Design considerations for a 10-kW integrated hydrogen-oxygen regenerative fuel cell system

Integration of an alkaline fuel cell subsystem with an alkaline electrolysis subsystem to form a regenerative fuel cell (RFC) system for low earth orbit (LEO) applications characterized by relatively high overall round trip electrical efficiency, long life, and high reliability is possible with present state of the art technology. A hypothetical 10 kW system computer modeled and studied based on data from ongoing contractual efforts in both the alkaline fuel cell and alkaline water electrolysis areas. The alkaline fuel cell technology is under development utilizing advanced cell components and standard Shuttle Orbiter system hardware. The alkaline electrolysis technology uses a static water vapor feed technique and scaled up cell hardware is developed. The computer aided study of the performance, operating, and design parameters of the hypothetical system is addressed.

Hoberecht, M. A.↗

Design considerations for a 10-kW integrated hydrogen-oxygen regenerative fuel cell system

Integration of an alkaline fuel cell subsystem with an alkaline electrolysis subsystem to form a regenerative fuel cell (RFC) system for low earth orbit (LEO) applications characterized by relatively high overall round trip electrical efficiency, long life, and high reliability is possible with present state of the art technology. A hypothetical 10 kW system computer modeled and studied based on data from ongoing contractual efforts in both the alkaline fuel cell and alkaline water electrolysis areas. The alkaline fuel cell technology is under development utilizing advanced cell components and standard Shuttle Orbiter system hardware. The alkaline electrolysis technology uses a static water vapor feed technique and scaled up cell hardware is developed. The computer aided study of the performance, operating, and design parameters of the hypothetical system is addressed.

Hoberecht, M. A.↗

Fuel cell technology program

A fuel cell technology program was established to advance the state-of-the art of hydrogen oxygen fuel cells using low temperature, potassium hydroxide electrolyte technology as the base. Cell and component testing confirmed that low temperature, potassium hydroxide electrolyte technology is compatible with the requirements of the space shuttle Phase B contractors. Testing of the DM-1 powerplant demonstrated all of the important requirements of the shuttle except operating life. Testing also identified DM-1 powerplant life limiting mechanisms; hydrogen pump gear wear and pressurization of the cell stack over its design limits.

Source record↗

Process Developed for Generating Ceramic Interconnects With Low Sintering Temperatures for Solid Oxide Fuel Cells

Solid oxide fuel cells (SOFCs) have been considered as premium future power generation devices because they have demonstrated high energy-conversion efficiency, high power density, and extremely low pollution, and have the flexibility of using hydrocarbon fuel. The Solid-State Energy Conversion Alliance (SECA) initiative, supported by the U.S. Department of Energy and private industries, is leading the development and commercialization of SOFCs for low-cost stationary and automotive markets. The targeted power density for the initiative is rather low, so that the SECA SOFC can be operated at a relatively low temperature (approx. 700 C) and inexpensive metallic interconnects can be utilized in the SOFC stack. As only NASA can, the agency is investigating SOFCs for aerospace applications. Considerable high power density is required for the applications. As a result, the NASA SOFC will be operated at a high temperature (approx. 900 C) and ceramic interconnects will be employed. Lanthanum chromite-based materials have emerged as a leading candidate for the ceramic interconnects. The interconnects are expected to co-sinter with zirconia electrolyte to mitigate the interface electric resistance and to simplify the processing procedure. Lanthanum chromites made by the traditional method are sintered at 1500 C or above. They react with zirconia electrolytes (which typically sinter between 1300 and 1400 C) at the sintering temperature of lanthanum chromites. It has been envisioned that lanthanum chromites with lower sintering temperatures can be co-fired with zirconia electrolyte. Nonstoichiometric lanthanum chromites can be sintered at lower temperatures, but they are unstable and react with zirconia electrolyte during co-sintering. NASA Glenn Research Center s Ceramics Branch investigated a glycine nitrate process to generate fine powder of the lanthanum-chromite-based materials. By simultaneously doping calcium on the lanthanum site, and cobalt and aluminum on the chromium site, we could sinter the materials below 1400 C. The doping concentrations were adjusted so that the thermal expansion coefficient matched that of the zirconia electrolyte. Also, the investigation was focused on stoichiometric compositions so that the materials would have better stability. Co-sintering and chemical compatibility with zirconia electrolyte were examined by X-ray diffraction, scanning electron microscopy, and energy dispersive spectroscopy (line scanning and dot map). The results showed that the materials bond well, but do not react, with zirconia electrolyte. The electric conductivity of the materials measured at 900 C in air was about 20 S/cm.

Zhong, Zhi-Min↗

Fuel cell technology program

A fuel cell technology program was established to advance the state-of-the-art of hydrogen-oxygen fuel cells using low temperature, potassium hydroxide electrolyte technology as the base. Program tasks are described consisting of baseline cell design and stack testing, hydrogen pump design and testing, and DM-2 powerplant testing and technology extension efforts. A baseline cell configuration capable of a minimum of 2000 hours of life was defined. A 6-cell prototype stack, incorporating most of the scheme cell features, was tested for a total of 10,497 hours. A 6-cell stack incorporating all of the design features was tested. The DM-2 powerplant with a 34 cell stack, an accessory section packaged in the basic configuration anticipated for the space shuttle powerplant and a powerplant control unit, was defined, assembled, and tested. Cells were used in the stack and a drag-type hydrogen pump was installed in the accessory section. A test program was established, in conjunction with NASA/JSC, based on space shuttle orbiter mission. A 2000-hour minimum endurance test and a 5000-hour goal were set and the test started on August 8, 1972. The 2000-hour milestone was completed on November 3, 1972. On 13 March 1973, at the end of the thirty-first simulated seven-day mission and 5072 load hours, the test was concluded, all goals having been met. At this time, the DM-2 was in excellent condition and capable of additional endurance.

Source record↗

The TMI regenerable solid oxide fuel cell

Energy storage and production in space requires rugged, reliable hardware which minimizes weight, volume, and maintenance while maximizing power output and usable energy storage. These systems generally consist of photovoltaic solar arrays which operate during sunlight cycles to provide system power and regenerate fuel (hydrogen) via water electrolysis; during dark cycles, hydrogen is converted by the fuel cell into system. The currently preferred configuration uses two separate systems (fuel cell and electrolyzer) in conjunction with photovoltaic cells. Fuel cell/electrolyzer system simplicity, reliability, and power-to-weight and power-to-volume ratios could be greatly improved if both power production (fuel cell) and power storage (electrolysis) functions can be integrated into a single unit. The Technology Management, Inc. (TMI), solid oxide fuel cell-based system offers the opportunity to both integrate fuel cell and electrolyzer functions into one unit and potentially simplify system requirements. Based an the TMI solid oxide fuel cell (SOPC) technology, the TMI integrated fuel cell/electrolyzer utilizes innovative gas storage and operational concepts and operates like a rechargeable 'hydrogen-oxygen battery'. Preliminary research has been completed on improved H2/H2O electrode (SOFC anode/electrolyzer cathode) materials for solid oxide, regenerative fuel cells. Improved H2/H2O electrode materials showed improved cell performance in both fuel cell and electrolysis modes in reversible cell tests. ln reversible fuel cell/electrolyzer mode, regenerative fuel cell efficiencies (ratio of power out (fuel cell mode) to power in (electrolyzer model)) improved from 50 percent (using conventional electrode materials) to over 80 percent. The new materials will allow the TMI SOFC system to operate as both the electrolyzer and fuel cell in a single unit. Preliminary system designs have also been developed which indicate the technical feasibility of using the TMI SOFC technology for space applications with high energy storage efficiencies and high specific energy. Development of small space systems would also have potential dual-use, terrestrial applications.

Cable, Thomas L.↗

Test of Hydrogen-Oxygen PEM Fuel Cell Stack at NASA Glenn Research Center

This paper describes performance characterization tests of a 64 cell hydrogen oxygen PEM fuel cell stack at NASA Glenn Research Center in February 2003. The tests were part of NASA's ongoing effort to develop a regenerative fuel cell for aerospace energy storage applications. The purpose of the tests was to verify capability of this stack to operate within a regenerative fuel cell, and to compare performance with earlier test results recorded by the stack developer. Test results obtained include polarization performance of the stack at 50 and 100 psig system pressure, and a steady state endurance run at 100 psig. A maximum power output of 4.8 kWe was observed during polarization runs, and the stack sustained a steady power output of 4.0 kWe during the endurance run. The performance data obtained from these tests compare reasonably close to the stack developer's results although some additional spread between best to worst performing cell voltages was observed. Throughout the tests, the stack demonstrated the consistent performance and repeatable behavior required for regenerative fuel cell operation.

Bents, David J.↗

Fuel cell technology for lunar surface operations

Hydrogen-oxygen fuel cells have been shown, in several NASA and contractor studies, to be an enabling technology for providing electrical power for lunar bases, outposts, and vehicles. The fuel cell, in conjunction with similar electrolysis cells, comprises a closed regenerative energy storage system, commonly referred to as a regenerative fuel cell (RFC). For stationary applications, energy densities of 1,000 watt-hours per kilograms an order of magnitude over the best rechargeable batteries, have been projected. In this RFC, the coupled fuel cell and electrolyzer act as an ultra-light battery. Electrical energy from solar arrays 'charges' the system by electrolyzing water into hydrogen and oxygen. When an electrical load is applied, the fuel cell reacts the hydrogen and oxygen to 'discharge' usable power. Several concepts for utilizing RFC's, with varying degrees of integration, have been proposed, including both primary and backup roles. For mobile power needs, such as rovers, an effective configuration may be to have only the fuel cell located on the vehicle, and to use a central electrolysis 'gas station'. Two fuel cell technologies are prime candidates for lunar power system concepts: alkaline electrolyte and proton exchange membrane. Alkaline fuel cells have been developed to a mature production power unit in NASA's Space Shuttle Orbiter. Recent advances in materials offer to significantly improve durability to the level needed for extended lunar operations. Proton exchange membrane fuel cells are receiving considerable support for hydrospace and terrestrial transportation applications. This technology promises durability, simplicity, and flexibility.

Deronck, Henry J.↗

Fuel Cell Activities at the NASA Glenn Research Center

Fuel cells have a long history in space applications and may have potential application in aeronautics as well. A fuel cell is an electrochemical energy conversion device that directly transforms the chemical energy of a fuel and oxidant into electrical energy. Alkaline fuel cells have been the mainstay of the U.S. space program, providing power for the Apollo missions and the Space Shuttle. However, Proton Exchange Membrane (PEM) fuel cells offer potential benefits over alkaline systems and are currently under development for the next generation Reusable Launch Vehicle (RLV). Furthermore, primary and regenerative systems utilizing PEM technology are also being considered for future space applications such as surface power and planetary aircraft. In addition to these applications, the NASA Glenn Research Center is currently studying the feasibility of the use of both PEM and solid oxide fuel cells for low- or zero-emission electric aircraft propulsion. These types of systems have potential applications for high altitude environmental aircraft, general aviation and commercial aircraft, and high attitude airships. NASA Glenn has a unique set of capabilities and expertise essential to the successful development of advanced fuel cell power systems for space and aeronautics applications. NASA Glenn's role in past fuel cell development programs as well as current activities to meet these new challenges will be presented

Kohout, Lisa L.↗

Fuel Cells Utilizing Oxygen From Air at Low Pressures

A fuel cell stack has been developed to supply power for a high-altitude aircraft with a minimum of air handling. The fuel cell is capable of utilizing oxygen from ambient air at low pressure with no need for compression. For such an application, it is advantageous to take oxygen from the air (in contradistinction to carrying a supply of oxygen onboard), but it is a challenging problem to design a fuel-cell stack of reasonable weight that can generate sufficient power while operating at reduced pressures. The present fuel-cell design is a response to this challenge. The design features a novel bipolar plate structure in combination with a gas-diffusion structure based on a conductive metal core and a carbon gas-diffusion matrix. This combination makes it possible for the flow fields in the stack to have a large open fraction (ratio between open volume and total volume) to permit large volumes of air to flow through with exceptionally low backpressure. Operations at reduced pressure require a corresponding increase in the volume of air that must be handled to deliver the same number of moles of oxygen to the anodes. Moreover, the increase in the open fraction, relative to that of a comparable prior fuel-cell design, reduces the mass of the stack. The fuel cell has been demonstrated to operate at a power density as high as 105 W/cm2 at an air pressure as low as 2 psia (absolute pressure 14 kPa), which is the atmospheric pressure at an altitude of about 50,000 ft ( 15.2 km). The improvements in the design of this fuel cell could be incorporated into designs of other fuel cells to make them lighter in weight and effective at altitudes higher than those of prior designs. Potential commercial applications for these improvements include most applications now under consideration for fuel cells.

Cisar, Alan↗

Protecting Fuel Cells From Drowning

Water in fuel cell extracted before it reaches cells. Stack of fuel cells gets supply of hydrogen from manifold. Heat-exchanger plate and reservoir collect water from flow of hydrogen. Water in reservoir evaporated with heat from coolant heat-exchanger plate.

Suljak, George T.↗

Mesoscopic analyses of the impact of morphology and operating conditions on the transport resistances in a proton-exchange-membrane fuel-cell catalyst layer

Exploring the origins of local transport resistance and characterizing the oxygen transport resistances in the catalyst layer (RCL) are critical for cost reduction. In this paper, a comprehensive mesoscopic model for simulating coupled transport processes of oxygen and water vapor for different structural parameters under different operating conditions in reconstructed microstructures is proposed. The local transport resistance is calculated after achieving the limiting current density and the effective diffusivity of oxygen. The results demonstrate that RCL increases greatly with decreasing platinum loading (LPt) and the transport resistances in other components of the cell dominate for high-loadings. Both the reduced oxygen permeation coefficient in the ionomer thin-film and the adsorption resistance account for the origins of local transport resistance. The local transport resistance increases with the bare carbon ratio for a constant LPt and Pt/C ratio due to the decreased effective ionomer surface, and increases with the I/C ratio due to the increased ionomer thickness and decreased Knudsen diffusivity. Due to the presence of liquid water, a slight decrease followed by an increase of the local transport resistance versus relative humidity is obtained. The contribution of ionomer thin-films to RCL is more sensitive to liquid saturation compared with that of pores. This journal is

Mu, YT↗

Three-dimensional ionic conduction in the strained electrolytes of solid oxide fuel cells

Flexible power sources including fuel cells and batteries are the key to realizing flexible electronic devices with pronounced foldability. To understand the bending effects in these devices, theoretical analysis on three-dimensional (3-D) lattice bending is necessary. In this report, we derive a 3-D analytical model to analyze the effects of electrolyte crystal bending on ionic conductivity in flexible solid-state batteries/fuel cells. By employing solid oxide fuel cells as a materials' platform, the intrinsic parameters of bent electrolyte materials, including lattice constant, Young's modulus, and Poisson ratio, are evaluated. Our work facilitates the rational design of highly efficient flexible electrolytes for high-performance flexible device applications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Asymmetric electrode ionomer for low relative humidity operation of anion exchange membrane fuel cells

The operation of fuel cells under low relative humidity (RH) conditions gives substantial cost and performance benefits. Nonetheless, it is not currently feasible to operate anion exchange membrane fuel cells (AEMFCs) at low RH conditions because current materials for membrane electrode assembly cannot provide sufficient water for the oxygen reduction reaction. In this work, we synthesized polyfluorene ionomers with different ammonium concentrations for anode and cathode to control water management. We designed several asymmetric electrodes that enable high performance under low RH conditions via not only conventional backward water diffusion (anode to cathode) but also forward diffusion (cathode to anode). The AEMFCs using optimized asymmetric electrodes exhibited high H 2 /CO 2 -free air performance (rated power density of circa 540 mW cm -2 at 90 °C under 75% (anode) and 50% RH (cathode) conditions), which is comparable to those of state-of-the-art AEMFCs under nearly water-saturated conditions. The durability of the AEMFCs is excellent, generating 0.6 A cm -2 for >900 h at 80 °C under 50% RH (cathode) conditions. This study demonstrates that high-performance and durable AEMFCs under low RH and high current generating conditions are possible.

25 ENERGY STORAGE↗

Insights on the extraordinary tolerance to alcohols of Fe-N-C cathode catalysts in highly performing direct alcohol fuel cells

Direct alcohol fuel cells (DAFCs) represent the best alternative to batteries for portable and auxiliary power units application due to the high energy density of short chain alcohols. Currently, the utilization of the best platinum group metal (PGM) cathode catalysts is limited, not only by a high cost and scarce resources, but also by the inefficient oxygen reduction reaction (ORR) when permeated alcohols adsorb on the catalytic active sites. In this work, a highly active Fe-N-C catalyst derived from the pyrolysis of nicarbazin (a nitrogen charge transfer organic salt) and an iron precursor has been investigated to get insights on the extraordinary tolerance to the presence of alcohols (methanol and ethanol) of such a PGM-free catalyst. Density functional theory (DFT) calculations demonstrate for the first time that Fe-N 4 and Fe-N 2 C 2 active sites preferentially adsorb oxygen with much higher energy than methanol, ethanol and products of partial ethanol oxidation (0.73–1.16 eV stronger adsorption), while nitrogen-carbon related sites (pyridinic and graphitic nitrogen) are much less selective towards ORR. Half-cell electrochemical characterization showed that the Fe-N-C catalyst overcomes Pt ORR activity in acidic medium with methanol or ethanol concentrations as low as 0.01 M. The feasibility of DAFCs operation based on high methanol (up to 17 M) and ethanol (up to 5 M) concentration thanks to the utilization of Fe-N-C cathode catalyst is demonstrated. Lastly, a new strategy is proposed for DAFCs where using Pt only at the anode and Fe-N-C at the cathode allows extending the device energy density compared to PGM-based catalysts at both electrodes.

30 DIRECT ENERGY CONVERSION↗

Duty Cycling Influences Current Generation in Multi-Anode Environmental Microbial Fuel Cells

Improving microbial fuel cell (MFC) performance continues to be the subject of research, yet the role of operating conditions, specifically duty cycling, on MFC performance has been modestly addressed. We present a series of studies in which we use a 15-anode environmental MFC to explore how duty cycling (variations in the time an anode is connected) influences cumulative charge, current, and microbial composition. The data reveal particular switching intervals that result in the greatest time-normalized current. When disconnection times are sufficiently short, there is a striking decrease in current due to an increase in the overall electrode reaction resistance. This was observed over a number of whole cell potentials. Based on these results, we posit that replenishment of depleted electron donors within the biofilm and surrounding diffusion layer is necessary for maximum charge transfer, and that proton flux may be not limiting in the highly buffered aqueous phases that are common among environmental MFCs. Surprisingly, microbial diversity analyses found no discernible difference in gross community composition among duty cycling treatments, suggesting that duty cycling itself has little or no effect. Such duty cycling experiments are valuable in determining which factors govern performance of bioelectrochemical systems and might also be used to optimize field-deployed systems.

Gardel, EJ↗

Hydrogen oxidation kinetics on platinum-palladium bimetallic thin films for solid acid fuel cells

Solid acid fuel cells (SAFCs) based on the proton-conductive electrolyte CsH 2 PO 4 have shown promising power densities at an intermediate operating temperature of ~250 °C. However, Pt loadings in SAFCs remain higher than desirable, and the electrocatalysis mechanisms in these devices are still unknown. Here, hydrogen oxidation kinetics on Pt and Pt-Pd bimetallic thin film electrodes on CsH 2 PO 4 have been evaluated to establish the potential for a beneficial role of Pd in SAFC anodes. Symmetric cells fabricated by depositing a metal film on both sides of electrolyte discs are characterized for studying hydrogen electro-oxidation across the gas|metal|CsH 2 PO 4 structure. It was found that Pd reacts with CsH 2 PO 4 , forming palladium phosphide at the metal-electrolyte interface. Accordingly, the activity of Pd was examined in a bilayer geometry of Pd|Pt|CsH 2 PO 4 |Pt|Pd. The bilayer Pt|Pd films showed much higher activity for hydrogen electro-oxidation than films of Pt alone, as measured by AC impedance spectroscopy. Ex situ low energy ion scattering and scanning transmission electron microscopy revealed that Pd diffused into the Pt layer under operating conditions. The dramatic impact of Pd along with its presence throughout the film suggests that it catalyzes reactions at both the metal-gas and metal-electrolyte interfaces, as well as increasing hydrogen diffusion rates through the films.

36 MATERIALS SCIENCE↗