Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “IMPLANTS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

SU-E-J-257: Image Artifacts Caused by Implanted Calypso Beacons in MRI Studies

Purpose: The presence of Calypso Beacon-transponders in patients can cause artifacts during MRI imaging studies. This could be a problem for post-treatment follow up of cancer patients using MRI studies to evaluate metastasis and for functional imaging studies.This work assesses (1) the volume immediately surrounding the transponders that will not be visualized by the MRI due to the beacons, and (2) the dependence of the non-visualized volume on beacon orientation, and scanning techniques. Methods: Two phantoms were used in this study (1) water filled box, (2) and a 2300 cc block of pork meat. Calypso beacons were implanted in the phantoms both in parallel and perpendicular orientations with respect to the MR scanner magnetic field. MR image series of the phantom were obtained with on a 1.0T high field open MR-SIM with multiple pulse sequences, for example, T1-weighted fast field echo and T2-weighted turbo spin echo. Results: On average, a no-signal region with 2 cm radius and 3 cm length was measured. Image artifacts are more significant when beacons are placed parallel to scanner magnetic field; the no-signal area around the beacon was about 0.5 cm larger in orthogonal orientation. The no-signal region surrounding the beacons slightly varies in dimension for the different pulse sequences. Conclusion: The use of Calypso beacons can prohibit the use of MRI studies in post-treatment assessments, especially in the immediate region surrounding the implanted beacon. A characterization of the MR scanner by identifying the no-signal regions due to implanted beacons is essential. This may render the use of Calypso beacons useful for some cases and give the treating physician a chance to identify those patients prior to beacon implantation.

60 APPLIED LIFE SCIENCES↗

Photoluminescence in silicon implanted with silicon ions at amorphizing doses

Luminescent and structural properties of n-FZ-Si and n-Cz-Si implanted with Si ions at amorphizing doses and annealed at 1100 Degree-Sign C in a chlorine-containing atmosphere have been studied. An analysis of proton Rutherford backscattering spectra of implanted samples demonstrated that an amorphous layer is formed, and its position and thickness depend on the implantation dose. An X-ray diffraction analysis revealed that defects of the interstitial type are formed in the samples upon annealing. Photoluminescence spectra measured at 78 K and low excitation levels are dominated by the dislocation-related line D1, which is also observed at 300 K. The peak position of this line, its full width at half-maximum, and intensity depend on the conduction type of Si and implantation dose. As the luminescence excitation power is raised, a continuous band appears in the spectrum. A model is suggested that explains the fundamental aspects of the behavior of the photoluminescence spectra in relation to the experimental conditions.

36 MATERIALS SCIENCE↗

Formation of Precipitates in Si Implanted with {sup 64}Zn{sup +} and {sup 16}O{sup +} Ions

The results of studying the surface Si layer and precipitate formation in CZ n-Si(100) samples sequentially implanted with {sup 64}Zn{sup +} ions with a dose of 5 × 10{sup 16} cm{sup 2} and energy of 100 keV and {sup 16}O{sup +} ions with the same dose but an energy of 33 keV at room temperature so that their projection paths R{sub p} = 70 nm would coincide are presented. The post-implantation samples are annealed for 1 h in an inert Ar medium in the temperature range of 400–900°C with a step of 100°C. The profiles of the implanted impurities are studied by time-of-flight secondary ion mass spectrometry. The Si surface is visualized using a scanning electron microscope, while the near-surface layer is visualized with the help of maps of elements formed by Auger electron spectroscopy with profiling over depth. The ZnO(002) texture is formed in an amorphized Si layer after the implantation of Zn and O ions. ZnO(102) crystallites of 5 nm in size are found in a recrystallized single-crystalline Si layer after annealing in Ar at 700°C.

36 MATERIALS SCIENCE↗

Dislocation-Related Photoluminescence in Silicon Implanted with Germanium Ions

The influence exerted by the conditions of the post-implantation annealing of silicon implanted with germanium ions on how luminescence centers are formed is studied. Measurements by the technique of the Rutherford backscattering of medium- and high-energy ions demonstrates that implantation with 1-MeV germanium ions at a dose of 1.5 × 10{sup 14} cm{sup –2} does not lead to the amorphization of single-crystal silicon. It is found that subsequent high-temperature annealing of the implanted samples in a chlorine-containing atmosphere at a temperature of 1100°C for 0.5–1.5 h gives rise to so-called D1 and D2 dislocation-related luminescence lines with wavelengths of 1.54 and 1.42 μm. With increasing annealing duration, the intensity of the D1 line decreases and that of D2 remains constant, but the D1 line dominates in all the spectra. The possible factors responsible for a decrease in the intensity of the D1 line and, in particular, the diffusion of germanium atoms and the formation of a silicon–germanium solid solution are discussed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A comparison of single-suture and double-suture incision closures in seaward-migrating juvenile Chinook salmon implanted with acoustic transmitters: implications for research in river basins containing hydropower structures

Reductions in the size of acoustic transmitters implanted in migrating juvenile salmonids have resulted in the ability to make shorter incisions that may warrant using only a single suture for closure. However, it is not known if one suture will sufficiently hold the incision closed, particularly when outward pressure is placed on the surgical site such as when migrating fish experience pressure changes associated with passage at hydroelectric dams. The objective of this research was to evaluate the effectiveness of single-suture incision closures on juvenile Chinook salmon (Oncorhynchus tshawytscha). Juvenile Chinook salmon were surgically implanted with a 2012 Juvenile Salmon Acoustic Telemetry System (JSATS) transmitter (0.30 g) and a passive integrated transponder tag (0.10 g) and incisions were closed with either one suture or two sutures. Mortality and tag retention were monitored and fish were examined after 7 and 14 days to evaluate tissue responses. In a separate experiment, surgically implanted fish were exposed to simulated turbine passage and then examined for expulsion of transmitters, expulsion of viscera through the incision, and mortal injury. With incisions closed using a single suture, there was no mortality or tag loss and similar or reduced tissue reaction compared to incisions closed with two sutures. Further, surgery time was significantly reduced when one suture was used, which leads to less handling and reduced stress. No tags were expelled during pressure scenarios and expulsion of viscera only occurred in two non-mortally injured fish (5%) with single sutures that were also exposed to very high pressure changes. No viscera expulsion was present in fish exposed to pressure scenarios likely representative of hydroturbine passage at many Columbia River dams (e.g. <2.7 ratio of pressure change; an acclimation pressure of 146.2 absolute kpa and a lowest exposure pressure of ~ 53.3 absolute kpa). Based on these results, we recommend the use of a single suture for surgical implantation of transmitters with incisions that are approximately 5 1/2 mm long after tag insertion.

Brown, Richard S.↗

The Efficacy of Ultraviolet Radiation for Sterilizing Tools Used for Surgically Implanting Transmitters into Fish

Telemetry is frequently used to examine the behavior of fish, and the transmitters used are normally surgically implanted into the coelom of fish. Implantation requires the use of surgical tools such as scalpels, forceps, needle holders, and sutures. When several fish are implanted consecutively for large telemetry studies, it is common for surgical tools to be sterilized or, at minimum, disinfected between each use so that pathogens that may be present are not spread among fish. However, autoclaving tools can take a long period of time, and chemical sterilants or disinfectants can be harmful to both humans and fish and have varied effectiveness. Ultraviolet (UV) radiation is commonly used to disinfect water in aquaculture facilities. However, this technology has not been widely used to sterilize tools for surgical implantation of transmitters in fish. To determine its efficacy for this application, Pacific Northwest National Laboratory researchers used UV radiation to disinfect surgical tools (i.e., forceps, needle holder, stab scalpel, and suture) that were exposed to one of four aquatic organisms that typically lead to negative health issues for salmonids. These organisms included Aeromonas salmonicida, Flavobacterium psychrophilum, Renibacterium salmoninarum, and Saprolegnia parasitica. Surgical tools were exposed to the bacteria by dipping them into a confluent suspension of three varying concentrations (i.e., low, medium, high). After exposure to the bacterial culture, tools were placed into a mobile Millipore UV sterilization apparatus. The tools were then exposed for three different time periods—2, 5, or 15 min. S. parasitica, a water mold, was tested using an agar plate method and forceps-pinch method. UV light exposures of 5 and 15 min were effective at killing all four organisms. UV light was also effective at killing Geobacillus stearothermophilus, the organism used as a biological indicator to verify effectiveness of steam sterilizers. These techniques appear to provide a quick alternative disinfection technique for some surgical tools that is less harmful to both humans and fish while not producing chemical waste. However, we do not recommend using these methods with tools that have overlapping parts or other structures that cannot be directly exposed to UV light such as needle holders.

Walker, Ricardo W.↗

Radiation Modified Ion-Implanted Materials

The objective of this project, by BNL and PVI, is to develop radiation-modified materials like titanium, nickel, aluminum, steel, refractory metals and alloys by implanting them with ions. Ion implantation radically improves strength & friction resistance. The focus will be on components of products like jet engines & windmills. Example: implanting windmill parts subject to friction may greatly reduce operating costs. Currently, electric power from wind is a factor of 1.5 more costly than coal due to labor costs [frequent lubrication of parts involves stopping a windmill & opening its nacelle (enclosures)]. A 50% friction reduction through ion implantation of parts will reduce the need for lubricants and make wind-generated electricity cheaper than fossil fuel. Major PVI role is adapting laboratory experimental results into commercially viable industrial processes and marketing them.

36 MATERIALS SCIENCE↗

Nanostructures from hydrogen implantation of metals.

This study investigates a pathway to nanoporous structures created by hydrogen implantation in aluminum. Previous experiments for fusion applications have indicated that hydrogen and helium ion implantations are capable of producing bicontinuous nanoporous structures in a variety of metals. This study focuses specifically on hydrogen and helium implantations of aluminum, including complementary experimental results and computational modeling of this system. Experimental results show the evolution of the surface morphology as the hydrogen ion fluence increases from 10{sup 17} cm{sup -2} to 10{sup 18} cm{sup -2}. Implantations of helium at a fluence of 10{sup 18} cm{sup -2} produce porosity on the order of 10 nm. Computational modeling demonstrates the formation of alanes, their desorption, and the resulting etching of aluminum surfaces that likely drives the nanostructures that form in the presence of hydrogen.

08 HYDROGEN↗

Noninvasive Detection, Tracking, and Characterization of Aerogel Implants Using Diagnostic Ultrasound

Medical implants are routinely tracked and monitored using different techniques, such as MRI, X-ray, and ultrasound. Due to the need for ionizing radiation, the two former methods pose a significant risk to tissue. Ultrasound imaging, however, is non-invasive and presents no known risk to human tissue. Aerogels are an emerging material with great potential in biomedical implants. While qualitative observation of ultrasound images by experts can already provide a lot of information about the implants and the surrounding structures, this paper describes the development and study of two simple B-Mode image analysis techniques based on attenuation measurements and echogenicity comparisons, which can further enhance the study of the biological tissues and implants, especially of different types of biocompatible aerogels.

36 MATERIALS SCIENCE↗

Development of ion implanted gallium arsenide transistors

Techniques were developed for creating bipolar microwave transistors in GaAs by ion implantation doping. The electrical properties of doped layers produced by the implantation of the light ions Be, Mg, and S were studied. Be, Mg, and S are suitable for forming the relatively deep base-collector junction at low ion energies. The electrical characteristics of ion-implanted diodes of both the mesa and planar types were determined. Some n-p-n planar transistor structures were fabricated by implantation of Mg to form the base regions and Si to form the emitters. These devices were found to have reasonably good base-collector and emitter-base junctions, but the current gain beta was small. The low was attributable to radiative recombination in the base region, which was extremely wide.

Hunsperger, R.↗

An implantable blood pressure and flow transmitter.

A miniature totally implantable FM/FM telemetry system has been developed to simultaneously measure blood pressure and blood flow, thus providing an appreciation of the hemodynamics of the circulation to the entire body or to a particular organ. Developed for work with animal subjects, the telemetry system's transmission time is controlled by an RF signal that permits an operating life of several months. Pressure is detected by a miniature intravascular transducer and flow is detected by an extravascular interferometric ultrasonic technique. Both pressure and flow are calibrated prior to implanting. The pressure calibration can be checked after the implanting by cannulation; flow calibration can be verified only at the end of the experiment by determining the voltage output from the implanted sensing system as a function of several measured flow rates. The utility of this device has been established by its use in investigating canine renal circulation during exercise, emotional encounters, administration of drugs, and application of accelerative forces.

Rader, R. D.↗

Corrosion and fatigue of surgical implants

Implants for the treatment of femoral fractures, mechanisms leading to the failure or degradation of such structures, and current perspectives on surgical implants are discussed. Under the first heading, general usage, materials and procedures, environmental conditions, and laboratory analyses of implants after service are considered. Corrosion, crevice corrosion, stress corrosion cracking, intergranular corrosion, pitting corrosion, fatigue, and corrosion fatigue are the principal degradation mechanisms described. The need for improvement in the reliability of implants is emphasized.

Lisagor, W. B.↗

Radiation hardened PMOS process with ion implanted threshold adjust

By including specific process modifications the effect of ion implantation on radiation hardness can be minimized and radiation hard ion implanted MOS circuits can be fabricated. The experimental procedure followed was to examine key processing steps (with respect to radiation hardness) on ion-implanted individual PMOS transistors. The individual transistors were evaluated by continuously monitoring the threshold voltage as the transistors were being irradiated. By comparing runs it was possible to deduce what is considered a radiation hard ion implanted process. Tests with a complex LSI PMOS IC processor chip containing over 2000 transistors and resistors were also conducted

Jhabvala, M.↗

Tribological characteristics of nitrogen (N+) implanted iron

The effect of implantation of nitrogen ions (1.5 MeV) on the friction and wear characteristics of pure ion sliding against M-50 steel (unimplanted) was studied in a pin-on-disk sliding friction apparatus. Test conditions included room temperature (25 C), a dry air atmosphere, a load of 1/2 kg (4.9 N), sliding velocities of 0.043 to 0.078 m/sec (15 to 25 rpm), a pure hydrocarbon lubricant (n-hexadecane), or a U.S.P. mineral oil and nitrogen ion implantation doses of 5x10 to the 15th power and 5x10 to the 17th power ions/sq cm. No differences in wear rates were observed in the low dose experiments. In the high dose experiments, small reductions in initial (40 percent) and steady state (20 percent) wear rates were observed for nitrogen implanted iron riders as compared with unimplanted controls. No differences in average friction coefficients were noted for either dose. Auger electron spectroscopy combined with argon ion bombardment revealed a subsurface Gaussian nitrogen distribution with a maximum concentration of 6 atomic percent at a depth of 0.8 microns. Similar analysis within the wear scar of an implanted rider after 20 microns of wear yielded only background nitrogen concentration. No inward migration of nitrogen ions was observed.

Jones, W. R.↗

Tribological characteristics of nitrogen (N+) implanted iron

The effect of implantation of nitrogen ions (1.5 MeV) on the friction and wear characteristics of pure ion sliding against M-50 steel (unimplanted) was studied in a pin-on-disk sliding friction apparatus. Test conditions included room temperature (25 C), a dry air atmosphere, a load of 1/2 kg (4.9 N), sliding velocities of 0.043 to 0.078 m/sec (15 to 25 rpm), a pure hydrocarbon lubricant (n-hexadecane), or a U.S.P. mineral oil and nitrogen ion implantation doses of 5x10 to the 15th power and 5x10 to the 17th power ions/sq cm. No differences in wear rates were observed in the low dose experiments. In the high dose experiments, small reductions in initial (40 percent) and steady state (20 percent) wear rates were observed for nitrogen implanted iron riders as compared with unimplanted controls. No differences in average friction coefficients were noted for either dose. Auger electron spectroscopy combined with argon ion bombardment revealed a subsurface Gaussian nitrogen distribution with a maximum concentration of 6 atomic percent at a depth of 0.8 microns. Similar analysis within the wear scar of an implanted rider after 20 microns of wear yielded only background nitrogen concentration. No inward migration of nitrogen ions was observed. Previously announced in STAR as N82-24322

Jones, W. R., Jr.↗

Retention of ion-implemented-xenon in olivine - Dependence on implantation dose

The diffusion of Xe in olivine, a major mineral in both meteorites and linear samples, was studied. Xe ions were implanted at 200 keV into single-crystal synthetic-forsterite targets and the depth profiles were measured by alpha particle backscattering before and after annealing for 1 hour at temperatures up to 1500 C. The fraction of implanted XE retained following annealing was strongly dependent on the implantation dose. Maximum retention of 100 percent occurred for an implanting dose of 3 x 10 to the 15th power Xe ions/sq cm. Retention was less at lower doses, with approximately more than or = 50 percent loss at one hundred trillion Xe ions/sq cm. Taking the diffusion coefficient at this dose as a lower limit, the minimum activation energy necessary for Xe retention in a 10 micrometer layer for ten million years was calculated as a function of metamorphic temperature. Previously announced in STAR as N83-18528

Melcher, C. L.↗

Development of ion-implantation confined, shallow mesa stripe (Pn,Sn)Te/Pb(Te,Se) DH laser diodes

Preliminary results of a program to develop ion implantation confined, shallow mesa stripe (Pb,Sn)Te laser diodes are presented. The practicality of using a shallow mesa stripe to produce single mode laser output and to increase the single mode tuning range are demonstrated. The first results of p-type ion implantation in the lead-tin salts are also reported. It is shown that sodium and lithium both can be used to convert n-type Pb(Te,Se) to p-type. The implant and anneal procedures are described, and electrical characteristics of Li-implanted layers are presented.

Fonstad, C. G.↗

Study of the effects of implantation on the high Fe-Ni-Cr and Ni-Cr-Al alloys

A theoretical study of the effects of implantation on the corrosion resistance of Fe-Ni-Cr and Ni-Cr-Al alloys was undertaken. The purpose was to elucidate the process by which corrosion scales form on alloy surfaces. The experiments dealt with Ni implanted with Al, exposed to S at high temperatures, and then analyzed using scanning electron microscopy, scanning Auger spectroscopy and X-ray fluorescence spectroscopy. Pair bonding and tight-binding models were developed to study the compositions of the alloys and as a result, a new surface ordering effect was found which may exist in certain real alloys. With these models, the behavior of alloy constituents in the presence of surface concentrations of O or S was also studied. Improvements of the models to take into account the important effects of long- and short-range ordering were considered. The diffusion kinetics of implant profiles at various temperatures were investigated, and it was found that significant non-equilibrium changes in the profiles can take place which may affect the implants' performance in the presence of surface contaminants.

Ribarsky, M. W.↗