Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “HELICITY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

S -duality and helicity amplitudes

We examine interacting Abelian theories at low energies and show that holomorphically normalized photon helicity amplitudes transform into dual amplitudes under SL(2, Z) as modular forms with weights that depend on the number of positive and negative helicity photons and on the number of internal photon lines. Moreover, canonically normalized helicity amplitudes transform by a phase, so that even though the amplitudes are not duality invariant, their squares are duality invariant. We explicitly verify the duality transformation at one loop by comparing the amplitudes in the case of an electron and the dyon that is its SL(2, Z) image, and extend the invariance of squared amplitudes order by order in perturbation theory. We demonstrate that S-duality is a property of all low-energy effective Abelian theories with electric and/or magnetic charges and see how the duality generically breaks down at high energies.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The crystal structure of the calcium-bound con-G[Q6A] peptide reveals a novel metal-dependent helical trimer

The ability to form and control both secondary structure and oligomerization in short peptides has proven to be challenging owing to the structural instability of such peptides. The conantokin peptides are a family of {gamma}-carboxyglutamic acid containing peptides produced in the venoms of predatory sea snails of the Conus family. They are examples of short peptides that form stable helical structures, especially in the presence of divalent cations. Both monomeric and dimeric conantokin peptides have been identified and represent a new mechanism of helix association, 'the metallozipper motif' that is devoid of a hydrophobic interface between monomers. In the present study, a parallel/antiparallel three-helix bundle was identified and its crystal structure determined at high resolution. The three helices are almost perfectly parallel and represent a novel helix-helix association. The trimer interface is dominated by metal chelation between the three helices, and contains no interfacial hydrophobic interactions. It is now possible to produce stable monomeric, dimeric, or trimeric metallozippers depending on the peptide sequence and metal ion. Such structures have important applications in protein design.

59 BASIC BIOLOGICAL SCIENCES↗

Long helical filaments are not seen encircling cells in electron cryotomograms of rod-shaped bacteria

Highlights: {yields} No long helical filaments are seen near or along rod-shaped bacterial inner membranes by electron cryo-tomography. {yields} Electron cryo-tomography has the resolution to detect single filaments in vivo. -- Abstract: How rod-shaped bacteria form and maintain their shape is an important question in bacterial cell biology. Results from fluorescent light microscopy have led many to believe that the actin homolog MreB and a number of other proteins form long helical filaments along the inner membrane of the cell. Here we show using electron cryotomography of six different rod-shaped bacterial species, at macromolecular resolution, that no long (>80 nm) helical filaments exist near or along either surface of the inner membrane. We also use correlated cryo-fluorescent light microscopy (cryo-fLM) and electron cryo-tomography (ECT) to identify cytoplasmic bundles of MreB, showing that MreB filaments are detectable by ECT. In light of these results, the structure and function of MreB must be reconsidered: instead of acting as a large, rigid scaffold that localizes cell-wall synthetic machinery, moving MreB complexes may apply tension to growing peptidoglycan strands to ensure their orderly, linear insertion.

60 APPLIED LIFE SCIENCES↗

Helical dislocation in twisted bilayer graphene

Here, we observe helical dislocation network in twisted bilayer graphene (tBLG), which is accompanied by large out-of-plane deformation. By atomistic calculations, we demonstrate two distinct out-of-plane deformation modes, breathing mode with small out-of-plane deformation and bending mode with one order larger corrugation magnitude compared to the breathing mode. The out-of-plane deformation is caused by inhomogeneous interlayer coupling resulting from the periodic stacking order of the tBLG moiré superlattice. Instead of commonly observed screw dislocation in tBLG, we demonstrate a slip-induced helical dislocation network in the bending mode tBLG. We show that bending mode deformation is more stable at low twist angles, as the energy savings due to interface energy exceeds the energy penalty due to the strain energy caused by the large out-of-plane deformation. Our work provides a detailed picture of a new helical dislocation structure in tBLG and establishes a direct connection between the dislocation and deformation. Therefore, understanding the dislocation mechanics of tBLG may open up the possibility to control the corrugation, and reveal an opportunity to tune the intriguing physical properties of twisted bilayer graphene.

36 MATERIALS SCIENCE↗

Predicting roughness effects in additively manufactured coolant channels with helical enhancements

Additive manufacturing (AM) is a promising technique for fabrication of complex geometries such as those expected to be utilized in the blanket, first wall, and divertor. In the case of cooling, metallic AM may be exploited to embed geometric enhancements (ribs, rifling, etc.) to improve cooling performance. However, due to the roughness of these unfinished internal AM surfaces, prediction of thermal hydraulic performance in such channels is difficult. In this work, we consider a methodology for predicting pressure drop and heat transfer in AM channels containing helical enhancements (e.g. helical ribs, twisted tapes) that allows the incorporation of roughness data through conventional pipe flow correlations. This methodology is tested using experimental friction factor and heat transfer coefficient data from high-pressure helium coolant flow measurements in AM stainless steel tubes fabricated by laser powder bed fusion. Both a featureless AM tube and one containing helical ribs were considered alongside a conventionally manufactured smooth tube. The AM surface roughness is obtained by profilometry and used to predict an equivalent sand-grain roughness, with this equivalent roughness confirmed through AM featureless tube measurements. Under the proposed methodology, this roughness information is incorporated into predictions of friction factor and Nusselt number for the rifled tube. Furthermore, these predictions agree well with experimental data across a large range of Reynolds numbers, encouraging the use of this methodology for thermal hydraulic analysis of similar systems and design of future coolant channel geometries.

Additive manufacturing↗

Respiratory-Gated Helical Computed Tomography of Lung: Reproducibility of Small Volumes in an Ex Vivo Model

Purpose: Motion-adapted radiotherapy with gated irradiation or tracking of tumor positions requires dedicated imaging techniques such as four-dimensional (4D) helical computed tomography (CT) for patient selection and treatment planning. The objective was to evaluate the reproducibility of spatial information for small objects on respiratory-gated 4D helical CT using computer-assisted volumetry of lung nodules in a ventilated ex vivo system. Methods and Materials: Five porcine lungs were inflated inside a chest phantom and prepared with 55 artificial nodules (mean diameter, 8.4 mm {+-} 1.8). The lungs were respirated by a flexible diaphragm and scanned with 40-row detector CT (collimation, 24 x 1.2 mm; pitch, 0.1; rotation time, 1 s; slice thickness, 1.5 mm; increment, 0.8 mm). The 4D-CT scans acquired during respiration (eight per minute) and reconstructed at 0-100% inspiration and equivalent static scans were scored for motion-related artifacts (0 or absent to 3 or relevant). The reproducibility of nodule volumetry (three readers) was assessed using the variation coefficient (VC). Results: The mean volumes from the static and dynamic inspiratory scans were equal (364.9 and 360.8 mm{sup 3}, respectively, p = 0.24). The static and dynamic end-expiratory volumes were slightly greater (371.9 and 369.7 mm{sup 3}, respectively, p = 0.019). The VC for volumetry (static) was 3.1%, with no significant difference between 20 apical and 20 caudal nodules (2.6% and 3.5%, p = 0.25). In dynamic scans, the VC was greater (3.9%, p = 0.004; apical and caudal, 2.6% and 4.9%; p = 0.004), with a significant difference between static and dynamic in the 20 caudal nodules (3.5% and 4.9%, p = 0.015). This was consistent with greater motion-related artifacts and image noise at the diaphragm (p <0.05). The VC for interobserver variability was 0.6%. Conclusion: Residual motion-related artifacts had only minimal influence on volumetry of small solid lesions. This indicates a high reproducibility of spatial information for small objects in low pitch helical 4D-CT reconstructions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Investigation of Accelerated Partial Breast Patient Alignment and Treatment With Helical Tomotherapy Unit

Purpose: To determine the precision of megavoltage computed tomography (MVCT)-based alignment of the seroma cavity for patients undergoing partial breast irradiation; and to determine whether accelerated partial breast irradiation (APBI) plans can be generated for TomoTherapy deliveries that meet the National Surgical Adjuvant Breast and Bowel Project (NSABP) B-39/Radiation Therapy Oncology Group (RTOG) 0413 protocol guidelines for target coverage and normal tissue dose limitations. Methods and Materials: We obtained 50 MVCT images from 10 patients. An interuser study was designed to assess the alignment precision. Using a standard helical and a fixed beam prototype ('topotherapy') optimizer, two APBI plans for each patient were developed. Results: The precision of the MVCT-based seroma cavity alignment was better than 2 mm if averaged over the patient population. Both treatment techniques could be used to generate acceptable APBI plans for patients that fulfilled the recommended NSABP B-39/RTOG-0413 selection criteria. For plans of comparable treatment time, the conformation of the prescription dose to the target was greater for helical deliveries, while the ipsilateral lung dose was significantly reduced for the topotherapy plans. Conclusions: The inherent volumetric imaging capabilities of a TomoTherapy Hi-Art unit allow for alignment of patients undergoing partial breast irradiation that is determined from the visibility of the seroma cavity on the MVCT image. The precision of the MVCT-based alignment was better than 2 mm ({+-} standard deviation) when averaged over the patient population. Using the NSABP B-39/RTOG-0413 guidelines, acceptable APBI treatment plans can be generated using helical- or topotherapy-based delivery techniques.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Early Clinical Experience and Outcome of Helical Tomotherapy for Multiple Metastatic Lesions

Purpose: To evaluate the feasibility of synchronous treatment of multiple metastatic lesions by helical tomotherapy. Methods and Materials: Forty-two patients with multiple metastatic lesions were treated by helical tomotherapy from April 2006 to February 2007. Among these patients, 21 had metastatic bone disease. Subjective pain response was assessed using the visual analogue scales, and morbidity was evaluated by Common Terminology Criteria for Adverse Events v3.0. The correlation between the percentage of red bone marrow in the radiation field and the severity of leukocytopenia was analyzed. Results: The median age was 57 years. Radiation dose to the gross tumor volume was 30-84 Gy, with a median fractional size of 3 Gy. Mean treatment time was 16 min and 1 sec. Treatment time and fraction size were modified because of poor performance status or hematologic toxicity in two patients. With regard to palliative effects for bone metastasis, 16 patients (76.2%) experienced positive pain relief. Four patients had Grade III leukocytopenia, and three had Grade IV leukocytopenia. In the multivariate logistic regression, red marrow percentage was the independent risk factor most associated with Grade III/IV leukocytopenia (p = 0.014). The tolerance cutoff point of red bone marrow was 26.8%, with a sensitivity and specificity of 85.7% and 85.7%, respectively. Conclusions: Helical tomotherapy was effective for symptom palliation and was feasible for patients with multiple metastatic diseases. The volume of red bone marrow, as well as performance status, must be taken into account to determine optimal treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Pediatric Craniospinal Axis Irradiation With Helical Tomotherapy: Patient Outcome and Lack of Acute Pulmonary Toxicity

Purpose: To present the patient outcomes and risk of symptomatic acute radiation pneumonitis (ARP) in 18 pediatric patients treated with helical tomotherapy to their craniospinal axis for a variety of neoplasms. Methods and Materials: A total of 18 patients received craniospinal axis irradiation with helical tomotherapy. The median age was 12 years (range, 2.5-21). The follow-up range was 3-48 months (median, 16.5). Of the 18 patients, 15 received chemotherapy in the neoadjuvant, adjuvant, or concomitant setting. Chemotherapy was tailored to the particular histologic diagnosis; 10 of 18 patients underwent surgical removal of the gross primary tumor. The patients were followed and evaluated for ARP starting at 3-6 months after completion of craniospinal axis irradiation. ARP was graded using the Common Toxicity Criteria, version 3. Results: At the last follow-up visit, 14, 2, and 2 patients were alive without disease, alive with disease, and dead of disease, respectively. The cause-specific survival rate was 89% (16 of 18), disease-free survival rate was 78% (14 of 18), and overall survival rate was 89% (16 of 18). No patient had treatment failure at the cribriform plate. No patient developed symptoms of ARP. Conclusion: Craniospinal axis irradiation using helical tomotherapy yielded encouraging patient outcomes and acute toxicity profiles. Although large volumes of the lung received low radiation doses, no patient developed symptoms of ARP during the follow-up period.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Concurrent Chemoradiotherapy With Helical Tomotherapy for Oropharyngeal Cancer: A Preliminary Result

Purpose: To review the experience with and evaluate the treatment plan for helical tomotherapy for the treatment of oropharyngeal cancer. Methods and Materials: Between November 1, 2006 and January 31, 2009, 10 histologically confirmed oropharyngeal cancer patients were enrolled. All patients received definitive concurrent chemoradiation with helical tomotherapy. The prescription dose to the gross tumor planning target volume, the high-risk subclinical area, and the low-risk subclinical area was 70Gy, 63Gy, and 56Gy, respectively. During radiotherapy, all patients were treated with cisplatin, 30mg/m{sup 2}, plus 5-fluorouracil (425mg/m{sup 2})/leucovorin (30mg/m{sup 2}) intravenously weekly. Toxicity of treatment was scored according to the Common Terminology Criteria for Adverse Events, version 3.0. Several parameters, including maximal or median dose to critical organs, uniformity index, and conformal index, were evaluated from dose-volume histograms. Results: The mean survival was 18 months (range, 7-22 months). The actuarial overall survival, disease-free survival, locoregional control, and distant metastasis-free rates at 18 months were 67%, 70%, 80%, and 100%, respectively. The average for uniformity index and conformal index was 1.05 and 1.26, respectively. The mean of median dose for right side and left side parotid glands was 23.5 and 23.9Gy, respectively. No Grade 3 toxicity for dermatitis and body weight loss and only one instance of Grade 3 mucositis were noted. Conclusion: Helical tomotherapy achieved encouraging clinical outcomes in patients with oropharyngeal carcinoma. Treatment toxicity was acceptable, even in the setting of concurrent chemotherapy. Long-term follow-up is needed to confirm these preliminary findings.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Treatment Planning for Pulsed Reduced Dose-Rate Radiotherapy in Helical Tomotherapy

Purpose: Pulsed reduced dose-rate radiotherapy (PRDR) is a valuable method of reirradiation because of its potential to reduce late normal tissue toxicity while still yielding significant tumoricidal effect. A typical method using a conventional linear accelerator (linac) is to deliver a series of 20-cGy pulses separated by 3-min intervals to give an effective dose-rate of just under 7 cGy/min. Such a strategy is fraught with difficulties when attempted on a helical tomotherapy unit. We investigated various means to overcome this limitation. Methods and Materials: Phantom and patient cases were studied. Plans were generated with varying combinations of field width (FW), pitch, and modulation factor (MF) to administer 200 cGy per fraction to the planning target in eight subfractions, thereby mimicking the technique used on conventional linacs. Plans were compared using dose-volume histograms, homogeneity indices, conformation numbers, and treatment time. Plan delivery quality assurance was performed to assess deliverability. Results: It was observed that for helical tomotherapy, intrinsic limitations in leaf open time in the multileaf collimator deteriorate plan quality and deliverability substantially when attempting to deliver very low doses such as 20-40 cGy. The various permutations evaluated revealed that the combination of small FW (1.0 cm), small MF (1.3-1.5), and large pitch ({approx}0.86), along with the half-gantry-angle-blocked scheme, can generate clinically acceptable plans with acceptable delivery accuracy ({+-}3%). Conclusion: Pulsed reduced dose-rate radiotherapy can be accurately delivered using helical tomotherapy for tumor reirradiation when the appropriate combination of FW, MF, and pitch is used.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Prospective Phase I-II Trial of Helical Tomotherapy With or Without Chemotherapy for Postoperative Cervical Cancer Patients

Purpose: To investigate, in a prospective trial, the acute and chronic toxicity of patients with cervical cancer treated with surgery and postoperative intensity-modulated radiotherapy (RT) delivered using helical tomotherapy, with or without the administration of concurrent chemotherapy. Patients and Methods: A total of 24 evaluable patients entered the study between March 2006 and August 2009. The indications for postoperative RT were tumor size, lymphovascular space invasion, and the depth of cervical stromal invasion in 15 patients; 9 patients underwent postoperative RT because of surgically positive lymph nodes. All patients underwent pelvic RT delivered with helical tomotherapy and intracavitary high-dose-rate brachytherapy. Treatment consisted of concurrent weekly platinum in 17, sequential carboplatin/Taxol in 1, and RT alone in 6. The patients were monitored for acute and chronic toxicity using the Common Toxicity Criteria, version 3.0. Results: The median follow-up was 24 months (range, 4-49). At the last follow-up visit, 23 patients were alive and disease free. Of the 24 patients, 12 (50%) experienced acute Grade 3 gastrointestinal toxicity (anorexia in 5, diarrhea in 4, and nausea in 3). One patient developed acute Grade 4 genitourinary toxicity (vesicovaginal fistula). For patients treated with concurrent chemotherapy, the incidence of acute Grade 3 and 4 hematologic toxicity was 71% and 24%, respectively. For patients treated without concurrent chemotherapy, the incidence of acute Grade 3 and 4 hematologic toxicity was 29% and 14%, respectively. Two long-term toxicities occurred (vesicovaginal fistula at 25 months and small bowel obstruction at 30 months). The overall and progression-free survival rate at 3 years for all patients was 100% and 89%, respectively. Conclusion: The results of our study have shown that postoperative external RT for cervical cancer delivered with helical tomotherapy and high-dose-rate brachytherapy and with or without chemotherapy is feasible, with acceptable acute and chronic toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Parotid Gland Sparing With Helical Tomotherapy in Head-and-Neck Cancer

Purpose: This study evaluated the ability of helical tomotherapy to spare the function of the parotid glands in patients with head-and-neck cancer by analyzing dose-volume histograms, salivary gland scintigraphy, and quality of life assessment. Methods and Materials: Data from 76 consecutive patients treated with helical tomotherapy (Hi-Art Tomotherapy) at University Hospital Brussel were analyzed. During planning, priority was given to planning target volume (PTV) coverage: {>=}95% of the dose must be delivered to {>=}95% of the PTV. Elective nodal regions received 54 Gy (1.8 Gy/fraction). A dose of 70.5 Gy (2.35 Gy/fraction) was prescribed to the primary tumor and pathologic lymph nodes (simultaneous integrated boost scheme). Objective scoring of salivary excretion was performed by salivary gland scintigraphy. Subjective scoring of salivary gland function was evaluated by the European Organization for Research and Treatment of Cancer quality of life questionnaires Quality of Life Questionnaire-C30 (QLQ-C30) and Quality of Life Questionnaire-Head and Neck 35 (H and N35). Results: Analysis of dose-volume histograms (DVHs) showed excellent coverage of the PTV. The volume of PTV receiving 95% of the prescribed dose (V95%) was 99.4 (range, 96.3-99.9). DVH analysis of parotid gland showed a median value of the mean parotid dose of 32.1 Gy (range, 17.5-70.3 Gy). The median parotid volume receiving a dose <26 Gy was 51.2%. Quality of life evaluation demonstrated an initial deterioration of almost all scales and items in QLQ-C30 and QLQ-H and N35. Most items improved in time, and some reached baseline values 18 months after treatment. Conclusion: DVH analysis, scintigraphic evaluation of parotid function, and quality of life assessment of our patient group showed that helical tomotherapy makes it possible to preserve parotid gland function without compromising disease control. We recommend mean parotid doses of <34 Gy and doses <26 Gy to a maximum 47% of the parotid volume as planning goals. Intensity-modulated radiotherapy should be considered as standard treatment in patients with head-and-neck cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Co-assembly of Zn(SPh){sub 2} and organic linkers into helical and zig-zag polymer chains

Two novel one-dimensional coordination polymers, single helicate [Zn(SPh){sub 2}(TPyTA)(EG)]{sub n} (EG=ethylene glycol) (1) and zig-zag structure [Zn(SPh){sub 2}(BPyVB)]{sub n} (2), were synthesized under solvothermal conditions at 150 Degree-Sign C or room temperature by the co-assembly of Zn(SPh){sub 2} and organic linkers such as 2,4,6-tri(4-pyridyl)-1,3,5-triazine (TPyTA) and 1,3-bis(trans-4-pyridylvinyl)benzene (BPyVB). X-ray crystallography study reveals that both polymers 1 and 2 crystallize in space group P2{sub 1}/c of the monoclinic system. The solid-state UV-vis absorption spectra show that 1 and 2 have maxium absorption onsets at 400 nm and 420 nm, respectively. TGA analysis indicates that 1 and 2 are stable up to 110 Degree-Sign C and 210 Degree-Sign C. - Graphical abstract: Two novel one-dimensional coordination polymers, single helicate [Zn(SPh){sub 2}(TPyTA)(EG)]{sub n} (1) and zig-zag structure [Zn(SPh){sub 2}(BPyVB)]{sub n} (2), were synthesized. Solid-state UV-vis absorptions show that 1 and 2 have maxium absorption onsets at 400 nm and 420 nm, respectively. TGA analysis indicates that 1 and 2 are stable up to 110 Degree-Sign C and 210 Degree-Sign C. Highlights: Black-Right-Pointing-Pointer Two novel one-dimensional coordination polymers have been synthesized. Black-Right-Pointing-Pointer TPyTA results in helical structures in 1 while BPyVB leads to zig-zag chains in 2. Black-Right-Pointing-Pointer Solid-state UV-vis absorption spectra and TGA analysis of the title polymers were studied.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A 3D chiral metal-organic framework based on left-handed helices containing 3-amino-1 H-1,2,4-triazole ligand

A chiral metal-organic framework, [Cu(atr)(OH)]·0.5H{sub 2}O·0.5en (1) (Hatr=3-amino-1 H-1,2,4-triazole, en=ethylenediamine), was constructed via diffusion reaction of the achiral Hatr ligand and CuSO{sub 4} as starting materials. Compound 1 crystallizes in the chiral space group P3{sub 2}21 and features a porous metal-organic framework with 44.1% solvent-accessible volume fabricated by left-handed helices with a pitch height of l{sub p}=10.442 Å. Six helices gather around in a cycle forming a large honeycomb channel with a 6.58 Å inner diameter. Cu(II) center and atr{sup ‒} ligand regarded as 3-connected nodes, compound 1 can be simplified to a 3-c uninodal (4.12{sup 2}) (qtz-h) topological network. A gradual decreasing in the magnetic moment depending on temperature decreasing indicates an antiferromagnetic interaction in 1. The powder XRD confirms the bulk sample is a single crystal pure phase, and the thermogravimetric analysis shows the thermal stability of 1 is up to ca. 240 °C. - Highlights: • The present 3D chiral MOF is built from achiral Hatr ligand. • Six left-handed helices gather into a honeycomb channel in chiral sp P3{sub 2}21. • Compound 1 shows a 3-c uninodal (4.12{sup 2}) or qtz-h topological network. • Compound 1 indicates an antiferromagnetic interaction.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Controllable synthesis of helical, straight, hollow and nitrogen-doped carbon nanofibers and their magnetic properties

Graphical abstract: The helical, straight and hollow carbon nanofibers can be selectively synthesized by adjusting either the reaction temperature or feed gas composition. Display Omitted Highlights: ► CNFs were synthesized via pyrolysis of acetylene on copper NPs. ► The helical, straight, hollow and N-doped CNFs can be selectively synthesized. ► The growth mechanism of different types of CNFs was proposed. -- Abstract: Carbon nanofibers (CNFs) with various morphologies were synthesized by catalytic pyrolysis of acetylene on copper nanoparticles which were generated from the in situ decomposition of copper acetylacetonate. The morphology of the pristine and acid-washed CNFs was investigated by field emission scanning electron microscope and high-resolution transmission electron microscope. Helical, straight and hollow CNFs can be selectively synthesized by adjusting either the reaction temperature or feed gas composition. The growth mechanism for these three types of CNFs was proposed.

36 MATERIALS SCIENCE↗

Adaptive Radiation Therapy for Localized Mesothelioma with Mediastinal Metastasis Using Helical Tomotherapy

The purpose of this study was to compare 2 adaptive radiotherapy strategies with helical tomotherapy. A patient having mesothelioma with mediastinal nodes was treated using helical tomotherapy with pretreatment megavoltage CT (MVCT) imaging. Gross tumor volumes (GTVs) were outlined on every MVCT study. Two alternatives for adapting the treatment were investigated: (1) keeping the prescribed dose to the targets while reducing the dose to the OARs and (2) escalating the target dose while maintaining the original level of healthy tissue sparing. Intensity modulated radiotherapy (step-and-shoot IMRT) and 3D conformal radiotherapy (3DCRT) plans for the patient were generated and compared. The primary lesion and nodal mass regressed by 16.2% and 32.5%, respectively. Adapted GTVs and reduced planning target volume (PTV) margins of 4 mm after 22 fractions decrease the planned mean lung dose by 19.4%. For dose escalation, the planned prescribed doses may be increased from 50.0 to 58.7 Gy in PTV{sub 1} and from 60.0 to 70.5 Gy in PTV{sub 2}. The step-and-shoot IMRT plan was better in sparing healthy tissue but did not provide target coverage as well as the helical tomotherapy plan. The 3DCRT plan resulted in a prohibitively high planned dose to the spinal cord. MVCT studies provide information both for setup correction and plan adaptation. Improved healthy tissue sparing and/or dose escalation can be achieved by adaptive planning.

61 RADIATION PROTECTION AND DOSIMETRY↗

Advances in the implementation of helical tomotherapy-based total marrow irradiation with a novel field junction technique

Given the limitations in the travel ability of the helical tomotherapy (HT) couch, total marrow irradiation (TMI) has to be split in 2 segments, with the lower limbs treated with feet first orientation. The aim of this work is to present a planning technique useful to reduce the dose inhomogeneity resulting from the matching of the 2 helical dose distributions. Three HT plans were generated for each of the 18 patients enrolled. Upper TMI (UTMI) and lower TMI (LTMI) were planned onto the whole-body computed tomography (CT) and on the lower-limb CT, respectively. A twin lower TMI plan (tLTMI) was designed on the whole-body CT. Agreement between LTMI and tLTMI plans was assessed by computing for each dose-volume histogram (DVH) structure the {gamma} index scored with 1% of dose and volume difference thresholds. UTMI and tLTMI plans were summed together on the whole-body CT, enabling the evaluation of dose inhomogeneity. Moreover, a couple of transition volumes were used to improve the dose uniformity in the abutment region. For every DVH, a number of points >99% passed the {gamma} analysis, validating the method used to generate the twin plan. The planned dose inhomogeneity at the junction level resulted within {+-}10% of the prescribed dose. Median dose reduction to organs at risk ranged from 30-80% of the prescribed dose. Mean conformity index was 1.41 (range 1.36-1.44) for the whole-body target. The technique provided a 'full helical' dose distribution for TMI treatments, which can be considered effective only if the dose agreement between LTMI and tLTMI plans is met. The planning of TMI with HT for the whole body with adequate dose homogeneity and conformity was shown to be feasible.

61 RADIATION PROTECTION AND DOSIMETRY↗