Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Gain”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Experimental study of a modulated beam AlGaAs/GaAs diode amplifier operating in the highly saturated gain regime

The variation in the modulation parameters of an optical signal in a diode power amplifier has been studied experimentally. The experimental data obtained agree well with theory that takes into account nonlinear interaction between fields in the gain medium of a laser through inversion beating. It is shown that the dominant type of output signal modulation is phase modulation, whose depth depends on the amplitude – phase coupling coefficient of the gain medium of the amplifier and the nature of the modulation (the phase relationships between the spectral components) of the output signal. (lasers)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

25 Gb s{sup −1} data transmission using a bismuth-doped fibre amplifier with a gain peak shifted to 1300 nm

Using a bismuth-doped aluminosilicate fibre laser tunable in the range 1130–1210 nm, we have examined the effect of pump wavelength on the gain spectrum of bismuth-doped phosphosilicate fibres in the range 1220–1400 nm. At a pump wavelength of 1195 nm, we obtained a peak gain wavelength of 1300 nm, which is near the centre of the standard range for O-band transmission (1270–1320 nm) in fibre-optic communication links, in particular between data centres. Using a bismuth-doped phosphosilicate fibre amplifier pumped at 1195 nm, we have demonstrated that the transmission distance for a signal from a semiconductor laser diode directly modulated at 25 Gb s{sup −1} [on – off keying (OOK) modulation] can be increased for G.652 fibre from the standard 10 to 80 km or even more. (letters)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

GQ-16, a Novel Peroxisome Proliferator-activated Receptor γ (PPARγ) Ligand, Promotes Insulin Sensitization without Weight Gain

Background: PPARγ agonists improve insulin sensitivity but also evoke weight gain. Results: GQ-16 is a PPARγ partial agonist that blocks receptor phosphorylation by Cdk5 and improves insulin sensitivity in diabetic mice in the absence of weight gain. Conclusion: The unique binding mode of GQ-16 appears to be responsible for the compound’s advantageous pharmacological profile. Significance: Similar compounds could have promise as anti-diabetic therapeutics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Simons Observatory: gain, bandpass and polarization-angle calibration requirements for B-mode searches

We quantify the calibration requirements for systematic uncertainties for next-generation ground-based observatories targeting the large-angle B-mode polarization of the Cosmic Microwave Background, with a focus on the Simons Observatory (SO). We explore uncertainties on gain calibration, bandpass center frequencies, and polarization angles, including the frequency variation of the latter across the bandpass. We find that gain calibration and bandpass center frequencies must be known to percent levels or less to avoid biases on the tensor-to-scalar ratio r on the order of Δ r∼10-3, in line with previous findings. Polarization angles must be calibrated to the level of a few tenths of a degree, while their frequency variation between the edges of the band must be known to O(10) degrees. Given the tightness of these calibration requirements, we explore the level to which residual uncertainties on these systematics would affect the final constraints on r if included in the data model and marginalized over. We find that the additional parameter freedom does not degrade the final constraints on r significantly, broadening the error bar by O(10%) at most. We validate these results by reanalyzing the latest publicly available data from the collaboration within an extended parameter space covering both cosmological, foreground and systematic parameters. Finally, our results are discussed in light of the instrument design and calibration studies carried out within SO.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Pedestal transport in H-mode plasmas for fusion gain

The first high fidelity gyrokinetic simulations of the energy losses in the transport barriers of large tokamaks in pursuit of fusion gain are presented. These simulations calculate the turbulent energy losses with an extensive treatment of relevant physical effects—fully kinetic, non-linear, electromagnetic—inclusive of all major plasma species, and in equilibria with relevant shape and local bootstrap current for fusion-relevant cases. We find that large plasmas with a small normalized gyroradius lie in an unexpected regime of enhanced losses that can prevent the projected energy gain. Our simulations are qualitatively consistent with recent experiments on JET with an ITER-like wall. Interestingly and very importantly, the simulations predict parameter regimes of reduced transport that are quite fusion-favorable.

Kotschenreuther, M.↗

The laser-based gain monitoring system of the calorimeters in the Muon $g-2$ experiment at Fermilab

The Muon $g-2$ experiment, E989, is currently taking data at Fermilab with the aim of reducing the experimental error on the muon anomaly by a factor of four and possibly clarifying the current discrepancy with the theoretical prediction. A central component of this four-fold improvement in precision is the laser calibration system of the calorimeters, which has to monitor the gain variations of the photo-sensors with a 0.04\% precision on the short-term ($\sim 1\,$ms). This is about one order of magnitude better than what has ever been achieved for the calibration of a particle physics calorimeter. The system is designed to monitor also long-term gain variations, mostly due to temperature effects, with a precision below the per mille level. This article reviews the design, the implementation and the performance of the Muon $g-2$ laser calibration system, showing how the experimental requirements have been met.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effective Gain and Ion Back Flow study of triple and quadruple GEM detector

Abstract Gas electron Multipliers (GEM) are a new generation of gaseous avalanche devices in the Micro Pattern Gaseous Detector (MPGD) category. GEMs are widely used in both nuclear and high energy experiments as well as in medical science. Several parameters define the performance of these types of devices under various experimental conditions. This article focuses on the study of effective gain and Ion Back Flow (IBF) in both triple and quadruple GEM detectors. Effective gain and IBF are two of the most important parameters in determining the performance of GEM detectors.

Instruments & Instrumentation↗

Investigation of low gain avalanche detectors exposed to proton fluences beyond 10 15 n eq cm -2

Abstract Low gain avalanche detectors (LGADs) deliver excellent timing resolution, which can mitigate mis-assignment of vertices associated with pileup at the High Luminosity LHC and other future hadron colliders. The most highly irradiated LGADs will be subject to 2.5 × 10 15 n eq cm -2 of hadronic fluence during HL-LHC operation; their performance must tolerate this. Hamamatsu Photonics K.K. and Fondazione Bruno Kessler LGADs have been irradiated with 400 and 500 MeV protons respectively in several steps up to 1.5 × 10 15 n eq cm -2 . Measurements of the acceptor removal constants of the gain layers, evolution of the timing resolution and charge collection with damage, and inter-channel isolation characteristics, for a variety of design options, are presented here.

Instruments & Instrumentation↗

Direct drive with the argon fluoride laser as a path to high fusion gain with sub-megajoule laser energy

Argon fluoride (ArF) is currently the shortest wavelength laser that can credibly scale to the energy and power required for high gain inertial fusion. ArF's deep ultraviolet light and capability to provide much wider bandwidth than other contemporary inertial confinement fusion (ICF) laser drivers would drastically improve the laser target coupling efficiency and enable substantially higher pressures to drive an implosion. Our radiation hydrodynamics simulations indicate gains greater than 100 are feasible with a sub-megajoule ArF driver. Our laser kinetics simulations indicate that the electron beam-pumped ArF laser can have intrinsic efficiencies of more than 16%, versus about 12% for the next most efficient krypton fluoride excimer laser. We expect at least 10% ‘wall plug' efficiency for delivering ArF light to target should be achievable using solid-state pulsed power and efficient electron beam transport to the laser gas that was demonstrated with the U.S. Naval Research Laboratory's Electra facility. These advantages could enable the development of modest size and lower cost fusion power plant modules. This would drastically change the present view on inertial fusion energy as being too expensive and the power plant size too large.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Beyond the gain exponent: Effect of damping, scale length, and speckle length on stimulated scatter

Three-dimensional wave propagation simulations and experiments show that the gain exponent, an often used metric to assess the likelihood of stimulated Brillouin scatter, is insufficient and must be augmented with another parameter, N r , the ratio of the resonance length, L res , to the laser speckle length. Additionally, the damping rate of ion acoustic waves, ν , and thus L res , which is proportional to ν , are easily varied with plasma species composition, e.g., by varying the ratio of hydrogen and carbon ions. As N r decreases, stimulated Brillouin scattering increases despite the same gain exponent.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Energy gain scale calibration of the XRISM Resolve microcalorimeter spectrometer: ground calibration results and on-orbit comparison

The Resolve instrument aboard the X-ray Imaging and Spectroscopy Mission (XRISM) is a 36-pixel microcalorimeter spectrometer that provides nondispersive spectroscopy with ∼ 5 eV spectral resolution in the soft X-ray waveband. Resolve has a requirement to provide an absolute energy-scale calibration of ± 2 eV from 0.3 to 12 keV. We describe our ground calibration strategy and results of a subset of the ground calibration campaigns, including a discussion of improvements in the energy scale ground calibration compared with Hitomi’s. These improvements include calibration of the low-energy band below 4 keV with the instrument in the flight dewar and the dewar aperture door open, which was not performed for Hitomi, and thorough measurements over an extended high-energy waveband to 22 keV. We also developed an improved technique for gain calibration of “mid-res” secondary events, which have suppressed gain due to proximity to a preceding X-ray event (18 to 70 ms) on the same pixel. We provide a discussion of the on-orbit energy scale monitoring campaigns and an assessment of the Resolve energy scale uncertainties, a key parameter for astrophysics analysis. Energy-scale calibration approaches for future space-based instruments, including the X-ray Integral Field Unit on Athena and microcalorimeter spectrometers proposed or under discussion for future X-ray observatory concepts, have heritage in the calibration of XRISM. We briefly comment on lessons learned from Resolve calibration that are relevant for these future instruments.

Aluminum↗

Compression and smart coding of offset and gain maps for intraoral digital x-ray sensors

The response of indirect x-ray digital imaging sensors is often not homogenous on the entire surface area. In this case, calibration is needed to build offset and gain maps, which are used to correct the sensor output. The sensors of new generation are equipped with an on-board memory, which serves to store these maps. However, because of its limited dimension, the maps have to be compressed before saving them. This step is critical because of the extremely high compression rate required. The authors propose here a novel method to achieve such a high compression rate, without degrading the quality of the sensor output. It is based on quad tree decomposition, which performs an adaptive sampling of the offset and gain maps, matched with a RBF-based interpolation strategy. The method was tested on a typical intraoral radiographic sensor and compared with traditional compression techniques. Qualitative and quantitative results show that the method achieves a higher compression rate and produces images of superior quality. The method can be adopted also in different fields where a high compression rate is required.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Monte Carlo calculation of the maximum therapeutic gain of tumor antivascular alpha therapy

Purpose: Metastatic melanoma lesions experienced marked regression after systemic targeted alpha therapy in a phase 1 clinical trial. This unexpected response was ascribed to tumor antivascular alpha therapy (TAVAT), in which effective tumor regression is achieved by killing endothelial cells (ECs) in tumor capillaries and, thus, depriving cancer cells of nutrition and oxygen. The purpose of this paper is to quantitatively analyze the therapeutic efficacy and safety of TAVAT by building up the testing Monte Carlo microdosimetric models. Methods: Geant4 was adapted to simulate the spatial nonuniform distribution of the alpha emitter {sup 213}Bi. The intraluminal model was designed to simulate the background dose to normal tissue capillary ECs from the nontargeted activity in the blood. The perivascular model calculates the EC dose from the activity bound to the perivascular cancer cells. The key parameters are the probability of an alpha particle traversing an EC nucleus, the energy deposition, the lineal energy transfer, and the specific energy. These results were then applied to interpret the clinical trial. Cell survival rate and therapeutic gain were determined. Results: The specific energy for an alpha particle hitting an EC nucleus in the intraluminal and perivascular models is 0.35 and 0.37 Gy, respectively. As the average probability of traversal in these models is 2.7% and 1.1%, the mean specific energy per decay drops to 1.0 cGy and 0.4 cGy, which demonstrates that the source distribution has a significant impact on the dose. Using the melanoma clinical trial activity of 25 mCi, the dose to tumor EC nucleus is found to be 3.2 Gy and to a normal capillary EC nucleus to be 1.8 cGy. These data give a maximum therapeutic gain of about 180 and validate the TAVAT concept. Conclusions: TAVAT can deliver a cytotoxic dose to tumor capillaries without being toxic to normal tissue capillaries.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-I-11: Cascaded Linear System Model for Columnar CsI Flat Panel Imagers with Depth Dependent Gain and Blur

Purpose: To implement a depth dependent gain and blur cascaded linear system model (CLSM) for optimizing columnar structured CsI indirect conversion flat panel imager (FPI) for advanced imaging applications. Methods: For experimental validation, depth dependent escape efficiency, e(z), was extracted from PHS measurement of different CsI scintillators (thickness, substrate and light output). The inherent MTF and DQE of CsI was measured using high resolution CMOS sensor. For CLSM, e(z) and the depth dependent MTF(f,z), were estimated using Monte Carlo simulation (Geant4) of optical photon transport through columnar CsI. Previous work showed that Monte Carlo simulation for CsI was hindered by the non-ideality of its columnar structure. In the present work we allowed variation in columnar width with depth, and assumed diffusive reflective backing and columns. Monte Carlo simulation was performed using an optical point source placed at different depth of the CsI layer, from which MTF(z,f) and e(z) were computed. The resulting e(z) with excellent matching with experimental measurements were then applied to the CLSM, Monte Carlo simulation was repeated until the modeled MTF, DQE(f) also match experimental measurement. Results: For a 150 micron FOS HL type CsI, e(z) varies between 0.56 to 0.45, and the MTF at 14 cycles/mm varies between 62.1% to 3.9%, from the front to the back of the scintillator. The overall MTF and DQE(f) at all frequencies are in excellent agreement with experimental measurements at all frequencies. Conclusion: We have developed a CLSM for columnar CsI scintillators with depth dependent gain and MTF, which were estimated from Monte Carlo simulation with novel optical simulation settings. Preliminary results showed excellent agreement between simulation results and experimental measurements. Future work is aimed at extending this approach to optimize CsI screen optic design and sensor structure for achieving higher DQE(f) in cone-beam CT, which uses high kVp.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Repeated gain and loss of a single gene modulates the evolution of vascular plant pathogen lifestyles

Vascular plant pathogens travel long distances through host veins, leading to life-threatening, systemic infections. In contrast, nonvascular pathogens remain restricted to infection sites, triggering localized symptom development. The contrasting features of vascular and nonvascular diseases suggest distinct etiologies, but the basis for each remains unclear. Here, we show that the hydrolase CbsA acts as a phenotypic switch between vascular and nonvascular plant pathogenesis. cbsA was enriched in genomes of vascular phytopathogenic bacteria in the family Xanthomonadaceae and absent in most nonvascular species. CbsA expression allowed nonvascular Xanthomonas to cause vascular blight, while cbsA mutagenesis resulted in reduction of vascular or enhanced nonvascular symptom development. Phylogenetic hypothesis testing further revealed that cbsA was lost in multiple nonvascular lineages and more recently gained by some vascular subgroups, suggesting that vascular pathogenesis is ancestral. Our results overall demonstrate how the gain and loss of single loci can facilitate the evolution of complex ecological traits.

59 BASIC BIOLOGICAL SCIENCES↗

Calibration of cathode strip gains in multiwire drift chambers of the GlueX experiment

A technique for calibrating cathode strip gains in multiwire drift chambers of the GlueX experiment is described. The accuracy of the technique is estimated based on Monte Carlo generated data with known gain coefficients in the strip signal channels. One of the four detector sections has been calibrated using cosmic rays. Results of drift chamber calibration on the accelerator beam upon inclusion in the GlueX experimental setup are presented.

Berdnikov, V. V.↗

Optical Gain in Heavily Doped Al{sub x}Ga{sub 1 –x}N:Si Structures

Gain characteristics of heavily doped Al{sub x}Ga{sub 1 –x}N/AlN:Si structures with c x = 0.65 and 0.74 have been studied under pulsed optical pumping by Nd:YAG laser radiation at wavelength λ = 266 nm. The absolute values of the optical gain measured at spectral maximum of the room-temperature luminescence spectrum reach (0.5–6) × 10{sup 3} сm{sup –1} at an pumping power density of 8–600 kW/cm{sup 2}. Cross sections of the radiative and donor–acceptor recombination are close to each other and exceed 10{sup 16} cm{sup 2}.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Parathyroid hormone (PTH)–induced bone gain is blunted in SOST overexpressing and deficient mice

Intermittent parathyroid hormone (PTH) treatment is a potent bone anabolic principle that suppresses expression of the bone formation inhibitor Sost. We addressed the relevance of Sost suppression for PTH-induced bone anabolism in vivo using mice with altered Sost gene dosage. Six-month-old Sost overexpressing and 2-month-old Sost deficient male mice and their wild-type littermates were subjected to daily injections of 100 mg/kg PTH(1–34) or vehicle for a 2-month period. A follow-up study was performed in Sost deficient mice using 40 and 80 mg/kg PTH(1–34). Animals were sacrificed 4 hours after the final PTH administration and Sost expression in long bone diaphyses was determined by qPCR. Bone changes were analyzed in vivo in the distal femur metaphysis by pQCT and ex vivo in the tibia and lumbar spine by DXA. Detailed ex vivo analyses of the femur were performed by pQCT, mCT, and histomorphometry. Overexpression of Sost resulted in osteopenia and Sost deletion in high bone mass. As shown before, PTH suppressed Sost in wild-type mice. PTH treatment induced substantial increases in bone mineral density, content, and cortical thickness and in aging wild-type mice also led to cancellous bone gain owing to amplified bone formation rates. PTH-induced bone gain was blunted at all doses and skeletal sites in Sost overexpressing and deficient mice owing to attenuated bone formation rates, whereas bone resorption was not different from that in PTH-treated wild-type controls. These data suggest that suppression of the bone formation inhibitor Sost by intermittent PTH treatment contributes to PTH bone anabolism.

59 BASIC BIOLOGICAL SCIENCES↗