Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Gas sample analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Viking on Mars - A preliminary survey

Selection of landing site, observations of Martian topography from orbit, a log of entry into the Martian atmosphere and landing operations, and soil experiments executed at the landing site are recounted. Several photographs overviewing Martian terrain from orbit (1600 to 1900 km up) are shown. Soil sampling and analysis experiments and experiments designed to detect biotic activity (pyrolysis, labeled release of 14-carbon-tagged CO2, gas exchange and vapor chromatography, pyrolytic release) are described and some preliminary results reported. Results on surface geology and chemical composition of the Martian atmosphere are cited.

Young, R. S.↗

System Controls and Measures Oxygen Fugacity

System developed at Johnson Space Center controls and measures oxygen fugacity in high-temperature chemical research. A ceramic-electrolyte cell is the sensing element. All hardware needed to control gas flow and temperature and to measure cell electromotive force is included. An analytic balance allows in situ thermogravimetric sample analysis.

Williams, R. J.↗

Organics in water contamination analyzer, phase 1

The requirements which would result in identifying the components of an automatic analytical system for the analysis of specific organic compounds in the space station potable water supply are defined. The gas chromatographic system for such an analysis is limited to commercially available off-the-shelf hardware and includes the sample inlet, an ionization detector, capillary columns as well as computerized compound identification. The sampling system will be a special variation of the purge and trap Tenax mode using six-port valves and a 500 microliter water sample. Capillary columns used for the separating of contaminants will be bonded phase fused silica with a silicone stationary phase. Two detectors can be used: photoionization and far ultraviolet, since they are sensitive and compatible with capillary columns. A computer system evaluation and program with the principle of compound identification based on the retention index is presented.

Source record↗

Qualitative and quantitative reasoning about thermodynamics

One goal of qualitative physics is to capture the tacit knowledge of engineers and scientists. It is shown how Qualitative Process theory can be used to express concepts of engineering thermodynamics. In particular, it is shown how to integrate qualitative and quantitative knowledge to solve textbook problems involving thermodynamic cycles, such as gas turbine plants and steam power plants. These ideas were implemented in a program called SCHISM. Its analysis of a sample textbook problem is described and plans for future work are discussed.

Skorstad, Gordon↗

Integrated Microfluidic Gas Sensors for Water Monitoring

A silicon-based microhotplate tin oxide (SnO2) gas sensor integrated into a polymer-based microfluidic system for monitoring of contaminants in water systems is presented. This device is designed to sample a water source, control the sample vapor pressure within a microchannel using integrated resistive heaters, and direct the vapor past the integrated gas sensor for analysis. The sensor platform takes advantage of novel technology allowing direct integration of discrete silicon chips into a larger polymer microfluidic substrate, including seamless fluidic and electrical interconnects between the substrate and silicon chip.

Zhu, L.↗

Organic and Isotope Measurement Protocols under Development for the 2009 Mars Science Laboratory

The Mars Science Laboratory (MSL) is under development by NASA with several international partners for launch in 2009. MSL is designed to quantitatively explore a local region on Mars as a potential habitat for present or past life (http://mars.jpl.nasa.gov/msl). The goals of MSL are to (1) assess the past or present biological potential of the target environment, (2) to characterize its geology and geochemistry, (3) to study planetary processes that influence habitability, and (4) to characterize the surface radiation. The last substantial search for organic molecules on the surface of Mars was with the Viking Landers in 1976 [Biemann, et al., 19771. In that mission, no organics were detected in near surface fines and presently a more comprehensive search is required to understand the potential of that planet to support life. While the Mars Exploration Rovers are able to identify mineralogical signatures of aqueous alteration, they are not equipped to search for organics. The planned capabilities of the MSL rover payload will enable a search for a wide range of organic molecules in both solid samples of rocks and fines and atmospheric samples. MSL will also provide a determination of definitive mineralogy of the solid samples and precision isotope measurements of several volatile elements. Contact and remote surface and subsurface survey tools will establish context for Analytical Laboratory measurements and will facilitate sample selection. The Sample Analysis at Mars (SAM) suite of MSL addresses several of the mission's core measurement goals. SAM includes a gas chromatograph, a mass spectrometer, and a tunable laser spectrometer. We will describe the range of measurement protocols under development and test for SAM and the relationship of our planned measurements to outstanding issues of martian habitability.

Mahaffy, Paul R.↗

The Nitrate/Perchlorate Ratio on Mars as an Indicator for Habitability

Discovery of indigenous martian nitrogen in Mars surface materials has important implications for habitability and the potential development of a nitrogen cycle at some point in martian history. The Sample Analysis at Mars (SAM) instrument suite on the Mars Science Laboratory (MSL) Curiosity Rover detected evolved nitric oxide (NO) gas during pyrolysis of scooped aeolian sediments and drilled mudstone acquired in Gale Crater. The detection of NO suggests an indigenous source of fixed N, and may indicate a mineralogical sink for atmospheric N2 in the form of nitrate. The ratio of nitrate to oxychlorine species (e.g. perchlorate) may provide insight into the extent of development of a nitrogen cycle on Mars.

Stern, J. C.↗

The Nitrate/Perchlorate Ratio on Mars as an Indicator for Habitability

Discovery of indigenous martian nitrogen in Mars surface materials has important implications for habitability and the potential development of a nitrogen cycle at some point in martian history. The Sample Analysis at Mars (SAM) instrument suite on the Mars Science Laboratory (MSL) Curiosity Rover detected evolved nitric oxide (NO) gas during pyrolysis of scooped aeolian sediments and drilled mudstone acquired in Gale Crater. The detection of NO suggests an indigenous source of fixed N, and may indicate a mineralogical sink for atmospheric N2 in the form of nitrate. The ratio of nitrate to oxychlorine species (e.g. perchlorate) may provide insight into the extent of development of a nitrogen cycle on Mars.

Mars↗

New Instrument Brings Next-generation Molecular Analysis of Mars into Sharp Focus

To address the growing need for in situ molecular analysis of Mars samples at fine spatial scales, NASA is developing the miniature LITMS instrument, which combines a laser and gas chromatograph mass spectrometer with a precision subsampling system. LITMS executes a powerful search for biosignatures and geochemical gradients in a rock sample’s individual layers where such features are most distinct.

William B Brinckerhoff↗

Spacecraft Water Impurity Monitor, a System for Water Quality Analysis on Exploration Missions Beyond Low Earth Orbit

Exploration missions beyond low-earth-orbit (LEO) will require advanced instrumentation to monitor water quality. Traveling beyond LEO means the transfer of water samples to an Earth-based laboratory for detailed analysis is not feasible. Detailed analysis of water composition during exploration is still necessary, because having the capability to determine the specific organic chemical causing a change in total organic carbon (TOC) or the specific metal or ionic species causing a change in conductivity has the potential to inform the crew health and system management decisions. On a new vehicle such as a lunar or Mars surface habitat or a Mars transit vehicle, finding “new” impurities not seen on ISS should be expected. The key is to identify the impurity so the correct action can be taken. On ISS we can measure TOC, conductivity, and other physical properties but do not have the capability for detailed analysis using vehicle instrumentation. This is acceptable because ISS can send samples down to Earth for further analysis and obtain the detailed composition. The Spacecraft Water Impurity Monitor (SWIM) will provide detailed water quality analysis for missions in which sample down mass is not available. SWIM is a system comprising organic and inorganic analysis modules. For organic chemicals, a gas chromatograph mass spectrometer (GCMS) detects and identifies organic impurities. For inorganic species, a capillary electrophoresis capacitively coupled contactless conductivity detection (CE-C4D) system as well as ion specific electrodes detect and identify metal ions and other inorganic salts / acids. The SWIM technology demonstration project has completed a System Requirements Review (SRR) to finalize detection requirements and is currently working to refine vehicle interface requirements for a future technology demonstration. The project also has begun preliminary flight design activities for the core analyzers in the instrument suite.

Water Monitoring↗

Spacecraft Water Impurity Monitor, a System for Water Quality Analysis on Exploration Missions Beyond Low Earth Orbit

Exploration missions beyond low-earth-orbit (LEO) will require advanced instrumentation to monitor water quality. Traveling beyond LEO means the transfer of water samples to an Earth-based laboratory for detailed analysis is not feasible. Detailed analysis of water composition during exploration is still necessary, because having the capability to determine the specific organic chemical causing a change in total organic carbon (TOC) or the specific metal or ionic species causing a change in conductivity has the potential to inform the crew health and system management decisions. On a new vehicle such as a lunar or Mars surface habitat or a Mars transit vehicle, finding “new” impurities not seen on ISS should be expected. The key is to identify the impurity so the correct action can be taken. On ISS we can measure TOC, conductivity, and other physical properties but do not have the capability for detailed analysis using vehicle instrumentation. This is acceptable because ISS can send samples down to Earth for further analysis and obtain the detailed composition. The Spacecraft Water Impurity Monitor (SWIM) will provide detailed water quality analysis for missions in which sample down mass is not available. SWIM is a system comprising organic and inorganic analysis modules. For organic chemicals, a gas chromatograph mass spectrometer (GCMS) detects and identifies organic impurities. For inorganic species, a capillary electrophoresis capacitively coupled contactless conductivity detection (CE-C4D) system as well as ion specific electrodes detect and identify metal ions and other inorganic salts / acids. The SWIM technology demonstration project has completed a System Requirements Review (SRR) to finalize detection requirements and is currently working to refine vehicle interface requirements for a future technology demonstration. The project also has begun preliminary flight design activities for the core analyzers in the instrument suite.

Water Monitoring↗

Exploration of the Habitability of Mars with the SAM Suite Investigation on the 2009 Mars Science Laboratory

The 2009 Mars Science Laboratory (MSL) with a substantially larger payload capability that any other Mars rover, to date, is designed to quantitatively assess a local region on Mars as a potential habitat for present or past life. Its goals are (1) to assess past or present biological potential of a target environment, (2) to characterize geology and geochemistry at the MSL landing site, and (3) to investigate planetary processes that influence habitability. The Sample Analysis at Mars (SAM) Suite, in its final stages of integration and test, enables a sensitive search for organic molecules and chemical and isotopic analysis of martian volatiles. MSL contact and remote surface and subsurface survey Instruments establish context for these measurements and facilitate sample identification and selection. The SAM instruments are a gas chromatograph (GC), a mass spectrometer (MS), and a tunable laser spectrometer (TLS). These together with supporting sample manipulation and gas processing devices are designed to analyze either the atmospheric composition or gases extracted from solid phase samples such as rocks and fines. For example, one of the core SAM experiment sequences heats a small powdered sample of a Mars rock or soil from ambient to -1300 K in a controlled manner while continuously monitoring evolved gases. This is followed by GCMS analysis of released organics. The general chemical survey is complemented by a specific search for molecular classes that may be relevant to life including atmospheric methane and its carbon isotope with the TLS and biomarkers with the GCMS.

Mahaffy, P. R.↗

An In Situ , Automated High-Explosives Aging Method Utilizing Two-Dimensional Gas Chromatography–Mass Spectrometry

Understanding chemical changes that occur in high explosives as they age is of great importance to the safe employment and storage of these compounds. Traditional methods of aging high explosives even under accelerated aging conditions are time intensive with durations on the order of months to years. The nature of traditional aging analyses reduces each sample to a snapshot data point often separated widely in time, requiring many assumptions as to how the degradation products develop. Further complicating matters, several analytical techniques are typically employed for each sample analysis in order to ascertain an entire picture of the decomposition pathways. To address these shortcomings with existing methods, a new method of accelerated aging of high explosives utilizing comprehensive two-dimensional gas chromatography coupled to high-resolution mass spectrometry (GC × GC-HRMS) was developed using 2,4,6,8,10,12-hexanitro-2,4,6,8,10,12-hexaazaisowurtzitane (CL-20) as a model compound for method development. This in situ automated method reduces the time scale of aging to a matter of hours using the inlet of the GC × GC as the aging vessel. GC × GC in combination with HRMS allowed for the collection of both evolved gases and other decomposition products produced during the entire aging process in real time with HRMS providing far greater certainty in identification of explosives aging products. Additionally, this method allowed for a higher throughput of samples with greatly simplified sample preparation. Chemometric analysis of the GC × GC-HRMS data set via the alteration analysis (ALA) enabled discovery of statistically significant chemical changes providing insight into the variation of decomposition pathways with varying aging temperatures.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Astrobiology Sample Analysis Program (ASAP) for Advanced Life Detection Instrumentation Development and Calibration

Scientific ground-truth measurements for near-term Mars missions, such as the 2009 Mars Science Laboratory (MSL) mission, are essential for validating current in situ flight instrumentation and for the development of advanced instrumentation technologies for life-detection missions over the next decade. The NASA Astrobiology Institute (NAI) has recently funded a consortium of researchers called the Astrobiology Sample Analysis Program (ASAP) to analyze an identical set of homogenized martian analog materials in a "round-robin" style using both state-of-the-art laboratory techniques as well as in-situ flight instrumentation including the SAM gas chromatograph mass spectrometer and CHEMIN X-ray diffraction/fluorescence instruments on MSL and the Urey and MOMA organic analyzer instruments under development for the 2013 ExoMars missions. The analog samples studied included an Atacama Desert soil from Chile, the Murchison meteorite, a gypsum sample from the 2007 AMASE Mars analog site, jarosite from Panoche Valley, CA, a hydrothermal sample from Rio Tinto, Spain, and a "blind" sample collected during the 2007 MSL slow-motion field test in New Mexico. Each sample was distributed to the team for analysis to: (1) determine the nature and inventory of organic compounds, (2) measure the bulk carbon and nitrogen isotopic composition, (3) investigate elemental abundances, mineralogy and matrix, and (4) search for biological activity. The experimental results obtained from the ASAP Mars analog research consortium will be used to build a framework for understanding the biogeochemistry of martian analogs, help calibrate current spaceflight instrumentation, and enhance the scientific return from upcoming missions.

Glavin, Daniel↗

Instrumentation for in situ sampling and analysis of compounds of interest to Astrobiology in the lower atmosphere and surface of Titan

Instrumentation for exploration of the solar system will require new enabling technology for in situ sample acquisition and analysis of pre-biotic chemistry in extreme planetary environments, such as that encountered at the surface of Titan. The potential use of balloon aero-rovers for Titan places special emphasis on the importance of miniaturization, low power and low usage of consumables. To help meet this need, we are developing a miniature gas chromatograph coupled with a new Mini-Cell ion mobility spectrometer (GC-IMS), and one of us (PMH) has begun development work on a miniaturized cryogenic inlet system with sampling probes for Titan. This instrumentation, and its approach for meeting measurement needs for the analysis of prebiotic chemistry on Titan, will be discussed.

Holland, Paul M.↗

Heating and Sampling Efficiency Evaluation for the Nephele Venus Cloud Sampling Mission Concept

Nephele [1] is a descent probe concept with a unique combination of entry (3D-CC+HEEET), sampling (flow-through passive impactors), and optics (laser-induced breakdown spectroscopy, or LIBS, and surface-enhanced Raman spectroscopy, or SERS), technologies with two key innovations (Figure 1). The first is the integration of the aerosol sampling inlet into the aeroshell body, allowing the possibility of sampling during passive descent without separation. The second is the use of the aerosol capture surface as an optical analysis substrate, allowing fast-cadence aerosol analysis via a dual optical spectrometer instead of mass spectrometry. Although this concept shares some features with other efforts such as Cupid’s Arrow [1] (single-body sample capture system), DAVINCI [2] and Venera-D [3] (use of an optical spectrometer), Nephele is unique in its physical integration of the sonde body, aerosol and gas sampler, and analysis instrumentation. This innovation is designed to eliminate the need for a controlled descent to achieve a detailed atmospheric aerosol transect, which offers in situ planetary science in a small spacecraft envelope. Aeroshell designs with inlets for free-falling sondes are well-understood, though not yet assessed for aerosol capture efficiency. A HEEET aeroshell with a specialized nose inlet material comprised of Carbon-Carbon is proposed for this mission concept.

Venus↗

SIMS Analysis of d18O and d13C of Carbonate Cements in Shale & Mudstone. Final report

This project has had two primary goals: 1) improving new technology for in situ microanalysis of stable isotope ratios by SIMS (secondary ion mass spectrometry) and 2) evaluating the importance of in situ analysis for studies of carbonate cements within shales of the Bakken Petroleum System. The systematic relations of stable isotope ratios provide an important tool to help resolve critical questions in geology. Stable isotope analysis of carbonate cements in shale constrain many topics of interest to DOE including: CO2 sequestration, climate change, and the genesis and quality of rock reservoirs for petroleum, natural gas, and water. However, this evidence is often preserved as fine-scale zonation, which is homogenized by conventional bulk analysis of powders. Recently, analysis of ultra-small spots in polished samples at the University of Wisconsin WiscSIMS Lab. has documented stable isotope zoning in carbonates and other diagenetic cements at smaller scales than previously possible. We have made detailed studies of oxygen and carbon isotope ratios in diagenetic cements from shales of the Bakken Formation from the Williston basin and elsewhere. The Bakken contains both reservoir and source rocks for petroleum. Hydrofracturing has greatly enhanced production of oil in these tight reservoirs. The sediments contain zoned carbonate cements with growth textures that record multiple events. The growth of carbonate (dolomite) cements has been proposed to control reservoir quality, but previous stable isotope studies of homogenized powders could not resolve individual generations of cement and this proposal remains untested. Our better characterization of the multiple growth zones in these carbonates will aid in understanding the genesis of these tight reservoirs and the production of unconventional oil and gas. This study has also developed SIMS standards for analysis of all compositions of Ca-Mg-Fe carbonate and selected Mn-carbonates and hydromagnesite. We have refined techniques for improved accuracy of SIMS stable isotope analysis, and for sub-1-micron spot sizes. We have established protocols for mapping and correlating sample analyses at micron-scale using QGIS software.

04 OIL SHALES AND TAR SANDS↗