Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Germanium”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Direct detection of MeV-scale dark matter utilizing germanium internal amplification for the charge created by the ionization of impurities

Light, MeV-scale dark matter (DM) is an exciting DM candidate that is undetectable by current experiments. A germanium (Ge) detector utilizing internal charge amplification for the charge carriers created by the ionization of impurities is a promising new technology with experimental sensitivity for detecting MeV-scale DM. We analyze the physics mechanisms of the signal formation, charge creation, charge internal amplification, and the projected sensitivity for directly detecting MeV-scale DM particles. We present a design for a novel Ge detector at helium temperature (~4 K) enabling ionization of impurities from DM impacts. With large localized E-fields, the ionized excitations can be accelerated to kinetic energies larger than the Ge bandgap at which point they can create additional electron–hole pairs, producing intrinsic amplification to achieve an ultra-low energy threshold of ~0.1 eV for detecting low-mass DM particles in the MeV scale. Correspondingly, such a Ge detector with 1 kg-year exposure will have high sensitivity to a DM-nucleon cross section of ~5 × 10 -45 cm 2 at a DM mass of ~10 MeV/c 2 and a DM-electron cross section of ~ 5 × 10 -46 cm 2 at a DM mass of 1 MeV/c 2 .

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The impact of the charge barrier height on Germanium (Ge) detectors with amorphous-Ge contacts for light dark matter searches

Germanium (Ge) detectors with ability of measuring a single electron–hole (e–h) pair are needed in searching for light dark matter (LDM) down to the MeV scale. We investigate the feasibility of Ge detectors with amorphous-Ge (a-Ge) contacts to achieve the sensitivity of measuring a single e-h pair, which requires extremely low leakage current. Three Ge detectors with a-Ge contacts are used to study the charge barrier height for blocking electrons and holes. Using the measured bulk leakage current and the Döhler–Brodsky model, we obtain the values for charge barrier height and the density of localized energy states near the Fermi energy level for the top and bottom contacts, respectively. We predict that the bulk leakage current is extremely small and can be neglected at helium temperature ( $$\sim $$ ~ 4 K). Thus, Ge detectors with a-Ge contacts possess the potential to measure a single e–h pair for detecting LDM particles.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Development of planar P-type point contact germanium detectors for low-mass dark matter searches

The detection of low-energy deposition in the range of sub-eV through ionization using germanium (Ge) with a bandgap of ~ 0.7 eV requires internal amplification of the charge signal. This can be achieved through high electric field that accelerates charge carriers, which can then generate more charge carriers. The minimum electric field required to generate internal charge amplification is derived for different temperatures. We report the development of a planar point contact Ge detector in terms of its fabrication and the measurements of its leakage current and capacitance as a function of applied bias voltage. With the determination of the measured depletion voltage, the field distribution is calculated using GeFiCa, which predicts that the required electric field for internal charge amplification can be achieved in proximity to the point contact. The energy response to an Am-241 source is characterized and discussed. We conclude that such a detector with internal charge amplification can be used to search for low-mass dark matter.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Observation of time-dependent internal charge amplification in a planar germanium detector at cryogenic temperature

For the first time, time-dependent internal charge amplification through impact ionization has been observed in a planar germanium (Ge) detector operated at cryogenic temperature. In a time period of 30 and 45 min after applying a bias voltage, the charge energy corresponding to a baseline of the 59.54 keVγ rays from a 241 Am source is amplified for a short period of time and then decreases back to the baseline. The amplification of charge energy depends strongly on the applied positive bias voltage with drifting holes across the detector. No such phenomenon is visible with drifting electrons across the detector. We find that the observed charge amplification is dictated by the impact ionization of charged states, which has a strong correlation with impurity level and applied electric field. We analyze the dominant physics mechanisms that are responsible for the creation and the impact ionization of charged states. Our analysis suggests that the appropriate level of impurity in a Ge detector can enhance charge yield through the impact ionization of charged states to achieve extremely low-energy detection threshold (< 10 meV) for MeV-scale dark matter searches if the charge amplification can be stabilized.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

2025 Annual INMM Graph and Tables for High Purity Germanium Detector Normalization Presentation

The data set includes gamma spectroscopy peak data for measurements taken with two different high purity germanium detectors using a mixed nuclide source and a U-235 fuel rod. There are a total of 5 specific energy peaks that were analyzed for the mixed nuclide source stemming from Am-241, Cd-109, Cs-137, and Co-60. There are a total of 3 specific energy peaks that were analyzed for the U-235 fuel rod. The data set includes the calculations and results from using a linear correction factor, absolute efficiency curve, and relative efficiency curve to compare the net peaks counts from two different detectors.

Drumm, Natalie Daphne [Sandia National Laboratorie↗

Retrieval of the complex-valued refractive index of germanium near the M 4,5 absorption edge

The complex-valued index of refraction of germanium in the extreme ultraviolet (XUV) is measured by multiangle reflectance of synchrotron radiation. The resulting index of refraction is higher resolution than previously measured values. It reveals new structures attributed to transitions from the 3d-core orbitals to the $Σ^{c}_{5,2}$ and the $X^{c}_{5,2}$ conduction bands. Additionally, it is shown that the problem of total external reflection, which renders multi-angle reflectance measurements insensitive to the complex-valued refractive index at grazing incidence, can be overcome by employing measurements at angles of incidence away from the critical angle.

36 MATERIALS SCIENCE↗

A Germanium Detector with Optimized Compton Veto for High Sensitivity at Low Energy

We have built a prototype germanium detector with a Compton veto that is optimized for high sensitivity in the low-energy range around ~100 keV. It is specifically designed to address the problem to directly detect plutonium gamma emissions in spent nuclear fuel by non-destructive assay. This is not possible with current detectors due to the large low-energy background of Compton-scattered high-energy radiation from the fission products, whose gamma flux is at least 6 to 7 orders of magnitude higher than the Pu signal. Our instrument is designed to assess the feasibility to selectively suppress the background in the low-energy region around ~100 keV with the strongest Pu X-ray and gamma emissions lines. It employs a thin Ge detector with a large Compton veto directly behind it to suppress the background from forward-scattered radiation by anti-coincidence vetoing. This report summarizes the design considerations and the performance of the instrument.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Nanorods of Silicon and Germanium with Well-Defined Shapes and Sizes

We have made number of important discoveries along the major goals of the project, namely i) electrodeposition of germanium thin films from clusters, ii) synthesis of cluster-based surfactants with long hydrocarbon chains and micelles made of them, iii) grafting of Ge 9 -clusters onto self assembled films of siloxanes attached to glass substrates, iv) doping of Ge 9 -clusters, and v) expanding the clusters to ten-atom cages of Ge 10 2- .

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Large Cryogenic Germanium Detector (Final Report)

The goal of this project was to investigate possible ways of increasing the size of cryogenic Ge detectors. This project identified two possible approaches to increasing the individual cryogenic Ge detector size. The first approach relies on using the existing technology for growing detector-grade (high-purity) germanium crystals of dislocation density 100-7000 cm -2 . The second approach is to consider dislocation-free Ge crystals.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance of the Ultra-High Rate Germanium (UHRGe) System

This report describes the final performance achieved with the detector system developed for the Ultra High Rate Germanium (UHRGe) project. The system performance has been evaluated at low, moderate and high rates and includes the performance of real-time analysis algorithms running in the FPGA of the data acquisition system. This performance is compared to that of offline analyses of streaming waveform data collected with the same data acquisition system the performance of a commercial Multi-Channel Analyzer designed for high-resolution spectroscopy applications, the Canberra LYNX.

47 OTHER INSTRUMENTATION↗

SPG (Spectroscopic Planar Germanium): Field Tests and Instrument Improvements (Final Report)

The Spectroscopic Planar Germanium (SPG) has been demonstrated at the IAEA Physical Inventory Verification (PIV) in South Korea, as well as at the Joint Fuel Cycle Study at Idaho National Laboratory. These field tests were successful and provided valuable feedback from KINAC, IAEA, and national laboratory staff. This feedback was used to direct efforts to improve the instrument this year.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

CDMS Detector Fabrication Improvements and Low Energy Nuclear Recoil Measurements in Germanium

As the CDMS (Cryogenic Dark Matter Search) experiment is scaled up to tackle new dark matter parameter spaces (lower masses and cross-sections), detector production efficiency and repeatability becomes ever more important. A dedicated facility has been commissioned for SuperCDMS detector fabrication at Texas A&M University (TAMU). The fabrication process has been carefully tuned using this facility and its equipment. Production of successfully tested detectors has been demonstrated. Significant improvements in detector performance have been made using new fabrication methods, equipment, and tuning of process parameters. This work has demonstrated the capability for production of next generation CDMS SNOLAB detectors. Additionally, as the dark matter parameter space is probed further, careful calibrations of detector response to nuclear recoil interactions must be performed in order to extract useful information (in relation to dark matter particle characterzations) from experimental results. A neutron beam of tunable energy is used in conjunction with a commercial radiation detector to characterize ionization energy losses in germanium during nuclear recoil events. Data indicates agreement with values predicted by the Lindhard equation, providing a best-t k-value of 0.146.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Hole Spin Qubits in Germanium

Holes in germanium-rich heterostructures provide a compelling alternative for achieving spin based qubits compared to traditional approaches such as electrons in silicon. In this project, we addressed the question of whether holes in Ge/SiGe quantum wells can be confined into laterally defined quantum dots and made into qubits. Through this effort, we successfully fabricated and operated single-metal-layer quantum dot devices in Ge/SiGe in multiple devices. For single quantum dots, we measured the capacitances of the quantum dot to the surface electrodes and find that they reasonably compare to expected values based on the electrode dimensions, suggested that we have formed a lithographic quantum dot. We also compare the results to detailed self-consistent calculations of the expected potential. Finally, we demonstrate, for the first time, a double quantum dot in the Ge/SiGe material system.

36 MATERIALS SCIENCE↗

The Large Enriched Germanium Experiment for Neutrinoless ββ Decay (LEGEND-1000 Preconceptual Design Report)

We propose the construction of LEGEND-1000, the ton-scale Large Enriched Germanium Experiment for Neutrinoless ββ Decay. This experiment is an international project designed to answer one of the highest priority questions in fundamental physics. It consists of 1000 kg of Ge detectors enriched to more than 90% in the 76 Ge isotope of interest operated in a liquid argon active shield at a deep underground lab. The experiment is designed to achieve a discovery potential that covers the inverted-ordering neutrino mass scale region. The baseline design assumes installation in the SNOLAB cryopit. A similar experimental setup could also be realized at the LNGS alternative site.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Assessment of PHDS Fulcrum40h and Ortec Detective-X High Purity Germanium (HPGe) Detector System Performance

This report provides a summary of measurement results used to compare the performance of the PHDS Fulcrum40h and Ortec Detective-X High Purity Germanium (HPGe) detector systems. Specifically, the measurement data collected was used to assess each detector system for gamma efficiency and resolution, gamma angular response and efficiency for an in-situ surface distribution, neutron efficiency, gamma pulse-pileup response, and gamma to neutron crosstalk.

42 ENGINEERING↗

Reassessment of PHDS Fulcrum40h High Purity Germanium (HPGe) Detector System Performance

This report presents a comprehensive evaluation of the updated PHDS Fulcrum40h High Purity Germanium (HPGe) detector system, benchmarking its performance, usability, and software capabilities against the current National Nuclear Security Administration (NNSA) Nuclear Emergency Support Team (NEST) HPGe Detector System Requirements Document. Systematic measurements were conducted using a single Fulcrum40h detector to assess key parameters including gamma efficiency and resolution, neutron detection efficiency, gamma pulse-pileup response, and gamma-to-neutron crosstalk. The Fulcrum40h system, acquired in August 2022, has undergone recent updates by PHDS to address deficiencies identified following the initial NEST requirements release. The results provide critical insights into the detector’s operational capabilities and compliance with NNSA NEST standards.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗