Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “GAMMA RADIATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

[A NASA / University Joint Venture in Space Science]

MILAGRO is a water-Cherenkov detector for observing cosmic gamma rays over a broad energy range of 100 GeV to 100 TeV. MILAGRO will be the first detector that has sensitivity overlapping both air-Cherenkov and air-shower detectors. With this detector scientists in the collaboration will study previously observed celestial sources at their known emission energies, extend these observations into a new energy regime, and search for new sources at unexplored energies. The diffuse gamma-radiation component in our galaxy, which originates from interactions of cosmic rays with interstellar gas and photons, provides important information about the density, distribution, and spectrum of the cosmic rays that pervade the interstellar medium. Events in the Compton Gamma Ray Observatory (GRO) are being observed up to about 30 GeV, differing by slightly more than order of magnitude from the low energy threshold of MILAGRO. By looking in coincidence at sources, correlated observations will greatly extend the astrophysics potential of MILAGRO and NASA's GRO. A survey of cosmic-ray observatories is being prepared for scientists and others to provide a resource and reference which describes high energy cosmic-ray research activities around the world. This summary presents information about each research group, such as names of principal investigators, number of persons in the collaboration, energy range, sensitivity, angular resolution, and surface area of detector. Similarly, a survey of gamma-ray telescopes is being prepared to provide a resource and reference which describes gamma-ray telescopes for investigating galactic diffuse gamma-ray flux currently observed in the GeV energy range, but is expected to extend into the TeV range. Two undergraduate students are compiling information about gamma-ray telescopes and high energy cosmic-ray observatories for these surveys. Funding for this project was provided by the Arkansas Space Grant Consortium. Also enclosed Appendix A, B, C, D and E.

Wold, Donald C.↗

The Reactivity of Polyethylene Microplastics in Water under Low Oxygen Conditions Using Radiation Chemistry

Polyethylene (PE) is an intensely utilized polymer, which has consequently led to it becoming a common environmental contaminant. PE and other plastic waste are known to be highly persistent in surface waters; however, chemical and physical changes do take place over time, dependent mostly on highly variable natural conditions, such as oxygen (O2) availability. Gamma radiation was used to generate reactive oxygen species, namely hydroxyl radicals, in initially aerated aqueous solutions to simulate the natural weathering of microplastics in waters where there are fluctuations and often depletions in dissolved O2. The headspace of the irradiated PE-containing solutions was probed for the formation of degradation products using solid-phase microextraction (SPME) fibers in combination with gas chromatography mass spectrometry (GCMS). The major species detected were n-dodecane, with trace levels of tridecane, 2-dodecanone, and hexadecane, which were believed to be predominately adsorbed in the PE microplastics in excess of their aqueous solubility limits. Surface characterization by Raman spectroscopy and light and dark field microscopy indicated no change in the chemical composition of the irradiated PE microplastics under low O2 to anaerobic conditions. However, morphological changes were observed, indicating radical combination reactions.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

LDRD 227829: Multifunctional Composite LDRD: Radiation Effect on CeO 2 -HDPE Composites

Commercial high-density polyethylene (HDPE) is lightweight with excellent mechanical properties but has limited thermal stability. To enhance this, lanthanide-based nanomaterials like CeO 2 were mixed with HDPE. Using a twin-screw extruder improved dispersion. This study examines the effects of neutron, X-rays and gamma radiation on the crystallinity of polymer of CeO 2 -HDPE composites.

36 MATERIALS SCIENCE↗

Dosimetry for radiobiological studies of the human hematopoietic system

A system for estimating individual bone marrow doses in therapeutic radiation exposures of leukemia patients was studied. These measurements are used to make dose response correlations and to study the effect of dose protraction on peripheral blood cell levels. Three irradiators designed to produce a uniform field of high energy gamma radiation for total body exposures of large animals and man are also used for radiobiological studies.

Beck, W. L.↗

The response of a 0.03-cm silicon detector to a mixed neutron and gamma field as a function of shield material and thickness

The neutron and gamma radiation from a MHW-RTG was used to evaluate the total response of a shielded 0.3-mm silicon detector. The generator employs a 2200 W(th) PuO2 heat source concept known as the HELIPAK. The total integrated neutron and gamma ray fluxes at 100 cm away from the source along the radial direction were 1.67 x 1,000 n/sq cm/s and 1.49 x 10,000 gamma sq cm/s, respectively. Experimental values of the response function of the shielded silicon detector were used to determine the total counting rates due to photons at bias energies ranging from 50 to 200 keV. For neutrons, analytically computed response functions were used to determine the total counting rates at the same bias energies. It was found that for an aluminum shield the neutrons are not significant, regardless of the thickness of the shield. However, the magnitude of the total counting rate due to neutrons increases with increased atomic number of the shield and becomes comparable to the counting rate due to photons for a platinum shield thickness of 5 cm.

Taherzadeh, M.↗

Preliminary Evaluation of Commercial Off the Shelf (COTS) Packing Materials for Flight Medication Dispenser (FMD) Technology Development

With the advent of longer duration space missions, pharmaceutical use in space has increased. During the first 33 space shuttle missions, crew members took more than 500 individual doses of 31 different medications . Anecdotal reports from crew members described medications as generally "well tolerated" and "effective". However, reported use of increased medication doses and discrepancies in ground vs. flight efficacy may result from reduced potency or altered bioavailability due to changes in chemical and/or physical parameters of pharmaceutical stability. Based on preliminary results from a ground-based irradiation and an inflight study on pharmaceutical stability, three susceptible medications, Amoxicillin/Clavulanate and Sulfamethoxazole/trimethoprim antibiotics tablets and promethazine (PMZ), an antihistamine were selected for testing using two types of Oliver-Tolas bags, TPC-1475(Clear) and TPF-0599B (Foil) for radiation Shielding effectiveness. The material composition of the bags included aluminum coated Mylar sheathing coated with multifunctional nanocomposities based on polyethylene with dispersed boron-rich nanophases. Two bags of each medication were irradiated for different time intervals with 14.6 rad/min to achieve 0.1 Gy, 1 Gy and 10 Gy of cumulative radiation dose. Active pharmaceutical content (API) in each medication was determined and results analyzed. No significant difference in API content was observed between control and irradiated samples for both antibiotic tablets suggesting both types of bags may offer protection against gamma radiation; results with PMZ were inconclusive. These preliminary results suggest that Oliver-Tolas TPL-1475 and TPF-0599B materials may possess characteristics suitable for protection against ionizing radiation and can be considered for designing and further testing of FMD technology.

Du, Brian↗

Channeling and radiation experiments at SLAC

Since 2014, a SLAC-Aarhus-Ferrara-CalPoly collaboration augmented by members of ANL and MIT has performed electron and positron channeling experiments using bent silicon crystals at the SLAC End Station A Test Beam as well as the FACET accelerator test facility. These experiments have revealed a remarkable channeling efficiency of about 24% under our conditions. Volume reflection is even more efficient with almost the whole beam taking part in the reflection process. A positron experiment demonstrated quasi-channeling oscillations for the first time at high beam energy. In our most recent experiment we measured the spectrum of gamma radiation for crystal orientations covering channeling and volume reflection. We report this series of experiments supports the development of more advanced crystalline devices capable e.g. of producing narrow-band gamma rays with electron beams or studying the interaction of the electrons with the wakefields generated in the crystal at high beam intensity.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

CGRO Observations

This final report presents an investigation of the CGRO (Compton Gamma Ray Observatory) observations. The investigation includes: Diffuse Gamma-Ray Emission at High Latitudes; and Echoes in X-Ray Novae; A Localized Excess of Gamma-Radiation; Transient Hard X-Ray Emission from Globular Clusters; and A Search for Be/X-Ray Binaries in Hard X-Rays; Hard X-Ray Emission from X-Ray Bursters; X-Ray Transients in Star-Forming Regions; Gamma-ray Emission from Globular Clusters; Shock High Energy Emission from Be-Star/Pulsar System PSR 1259-63m; Gamma-Ray Spectroscopy of Nearby OB Associations; Long Term Hard X-Ray Monitoring of X-Ray Busters; and Periodic Hard X-Ray Emission from GRO J1849-03.

Kaaret, Philip↗

On the binary nature of cosmic gamma-ray burst sources

The binary model of gamma ray burst sources wherein the bursts are emitted by a collapsed object in a close-binary stellar system and a small fraction of the gamma radiation is reprocessed into optical radiation in the surface layers of a companion star is considered, and it is concluded that the model is viable. In particular, under the assumption that the optical flashes discovered by Schaefer (1981) and Schaefer et al. (1984) were produced by gamma-ray bursts of about the same intensity as those observed, it is found that nearby binary systems with secondaries whose masses are less than about 0.06 solar mass can fit all the observational constraints for the three optical/gamma-ray pair events.

Rappaport, S. A.↗

Detection of a long-duration solar gamma-ray flare on Jun. 11, 1991 with EGRET on Compton-GRO

On 11 Jun. 1991, the Energetic Gamma Ray Experiment Telescope (EGRET) on the Compton Gamma Ray Observatory (Comption-GRO) observed high energy gamma radiation above 30 MeV from the Sun following an intense flare around 2:00 Universal Time (UT). After the decay of most of the x ray flare, which caused nearly complete deadtime losses in EGRET, high energy emission was registered during the interval from about 3:30 UT to at least 10:30 UT. Gamma rays were detected up to energies above 1 GeV. The solar origin of the emission is assured by the time profile of the gamma ray count rate and by time resolved sky maps, which show a clear maximum at the position of the sun. The gamma ray lightcurve of the flare can be described with two components: a fast decaying emission with an e-folding time constant of about 25 minutes and a slow decay with about 255 minutes. There are indications for a spectral evolution with time, such that the emission below 100 MeV fades away earlier than the 100 to 300 MeV radiation, roughly in the time scale of the fast component. The spectrum of the flare can be fitted with a composite of a proton generated pion neutral spectrum and an electron bremsstrahlung component. The latter can be identified with the fast decaying component of the lightcurve.

Kanbach, G.↗

Pair Production near Threshold in Pulsar Magnetic Fields

In pulsar polar cap models, curvature radiation gamma rays produce e(+)e(-) pairs in the strong magnetic fields near the surface of the neutron star. While these gamma rays have energies E sub gamma mc(2), they also propagate at very small angles to the fields, such that the threshold condition, E gamma 2mc(2)/sin theta is just barely satisfied when they pair produce. Threshold effects on the pair production attenuation coefficient, which are due to the discreteness of the e(+)e(-) Landau states, must therefore be considered when computing the mean free paths of curvature radiation photons in pulsar magnetic fields. These effects, which are not incorporated in the asymptotic expression for the attenuation coefficient, have some interesting consequences for pulsar models. Since pair production is suppressed near threshold, the photon mean free paths are longer than previously thought. In magnetic fields approximately 6x10 approximately G, the pairs tend to be produced in the ground state Landau level and will not synchrotron radiate. Since synchrotron radiation is an essential ingredient in the electromagnetic cascades which produce low energy pairs above the acceleration region, pulsars with very high magnetic fields may not produce many pairs.

Harding, A. K.↗

GRO: Studies of High Energy Pulsars with EGRET

The Energetic Gamma-Ray Experiment Telescope (EGRET) on the Compton Gamma Ray Observatory has observed PSR B1706-44 a number of times between 1991 and 1995. From these data, a more detailed picture of the gamma radiation from this source has been developed, showing several characteristics that distinguish this pulsar from others: the light curve is complex, with evidence of three pulses; there is no detectable unpulsed emission; and the energy spectrum changes slope at 1 GeV. No two of the known gamma-ray pulsars have quite the same characteristics; this diversity makes interpretation in terms of theoretical models difficult.

Ruderman, Malvin↗

Radiation Testing for High-Resolution Radiation-Hardened Camera System (Final CRADA Report)

The nuclear energy industry needs higher-image quality and higher rad-hard vision systems for refueling and inspection operations that are required every 12-18 months for all operating commercial reactors. During refueling operations, the serial numbers of fuel assemblies need to be visually verified in a challenging high radiation environment with dose rates on the order of 1kGy/hr. at the top of the core (approximately 10 days after shutdown). Vega Wave Systems has developed and built a radiation hard vision system that: 1. has high radiation hardness, 2. demonstrated best in the industry image quality, 3. has small size and weight, and 4. does not suffer from radiation-induced noise. ANL-1060 (02/13/2023) The proprietary Enduray vision system from Vega Wave Systems, Inc. is designed to withstand more than 400x the radiation level of the Vidicon-based systems, currently the highest radiation tolerant system in use today. The Van De Graaff (VDG) electron accelerator at Argonne National Laboratory is ideally suited for testing of Enduray vision system. VDG provides a broad band (up to 3 MeV) x-ray source that reasonably approximates the energy and spectrum of the gamma radiation expected at the top of a nuclear core 10 days after shutdown (~1kGy/hr.), is easily controlled for variable tests, and will not activate the parts under radiation for ease of timely and close inspection and characterization of the system in case of operational issues.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Simulated Galactic Cosmic Ray and Solar Particle Event Radiation Effects on Inflatable Habitat, Composite Habitat, Space Suit and Space Hatch Cover Materials

The effect of particle radiation representative of galactic cosmic ray (GCR) and solar particle event (SPE) radiation on polymeric materials used in deep space mission environments is largely unknown. For NASA, this uncertainty represents an unquantified mission risk. To better quantify this risk, selected polymeric materials used in inflatable habitats, composite habitats, space suits and space hatch covers are irradiated at the Brookhaven National Laboratory, after which changes in relevant end-use properties are measured. The irradiated materials are lightweight candidates having critical functions such as ripstops, permeation barriers, micrometeoroids and orbital debris (MMOD) shield layers and restraint layers.The effect of several types of particle radiation are evaluated. To evaluate GCR effects, high-energy (1 GeV) protons and iron nucleons are used. To evaluate SPE effects, intermediate energy (ca. 20 to 40 MeV) protons are used. In addition, two mission scenarios are evaluated: a Mars mission cycle (space suit materials) and a worst-case 50 year deep space mission cycle (all materials). Lastly, a common polymer (high density polyethylene (HDPE)) is subjected to accelerated aging and radiation exposure to determine if a combined physical aging/radiation effect exists.The level of radiation induced property change observed in this study after exposure of polymers to kGy levels of intermediate and high energy ions is often significant and is quantitatively comparable to the level of change reported for similar materials exposed to MGy levels of low energy protons, electrons and gamma-radiation. This suggests that intermediate and high energy ions encountered in space may cause more damage than low energy forms of radiation due to displacement and linear energy transfer (LET) effects. For these reasons, it is recommended that final approval for mission use be made by the appropriate NASA material and structural review boards to ensure radiation induced changes in candidate materials do not interfere with their engineering function in the intended mission application. Since the materials tested in this report received doses exceeding actual mission doses, the results are considered conservative as a first approximation. However, caution must be exercised when evaluating radiation effects in the absence of other secondary factors know to contribute to degradation. In the addition to radiation type and energy, the results presented in this study show that molecular composition, orientation, stress and physical aging can also contribute to or influence degradation. Other factors such as polymer formulation, secondary radiation effects, stress, exposure to elevated temperature, thermal cycling and exposure to ozone were not investigated here, but must be considered when performing a comprehensive evaluation of a polymeric materials suitability for service in a space radiation environment. Only when the total sum of these factors operating in concert with radiation are accounted for, can accurate assessments of a material's suitability be made.

Jess M. Waller↗

Neuro-behavioral Consequences of Low Dose Radiation Social Isolation and Sex Differences in the Longevity MCAT Mouse Model

The physiological responses to spaceflight elicit wide-ranging consequences and resemble aspects of aging on Earth. Previous studies have shown that oxidative damage via reactive oxygen species (ROS), contributes to aging-related pathologies. Our study uses 1-year old C57BL/6NJ male and female mice (astronaut-relevant age) that underwent exposure to 0.5 gray of gamma radiation together with social isolation and were euthanized 12 weeks after. We used the longevity MCAT mouse model in which human catalase is overexpressed in the mitochondria, for ROS quenching. We aimed to determine whether in older mice quenching ROS, will mitigate the neuro-behavioral consequences of low dose ionizing radiation and/or social isolation and whether the outcomes will differ in males and females. We have performed five mission relevant behavioral tests which focused on performance, memory, physical stance, and stress. We have detected both sex and radiation effects; the older females look physically better are faster and perform better almost in all behavioral tests compared to their male counterparts. On the other hand, they are more sensitive to low dose radiation in many cases, in some cases this effect was indeed mitigated in the MCAT mice, pointing out to the importance of ROS in response to radiation stress and social isolation. We have measured plasma (7- and 90-days post radiation), cytokines, corticosterone and hippocampal cytokine and microglial activation at the end of the experiment. We saw significant changes in the plasma markers due to radiation, sex, and genotype in both short and long post radiation period and detected long term sex and radiation effects in the brain. Our focus is now on applying advanced statistical modeling to corelate the behavioral tests with our recent molecular findings to look for specific biomarkers that could predict behavioral deficits.

radiation↗

Optical reprocessing of gamma-ray bursts

One model for the optical flashes associated with three cosmic gamma-ray burst sources invokes the reprocessing of some of the gamma-radiation emitted by a hypothesized collapsed object in the surface layers of a nearby companion star. This model was investigated by carrying out detail, fully hydrodynamical calculations of such reprocessing in the surface layers of very low mass stars. It is found that, at most, 7 percent of the gamma-ray fluence incident on the companion star is reprocessed into the blue band; the time scale for this reprocessing is typically 100 s, which is long compared to the duration of the gamma-ray burst itself. Using this result, it is shown that there is marginal agreement between the observed and calculated ratios of gamma-ray fluence to optical fluence at earth.

Melia, F.↗

Antiproton powered propulsion with magnetically confined plasma engines

Matter-antimatter annihilation releases more energy per unit mass than any other method of energy production, making it an attractive energy source for spacecraft propulsion. In the magnetically confined plasma engine, antiproton beams are injected axially into a pulsed magnetic mirror system, where they annihilate with an initially neutral hydrogen gas. The resulting charged annihilation products transfer energy to the hydrogen propellant, which is then exhausted through one end of the pulsed mirror system to provide thrust. The calculated energy transfer efficiencies for a low number density (10(14)/cu cm) hydrogen propellant are insufficient to warrant operating the engine in this mode. Efficiencies are improved using moderate propellant number densities (10(16)/cu cm), but the energy transferred to the plasma in a realistic magnetic mirror system is generally limited to less than 2 percent of the initial proton-antiproton annihilation energy. The energy transfer efficiencies are highest for high number density (10(18)/cu cm) propellants, but plasma temperatures are reduced by excessive radiation losses. Low to moderate thrust over a wide range of specific impulse can be generated with moderate propellant number densities, while higher thrust but lower specific impulse may be generated using high propellant number densities. Significant mass will be required to shield the superconducting magnet coils from the high energy gamma radiation emitted by neutral pion decay. The mass of such a radiation shield may dominate the total engine mass, and could severely diminish the performance of antiproton powered engines which utilize magnetic confinement. The problem is compounded in the antiproton powered plasma engine, where lower energy plasma bremsstrahlung radiation may cause shield surface ablation and degradation.

Lapointe, Michael R.↗

Design of a high-temperature cell for cobalt-60 irradiations of aqueous solutions with in situ UV–visible spectroscopy

To understand the speciation of solutes in aqueous solutions in high temperature radiation environments, we report the design and fabrication of a custom-built, high temperature (≤300 °C) titanium irradiation cell with in situ optical spectroscopy capabilities, as afforded by coupled fiber optic cables. The wetted surfaces of the 8-inch tall cylindrical cell with 3.5 in. diameter are entirely made of titanium, sapphire, and gold, which are chemically and radiolytically inert. The initial benchmarking results are reported, including the baseline spectrum of deionized water as a function of temperature, the stability of a spectrum over 4 h at 100 °C, and an irradiated Fricke dosimetry solution under ambient irradiator temperature conditions (27.0 ± 0.5 °C). Further, the average gamma radiation dose rate in the cell in its current configuration is 26.1 ± 1.3 Gy min -1 . This cell has application in studying several processes throughout the nuclear fuel cycle, including the reactor coolant behavior.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗