Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Hg”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Isotopic anomalies and proton irradiation in the early solar system

Nuclear cross sections relevant to the various isotopic-abundance anomalies found in solar-system objects are evaluated in an attempt to set constraints on the hypothesized mechanism of irradiation of forming planetesimals by energetic protons from the young sun. A power-law proton spectrum is adopted, attention is restricted to proton energies less than about 20 MeV, and average cross sections are calculated for several reactions that might be expected to lead to the observed anomalies. The following specific anomalies are examined in detail: Al-26, Na-22, Xe-126, I-129, Kr-80, V-50, Nb-92, La-138, Ta-180, Hg-196, K-40, Ar-36, O-17, O-18, N-15, C-13, Li, Be, and B. It is suggested that the picture of presolar-grain carriers accounts for the facts more naturally than do irradiation models.

Clayton, D. D.↗

Left ventricular function during lower body negative pressure

The response of the human left ventricle to lower body negative pressure (LBNP) and the relation between left ventricular function and hemodynamic response were investigated. Ventricular function curves relating stroke volume to end-diastolic volume were obtained in 12 normal men. Volume data were derived from echocardiographic measurements of left ventricular end-systolic and end-diastolic diameters at rest and during lower body negative pressure (LBNP) at minus 40 mm Hg. End-diastolic volume decreased by 19% and stroke volume by 22%. There were no significant changes in heart rate, arterial blood pressure, or end-systolic volume. Thus, moderate levels of LBNP significantly reduce preload and stroke volume without affecting contractile state. The absence of significant changes in heart rate and arterial blood pressure in the presence of a significant reduction in stroke volume is consistent with an increase in systemic peripheral resistance mediated by low-pressure baroreceptors.

Ahmad, M.↗

Development of a three-man preprototype CO2 collection subsystem for spacecraft application

Future long-duration manned space missions will require regenerable carbon dioxide (CO2) collection concepts such as the Electrochemical Depolarized CO2 Concentrator (EDC). A three-man-capacity preprototype CO2 Collection Subsystem (CS-3) is being developed for eventual flight demonstration as part of the Air Revitalization System (ARS) of the Regenerative Life Support Evaluation (RLSE) experiment. The CS-3 employs an EDC to concentrate CO2 from the low partial-pressure levels required of spacecraft atmospheres to high partial-pressure levels needed for oxygen (O2) recovery through CO2 reduction processes. The CS-3 is sized to remove a nominal 3.0 kg/day (6.6 lb/day) of the CO2 to maintain the CO2 partial pressure (pCO2) of the cabin atmosphere at 400 Pa (3 mm Hg) or less. This paper presents the preprototype design, configuration, operation, and projected performance characteristics.

Schubert, F. H.↗

Mechanical properties of ion-beam-textured surgical implant alloys

An electron-bombardment Hg ion thruster was used as an ion source to texture surfaces of materials used to make orthopedic and/or dental prostheses or implants. The materials textured include 316 stainless steel, titanium-6% aluminum, 4% vanadium, and cobalt-20% chromium, 15% tungsten. To determine the effect of ion texturing on the ultimate strength and yield strength, stainless steel and Co-Cr-W alloy samples were tensile tested to failure. Three types of samples of both materials were tested. One type was ion-textured (the process also heats each sample to 300 C), another type was simply heated to 300 C in an oven, and the third type was untreated. Stress-strain diagrams, 0.2% offset yield strength data, total elongation data, and area reduction data are presented. Fatigue specimens of ion textured and untextured 316 stainless steel and Ti-6% Al-4% V were tested. Included as an ion textured sample is a Ti-6% Al-4% V sample which was ion machined by means of Ni screen mask so as to produce an array of 140 mu m x 140 mu m x 60 mu m deep pits. Scanning electron microscopy was used to characterize the ion textured surfaces.

Weigand, A. J.↗

Specialized physiological studies in support of manned space flight

Breath-by-breath measurements of pulmonary capillary O2 transfer and ventilation with a box-balloon spirometer and mass spectrometer were made on 3 subjects before, during and after 10 min of lower body negative pressure (LBNP) at -20, -40 and -60 Torr with arterial samples at -60 Torr. Deficits in blood O2 stores (O2B) were noted during LBNP with repayment of O2B during recovery being related to the intensity of LBNP stress. Concurrent calf volume, measured with a Hg strain gauge, decreased towards baseline well before the peak rise in pulmonary capillary O2 transfer after the release of LBNP which signified that O2B changes were related to blood volume shifts. The return of O2-depleted pooled blood to the central circulation during the first min. of recovery caused significant stress-related hyperpnea which peaked near 30 sec. and returned to near baseline after the first min. Three-compartment lung model analyses indicated an increase in the ventilated unperfused lung fraction from 0.09 to 0.17 with the effective compartment decreasing from 0.83 to 0.77. It appears that the 30% increase in ventilation equivalent was primarily the result of less effective lung perfusion during the LBNP.

Source record↗

Influence of central venous pressure upon sinus node responses to arterial baroreflex stimulation in man

Measurements were made of sinus node responses to arterial baroreceptor stimulation with phenylephrine injection or neck suction, before and during changes of central venous pressure provoked by lower body negative pressure or leg and lower truck elevation. Variations of central venous pressure between 1.1 and 9.0 mm Hg did not influence arterial baroreflex mediated bradycardia. Baroreflex sinus node responses were augmented by intravenous propranolol, but the level of responses after propranolol was comparable during the control state, lower body negative pressure, and leg and trunk elevation. Sinus node responses to very brief baroreceptor stimuli applied during the transitions of central venous pressure also were comparable in the three states. The authors conclude that physiological variations of central venous pressure do not influence sinus node responses to arterial baroreceptor stimulation in man.

Mark, A. L.↗

Development of a prototype regeneration carbon dioxide absorber

A prototype regenerable carbon dioxide absorber was developed to maintain the environmental quality of the portable life support system. The absorber works on the alkali metal carbonate-bicarbonate solid-gas reaction to remove carbon dioxide from the atmosphere. The prototype sorber module was designed, fabricated, and tested at simulated extravehicular activity conditions to arrive at optimum design. The unit maintains sorber outlet concentration below 5 mm Hg. An optimization study was made with respect to heat transfer, temperature control, sorbent utilization, sorber life and regenerability, and final size of the module. Important parameters influencing the capacity of the final absorber unit were identified and recommendations for improvement were made.

Patel, P. S.↗

Limb Infrared Monitor of the Stratosphere /LIMS/ experiment

The Limb Infrared Monitor of the Stratosphere (LIMS) radiometer is a satellite-borne six-channel multispectral scanning radiometer using a two-stage methane and ammonia solid-cryogen cooler to cool the (Hg, Cd)Te focal plane to 65 K. The LIMS experiment employs thermal IR limb sounding to provide vertical-profile measurement of temperature and of concentrations of O3, NO3, and H2O in the stratosphere on a global scale. The goals of the experiment and the expected accuracies of the measurements are outlined, and the radiance measured by the radiometer is analyzed. A program of correlative measurements designed for verification and augmentation of the LIMS data is discussed. Detailed descriptions are given of the LIMS components and optics, the detector capsule assembly, the solid-cryogen cooler, the four operational modes of the LIMS system, and the data-processor electronics. It is noted that prelaunch acceptance testing thus far completed indicates that the LIMS specification design requirements have been met, and the experiment's performance goals can be achieved.

Drozewski, R. W.↗

Effective core potentials for the cadmium and mercury atoms

Ab initio effective core potentials have been obtained for the cadmium and mercury atoms by the methods of Kahn et al. (1976). Both two and twelve valence electron representations of Cd and Hg were tested for various atom state-configurations by comparison with all-electron calculations. The generated potentials were used to obtain the equilibrium bond distances and molecular binding energies for the dichloride and dimethyl compounds of both atoms from single and optimum-double configuration self-consistent field calculations.

Basch, H.↗

Wind-tunnel investigation of the thrust augmentor performance of a large-scale swept wing model

Tests were made in the Ames 40- by 80-foot wind tunnel to determine the forward speed effects on wing-mounted thrust augmentors. The large-scale model was powered by the compressor output of J-85 driven viper compressors. The flap settings used were 15 deg and 30 deg with 0 deg, 15 deg, and 30 deg aileron settings. The maximum duct pressure, and wind tunnel dynamic pressure were 66 cmHg (26 in Hg) and 1190 N/sq m (25 lb/sq ft), respectively. All tests were made at zero sideslip. Test results are presented without analysis.

Koenig, D. G.↗

Moderate temperature detector development

The development of (Hg, Cd)Te detectors for 8 to 12 micrometer wavelength regions capable of achieving significantly improved sensitivity at noncryogenic temperatures is discussed.

Sood, A. K.↗

Mass effects on angular distribution of sputtered atoms

Sputtering metal targets at low ion energies (Hg or Ar at less than 300 eV) under normal ion incidence causes the lighter atoms (lighter isotopes or lighter elements of alloys) to be preferentially ejected in a direction normal to the target surface. Experimental results are shown for several elements and alloys at various bombardment energies. The amount of enrichment of the lighter species normal to the target surface decreases quite rapidly with increasing ion energy. The phenomenon is a result of reflective collisions because lighter atoms can be backscattered from heavier ones underneath but not vice versa. The effect provides an explanation of why solar-wind-exposed lunar material is enriched in the heavier isotopes, since sputtered lower-mass elements have a higher chance of achieving the lunar escape velocity.

Olson, R. R.↗

Specific spacecraft evaluation: Special report

Charged and neutral particle transport from an 8 cm mercury ion thruster to the surfaces of the P 80-1 spacecraft and to the Teal Ruby sensor and the ECOM-501 sensor of that spacecraft were investigated. Laboratory measurements and analyses were used to examine line-of-sight and nonline-of sight particle transport modes. The recirculation of Hg(+) ions in the magnetic field of the earth was analyzed for spacecraft velocity and Earth magnetic field vector configurations which are expected to occur in near Earth, circular, high inclination orbits. For these magnetic field and orbit conditions and for expected ion release distribution functions, in both angles and energies, the recirculation/re-interception of ions on spacecraft surfaces was evaluated. The refraction of weakly energetic ions in the electric fields of the thruster plasma plume and in the electric fields between this plasma plume and the material boundaries of the thruster, the thruster sputter shield, and the various spacecraft surfaces were examined. The neutral particle transport modes of interest were identified as sputtered metal atoms from the thruster beam shield. Results, conclusions, and future considerations are presented.

Sellen, J. M., Jr.↗

A fundamental study of liquid spray evaporation at a heated surface

The influence of feedwater temperature and the influence of pulsing nozzle flow on the heat transfer characteristics in the spray evaporative cooling process were investigated. A commercial water circulation heater was installed in the feedwater line between the supply reservoir and the nozzle. A pass through the heater provided water at temperatures up to 50 C at the nozzle; higher temperatures were obtained by multiple heater passes. A thermocouple installed in the water line just upstream of the nozzle provided a measure of the feedwater temperature. Initial tests were run with belljar exhaust orifice number two which provided a pressure in a range about 7mm Hg abs. The feedwater temperature was heated to a temperature of 45 C. Results indicate that for a given system operating pressure, there is an upper limit on the feedwater temperature above which the spray will flash to vapor before hitting the surface to be cooled.

Wierum, F. A.↗

Cloud Top Scanning radiometer (CTS)

A scanning radiometer to be used for measuring cloud radiances in each of three spectral regions is described. Significant features incorporated in the Cloud Top Scanner design are: (1) flexibility and growth potential through use of easily replaceable modular detectors and filters; (2) full aperture, multilevel inflight calibration; (3) inherent channel registration through employment of a single shared field stop; and (4) radiometric sensitivity margin in a compact optical design through use of Honeywell developed (Hg,Cd)Te detectors and preamplifiers.

Source record↗

Dynamics of erythrocyte count, hemoglobin, and catalase activity in rat blood in hypokinesia, muscular activity and restoration

Tests were conducted to prove that muscular exertion (in this instance swimming) of different duration and intensity, as well as hypodynamia, result in an increase of hemoglobin and number of red blood cells in peripheral blood rats. Catalase activity increased with an increase in the duration of swimming, but only up to 6 hr; with 7-9 hr of swimming as well as in hypodynamia, catalase activity decreased. It was also observed that under hypodynamia as well as in 3, 5 and 6 hr exertion (swimming) the color index of blood decreased. Pressure chamber treatment (for 8 min each day for one week), alternating a 2 min negative pressure up to 35 mm Hg with 1 min positive pressure, increased the erythrocyte count and hemoglobin content.

Taneyeva, G. V.↗

MARS 1414 recorder environmental tests

Environmental testing is described and the data of the Modular Airborne Recording System (MARS) 1414 is presented. The preliminary data marks a starting point for more complete thermal testing in the future. The unit was operated at +/-55 C at one atmosphere, -10 C at 75,000 feet (28 mm Hg)at the other. Temperatures at 13 locations on the unit were monitored and plotted against elapsed time. From the test results, some estimation can be made of ambient temperatures in which the heaters will operate and shut off. This data is sufficient to complete a preliminary analysis of the MARS 1414 Recorder, and to design further tests.

Langjahr, D.↗