Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “File System”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Examining the Impact of Data Layout on Tape on Data Recall Performance for ATLAS

Increases in data volumes are forcing high-energy and nuclear physics experiments to store more frequently accessed data on tape. Extracting the maximum performance from tape drives is critical to make this viable from a data availability and system cost standpoint. The nature of data ingest and retrieval in an experimental physics environment make achieving high access performance difficult given the inherent limitations of magnetic tape. Tailoring the layout of data on tape is one key to improving read performance. This paper highlights the work in progress to characterize ATLAS data ingested in the tape system, understand how data layout, i.e. file co-location on tape and file distribution over tapes, affect read performance and how optimal data layout might be achieved in a production environment.

99 GENERAL AND MISCELLANEOUS↗

SU-E-T-141: Automated Dose Point Placement for Cervical Cancer Brachytherapy Using Tandem and Ovoid Applicators

Purpose: To develop a standalone application, which automatically and consistently calculates the coordinates of points A and H based solely on the implanted applicator geometry for cervical cancer HDR brachytherapy. Methods: Manchester point A and ABS point H are both located 2cm lateral from the central tandem plane. While both points are located 2cm above the cervical os, surrogates for the os differ. Point A is defined relative to the anatomical cervical os. Point H is defined relative to the intersection of the tandem with the superior aspects of the ovoids. The application takes an input text file generated by the treatment planning system (TPS, BrachyVision, Varian) that specifies the source geometries. It then outputs the 3D coordinates of points A and H in both the left and right directions. The algorithm was implemented and tested on 34 CT scans of 7 patients treated with HDR brachytherapy delivered using tandem and ovoids. A single experienced user retrospectively and manually placed points A and H on the CT scans, whose coordinates were used as the gold standard for the comparison to the automatically calculated points. Results: The automatically calculated coordinates of points A and H agree within 0.7mm with the gold standard. The averages and standard deviations of the 3D coordinate difference between points placed by the two methods are 0.3±0.1 and 0.4±0.1mm for points A and H, respectively. The maximum difference in 3D magnitude is 0.7mm. Conclusion: The algorithm consistently calculates dose point coordinates independently of the planner for cervical cancer brachytherapy treated with tandem and ovoids. Automated point placement based on the geometry of the implanted applicators agrees in sub-millimeter with careful manual placements by an experienced user. This algorithm expedites the planning process and eliminates dependencies on either user input or TPS visualization tools.

60 APPLIED LIFE SCIENCES↗

SU-F-BRB-07: A Plan Comparison Tool to Ensure Robustness and Deliverability in Online-Adaptive Radiotherapy

Purpose: To develop a plan comparison tool that will ensure robustness and deliverability through analysis of baseline and online-adaptive radiotherapy plans using similarity metrics. Methods: The ViewRay MRIdian treatment planning system allows export of a plan file that contains plan and delivery information. A software tool was developed to read and compare two plans, providing information and metrics to assess their similarity. In addition to performing direct comparisons (e.g. demographics, ROI volumes, number of segments, total beam-on time), the tool computes and presents histograms of derived metrics (e.g. step-and-shoot segment field sizes, segment average leaf gaps). Such metrics were investigated for their ability to predict that an online-adapted plan reasonably similar to a baseline plan where deliverability has already been established. Results: In the realm of online-adaptive planning, comparing ROI volumes offers a sanity check to verify observations found during contouring. Beyond ROI analysis, it has been found that simply editing contours and re-optimizing to adapt treatment can produce a delivery that is substantially different than the baseline plan (e.g. number of segments increased by 31%), with no changes in optimization parameters and only minor changes in anatomy. Currently the tool can quickly identify large omissions or deviations from baseline expectations. As our online-adaptive patient population increases, we will continue to develop and refine quantitative acceptance criteria for adapted plans and relate them historical delivery QA measurements. Conclusion: The plan comparison tool is in clinical use and reports a wide range of comparison metrics, illustrating key differences between two plans. This independent check is accomplished in seconds and can be performed in parallel to other tasks in the online-adaptive workflow. Current use prevents large planning or delivery errors from occurring, and ongoing refinements will lead to increased assurance of plan quality.

60 APPLIED LIFE SCIENCES↗

Generic Data Display (GD2)

SAND2023-11967O Generic Data Display (GD2) is a real-time data visualization application that can display user-defined input data. The open-source software is comprised of a back end system written in Python, and a front end user interface written in JavaScript. The back end system collects data from a variety of input sources, such as message queue, HTTP, XML, JSON, and others. The front end displays data in an Open MCT web interface, and users can configure the system by providing JSON formatted configuration files. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Figueroa, Benjamin↗

DetermineSystem

SAND2025-04092O DetermineSystem, an open-source utility library, determines the system name from a given supported_systems.ini file, the machine’s hostname, and the “give build” name. The library is part of the GenConfig family of modules. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Braun, Joshua↗

Fallon FORGE: Well Temperature Data

x,y,z downhole temperature data for wells in and around the Fallon FORGE site. Data for the following wells are included: 82-36, 82-19, 84.31, 61-36, 88-24, FOH-3D, FDU-1, and FDU-2. Data are formatted in txt format and in columns for importing into Earthvision Software. Column headers and coordinate system information is stored in the file header.

15 GEOTHERMAL ENERGY↗

HERO WEC Belt Test Data

The following submission includes raw and processed data from the 2024 Hydraulic and Electric Reverse Osmosis Wave Energy Converter (HERO WEC) belt tests conducted using NREL's Large Amplitude Motion Platform (LAMP). A description of the motion profiles run during testing can be found in the run log document. Data was collected using NREL's Modular Ocean Data AcQuisition (MODAQ) system in the form of TDMS files. Data was then processed using Python and MATLAB and converted to MATLAB workspace, parquet, and csv file formats. During Data processing, a low pass filter was applied to each array and the arrays were then resampled to common 10Hz timestamps. A MATLAB data viewer script is provided to quickly visualize these data sets. The following arrays are contained in each test data file: - Time: Unix seconds timestamp - Test_Time: Time in seconds since beginning of test - POS_OS_1001: Encoder position in degrees (the encoder is located on the secondary shaft of the spring return and is driven by the winch after a 4.5:1 gear reduction) - LC_ST_1001: Anchor load cell data in lbf - PRESS_OS_2002: Air spring pressure in psi This data set has been developed by the National Renewable Energy Laboratory, operated by Alliance for Sustainable Energy, LLC, for the U.S. Department of Energy (DOE) under Contract No. DE-AC36-08GO28308. Funding provided by the U.S. Department of Energy Office of Energy Efficiency and Renewable Energy Water Power Technologies Office.

16 TIDAL AND WAVE POWER↗

Technical Report for Water Circulation Pumping System for Trihalomethanes (THMs)

The TSWWS was added as an active source of supply to the permit (No. 03-10-13P-003) in 2010, but has never been used due to the potential for formation of trihalomethanes (THMs) in the distribution system. THMs are formed as a by-product when chlorine is used to disinfect water for drinking. THMs are a group of chemicals generally referred to as disinfection by-products (DBPs). THMs result from the reaction of chlorine with organic matter that is present in the water. Some of the THMs are volatile and may easily vaporize into the air. This fact forms the basis of the design of the system discussed in this technical report. In addition, the design is based on the results of a study that has shown success using aeration as a means to reduce TTHMs to within allowable concentration levels with turn-over times as long as ten days. The Primary Drinking Water Standards of Regulated Contaminants Maximum Contaminant Level (MCL) for TTHMs is 80 parts per billion (ppb). No other changes to the existing drinking water distribution system and chlorination operations are anticipated before switching to the TSWWS as the primary drinking water source. The two groundwater wells (Wells 20 and 18) which are currently the primary and backup water sources for the system would be maintained for use as backup supply. In the future, one of the wells may be removed from the system. A permit amendment would be filed at that time if this modification was deemed appropriate.

54 ENVIRONMENTAL SCIENCES↗

A Section 106 Evaluation of Building CP-1, Area 6, Nevada National Security Site, Nye County, Nevada

On December 17, 2015, the National Nuclear Security Administration Nevada Field Office (NNSA/NFO) vacated Building CP-1 (Building 06-CP-1) on the Nevada National Security Site (NNSS) in Nye County, Nevada. Starting in 1951, nearly all nuclear tests during the Cold War were controlled from this building on the facility, known as the Nevada Test Site for most of its years of operation. The test site was renamed the NNSS in 2010. CP-1 was the command and control center where decisions about NNSS activities were sought and made; where authorization for movements about the areas forward (north) of Mercury base camp were coordinated, granted or declined, and monitored; and where problems and emergencies in the forward areas were communicated and relayed to the appropriate agencies for solution. Some of the testing duties for the Control Point included the timing and firing of nuclear tests, air operations, security, communications, weather monitoring, and radiation safety. During tests, communications were maintained through various channels to receive and pass instructions or information to the numerous testing operations, to Washington, D.C., the national laboratories, and overhead aircraft monitoring the tests. At one time, the Security Control Center, a Class A Weather Station, and the Radiation Safety Headquarters were located in CP-1, which also contained a cafeteria, a dining area, and bunk rooms. This survey was prompted by recognition that closure of the building in place creates a situation where CP-1 is vulnerable to decay in its present and unused condition. Activities at CP-1 have been reduced gradually over time since the end of nuclear testing in 1992. The Area of Potential Effects (APE) was determined by NNSA/NFO to be a two-acre area historically considered the space directly associated with CP-1 and available to CP-1 personnel for use. The APE is bounded on the south by an unnamed main paved road into the guarded Control Point area, on the west by the edge of the parking lot for adjacent Building CP-9, on the east by the edge of the bladed cut-and-fill terrace for CP-1, and on the north by a barbed wire security fence (Figure 2). All of this lot is either bladed or covered with asphalt. Contained within the lot are eight Accessary Resources (AR) which are much more closely aligned with CP-1 than with adjacent buildings. AR are defined by the Nevada State Historic Preservation Office (SHPO) (2013) as “…related but subordinate to the principal building. Accessory resources would not exist were it not for the principal resource.” The Visual APE was determined by NNSA/NFO to be the same as the APE used for intensive survey because no exterior modifications to the resource are anticipated. The APE is located in Section 34 T11S R53E MDBM (projected) within the NNSS base called the Control Point in Area 6. It is on the 1986 Yucca Lake USGS 7.5 min. series topographic quadrangle. The Desert Research Institute (DRI) surveyed the APE with the assistance of National Security Technologies, LLC (NSTec), resulting in recordation and evaluation of CP-1 (SHPO Resource Number B14490) and eight accessory resources (AR1-AR8). This recording of CP-1 was done in three sessions. Copies of the building form and report are on file at Nevada Cultural Resources Information System (NVCRIS), DRI, and with the NNSA/NFO, Las Vegas, Nevada. Control Point refers to the support facilities of which Building CP-1, with its 126 rooms, is the most important part (Campbell et al. 1983:165). CP-1 refers to the entire building but it also is the designation for the first phase of construction, i.e. the original building. There were three major subsequent phases of additions to the building. The first two were called CP-1A (the east wing) and CP-1B (the west wing with the new War Room). A final phase filled in the hyphen between CP-1 and CP-1B with a Field Office. For convenience this last phase is called CP-1C in this report. Hence, CP-1 can refer either the entire building or to the first phase of the building exclusive of additions. The context makes clear which of the two meanings is intended in the various sections of this report. There were also two minor expansions consisting of a small battery room and a shelter for an emergency exit.

54 ENVIRONMENTAL SCIENCES↗

Improvements to MOOSE user workflow through polyhedral elements, automation, and concise physics syntax

The MOOSE framework is a foundational capability used by the NEAMS program to create over 15 different simulation tools for advanced nuclear reactors. Due to MOOSE's broad use, improvements to the framework in support of modeling and simulation goals are critical to the program. Such improvements can take many forms, including optimization, improved user experience, streamlined application programming interfaces (APIs), parallelism, and new capabilities. The work described in this report was conducted in direct support of NEAMS tools and includes: addition of support for polyhedral elements, incorporation of mesh smoothers for mesh repair, integration of the Physics and ActionComponents systems, expansion of the Convergence system, and exploration of automated input file generation. These five areas of development are fundamental capabilities that will be leveraged by many NEAMS applications.

97 - MATHEMATICS AND COMPUTING↗

Lidar - Massachusetts - Leosphere Windcube 866 (120) - Raw Data

These are the data collected during the validation period. The buoy is scheduled to be deployed near Martha's Vinyard in mid-January 2020. The Leosphere Windcube 866 lidar systems output 5 different compressed data files. Compression is explained below.

17 WIND ENERGY↗

Lidar - Massachusetts - Leosphere Windcube 866 (130) - Raw Data

These are the data collected during the validation period. The buoy is scheduled to be deployed near Martha's Vinyard in mid-January 2020. The Leosphere Windcube 866 lidar systems output 5 different compressed data files. Compression is explained below.

17 WIND ENERGY↗

Farm Practice Typologies as a Strategy for Management-Relevant Land Use and Land Cover Mapping in the Great Lakes Region (Version 1) [Dataset]

Dataset overview and development This dataset provides spatially explicit agricultural land-use and land-management typologies developed for the Great Lakes Region (GLR) at the farm-parcel level. The typologies were designed to characterize not only the land-use and land-cover (LULC) associated with individual agricultural farm parcels, but also the land-management practices (LMPs), including irrigation, tile drainage, and conservation easements, occurring within those parcels and how these characteristics change through time. The dataset contains four related typology products: Annual integrated typology – describes the combined LULC and land-management characteristics for each farm parcel for individual years. LULC transition typology – describes the temporal pattern of LULC change for each farm parcel across the study period (2008-2023). LMP trend typology – describes the temporal pattern in the occurrence of LMPs for each farm parcel across the study period. Multi-year integrated typology – combines the LULC transition typology and LMP trend typology to provide an integrated characterization of long-term land-use and management patterns. Purpose of the dataset The purpose of these products is to provide a management-relevant integrated and consistent framework for evaluating the spatial and temporal organization of agricultural landscapes across the GLR. The resulting typologies can: support landscape-scale environmental and land-use analysis; provide spatial information relevant to land-management strategies, conservation planning, policy development, and program evaluation; characterize spatial patterns of agricultural land use and management; examine changes in agricultural landscapes through time; and identify persistent, transitional, and changing agricultural systems. Please refer to the README file provided in Files for more details.

Agriculture↗

Super Strypi HWIL 6DOF (Hardware-In-Loop six-degree-of-freedom) Rev. 2175

The Super Strypi HWIL is a six degree-of-freedom (6DOF) simulation for the Super Strypi Launch Vehicle. The simulation is used to test the NGC flight software including the navigation software. Aerodynamic and propulsive forces, mass properties, ACS (attitude control system) parameters are defined in input files. Output parameters are saved to a Matlab mat file.

Gilkey, Jeff C.↗

Image processing tool for automatic feature recognition and quantification

A system for defining structures within an image is described. The system includes reading of an input file, preprocessing the input file while preserving metadata such as scale information and then detecting features of the input file. In one version the detection first uses an edge detector followed by identification of features using a Hough transform. The output of the process is identified elements within the image.

36 MATERIALS SCIENCE↗

Why accredit ISO/CEI 17025 a nuclear waste management laboratory? - 15112

When there is no storage, nor repository, available on a site, the entity in charge of nuclear waste management should find outlets in order to evacuate outside the site. Each outlet has his rules and waste acceptance criteria (packaging rules, physical/chemical/radiological criteria for example). Before you are able to evacuate your waste, an acceptance's process (or contract review) takes place. This process scans the entire measures implemented by the site in order to satisfy outlet's criteria. When the acceptance is obtained, shipments could be organized, and the process gets into an observation's phase. During this phase, the outlet could choose to inspect a finished nuclear waste package or to audit regularly the waste management process. In this last case, the outlet re-scans the entire documents and implemented measures. This audit lasts from one to several days. A way to tackle/approach the audit is to acknowledge, by a trusted third party (i.e. independent from the outlet), all or part of waste management system, in order to base one's reputation on this organism and win outlet's trust. For this purpose, the entity could choose certification or accreditation. Certification (ISO 9001 as often as not) aims at evaluating a system for managing the quality of one product or service. Accreditation (ISO 17025, for example) provides formal recognition for technical skills within a quality management system (clauses 5 and 4 of the ISO 17025 standard). In 2006, the LDM laboratory is the first French laboratory accredited, in accordance with ISO 17025 standard, for the characterization by gamma spectrometry on 100 L- and 200 L- radioactive waste drums (accreditation No 1-1712 - scope available on www.cofrac.fr). This accreditation allows the lab: - to update the quality management system, - to compile the entire technical file of the gamma-ray assay (description, evaluation of the uncertainties, calibration, proficiency testing programs, measurement procedures,...), - to pass previous identified constraints on to producers and nuclear waste package production, - to maintain permanent quality improvement loop, - to lighten the programs of outlets audits, through the acknowledgement of the technical competence of the laboratory to evaluate by gamma spectrometry the activity contained in our nuclear waste drums. On the other hand, the lab is re-evaluated periodically to ensure its continued compliance with requirements: within a 12 month's interval for an internal audit, with a 18 month's period for COFRAC (French sole official national accreditation body). Since 2006, the lab is accredited. His accreditation renewed in 2010. A new entire renewal audit is planned in 2015. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Controller area network decoder (CAN-D)

A system and method for decoding an unknown automotive controller area network (“CAN”) message definitions. CAN data vehicle signal mappings are typically held in secret and varied by automotive model and year. Without knowledge of the mappings, the wealth of real-time vehicle data hidden in the automotive CAN packets is uninterpretable—impeding research, after-market tuning, efficiency and performance monitoring, fault diagnosis, and privacy-related technologies. This technology can ascertain the CAN signals' boundaries (start bit and length), endianness (byte ordering), signedness (binary-to-integer encoding) from raw CAN data. This allows conversion of CAN data to time series. Interpreting the translated CAN data's physical meaning and finding a linear mapping to standard units (e.g., knowing the signal is speed and scaling values to represent units of miles per hour) can be achieved for many signals by leveraging diagnostic standards to obtain real-time measurements of in-vehicle systems. The system and method can be integrated into lightweight hardware enabling an OBD-II plugin for real-time in-vehicle CAN decoding or run on standard computers. The system can output a standard DBC file with the signal definition information.

Verma, Kiren E.↗

System for controller area network payload decoding

A system for decoding an unknown automotive controller area network (“CAN”) message definitions. CAN data vehicle signal mappings are typically held in secret and varied by automotive model and year. Without knowledge of the mappings, the wealth of real-time vehicle data hidden in the automotive CAN packets is uninterpretable—impeding research, after-market tuning, efficiency and performance monitoring, fault diagnosis, and privacy-related technologies. This system can ascertain the CAN signals' boundaries (start bit and length), endianness (byte ordering), signedness (binary-to-integer encoding) from raw CAN data. This allows conversion of CAN data to time series. Interpreting the translated CAN data's physical meaning and finding a linear mapping to standard units (e.g., knowing the signal is speed and scaling values to represent units of miles per hour) can be achieved for many signals by leveraging diagnostic standards to obtain real-time measurements of in-vehicle systems. The system can be integrated into lightweight hardware enabling an OBD-II plugin for real-time in-vehicle CAN decoding or run on standard computers. The system can output a standard DBC file with the signal definition information.

Verma, Kiren E.↗