Organic Matter Concentration and Composition in November 2021 and April 2022 from 12 Streams Impacted by the 2020 Holiday Farm Fire (v2)

This dataset represents results from a field study aiming to understand storm induced transport of pyrogenic materials to streams impacted by varying degrees of burn severity. Time series samples were collected at 5 sites within the McKenzie River Watershed (Oregon, USA) whose catchment were each completely engulfed by the 2020 Holiday Farm Fire. An additional 7 sites were sampled once during the storm. The samples were collected during storm events in November 2020, January 2021, November 2021, and April 2022. Samples were characterized for benezenepolycarboxylic acids (BPCA), ultra-high resolution mass spectrometry, dissolved organic carbon and optics (absorbance and fluorescence). Fourier-transform ion cyclotron resonance mass spectrometry (FTICR) and dissolved organic carbon data from the November 2020 (referred to as “EWEB_2020”) sampling can be found in a separate data package (doi: 10.15485/1869708). NOTE: The 2020 samples were run on FTICR-MS in two unique instances. The first run can be found in the previous data package (EWEB_2020). The second run is included in this data package. These samples were run for a second time so that the data were more directly interoperable with the other samples in this data package. We have not done any investigation into the differences/similarities between these datasets and the previously ran/published data in the other data package. This data package was originally published in November 2024. It was updated in April 2025 (v2; new and modified files). See the change history section below for more details. For details on how to navigate data packages generated by this project, see https://data.ess-dive.lbl.gov/portals/PNNLRiverCorridorSFA/About. This dataset contains (1) file-level metadata; (2) data dictionary; (3) data package readme; (4) metadata; (5) methods information; (6) dissolved organic carbon (DOC, measured as non-purgeable organic carbon, NPOC) data; (7) excitation emission matrix (EEM) methods; and (8) a sub-folder with processed EEM data (9) benzene polycarboxylic acid (BPCA) concentration data; (10) Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS) methods; and (11) folder of high-resolution characterization of organic matter via 12 Tesla FTICR-MS generated through the Environmental Molecular Sciences Laboratory (EMSL; https://www.pnnl.gov/environmental-molecular-sciences-laboratory). The EEMs sub-folder contains two additional folders; the Absorbance and Fluorescence folders which contain the processed EEMs absorbance and fluorescence data respectively. This package contains the following file types: csv, xml, pdf.

54 ENVIRONMENTAL SCIENCES↗

System design for a million channel digital spectrum analyzer /MCSA/

The system design of a wideband (8 MHz) million-channel digital spectrum analyzer for use with a SETI receiver is presented. The analyzer makes use of a digital bandpass filter bank for transforming the wideband input signal into a specified number (120) of uniform narrowband output channels by the use of a Fourier transform digital processor combined with a prototype digital weighting network (finite impulse response filter). The output is then processed separately by 120 microprocessor-based discrete Fourier transform computers, each producing 8190 output channels of approximately 8 Hz bandwidth by the use of an 8190-point prime factor algorithm.

Peterson, A.↗

HOE/lensless matched spatial filter wavelength-scaling correlator

A scaling correlator optical pattern recognition system is described in which a lensless matched spatial filter (with the second Fourier transform lens and the matched spatial filter recorded on the same plate) is used with a first Fourier transform lens that is also an holographic optical element. The matched spatial filter is recorded at one wavelength and correlation is obtained at a second wavelength. Experimental demonstration and output correlation SNR data are reported, together with a comparison of the system's noise level using conventional optics and holographic elements.

Shen, M.↗

Pipelined digital SAR azimuth correlator using hybrid FFT-transversal filter

A synthetic aperture radar system (SAR) having a range correlator is provided with a hybrid azimuth correlator which utilizes a block-pipe-lined fast Fourier transform (FFT). The correlator has a predetermined FFT transform size with delay elements for delaying SAR range correlated data so as to embed in the Fourier transform operation a corner-turning function as the range correlated SAR data is converted from the time domain to a frequency domain. The azimuth correlator is comprised of a transversal filter to receive the SAR data in the frequency domain, a generator for range migration compensation and azimuth reference functions, and an azimuth reference multiplier for correlation of the SAR data. Following the transversal filter is a block-pipelined inverse FFT used to restore azimuth correlated data in the frequency domain to the time domain for imaging.

Wu, C.↗

Data compression properties of the Hartley transform

The data compression performance of the Hartley transform on a Markov-1 signal is theoretically compared to that of the Fourier transform. Covariance distribution and residue correlation measurements have been computed for the Hartley, Fourier, and cosine transforms. The Hartley transform achieves better coding performance than the Fourier transform, but is inferior to the cosine transform.

Yeh, Pen-Shu↗

Comparison of the Chemical Composition of Liquids from the Pyrolysis and Hydrothermal Liquefaction of Lignocellulosic Materials

Major differences in thermal stability and hydrotreatment behavior of HTL and pyrolysis oils have been reported in the literature. However, little is known about the variations in the chemical composition of these oils that could explain such differences. Two commercial wood pyrolysis oils (Pyrovac and BTG), and their water-soluble (WS) and water-insoluble fractions (WIS) were analyzed and compared with the aqueous (WS WD-57 ) and oily (WIS WS-57 ) fractions obtained from hydrothermal liquefaction (HTL) of Douglas-fir. The samples were characterized by GC/MS, Karl Fischer titration, carbonyl content, total acid number, elemental composition, calorific value, proximate analysis, Fourier Transform Infrared Spectroscopy (FTIR), Folin-Ciocalteu (FC), and UV fluorescence. All the fractions were also analyzed by Fourier Transform Ion Cyclotron Resonance Mass Spectroscopy (FT-ICR-MS) and by Electrospray Ionization (EI). The most prevalent class of compounds in the water insoluble phases were phenols derived from lignin. Water-soluble phases contain mostly the oxygenated compounds derived from cellulose and hemicellulose and were richer in carbonyl functional groups. The water content of the resulting aqueous phases were between: 65 (WS BTG ) and 96 (WS Pyrovac ) wt. %. The bio-oil from BTG has higher water content and lower HHV, compared to Pyrovac oil. The GC/MS results of BTG oil show the presence of a more prominent acetic acid peak and higher TAN number than the Pyrovac oil. The GC/MS of Pyrovac oil showed more obvious mono-phenol peaks. The quantification of this family by Folin-Ciocalteu method confirmed higher content of monophenolic compounds compared with the BTG oil. The lower thermal stability of pyrolysis oils compared with HTL biocrudes can be partially explained by the fact that pyrolysis oils (BTG and Pyrovac) contain carbohydrates while HTL biocrude (WIS WD-57 ) doesn’t. Thus, we decided to further investigate the chemical differences between the phenolic rich fractions insoluble in water and the holocellulose derived compounds soluble in water. Even after water extraction, the acid content of the water insoluble fraction from BTG (WISBTG) was higher than the acid content of the water insoluble fraction obtained by HTL (WISWSD-57). Likewise, the acid content of the aqueous phases derived from pyrolysis oils (WS Pyrovac , WS BTG ) was also higher than for the aqueous phase obtained by HTL (WSWSD-57). This result is in part due to the use of bases in the HTL process that neutralizes the acid formed in that process. Moreover, the starting feedstock may also influence the differences between the oils. Although, the UV-Fluorescence spectra, ICR-MS and the EI analyses showed some minor differences in the molecular weight and chemical make-up of the oligomers soluble and insoluble in water from pyrolysis and HTL; the differences observed were not large enough to justify the differences in behavior between these oils reported in the literature. Our results suggest that the differences observed between HTL biocrudes and pyrolysis oils are likely partially due to the presence of holocellulose derived products in the pyrolysis oils and higher acid contents.

09 BIOMASS FUELS↗

Shaped reflector antenna analysis using the Jacobi-Bessel series

A vector radiation integral is derived for an offset shaped reflector illuminated by an arbitrarily located and oriented source. A procedure for expressing the integral in terms of a series of the Fourier transforms of an effective aperture distribution is discussed. The Jacobi-Bessel series is used to evaluate the Fourier transforms. Numerical results are presented for different reflector configurations and source locations.

Rahmat-Samii, Y.↗

Fast and noise-tolerant determination of the center of rotation in tomography

High-quality tomographic reconstruction is not possible without the accurate localization of the center of rotation. Poor localization leads to artifacts in the data and can even cause reconstructions to fail. There are many approaches to solving this problem, some of which involve the collection of full sinograms, or even provisional tomographic reconstructions, in order to determine the center of rotation. Here, a simple method based on the expected symmetry of the Fourier transform of summed projections approximately 180° apart is presented; unlike cross-correlation methods, it requires only a single Fourier transform to compute, and uses mainly low spatial frequency information which is less susceptible to noise. This approach is shown to be fast, and robust against poor signal-to-noise as well as to projection images acquired at angles that are not exactly 180° apart. This rapid method can be useful as a first step in the processing of tomographic data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SAR processing based on the exact two-dimensional transfer function

The two-dimensional transfer functions of several synthetic aperture radar (SAR) focusing algorithms are derived considering the spaceborne SAR environments. The formulation includes the factors of the earth rotation and the antenna squint angles. The resultant transfer functions are explicitly expressed in terms of Doppler centroid frequency and Doppler frequency rate, which can be accurately estimated from the SAR data. Point target simulation results show that the algorithm based on the two-dimensional Fourier transformation outperforms the one-dimensional one for processing data acquired from high squint angles. The two-dimensional Fourier transformation approach appears to be a viable and simple solution for the processor design of future spaceborne SAR systems.

Chang, C. Y.↗

Consistent Pl Analysis of Aqueous Uranium-235 Critical Assemblies

The lethargy-dependent equations of the consistent Pl approximation to the Boltzmann transport equation for slowing down neutrons have been used as the basis of an IBM 704 computer program. Some of the effects included are (1) linearly anisotropic center of mass elastic scattering, (2) heavy element inelastic scattering based on the evaporation model of the nucleus, and (3) optional variation of the buckling with lethargy. The microscopic cross-section data developed for this program covered 473 lethargy points from lethargy u = 0 (10 Mev) to u = 19.8 (0.025 ev). The value of the fission neutron age in water calculated here is 26.5 square centimeters; this value is to be compared with the recent experimental value given as 27.86 square centimeters. The Fourier transform of the slowing-down kernel for water to indium resonance energy calculated here compared well with the Fourier transform of the kernel for water as measured by Hill, Roberts, and Fitch. This method of calculation has been applied to uranyl fluoride - water solution critical assemblies. Theoretical results established for both unreflected and fully reflected critical assemblies have been compared with available experimental data. The theoretical buckling curve derived as a function of the hydrogen to uranium-235 atom concentration for an energy-independent extrapolation distance was successful in predicting the critical heights of various unreflected cylindrical assemblies. The critical dimensions of fully water-reflected cylindrical assemblies were reasonably well predicted using the theoretical buckling curve and reflector savings for equivalent spherical assemblies.

Fieno, Daniel↗

Rotational spectroscopy at the Jet Propulsion Laboratory

Environmental monitoring, atmospheric remote sensing and astrophysical studies promoted by NASA require a strong basis of spectroscopic information. The rotational spectroscopy capabilities at NASAs Jet Propulsion Laboratory (JPL) are currently maintained for the measurement of key mission priorities that enable modeling and retrieval of geophysical data from the atmosphere as well as validation of the space-borne instruments in the Earth Observing System, particularly the Microwave Limb Sounder. Rotational spectra are measured using a variety of spectroscopic techniques including pulsed-beam Fourier transform microwave spectroscopy (at CalTech); millimeter wavelength Stark spectroscopy; millimeter, submillimeter and THz FM spectroscopy; laser sideband spectroscopy and Fourier Transform far-infrared spectroscopy. Remote measurements of atmospheric rotational spectra are made using two limb-sounder instruments in the submillimeter and THz. Recent advances in the direct synthesis of THz radiation that enable more efficient laboratory science will be presented. Software for comprehensive and systematic study of different molecular systems is maintained at JPL, the software is freely available via http://spec.jpl.nasa.gov and is used by our group to create and sustain the JPL spectral line catalog also available online.

molecular spectroscopy↗

Optical joint transform correlation on the DMD

Initial experimental investigation of the deformable mirror device (DMD) in a joint optical transform correlation is reported. The inverted cloverleaf version of the DMD, in which form the DMD is phase-mostly but of limited phase range, is used. Binarized joint Fourier transforms were calculated for similar and dissimilar objects and written onto the DMD. Inverse Fourier transform was done in a diffraction order for which the DMD shows phase-mostly modulation. Matched test objects produced sharp correlation, distinct objects did not. Further studies are warranted and they are outlined.

Knopp, Jerome↗

Optical data processing study

An onboard coherent optical data processing system was designed to handle large information content of imagery at high speeds, reduce redundancy in picture transmission, and detect specific image features. Theoretically derived Fourier transform characteristics for simple but representative two dimensional images served as a basis for predicting expected features of actual target images. Fourier transformation and spatial filtering of coherent optical images was accomplished theoretically and in the laboratory. The effect of various parameters such as optical aperature, incidence angles, the transparency assumption, the thin lens approximation on resolution, and performance of the system are predicted and tested.

Pinson, L. J.↗

Propagation Characteristics Of Weakly Guiding Optical Fibers

Report discusses electromagnetic propagation characteristics of weakly guiding optical-fiber structures having complicated shapes with cross-sectional dimensions of order of wavelength. Coupling, power-dividing, and transition dielectric-waveguide structures analyzed. Basic data computed by scalar-wave, fast-Fourier-transform (SW-FFT) technique, based on numerical solution of scalar version of wave equation by forward-marching fast-Fourier-transform method.

Manshadi, Farzin↗

Optical Correlator With Complex Holographic Filter

Experimental real-time optical correlator includes complex-valued holographic filter computed from one of two input scenes. Made more tolerant of errors in patterns to be recognized. Filter function essentially coded hologram computed by Burchhardt's method, in which complex value of each pixel of fast Fourier transform of image represented by three real, nonnegative numbers. In generating optical correlator according to method, phasor of each pixel in Fourier transform represented by intensities in three adjacent pixels.

Chao, Tien-Hsin↗

Analytical Bistatic k Space Images Compared to Experimental Swept Frequency EAR Images

A case study of flat plate scattering images obtained by the analytical bistatic k space and experimental swept frequency ISAR methods is presented. The key advantage of the bistatic k space image is that a single excitation is required, i.e., one frequency I one angle. This means that prediction approaches such as MOM only need to compute one solution at a single frequency. Bistatic image Fourier transform data are obtained by computing the scattered field at various bistatic positions about the body in k space. Experimental image Fourier transform data are obtained from the measured response to a bandwidth of frequencies over a target rotation range.

Shaeffer, John↗

Turbulence excited frequency domain damping measurement and truncation effects

Existing frequency domain modal frequency and damping analysis methods are discussed. The effects of truncation in the Laplace and Fourier transform data analysis methods are described. Methods for eliminating truncation errors from measured damping are presented. Implications of truncation effects in fast Fourier transform analysis are discussed. Limited comparison with test data is presented.

Soovere, J.↗

Experimental clean combustor program: Phase 3: Turbulence measurement addendum

Airflow turbulence parameters were measured in the high pressure, high temperature flow stream leaving the compressor of an operating gas turbine engine. A water cooled hot film turbulence probe was used to determine the turbulence intensity and length scale in the compressor exit flow stream of the CF6-50 engine. Data were obtained only at idle operating conditions. At engine power levels above idle conditions, durability problems and erratic data readings were encountered with the turbulence measurement probes. Turbulence measurements were made at three radial immersions at a point 15.5 cm downstream of the compressor outlet guide vanes in the compressor exit diffuser. The passage height at this point is 5.54 cm. Data reduction was accomplished with a time-data fast Fourier transform (FFT) system. This system finds the power spectral density distribution (PSD) of a large number of data samples using a direct Fourier transform algorithm and finds the autocorrelation parameter for these data by doing an FFT analysis of the PSD curves for a series of time delay intervals.

Taylor, J. R.↗