original design. To reach the bunch charge goal of ~ few nC within 75 ps bunches, the existing DC high voltage photogun electrodes and anode-cathode gap were modified to increase the longitudinal electric field (Ez) at the photocathode. The anode-cathode gap was reduced to increase the Ez at the photocathode, and the anode aperture was spatially shifted with respect to the beamline longitudinal axis to minimize the beam deflection introduced by the geometric asymmetry of the inverted insulator photogun. The electrostatic design and beam dynamics simulations were performed to determine the required modification. Beam-based measurement from the modified gun confirmed the reduction of the beam deflection, which is presented in this contribution.

Mamun, M. A.↗

Sculpting Non-Machinable Porous Materials

The goal of this project was to establish the scientific basis for subtractive manufacturing (sculpting) of porous materials using ion beams. Using the catcher foil technique, complemented with molecular dynamics simulations, we studied the dependence of the sputtering yield of Ag and Au nanofoams as a function of foam monolith density, ion mass, and the beam incidence angle, and compared these dependencies to those measured for full-density solids. We found that the foam sputtering yield was considerably lower than for the full-density solid. The sputtering yield increased with beam incidence angle, and the open structure of the foam suppressed the development of collision cascades. We also found that the sputtering yield decreased with increasing foam density. The simulation revealed a significant redeposition of sputtered atoms in the foam.

36 MATERIALS SCIENCE↗

Support for the 66th International Conference on Electron, Ion, and Photon Beam Technologies and Nanofabrication (Final Report)

This project aimed to enable student participation in the 66th International Conference on Electron, Ion, and Photon Beam Technologies and Nanofabrication (EIPBN). EIPBN, affectionately known as “3-Beams,” is the premier gathering of scientists and engineers who are dedicated to electron, ion and photon lithography, imaging, and analysis; nanofabrication process technologies; atomically precise fabrication; related emerging technologies; and their applications in a broad spectrum of fields. It is where top researchers from academia, government laboratories, and industries from around the world meet to present and discuss recent trends and future innovations in these technologies. The goal of the conference is to advance knowledge by enabling the exchange of information concerning advanced and emerging nanofabrication and nanomanufacturing topics and how they enable traditional and novel applications.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Inclusive photon production at forward rapidities in pp and p–Pb collisions at $\sqrt{{{s}}_{\textrm{NN}}}={5.02}$ TeV

A study of multiplicity and pseudorapidity distributions of inclusive photons measured in pp and p–Pb collisions at a center-of-mass energy per nucleon–nucleon collision of $\sqrt{s_{NN}}$ = 5.02 TeV using the ALICE detector in the forward pseudorapidity region 2.3 < η lab < 3.9 is presented. Measurements in p–Pb collisions are reported for two beam configurations in which the directions of the proton and lead ion beam were reversed. The pseudorapidity distributions in p–Pb collisions are obtained for seven centrality classes which are defined based on different event activity estimators, i.e., the charged-particle multiplicity measured at midrapidity as well as the energy deposited in a calorimeter at beam rapidity. The inclusive photon multiplicity distributions for both pp and p–Pb collisions are described by double negative binomial distributions. The pseudorapidity distributions of inclusive photons are compared to those of charged particles at midrapidity in pp collisions and for different centrality classes in p–Pb collisions. The results are compared to predictions from various Monte Carlo event generators. None of the generators considered in this paper reproduces the inclusive photon multiplicity distributions in the reported multiplicity range. The pseudorapidity distributions are, however, better described by the same generators.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Cooling plate assembly for plasma windows positioned in a beam accelerator system

A beam accelerator system operable to produce a medical isotope, including an ion accelerator that generates an ion beam; a low-pressure chamber; an anode adjacent and fluidly connected to the low-pressure chamber; a plasma window adjacent and fluidly connected to the anode; and a cathode housing adjacent and fluidly connected to the plasma window. The plasma window has a plurality of plates, each plate having an aperture that is aligned with an aperture in one or more adjacent plates to form a plasma channel. One or more plates in the plurality of plates includes a unitary plate having an aperture therein, and one or more cooling channels entering the unitary plate at a first side of the unitary plate and exiting the unitary plate at a second side of the unitary plate. The one or more cooling channels run through a thickness of the unitary plate.

Gribb, Tye↗

Laser beam pointing stabilization using analog position-sensitive diodes

Laser wire scanners have been used for ion beam profile and emittance measurements at the Spallation Neutron Source linear accelerator. Due to propagation distances exceeding 100 m, reliable measurements require laser beam stabilization, previously accomplished with a feedback control loop using a digital camera as a position sensor [Hardin et al., Opt. Express 19, 2874 (2011)]. Here, this paper presents an upgraded pointing stabilization system utilizing analog position-sensitive diodes (PSDs) as the position detector, optimized with an optical diffuser. The new system significantly surpasses the previous system by offering an order-of-magnitude improvement in radiation tolerance and a bandwidth limited only by the burst repetition rate of the laser beam. Operating with a 60-Hz burst mode laser, the new system effectively suppresses laser beam drifts up to 30 Hz, compared to the previous system’s 4 Hz limit. In addition, the amplitude of spectral components below 0.1 Hz was reduced by a factor of more than 100, which is over seven times greater than was achieved by the previous system.

Data acquisition↗

Resonance Ionization Spectroscopy Experiment at Facility for Rare Isotope Beams

This manuscript reports on the commissioning of the Resonance Ionization Spectroscopy Experiment (RISE) at the BEam COoler and LAser spectroscopy (BECOLA) facility at Facility for Rare Isotope Beams (FRIB). The instrument implements the collinear resonance ionization spectroscopy technique for sensitive measurements of isotope shifts and hyperfine structure of short-lived isotopes produced at FRIB. The existing BECOLA beamline was extended to integrate an electrostatic ion-beam bender and an ion detector at ultrahigh vacuum. An injection-seeded titanium-sapphire laser and a multiharmonic pulsed neodymium-doped yttrium aluminum garnet laser were installed to perform resonant excitation and selective ionization. Commissioning tests were performed to demonstrate the capabilities of the instrument by measuring the hyperfine structure of stable 27 Al produced in an offline ion source. The RISE instrument is ready and operational for future studies of short-lived isotopes at FRIB.

Atomic spectra↗

Under the microscope: Reduced activation ferritic martensitic steel Eurofer-97 following ion-Irradiation and high-temperature high-pressure water exposure

Here, this study is designed to characterise the microstructural behaviour of Eurofer-97 steel under ion irradiation and subsequent exposure to high-temperature high-pressure (HTHP) water. Eurofer-97, a ferritic-martensitic steel, has been developed to withstand the conditions of fusion reactors in the locations in contact with coolant with an elevated level of neutron flux, such as the breeder-wall blanket. The material has been studied after self-ion irradiation (using Fe ions) simulating the microstructural effects of neutron irradiation limited to the subsurface layer. The corrosion properties of the Eurofer-97 steel were studied by exposure to HTHP water up to 331 °C. Advanced microstructural characterisation using scanning, transmission electron and focused ion beam microscopy was performed on the as-received microstructure and after ion irradiation. This was then characterised after exposure for 240 h in high-temperature water. Eurofer-97 had a dense, columnar Cr-rich inner oxide, followed by a Fe-rich outer oxide layer. In the irradiated condition the grain structure and oxide itself was less ordered. No appreciable difference in oxide thickness was identified between the irradiated and unirradiated specimens after this short exposure time.

36 MATERIALS SCIENCE↗