Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “GRAPHICAL USER INTERFACE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Turbofan Engine Simulated in a Graphical Simulation Environment

Recently, there has been an increase in the development of intelligent engine technology with advanced active component control. The computer engine models used in these control studies are component-level models (CLM), models that link individual component models of state space and nonlinear algebraic equations, written in a computer language such as Fortran. The difficulty faced in performing control studies on Fortran-based models is that Fortran is not supported with control design and analysis tools, so there is no means for implementing real-time control. It is desirable to have a simulation environment that is straightforward, has modular graphical components, and allows easy access to health, control, and engine parameters through a graphical user interface. Such a tool should also provide the ability to convert a control design into real-time code, helping to make it an extremely powerful tool in control and diagnostic system development. Simulation time management is shown: Mach number versus time, power level angle versus time, altitude versus time, ambient temperature change versus time, afterburner fuel flow versus time, controller and actuator dynamics, collect initial conditions, CAD output, and component-level model: CLM sensor, CAD input, and model output. The Controls and Dynamics Technologies Branch at the NASA Glenn Research Center has developed and demonstrated a flexible, generic turbofan engine simulation platform that can meet these objectives, known as the Modular Aero-Propulsion System Simulation (MAPSS). MAPSS is a Simulink-based implementation of a Fortran-based, modern high pressure ratio, dual-spool, low-bypass, military-type variable-cycle engine with a digital controller. Simulink (The Mathworks, Natick, MA) is a computer-aided control design and simulation package allows the graphical representation of dynamic systems in a block diagram form. MAPSS is a nonlinear, non-real-time system composed of controller and actuator dynamics (CAD) and component-level model (CLM) modules. The controller in the CAD module emulates the functionality of a digital controller, which has a typical update rate of 50 Hz. The CLM module simulates the dynamics of the engine components and uses an update rate of 2500 Hz, which is needed to iterate to balance mass and energy among system components. The actuators in the CAD module use the same sampling rate as those in the CLM. Two graphs of normalized spool speed versus time in seconds and one graph of normalized average metal temperature versus time in seconds is shown. MAPSS was validated via open-loop and closed-loop comparisons with the Fortran simulation. The preceding plots show the normalized results of a closed-loop comparison looking at three states of the model: low-pressure spool speed, high-pressure spool speed, and the average metal temperature measured from the combustor to the high-pressure turbine. In steady state, the error between the simulations is less than 1 percent. During a transient, the difference between the simulations is due to a correction in MAPSS that prevents the gas flow in the bypass duct inlet from flowing forward instead of toward the aft end, which occurs in the Fortran simulation. A comparison between MAPSS and the Fortran model of the bypass duct inlet flow for power lever angles greater than 35 degrees is shown.

Parker, Khary I.↗

Software and Algorithms for Biomedical Image Data Processing and Visualization

A new software equipped with novel image processing algorithms and graphical-user-interface (GUI) tools has been designed for automated analysis and processing of large amounts of biomedical image data. The software, called PlaqTrak, has been specifically used for analysis of plaque on teeth of patients. New algorithms have been developed and implemented to segment teeth of interest from surrounding gum, and a real-time image-based morphing procedure is used to automatically overlay a grid onto each segmented tooth. Pattern recognition methods are used to classify plaque from surrounding gum and enamel, while ignoring glare effects due to the reflection of camera light and ambient light from enamel regions. The PlaqTrak system integrates these components into a single software suite with an easy-to-use GUI (see Figure 1) that allows users to do an end-to-end run of a patient s record, including tooth segmentation of all teeth, grid morphing of each segmented tooth, and plaque classification of each tooth image. The automated and accurate processing of the captured images to segment each tooth [see Figure 2(a)] and then detect plaque on a tooth-by-tooth basis is a critical component of the PlaqTrak system to do clinical trials and analysis with minimal human intervention. These features offer distinct advantages over other competing systems that analyze groups of teeth or synthetic teeth. PlaqTrak divides each segmented tooth into eight regions using an advanced graphics morphing procedure [see results on a chipped tooth in Figure 2(b)], and a pattern recognition classifier is then used to locate plaque [red regions in Figure 2(d)] and enamel regions. The morphing allows analysis within regions of teeth, thereby facilitating detailed statistical analysis such as the amount of plaque present on the biting surfaces on teeth. This software system is applicable to a host of biomedical applications, such as cell analysis and life detection, or robotic applications, such as product inspection or assembly of parts in space and industry.

Talukder, Ashit↗

IJS procedure for RELAP5 to TRACE input model conversion using SNAP

The TRAC/RELAP Advanced Computational Engine (TRACE) advanced, best-estimate reactor systems code developed by the U.S. Nuclear Regulatory Commission comes with a graphical user interface called Symbolic Nuclear Analysis Package (SNAP). Much of efforts have been done in the past to develop the RELAP5 input decks. The purpose of this study is to demonstrate the Institut 'Josef Stefan' (IJS) conversion procedure from RELAP5 to TRACE input model of BETHSY facility. The IJS conversion procedure consists of eleven steps and is based on the use of SNAP. For calculations of the selected BETHSY 6.2TC test the RELAP5/MOD3.3 Patch 4 and TRACE V5.0 Patch 1 were used. The selected BETHSY 6.2TC test was 15.24 cm equivalent diameter horizontal cold leg break in the reference pressurized water reactor without high pressure and low pressure safety injection. The application of the IJS procedure for conversion of BETHSY input model showed that it is important to perform the steps in proper sequence. The overall calculated results obtained with TRACE using the converted RELAP5 model were close to experimental data and comparable to RELAP5/MOD3.3 calculations. Therefore it can be concluded, that proposed IJS conversion procedure was successfully demonstrated on the BETHSY integral test facility input model. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Software Simulates Sight: Flat Panel Mura Detection

In the increasingly sophisticated world of high-definition flat screen monitors and television screens, image clarity and the elimination of distortion are paramount concerns. As the devices that reproduce images become more and more sophisticated, so do the technologies that verify their accuracy. By simulating the manner in which a human eye perceives and interprets a visual stimulus, NASA scientists have found ways to automatically and accurately test new monitors and displays. The Spatial Standard Observer (SSO) software metric, developed by Dr. Andrew B. Watson at Ames Research Center, measures visibility and defects in screens, displays, and interfaces. In the design of such a software tool, a central challenge is determining which aspects of visual function to include while accuracy and generality are important, relative simplicity of the software module is also a key virtue. Based on data collected in ModelFest, a large cooperative multi-lab project hosted by the Optical Society of America, the SSO simulates a simplified model of human spatial vision, operating on a pair of images that are viewed at a specific viewing distance with pixels having a known relation to luminance. The SSO measures the visibility of foveal spatial patterns, or the discriminability of two patterns, by incorporating only a few essential components of vision. These components include local contrast transformation, a contrast sensitivity function, local masking, and local pooling. By this construction, the SSO provides output in units of "just noticeable differences" (JND) a unit of measure based on the assumed smallest difference of sensory input detectable by a human being. Herein is the truly amazing ability of the SSO, while conventional methods can manipulate images, the SSO models human perception. This set of equations actually defines a mathematical way of working with an image that accurately reflects the way in which the human eye and mind behold a stimulus. The SSO is intended for a wide variety of applications, such as evaluating vision from unmanned aerial vehicles, measuring visibility of damage to aircraft and to the space shuttles, predicting outcomes of corrective laser eye surgery, inspecting displays during the manufacturing process, estimating the quality of compressed digital video, evaluating legibility of text, and predicting discriminability of icons or symbols in a graphical user interface.

Source record↗

STOCK: Structure mapper and online coarse-graining kit for molecular simulations

We present a web toolkit STructure mapper and Online Coarse-graining Kit for setting up coarse-grained molecular simulations. The kit consists of two tools: structure mapping and Boltzmann inversion tools. The aim of the first tool is to define a molecular mapping from high, e.g. all-atom, to low, i.e. coarse-grained, resolution. Using a graphical user interface it generates input files, which are compatible with standard coarse-graining packages, e.g. VOTCA and DL_CGMAP. Our second tool generates effective potentials for coarse-grained simulations preserving the structural properties, e.g. radial distribution functions, of the underlying higher resolution model. The required distribution functions can be provided by any simulation package. Simulations are performed on a local machine and only the distributions are uploaded to the server. The applicability of the toolkit is validated by mapping atomistic pentane and polyalanine molecules to a coarse-grained representation. Effective potentials are derived for systems of TIP3P (transferable intermolecular potential 3 point) water molecules and salt solution. The presented coarse-graining web toolkit is available at http://stock.cmm.ki.si.

74 ATOMIC AND MOLECULAR PHYSICS↗

TopoMS: Comprehensive topological exploration for molecular and condensed-matter systems

We introduce TopoMS, a computational tool enabling detailed topological analysis of molecular and condensed-matter systems, including the computation of atomic volumes and charges through the quantum theory of atoms in molecules, as well as the complete molecular graph. With roots in techniques from computational topology, and using a shared-memory parallel approach, TopoMS provides scalable, numerically robust, and topologically consistent analysis. TopoMS can be used as a command-line tool or with a GUI (graphical user interface), where the latter also enables an interactive exploration of the molecular graph. This paper presents algorithmic details of TopoMS and compares it with state-of-the-art tools: Bader charge analysis v1.0 (Arnaldsson et al., 01/11/17) and molecular graph extraction using Critic2 (Otero-de-la-Roza et al., Comput. Phys. Commun. 2014, 185, 1007). TopoMS not only combines the functionality of these individual codes but also demonstrates up to 4× performance gain on a standard laptop, faster convergence to fine-grid solution, robustness against lattice bias, and topological consistency. TopoMS is released publicly under BSD License.

97 MATHEMATICS AND COMPUTING↗

Morpheus Spectral Counter: A computational tool for label-free quantitative mass spectrometry using the Morpheus search engine

Label-free quantitative MS based on the Normalized Spectral Abundance Factor (NSAF) has emerged as a straightforward and robust method to determine the relative abundance of individual proteins within complex mixtures. Here, we present Morpheus Spectral Counter (MSpC) as the first computational tool that directly calculates NSAF values from output obtained from Morpheus, a fast, open-source, peptide-MS/MS matching engine compatible with high-resolution accurate-mass instruments. NSAF has distinct advantages over other MS-based quantification methods, including a higher dynamic range as compared to isobaric tags, no requirement to align and re-extract MS1 peaks, and increased speed. MSpC features an easy to use graphic user interface that additionally calculates both distributed and unique NSAF values to permit analyses of both protein families and isoforms/proteoforms. MSpC determinations of protein concentration were linear over several orders of magnitude based on the analysis of several high-mass accuracy datasets either obtained from PRIDE or generated with total cell extracts spiked with purified Arabidopsis 20S proteasomes. Lastly, the MSpC software was developed in C# and is open sourced under a permissive license with the code made available at http://dcgemperline.github.io/Morpheus_SpC/.

59 BASIC BIOLOGICAL SCIENCES↗

Turbomole

Turbomole is a highly optimized software package for large‐scale quantum chemical simulations of molecules, clusters, and periodic solids. Turbomole uses G aussian basis sets and specializes on predictive electronic structure methods with excellent cost to performance characteristics, such as (time‐dependent) density functional theory ( TDDFT ), second‐order M øller– P lesset theory, and explicitly correlated coupled cluster ( CC ) methods. These methods are combined with ultraefficient and numerically stable algorithms such as integral‐direct and Laplace transform methods, resolution‐of‐the‐identity, pair natural orbitals, fast multipole, and low‐order scaling techniques. Apart from energies and structures, a variety of optical, electric, and magnetic properties are accessible from analytical energy derivatives for electronic ground and excited states. Recent additions include post‐ K ohn– S ham calculations within the random phase approximation, periodic calculations, spin–orbit couplings, explicitly correlated CC singles doubles and perturbative triples methods, CC singles doubles excitation energies, and nonadiabatic molecular dynamics simulations using TDDFT . A dedicated graphical user interface and a user support network are also available. This article is categorized under: Software > Quantum Chemistry

Furche, Filipp↗

SDAT implementation for the analysis of radioxenon β–γ coincidence spectra

The Standard Deconvolution Analysis Tool (SDAT) was developed for analysis of radioxenon β-γ coincidence spectra measured as part of the International Monitoring System (IMS) as defined in the Comprehensive Nuclear-Test-Ban Treaty (CTBT). The SDAT software analyzes each β-γ coincidence spectrum by fitting library vectors of each radionuclide of interest: 131mXe, 133mXe, 133Xe, and 135Xe. Detector background and radon are incorporated as optional components of the sample solution. Results are reported in mBq m-3. A new graphical user interface has been developed to facilitate ease of use and improve the data visualization. Automated energy vs. channel calibration algorithms were developed and implemented based on 137Cs β-γ coincidence spectra. Details on the user tool and testing are included.

Biegalski, S.↗

Acquisition of Real-Time Operation Analytics for an Automated Serial Sectioning System

Mechanical serial sectioning is a highly repetitive technique employed in metallography for the rendering of 3D reconstructions of microstructure. While alternate techniques such as ultrasonic detection, micro-computed tomography, and focused ion beam milling have progressed much in recent years, few alternatives provide equivalent opportunities for comparatively high resolutions over significantly sized cross-sectional areas and volumes. To that end, the introduction of automated serial sectioning systems has greatly heightened repeatability and increased data collection rates while diminishing opportunity for mishandling and other user-introduced errors. Unfortunately, even among current, state-of-the-art automated serial sectioning systems, challenges in data collection have not been fully eradicated. Therefore, this paper highlights two specific advances to assist in this area; a non-contact laser triangulation method for assessment of material removal rates and a newly developed graphical user interface providing real-time monitoring of experimental progress. Furthermore, both are shown to be helpful in the rapid identification of anomalies and interruptions, while also providing comparable and less error-prone measures of removal rate over the course of these long-term, challenging, and innately destructive characterization experiments.

36 MATERIALS SCIENCE↗

Monte Carlo capabilities of the SCALE code system

SCALE is a broadly used suite of tools for nuclear systems modeling and simulation that provides comprehensive, verified and validated, user-friendly capabilities for criticality safety, reactor physics, radiation shielding, and sensitivity and uncertainty analysis. For more than 30 years, regulators, licensees, and research institutions around the world have used SCALE for nuclear safety analysis and design. SCALE provides a “plug-and-play” framework that includes three deterministic and three Monte Carlo radiation transport solvers that can be selected based on the desired solution, including hybrid deterministic/Monte Carlo simulations. SCALE includes the latest nuclear data libraries for continuous-energy and multigroup radiation transport as well as activation, depletion, and decay calculations. SCALE’s graphical user interfaces assist with accurate system modeling, visualization, and convenient access to desired results. SCALE 6.2 will provide several new capabilities and significant improvements in many existing features, especially with expanded continuous-energy Monte Carlo capabilities for criticality safety, shielding, depletion, and sensitivity and uncertainty analysis. Finally, an overview of the Monte Carlo capabilities of SCALE is provided here, with emphasis on new features for SCALE 6.2.

97 MATHEMATICS AND COMPUTING↗

Logical design of anti-prion agents using NAGARA

To accelerate the logical drug design procedure, we created the program “NAGARA,” a plugin for PyMOL, and applied it to the discovery of small compounds called medical chaperones (MCs) that stabilize the cellular form of a prion protein (PrP{sup C}). In NAGARA, we constructed a single platform to unify the docking simulation (DS), free energy calculation by molecular dynamics (MD) simulation, and interfragment interaction energy (IFIE) calculation by quantum chemistry (QC) calculation. NAGARA also enables large-scale parallel computing via a convenient graphical user interface. Here, we demonstrated its performance and its broad applicability from drug discovery to lead optimization with full compatibility with various experimental methods including Western blotting (WB) analysis, surface plasmon resonance (SPR), and nuclear magnetic resonance (NMR) measurements. Combining DS and WB, we discovered anti-prion activities for two compounds and tegobuvir (TGV), a non-nucleoside non-structural protein NS5B polymerase inhibitor showing activity against hepatitis C virus genotype 1. Binding profiles predicted by MD and QC are consistent with those obtained by SPR and NMR. Free energy analyses showed that these compounds stabilize the PrP{sup C} conformation by decreasing the conformational fluctuation of the PrP{sup C}. Because TGV has been already approved as a medicine, its extension to prion diseases is straightforward. Finally, we evaluated the affinities of the fragmented regions of TGV using QC and found a clue for its further optimization. By repeating WB, MD, and QC recursively, we were able to obtain the optimum lead structure. - Highlights: • NAGARA integrates docking simulation, molecular dynamics, and quantum chemistry. • We found many compounds, e.g., tegobuvir (TGV), that exhibit anti-prion activities. • We obtained insights into the action mechanism of TGV as a medical chaperone. • Using QC, we obtained useful information for optimization of the lead compound, TGV. • NAGARA is a convenient platform for drug discovery and lead optimization.

60 APPLIED LIFE SCIENCES↗

AIMSim : An accessible cheminformatics platform for similarity operations on chemicals datasets

The recent advances in deep learning, generative modeling, and statistical learning have ushered in a renewed interest in traditional cheminformatics tools and methods. Quantifying molecular similarity is essential in molecular generative modeling, exploratory molecular synthesis campaigns, and drug-discovery applications to assess how new molecules differ from existing ones. Further, most tools target advanced users and lack general implementations accessible to the larger community. In this work, we introduce Artificial Intelligence Molecular Similarity (AIMSim), an accessible cheminformatics platform for performing similarity operations on collections of molecules called molecular datasets. AIMSim provides a unified platform to perform similarity-based tasks on molecular datasets, such as diversity quantification, outlier and novelty analysis, clustering, dimensionality reduction, and inter-molecular comparisons. AIMSim implements all major binary similarity metrics and molecular fingerprints and is provided as a Python package that includes support for command-line use as well as a Graphical User Interface for code-free utilization with fully interactive plots.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

INSPIRED: Inelastic neutron scattering prediction for instantaneous results and experimental design

Inelastic neutron scattering (INS) has unique advantages in probing how atoms vibrate and how the vibrations propagate and interact. Such dynamic information is crucial in understanding various material properties, from heat capacity, thermal conductivity, phase transitions, and chemical reactions to more exotic quantum behavior. The analysis and interpretation of the INS spectra often start from a model structure of the sample, followed by a series of calculations to obtain the simulated spectra to compare with experiments. The conventional way to perform such calculations usually requires significant time, computing resources, and specialized expertise. Here, we present a new program named INSPIRED (Inelastic Neutron Scattering Prediction for Instantaneous Results and Experimental Design), which enables users to perform rapid INS simulations in several different ways on their personal computers in just a few clicks, with the crystal structure as the only input file. Specifically, the users can choose a pre-trained symmetry-aware neural network (coupled with an autoencoder) to predict the phonon density of states (DOS), 1D S(E) and 2D S(|Q|,E) spectra for any given structure. One can also choose an existing density functional theory (DFT) calculation from a database (containing over 12,000 crystals), and quickly obtain the simulated INS spectra for single crystals and powders. It is also possible to use pre-trained universal machine learning force fields to relax a given crystal structure, calculate the phonon dispersion and DOS, and, subsequently, the INS spectra. All these functions are implemented with a PyQt graphic user interface. Finally, we expect these new tools will benefit broad user communities and significantly improve the efficiency of experiment design, execution, and data analysis for INS.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Scientific Data Processing Framework for Time Series NetCDF Data

ARM Data Integrator (ADI) is a framework to streamline the development of scientific algorithms that analyze time-series NetCDF data, and to improve the content and consistency of the output data products produced by these algorithms. ADI achieves these goals by automating the process of retrieving and preparing data for analysis, supporting the definition of output data products through a graphical interface, and providing a modular, flexible software development architecture. The input data, preprocessing, and output data specifications are defined through a graphical interface and stored in a database. ADI also includes a workflow for data integration, a library of software modules to support the workflow, and a source code generator that produces C, IDL and Python templates. Data preparation support includes automated retrieval of data from input files, merging the retrieved data into appropriately sized chunks, and transformation of the data onto a common coordinate system grid. Through the graphical interface, users can view the details of both their data products and those in the ARM catalog. The variable and attribute definitions of the existing data products can be used to build new output data products. In addition, the rules that make up the ARM archive’s data standards are laid on top of the view of the new data product providing the user with a visual cue indicating where their output violates an archive standard. The necessary configurations are stored in a database that is accessed by the ADI libraries. This paper discusses the ADI framework, its supporting components, and how ADI can significantly decrease the time and cost of implementing scientific algorithms while improving the ability of scientists to disseminate their results.

Atmospheric Science↗

A Preliminary Study of In-House Monte Carlo Simulations: An Integrated Monte Carlo Verification System

Purpose: To develop an infrastructure for the integrated Monte Carlo verification system (MCVS) to verify the accuracy of conventional dose calculations, which often fail to accurately predict dose distributions, mainly due to inhomogeneities in the patient's anatomy, for example, in lung and bone. Methods and Materials: The MCVS consists of the graphical user interface (GUI) based on a computational environment for radiotherapy research (CERR) with MATLAB language. The MCVS GUI acts as an interface between the MCVS and a commercial treatment planning system to import the treatment plan, create MC input files, and analyze MC output dose files. The MCVS consists of the EGSnrc MC codes, which include EGSnrc/BEAMnrc to simulate the treatment head and EGSnrc/DOSXYZnrc to calculate the dose distributions in the patient/phantom. In order to improve computation time without approximations, an in-house cluster system was constructed. Results: The phase-space data of a 6-MV photon beam from a Varian Clinac unit was developed and used to establish several benchmarks under homogeneous conditions. The MC results agreed with the ionization chamber measurements to within 1%. The MCVS GUI could import and display the radiotherapy treatment plan created by the MC method and various treatment planning systems, such as RTOG and DICOM-RT formats. Dose distributions could be analyzed by using dose profiles and dose volume histograms and compared on the same platform. With the cluster system, calculation time was improved in line with the increase in the number of central processing units (CPUs) at a computation efficiency of more than 98%. Conclusions: Development of the MCVS was successful for performing MC simulations and analyzing dose distributions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

FDG-PET Assessment of the Effect of Head and Neck Radiotherapy on Parotid Gland Glucose Metabolism

Purpose: Functional imaging with [F-18]-fluorodeoxyglucose positron emission tomography (FDG-PET) provides the opportunity to define the physiology of the major salivary glands before and after radiation therapy. The goal of this retrospective study was to identify the radiation dose-response relationship of parotid gland glucose metabolism in patients with head and neck squamous cell carcinoma (HNSCC). Materials and Methods: Forty-nine adults with HNSCC were identified who had curative intent intensity-modulated radiation therapy (IMRT) and FDG-PET imaging before and after treatment. Using a graphical user interface, contours were delineated for the parotid glands on axial CT slices while all authors were blinded to paired PET slices. Average and maximal standard uptake values (SUV) were measured within these anatomic regions. Changes in SUV and volume after radiation therapy were correlated with parotid gland dose-volume histograms from IMRT plans. Results: The average parotid gland volume was 30.7 mL and contracted 3.9 {+-} 1.9% with every increase of 10 Gy in mean dose (p = 0.04). However, within the first 3 months after treatment, there was a uniform reduction of 16.5% {+-} 7.3% regardless of dose. The average SUV{sub mean} of the glands was 1.63 {+-} 0.48 pretreatment and declined by 5.2% {+-} 2.5% for every increase of 10 Gy in mean dose (p = 0.04). The average SUV{sub max} was 4.07 {+-} 2.85 pretreatment and decreased in a sigmoid manner with mean dose. A threshold of 32 Gy for mean dose existed, after which SUV{sub max} declined rapidly. Conclusion: Radiation dose responses of the parotid glands can be measured by integrated CT/FDG-PET scans. Retrospective analysis showed sigmoidal declines in the maximum metabolism but linear declines in the average metabolism of the glands with dose. Future studies should correlate this decline in FDG uptake with saliva production to improve treatment planning.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Online Adaptive Hyperthermia Treatment Planning During Locoregional Heating to Suppress Treatment-Limiting Hot Spots

Background: Adequate tumor temperatures during hyperthermia are essential for good clinical response, but excessive heating of normal tissue should be avoided. This makes locoregional heating using phased array systems technically challenging. Online application of hyperthermia treatment planning could help to improve the heating quality. The aim of this study was to evaluate the clinical benefit of online treatment planning during treatment of pelvic tumors heated with the AMC-8 locoregional hyperthermia system. Methods: For online adaptive hyperthermia treatment planning, a graphical user interface was developed. Electric fields were calculated in a preprocessing step using our in-house–developed finite-difference–based treatment planning system. This allows instant calculation of the temperature distribution for user-selected phase-amplitude settings during treatment and projection onto the patient's computed tomographic scan for online visualization. Online treatment planning was used for 14 treatment sessions in 8 patients to reduce the patients' reports of hot spots while maintaining the same level of tumor heating. The predicted decrease in hot spot temperature should be at least 0.5°C, and the tumor temperature should decrease less than 0.2°C. These predictions were compared with clinical data: patient feedback about the hot spot and temperature measurements in the tumor region. Results: In total, 17 hot spot reports occurred during the 14 sessions, and the alternative settings predicted the hot spot temperature to decrease by at least 0.5°C, which was confirmed by the disappearance of all 17 hot spot reports. At the same time, the average tumor temperature was predicted to change on average −0.01°C (range, −0.19°C to 0.34°C). The measured tumor temperature change was on average only −0.02°C (range, −0.26°C to 0.31°C). In only 2 cases the temperature decrease was slightly larger than 0.2°C, but at most it was 0.26°C. Conclusions: Online application of hyperthermia treatment planning is reliable and very useful to reduce hot spots without affecting tumor temperatures.

62 RADIOLOGY AND NUCLEAR MEDICINE↗