Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Flow loop”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Kinematics and dynamics of disclination lines in three-dimensional nematics

An exact kinematic law for the motion of disclination lines in nematic liquid crystals as a function of the tensor order parameter Q is derived. Unlike other order parameter fields that become singular at their respective defect cores, the tensor order parameter remains regular. Following earlier experimental and theoretical work, the disclination core is defined to be the line where the uniaxial and biaxial order parameters are equal, or equivalently, where the two largest eigenvalues of Q cross. This allows an exact expression relating the velocity of the line to spatial and temporal derivatives of Q on the line, to be specified by a dynamical model for the evolution of the nematic. By introducing a linear core approximation for Q, analytical results are given for several prototypical configurations, including line interactions and motion, loop annihilation, and the response to external fields and shear flows. Behaviour that follows from topological constraints or defect geometry is highlighted. Finally, the analytic results are shown to be in agreement with three-dimensional numerical calculations based on a singular Maier–Saupe free energy that allows for anisotropic elasticity.

36 MATERIALS SCIENCE↗

Comparative Analysis of Direct and Indirect Cooling of Wide-Bandgap Power Modules and Performance Enhancement of Jet Impingement-Based Direct Substrate Cooling

With the development of high-power and high-torque machines, requirements for high-power density electronics are increasing. Thermal management of such systems requires high heat extraction. Conventional air cooling based heat sinks and cold plate based liquid cooling have their own benefits for various applications but has limitations for high power density applications. The current study explores a jet impingement based direct substrate cooling system that was implemented for a SiC based direct bonded Cu substrate for various power losses. Numerical comparison between jet impingement cooling and conventional horizontal/indirect cooling (pin fin heat sink and genetic algorithm-optimized heat sink) showed that the area weighted average of the heat transfer coefficient (HTC) is high for both horizontal cooling designs, and the local HTC is higher for jet impingement. Design iterations were undertaken to resolve the bottleneck of this cooling system. Increasing the number of nozzles helped to cover more area at the direct bonded Cu bottom plate, which drops the chip temperature considerably. With a constant flow rate, increasing the number of nozzles would decrease local jet velocity, which reduces the heat extraction by jet impingement. This issue can be addressed by reducing the diameter of nozzle but doing so results in a high pressure drop where the design constraint is 2 psi. A flared nozzle design is proposed, which has a higher spreading angle of the jet that increases the flow coverage and reduces the pressure drop of the coolant loop.

Barua, Himel↗

High Penetration Power Electronics Grid: Modeling and Simulation Gap Analysis

Increased penetration of power electronics in the grid is happening through development of high-power drives (like in Type 3 or 4 wind turbines, industrial drives, etc.), high-voltage direct current (HVdc) systems, flexible alternating current transmission systems (FACTS), energy storage systems (ESSs), inverter-based renewables like solar and wind, electric vehicle chargers, and other technologies. Ongoing research and development in new power electronic technologies including, but not limited to, solid-state power substations (SSPS), extreme fast charging (XFC), solid-state transformers, and multi-port power electronics that integrate multiple sources/loads will further increase penetration levels. To ensure stakeholders can integrate high penetration of power electronic technologies safely and reliably requires tools and methods to assess and evaluate their impact on the grid. Objectives: This report surveys, assesses, and analyzes commercially available and open-source tools that can support the assessment and evaluation of power electronics in future grids with high penetration levels. The study includes aspects that range from power flow analysis to dynamics evaluation (including hardware-in-the-loop – HIL testing) for such systems. The challenges and gaps associated with the current generation of toolsets available to assess the technical impact of introducing high penetration of power electronics are reported. The method is summarized in Figure ES-1.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Flavor Fragmentation Function Factorization

A definition of partonic jet flavor that is both theoretically well-defined and experimentally robust would have profound implications for measurements and predictions especially for heavy flavor applications. Recently, a definition of jet flavor was introduced as the net flavor flowing along the direction of the Winner-Take-All axis of a jet which is soft safe to all orders, but not collinear safe. Here, we exploit the lack of collinear safety and propose a factorization theorem of perturbative flavor fragmentation functions that resum collinear divergences and describe the evolution of flavor from the short distance of jet production to the long distance at which hadronization occurs. Collinear flavor evolution is governed by a small modification of the DGLAP equations. We present a detailed all-orders analysis and identify exact relations that must hold amongst the various anomalous dimensions by probability conservation and the existence of fixed points of the renormalization group flow. We explicitly validate the factorization theorem at one-loop order, and demonstrate its consistency at two loops in particular flavor channels. Starting at two-loops, constraints on phase space imposed by flavor measurements potentially allow for non-trivial soft contributions, but we demonstrate that they are scaleless and so explicitly vanish, ensuring that soft particles are summed inclusively and all divergences are exclusively collinear in nature. This factorization theorem opens the door to precision calculations with identified flavor in the infrared.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Refining NEAMS MARVEL Reactor Model Accuracy

This report outlines the progress of Idaho National Laboratory (INL) in improving the fidelity of the multiphysics model of the Microreactor Applications Research Validation and Evaluation (MARVEL) reactor developed in FY24. The multiphysics model firstly developed in FY24 leverages three single-physics models coupled via the MOOSE’s MultiApps and Transfer systems. The first single-physics model, that functions as the driver application, leverages Griffin to model the neutron transport in the core through the discontinuous finite element (DFEM) discrete ordinates solver (SN). The second single-physics model uses BISON to compute the solid temperature in the reactor. Finally, the System Analysis Module (SAM) was used to model the flow of the sodium-potassium eutectic in the primary loop. In this report we detail the following improvement and enhancements: • An updated mesh leveraging the latest feature in the reactor module (see Section 3.1.).

42 - ENGINEERING↗

ISOTHERMAL AIR INGRESS VALIDATION EXPERIMENTS

Idaho National Laboratory carried out air ingress experiments as part of validating computational fluid dynamics (CFD) calculations. An isothermal test loop was designed and set to understand the stratified-flow phenomenon, which is important as the initial air flow into the lower plenum of the very high temperature gas cooled reactor (VHTR) when a large break loss-of-coolant accident occurs. The unique flow characteristics were focused on the VHTR air-ingress accident, in particular, the flow visualization of the stratified flow in the inlet pipe to the vessel lower plenum of the General Atomic’s Gas Turbine-Modular Helium Reactor (GT-MHR). Brine and sucrose were used as heavy fluids, and water was used to represent a light fluid, which mimics a counter current flow due to the density difference between the stimulant fluids. The density ratios were changed between 0.87 and 0.98. This experiment clearly showed that a stratified flow between simulant fluids was established even for very small density differences. The CFD calculations were compared with experimental data. A grid sensitivity study on CFD models was also performed using the Richardson extrapolation and the grid convergence index method for the numerical accuracy of CFD calculations . As a result, the calculated current speed showed very good agreement with the experimental data, indicating that the current CFD methods are suitable for predicting density gradient stratified flow phenomena in the air-ingress accident.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Compatibility of FeCrAlMo with flowing PbLi at 500°-650°C

To explore the upper temperature limit of a fusion blanket utilizing eutectic Pb-17at.%Li for tritium breeding, a series of three mono-metallic thermal convection loops have been fabricated from alloy APMT (Fe–21Cr–5Al–3Mo) and operated with commercial PbLi and increasing peak temperatures of 550°, 600° and 650 °C, flow rates of 0.4–0.7 cm/s and temperature gradients of 85–115 °C. Chains of APMT specimens including 25 mm long tensile specimens were hung in the hot and cold legs of the loops to evaluate post-exposure room temperature tensile properties after 1000 h exposures in each experiment. For specimens exposed to flowing PbLi above 500°C, only minor changes in tensile properties were observed after exposure. Most APMT specimens were pre-oxidized to form alumina prior to exposure and exhibited small mass losses as the alumina was partially transformed to α-LiAlO 2 that tended to spall after exposure. Specimens without pre-oxidation exhibited higher mass losses and formed γ-LiAlO 2 but with less spallation. While promising for increasing blanket temperatures, the small mass losses suggest that the surface oxide is not completely stable. In conclusion, even at the highest temperatures, there was no indication of classic dissolution/precipitation behavior suggesting that higher temperature compatibility may be possible.

36 MATERIALS SCIENCE↗

Scaling Analysis for the Direct Reactor Auxillary Cooling System For AHTRS

The Direct Reactor Auxiliary Cooling System (DRACS) is a passive heat removal system proposed for the Advanced High-Temperature Reactor (AHTR) that combines the coated particle fuel and graphite moderator with a liquid fluoride salt as the coolant. The DRACS features three coupled natural circulation/convection loops relying completely on buoyancy as the driving force. In the DRACS, two heat exchangers, namely, the DRACS Heat Exchanger (DHX) and the Natural Draft Heat Exchanger (NDHX) are used to couple these loops. In addition, a fluidic diode is employed to minimize the parasitic flow during normal operation of the reactor and to activate the DRACS in accidents. While the DRACS concept has been proposed, there are no actual prototypic DRACS systems for AHTRs built and tested in the literature. In this paper, a detailed scaling analysis for the DRACS is performed, which will provide guidance for the design of the scaled-down DRACS test facilities. Based on the Boussinesq assumption and one-dimensional flow formulation, the governing equations are non-dimensionalized by introducing appropriate dimensionless parameters. The key dimensionless numbers that characterize the DRACS system are obtained straightforwardly from the non-dimensional governing equations. Based on the dimensionless numbers and non-dimensional governing equations, similarity laws are proposed. In addition, a scaling methodology has also been developed, which consists of the core scaling and loop scaling. The consistence between the core and loop scaling is examined through the reference volume ratio, which can be obtained from the core and loop scaling processes. The scaling methodology and similarity laws have been applied to obtain a design of the scaled-down high-temperature DRACS test facility (HTDF).

Scaling auxiliary AHTRS DRACS liquid salt molten r↗

On the flow induced vibration of an externally excited nuclear reactor experiment

An in-pile, drop-in experiment design is presently being designed and studied for the near-term deployment within the Advanced Test Reactor (ATR) located at the Idaho National Laboratory (INL); this experiment is termed the Miniplate-1 Large-B (MP-1 LB) Experiment. A number of explicit studies are performed during the design- and safety-related stage. Traditionally, a clear and logical methodology has been developed and utilized for analyses such as hydraulics, thermal-loads, mechanical loads, and others for these experiments. Recently a small component from a different experiment assembly mechanically separated while in the reactor’s core. While this experiment didn’t compromise the safety of the reactor, it led to a higher-level question which centered on whether the appropriate level of consideration was being made toward the fluid–structure-interactions of these experiments. The outcome yielded separate flow test experiments of like-for-like geometry in an experimental loop located at Oregon State University which produces experimental data compliant with applicable parts and requirements to ASME’s NQA-1 2008, 2009a standard – suitable for benchmark evaluation. Here, the objectives of this study are to (1) develop a process for handling and interpreting the mechanical response of the test elements during hydraulic testing, to (2) characterize the motion of a specific test element during a flow test which imposes a wide range of hydraulic conditions, and (3) provide objective observations toward the potential safety related implications that are tied to the synthesized data. The outcome of this study has led to a confident process in inspecting the experimental data, synthesized it for interpretation, identified several unique hydraulic characteristics of the experiment design which were previously unknown, and demonstrated that the likelihood for mechanical failure resulting from fluid-structure-interactions in the reactor is far below any criterion for concern of the element’s safety.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Development of a Testbed for Pipeline Flushing - 20425

Pipelines which carry high-level waste within the DOE complex should be properly flushed in the cases where stationary or moving beds of solid sediment occur, or lines are prone to hydrogen gas buildup. Present guidelines establish a minimum for the amount of water (flush volume) and flush velocity values used for post-transfer flushing operations to achieve satisfactory cleaning of pipelines. However, further studies are needed to find optimal operating velocity modes/values in order to minimizing the flush volume and consequent downstream waste. These efforts are significantly helpful to DOE waste remediation sites by preserving tank storage, preventing additional waste processing, and minimizing dilution and changes in waste chemistry. An experimental test loop was recently developed for study of non-Newtonian slurry flushing at the Florida International University (FIU). This loop was designed to create sediment beds of various materials and bed heights and investigate parameters that effect the efficiency of flushing operations. The objective is to find flush velocity values/modes which lead to satisfactory cleaning of transport lines with a minimum amount of water usage. A 165 ft experimental test loop made of 3-inch carbon steel pipes was constructed and used in initial testing campaigns. This pipe loop was equipped with real-time monitoring instruments to record variation of pressure, density, mass flow rate, and temperature during testing. Post-flush in-situ no-flow evaluations were performed using ultrasonic, endoscopy, and visual inspection. Additional post-flush evaluations were conducted using filtration and density monitoring of residuals within a designated circulations loop. These provisions enable comparison of pipeline cleanness before the start and after termination of flushing operations for efficiency evaluation. This paper presents efforts associated with flushing of kaolin-water mixtures at different concentrations and with various flush volume and flush velocity values/modes. In initial testing, efforts focused on creating repeatable sediment beds inside the pipeline in both fully-flooded (no pre-flush drainage) and gravity-drained (pre-flush drained) systems. Bed characterization (i.e., measurement of sediment height and solids concentration) was conducted to ensure about consistency of initial conditions between tests. Preliminary results for flushing study of 10% vol. kaolin-water mixtures starting from a fully-flooded initial condition showed that flushing with 1-line volume (65 gallons) could remove up to 72 percent of solids from the pipeline. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

ESTIMATING THE DEEP SOLAR MERIDIONAL CIRCULATION USING MAGNETIC OBSERVATIONS AND A DYNAMO MODEL: A VARIATIONAL APPROACH

We show how magnetic observations of the Sun can be used in conjunction with an axisymmetric flux-transport solar dynamo model in order to estimate the large-scale meridional circulation throughout the convection zone. Our innovative approach rests on variational data assimilation, whereby the distance between predictions and observations (measured by an objective function) is iteratively minimized by means of an optimization algorithm seeking the meridional flow that best accounts for the data. The minimization is performed using a quasi-Newton technique, which requires knowledge of the sensitivity of the objective function to the meridional flow. That sensitivity is efficiently computed via the integration of the adjoint flux-transport dynamo model. Closed-loop (also known as twin) experiments using synthetic data demonstrate the validity and accuracy of this technique for a variety of meridional flow configurations, ranging from unicellular and equatorially symmetric to multicellular and equatorially asymmetric. In this well-controlled synthetic context, we perform a systematic study of the behavior of our variational approach under different observational configurations by varying their spatial density, temporal density, and noise level, as well as the width of the assimilation window. We find that the method is remarkably robust, leading in most cases to a recovery of the true meridional flow to within better than 1%. These encouraging results are a first step toward using this technique to (i) better constrain the physical processes occurring inside the Sun and (ii) better predict solar activity on decadal timescales.

79 ASTRONOMY AND ASTROPHYSICS↗

Shielding Design for Prototype Generation-IV Sodium-Cooled Fast Reactor

A Prototype Generation-IV Sodium-cooled Fast Reactor (PGSFR) with 150 MWe power rating is being developed jointly by the Korea Atomic Energy Research Institute (KAERI) and Argonne National Laboratory (ANL). KAERI is responsible for the overall project with the ANL contributions integrated into the KAERI activities. Shielding concept of PGSFR was developed to ensure that the safety limit on internal structural damage and working personnel received dose is not exceeded. The first part evaluated the Displacement Per Atoms (DPA) and fast neutron fluence on the structures inside the reactor vessel, such as lower grid, Upper Internal Structure (UIS), barrel, Redan, and reactor vessels. The analysis determined the thickness of shields required to satisfy the DPA and fast fluence limit. The second part of the shielding analysis evaluated the radiation dose rate above the reactor head due to the primary sodium activation inside the reactor vessel. The analysis determined the necessary thickness of reactor head and additional shield to ensure that the dose rate received by personnel working on top of the reactor is below the safety limit. The last part of the shielding analysis investigated the dose rate received by personnel working near the secondary loop. The secondary sodium is activated inside the Intermediate heat exchanger (IHX). The activated secondary sodium flows out of the reactor vessel and emits high energy photons along the way. The shielding designs both inside the reactor vessel and around the pipes of the secondary loop were investigated. The shielding concept for the PGSFR was developed to minimize radiation exposure to plant personnel and the irradiation damage of the internal structural components. The damage of the internal structural components are mainly due to the loss of the ductility by the neutron irradiation, and the activated gammas of primary and secondary sodium coolants are the major radiation sources that are required to be shielded. Thicker and denser shielding structures are favorable to reduce the radiation dose and protect personnel who work in the plant; however, which enlarges the in-vessel space to accommodate the shielding structures. Thus, in order to install the shielding structures in a reasonable reactor to satisfy the DPA or dose rate limit size, the PGSFR shielding parameters were determined from the sensitivity study, which includes the compositions of the shielding materials and dimensions. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Development of a Test-Bed for Testing and Refining EarthEn’s Supercritical CO 2 Based Energy Storage System

EarthEn’s energy storage concept leverages supercritical carbon dioxide (sCO 2 ) as a working fluid and relies on compact, high-performance components operating at elevated pressures and temperatures. To accelerate component development and reduce technical risk prior to larger-scale demonstrations, Oak Ridge National Laboratory (ORNL) developed a 100 kW-scale sCO 2 test-bed under a Cooperative Research and Development Agreement with EarthEn (CRADA NO. NFE-24-10050). The objective of the work was to design and construct a flexible experimental facility capable of reproducing key thermodynamic state points and heat-transfer conditions relevant to EarthEn’s thermal energy storage (TES) cycle, with particular emphasis on enabling development and evaluation of next-generation heat exchangers and TES concepts. The test-bed consists of a closed-loop sCO 2 circulation system housed within an open-topped enclosure. In its as-installed configuration, dense-phase sCO 2 is recirculated through a printed circuit recuperator, an electrically heated section, a throttling device used to simulate turbine expansion, and a water-cooled printed circuit heat exchanger that rejects heat to the building chilled-water system before returning to the pump. The pump is driven by a variable frequency drive, enabling controlled adjustment of flow and operating point. A comprehensive instrumentation suite was integrated to support both safe operation and high-quality data collection. Installed sensors include Coriolis flow meters for sCO 2 flow rate and density, resistance temperature detectors and thermocouples distributed throughout the loop (including the heated section and key heat exchanger ports), and pressure transducers for absolute and differential pressure measurements. The facility was designed to support high-pressure (19 MPa nominal) and high-temperature (575°C nominal) operation with credited overpressure protection provided by a rupture disk. Nominal operating conditions were selected to support 100 kW-class testing while maintaining flexibility for non-heated and heated shakedown, control development, and future integration of advanced TES test sections. In parallel with facility development, a system-level thermal-hydraulic model was created using Modelica-based tools to support component sizing, anticipate performance over targeted test conditions, and establish a framework for future model calibration against experimental data. At the conclusion of the project performance period, the facility was in final assembly, and the pressure boundary was nearly completed. However, several practical challenges associated with high-pressure/high-temperature systems and specialized component procurement impacted schedule and prevented initial pump-driven operation and full commissioning within the available resources. This report documents the as-built design, operating capabilities, and instrumentation, and it summarizes key lessons learned related to heater fabrication and testing, first-of-a-kind assembly factors, specialty flange supply constraints, and fill pump corrective actions. Finally, it outlines a phased plan for future commissioning and experimental campaigns, including control and instrumentation shakedown, heater characterization, model calibration, and testing at state points representative of EarthEn’s TES cycle.

25 ENERGY STORAGE↗

Heating and dynamics of two flare loop systems observed by AIA and EIS

We investigate heating and evolution of flare loops in a C4.7 two-ribbon flare on 2011 February 13. From Solar Dynamics Observatory/Atmospheric Imaging Assembly (AIA) imaging observations, we can identify two sets of loops. Hinode/EUV Imaging Spectrometer (EIS) spectroscopic observations reveal blueshifts at the feet of both sets of loops. The evolution and dynamics of the two sets are quite different. The first set of loops exhibits blueshifts for about 25 minutes followed by redshifts, while the second set shows stronger blueshifts, which are maintained for about one hour. The UV 1600 observation by AIA also shows that the feet of the second set of loops brighten twice. These suggest that continuous heating may be present in the second set of loops. We use spatially resolved UV light curves to infer heating rates in the few tens of individual loops comprising the two loop systems. With these heating rates, we then compute plasma evolution in these loops with the 'enthalpy-based thermal evolution of loops' model. The results show that, for the first set of loops, the synthetic EUV light curves from the model compare favorably with the observed light curves in six AIA channels and eight EIS spectral lines, and the computed mean enthalpy flow velocities also agree with the Doppler shift measurements by EIS. For the second set of loops modeled with twice-heating, there are some discrepancies between modeled and observed EUV light curves in low-temperature bands, and the model does not fully produce the prolonged blueshift signatures as observed. We discuss possible causes for the discrepancies.

79 ASTRONOMY AND ASTROPHYSICS↗

Toward reducing uncertainty quantification costs in DEM models of particulate flow: Testing simple, sensitivity-based, forward uncertainty propagation techniques

The performance of two conceptually-simple uncertainty quantification techniques are tested against the rigorous nested-loop sampling technique of Roy and Oberkampf (Comput Methods Appl Mech Eng, 200: 2131–2144, 2011) (herein called full-sampling) using two very small-scale DEM-based models of particulate flow (one gas-solid flow and one granular flow). The first simplified forward uncertainty propagation technique, reduced-sampling, uses a sensitivity analysis to eliminate uncertain inputs that have little impact on the model output prior to nested-loop sampling. The second technique, boundary-sampling, uses a sensitivity analysis to inform the selection of two bounding cases for each key model output. In conclusion, the uncertainties in the model outputs obtained via the reduced- and boundary-sampling methods agree well with those from full-sampling for both the gas-solid and granular flow models while yielding computational savings of 65–75% (reduced sampling) and 94–97% (boundary sampling).

42 ENGINEERING↗

Pilot Scale Operation and Testing of Syngas Chemical Looping For Hydrogen Production

The Syngas Chemical looping (SCL) process provides efficient and economic means to utilize the abundant fossil reserve of coal. The main problem associated with coal utilization is the CO 2 emissions resulting from its combustion. Even though CO 2 regulation or carbon tax is currently not in place, its enforcement is expected in the near future. Such a greenhouse gas emission control, if adopted in current power plant systems, will drive the efficiency down and increase the cost of electricity, due to the energy and capital-intensive nature of current CO 2 separation techniques. This highlights the need to develop technologies that present a solution to the rising cost of electricity in the future. The integrated gasification combined cycle (IGCC) presents an improvement to the above predicament, but it is capital intensive due to the extensive unit operations involved. The efficiency for a CO 2 capture incorporated IGCC system is around ~32%, resulting in approximately 45% increase in cost of electricity. This is definitely a better path to traverse than the conventional pulverized coal (PC) power plants as it has improved economics and efficiencies accompanied by product flexibility. The SCL process advances the benefits even further when integrated with the IGCC process. The SCL process removes the expensive WGS system and CO 2 separation columns, thereby saving on capital and operational expenses. This integration results in a 12 – 21% increase in efficiency accompanied by a reduction in cost of electricity by 15 – 28%, over conventional IGCC systems. Therefore, SCL process provides the best route to harness the energy from coal. The overall project objective was to construct and operate a syngas chemical looping pilot scale test unit at the NCCC. The project scope of work was divided into 3 phases. In Phase I, cold flow model studies using a 1:1 scale acrylic test unit constructed at Particulate Solids Research, Inc. (PSRI) was successfully completed confirming robust solid flow control is achievable in the non-mechanical system design. In Phase II, the high pressure, high temperature, chemical looping reactor was successfully designed with all necessary equipment and safety instrumentation/controls specified to allow for fabrication, site construction, and assembly to commence in Phase III. In Phase III, the SCL pilot plant was successfully assembled and all necessary functional checks and pre-startup safety reviews completed. During unit commission over the course of 200 hours of testing, operational issues were observed with premix burner used for system startup. With the grants awarded by the National Energy Laboratory (NETL) and the Ohio Development Services Agency (ODSA) under awards DE-FE0023915 and D-14-18, the SCL pilot unit underwent three auxiliary equipment modifications to resolve all of the startup operational issues encountered. The unit was successfully demonstrated with 300+hr continuous operation. Key results obtained include high syngas conversion of 97.95% with 16.03% oxygen carrier conversion in the moving bed reducer and >99% purity H 2 produced from the moving bed oxidizer.

01 COAL, LIGNITE, AND PEAT↗

Closed-Loop Wind Turbine Controllers for Active Wake Mixing Strategies

Wind turbine active wake mixing (AWM) is an exciting new field of research where dynamic actuation, usually on the blade pitch angles, is used to increase wind farm-wide power production. From a controls perspective, the current state-of-the-art AWM strategies are very simple: a dynamic, usually periodic, reference signal is prescribed to actuators in an open-loop (OL) fashion. The actuation is then presumed to have a certain desired effect on the system, i.e., the wind turbine and the flow it affects. However, this system is highly nonlinear and experiences disturbances in the form of wind variations that are not known a priori. As a result, the OL approach might not yield optimal results. In this article, a novel approach is presented, which closes the loop on AWM controllers. A feedback loop is implemented, which uses measurements of the individual blade bending moments that are widely available on modern wind turbines to determine the individual blade pitch angles. A proof of concept of this implementation is presented in this article, and a thorough comparison with the OL method is executed using high-fidelity flow simulations. These simulations show that the novel closed-loop controller does not substantially increase wake mixing but achieves similar performance as the OL controller while reducing fatigue loads on the controlled turbine.

17 WIND ENERGY↗

Flexible AI Models for Grid Resilience

The rapid growth in size and complexity of artificial intelligence (AI) and machine learning (ML) models has led to increased energy demands, posing a threat to the reliability of the existing power grid. This project addresses the challenge of highly intermittent and energy-intensive inference workloads by (1) developing fidelity-adaptive neural networks capable of dynamic response to grid conditions and (2) integrating these networks with power flow simulations to assess their impact on power grid reliability. We will explore both top-down and bottom-up approaches to create hierarchies of submodels that provide a controlled trade-off between power draw and prediction accuracy. The top-down method utilizes NN pruning to reduce a flagship model into progressively smaller, energy-efficient variants. The bottom-up approach employs geometrically principled weight setting strategies to construct depth-efficient models from the ground up. A real-time hardware-in-the-loop (HIL) platform will be developed to simulate a scaled AC power grid, integrating live AI workload power draw and enabling dynamic model switching in response to grid feedback. This work will provide a novel framework for evaluating the impact of flexible AI/ML workloads on grid performance and establish new methodologies for energy-aware computing in data centers. The outcomes will demonstrate that adaptive AI/ML can play a critical role in improving grid stability while advancing NREL's leadership in energy-efficient computing research.

24 POWER TRANSMISSION AND DISTRIBUTION↗