Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Fault Injection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

LANL Deliverable to the Big Sky Carbon Sequestration Partnership: Preliminary CO 2 -PENS model

The preliminary sub-surface risk assessment for the Kevin Dome includes limited risk factors based on available data. The analysis is presented in five sections. In the first section, we review the Features, Events, and Processes (FEPs) applicable to the CO 2 -PENS model based on a larger set of FEPs developed by Schlumberger. The CO 2 -PENS applicable will be expanded in future work as site-specific data become available. The FEPs addressed in this report include 1) Injectivity and the number of injection wells needed for project success; 2) CO 2 plume extent that will feed future calculations of wellbore, fault, and caprock leakage risks; 3) Performance of production wells related to the projects ability to deliver enough CO 2 to meet project goals; and 4) Caprock leakage due to uncertainty in the caprock permeability.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Model of Inverter-Based Resources

Blackbox modelling for SC analysis is a possible solution. Accuracy can be acceptable even without having vendor control diagrams. Is an NDA required to share a vendor Blackbox model for SC analysis? Differences in VRT detection and injection logics. Angle rotation is not addressed in control logics of most vendors. Current limitation logic during unbalanced faults is not clear. Model IBR as a current source with shunt to improve convergence

IBRs, Model of IBRs, Short Circuit Analysis, Class↗

Impact of Inverter Based Resource Negative Sequence Current Injection on Transmission System Protection

This report documents the results of analysis performed to investigate the impact of inverter-based resource (IBR) response to unbalanced faults on transmission system protective relay dependability and security. Electromagnetic transient (EMT) simulations were performed to simulate IBR response to these faults using existing manufacturer-developed EMT models for four separate IBRs. The study team was composed of IBR manufacturers, relay manufacturers, transmission providers, reliability coordinators and industry consultants with experience in EMT simulation and system protection. The results indicate that under certain conditions, IBR response can result in protective relay misoperations if current protection practices, which were developed based on conventional power sources, are not adapted to the characteristics of IBRs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Thermal drawdown and late‐stage seismic‐slip fault reactivation in enhanced geothermal reservoirs

Abstract Late‐stage seismic slip in geothermal reservoirs has been shown as a potential mechanism for inducing seismic events of magnitudes to ~2.6 as late as two decades into production. We investigate the propagation of fluid pressures and thermal stresses in a prototypical geothermal reservoir containing a centrally located critically stressed fault from a doublet injector and withdrawal well to define the likelihood, timing, and magnitude of events triggered by both fluid pressures and thermal stresses. We define two bounding modes of fluid production from the reservoir. For injection at a given temperature, these bounding modes relate to either low‐ or high‐relative flow rates. At low relative dimensionless flow rates the pressure pulse travels slowly, the pressure‐driven changes in effective stress are muted, but thermal drawdown propagates through the reservoir as a distinct front. This results in the lowest likelihood of pressure‐triggered events but the largest likelihood of late‐stage thermally triggered events. Conversely, at high relative non‐dimensional flow rates the propagating pressure pulse is larger and migrates more quickly through the reservoir but the thermal drawdown is uniform across the reservoir and without the presence of a distinct thermal front, and less capable of triggering late‐stage seismicity. We evaluate the uniformity of thermal drawdown as a function of a dimensionless flow rate Q D that scales with fracture spacing s ( m ), injection rate q ( kg/s ), and the distance between the injector and the target point L ∗ ( Q D ∝ qs 2 / L ∗ ). This parameter enables the reservoir characteristics to be connected with the thermal drawdown response around the fault and from that the corresponding magnitude and timing of seismicity to be determined. These results illustrate that the dimensionless temperature gradient adjacent to the fault dT D / dx D is exclusively controlled by the factor Q D . More significantly, this temperature gradient correlates directly with both the likelihood and severity of triggered events, enabling the direct scaling of likely magnitudes and timing to be determined a priori and directly related to the characteristics of the reservoir. This dimensionless scaling facilitates design for an optimum Q D value to yield both significant heat recovery and longevity of geothermal reservoirs while minimizing associated induced seismicity.

Gan, Quan↗

Simulating Distributed Energy Resource Responses to Transmission System-Level Faults Considering IEEE 1547 Performance Categories on Three Major WECC Transmission Paths

This study performs a large quantity of transmission and distribution simulations for three regions in the Western Interconnection along with final transmission simulations informed by distribution simulation results. Results find that the type of ride-through implemented by distributed energy resources (DERs) is a significant factor to the overall power system response to transmission-level faults. This impact is particularly high for transmission-level faults that depress voltage levels for high numbers of substations (i.e., for cases that experience large regional voltage sags). Because of the programmed nature of the ride-through of IEEE 1547-compliant DERs, the potential for large reductions in real power injection is possible based on IEEE 1547 interpretation and specific implementation. In this study, we made a first attempt to determine the quantity of DERs affected by a variety of transmission-level faults as well as a granular response of distribution-simulated DERs to a few types of IEEE 1547-2003 interpretations and IEEE 1547-2018 voltage ride-through categories. The distribution-informed transmission studies show that the category of IEEE 1547 adherence, particularly with the new 2018 standard, can have a significant impact on the amount of DER-based generation lost following transmission-level fault events.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Prairie State Generating Company 2D Seismic Interpretation

The objectives of the Illinois Storage Corridor (ISC) project are to accelerate commercial deployment of carbon capture utilization and storage at two individual sites and receive approvals for Underground Injection Control (UIC) Class VI permits for construction at each site (ISC Project Narrative, 2020). As part of this project, and as part of the subsurface geologic characterization, two-dimensional (2D) seismic data was acquired at both sites. This report summarizes the findings from two phases of 2D acquisition and seismic interpretation at the Prairie State Generating Company site near Marissa, Illinois. The seismic data indicates the presence of three faults that completely transect the storage and confining units. The initial 2021 2D seismic acquisition revealed the presence of a feature two miles east of the Lively Grove #1 characterization well. The feature is a polyphase fault with a component of strike-slip motion, forming a small positive flower structure. The second phase of 2D seismic acquisition in 2022 constrained the maximum extent of the fault, indicating it has a relatively limited length. Other 2022 seismic lines revealed the presence of two other faults that transect the storage and confining units in the southwest and northeast portions of the 2D seismic acquisition area. The 2021 and 2022 2D seismic surveys have identified three specific locations within the project area that may have an elevated risk of out of zone CO 2 migration due to faulting. Further technical work will be needed to quantify this risk and determine how and if this risk will impact the placement of CO 2 injection wells across the project area.

01 COAL, LIGNITE, AND PEAT↗

Framework for Characterizing Strain in the Vicinity of Leaky Reservoirs

The identification of leaks in the vicinity of reservoirs is critical to determining the feasibility of long-term geologic storage of CO2, methane, wastewater and other fluids. We have established a series of basic reservoir leakage scenarios and performed numerical analysis to characterize the associated pressure and strain fields created from injection into these leaky reservoir settings, as well from ambient loads, such as barometric pressure and earth tides. The end-member conceptual models evaluated include injection and ambient loads applied to: 1) a thin, horizontal layer with no leakage pathways (baseline), 2) a thin layer with a vertical conduit to the surface (e.g., a leaky fault or abandoned well) and 3) a thin layer with a conduit to an overlying aquifer. The pressure and strain fields are sensitive to the reservoir and confining unit geometry, material properties, the distribution, composition and compressibility of the pore fluid and the type of applied load (e.g., constant vs. cyclical injection, barometric pressure fluctuations, earth tides, etc.). Initial results from the numerical analyses indicate that an induced pressure change of 1 MPa in a formation at 1 km depth with a Young’s modulus of 10 GPa is sufficient to create vertical and horizontal strain signals as high as 2 με at a depth of 100 m. The signals predicted from leaky conditions compared to an intact reservoir differ by as much as 0.2 με in magnitude and evolve at different rates. We have developed instruments capable of measuring vertical and horizontal strain at a resolution of better than 5 nε and have recorded repeatable strain signals at 30 m depth in response to wastewater injection into the Avant field in Oklahoma. Based on these findings, strain signals predicted in the shallow subsurface (< 100 m) with numerical analysis are expected to be measurable, and this signal may be inverted to characterize the location and magnitude of leaks, as well as to characterize the geometry and hydromechanical properties of the formation and overlying confining units. This suggests that shallow strain measurements could be a cost effective method for characterizing and monitoring gas storage projects.

Robert, Moak↗

From Inside Out: How the Buried Interface, Shell Defects, and Surface Chemistry Conspire to Determine Optical Performance in Nonblinking Giant Quantum Dots

“Giant” or core/thick‐shell quantum dots (gQDs) are an important class of solid‐state quantum emitter characterized by strongly suppressed blinking and photobleaching under ambient conditions, and reduced nonradiative Auger processes. Together, these qualities provide distinguishing and useful functionality as single‐ and ensemble‐photon sources. For many applications, operation at elevated temperatures and under intense photon flux is desired, but performance is strongly dependent on the synthetic method employed for thick‐shell growth. Here, a comprehensive analysis of gQD structural properties “from the inside out” as a function of shell‐growth method is reported: successive ionic layer adsorption and reaction (SILAR) and high‐temperature continuous injection (HT‐CI), or sequential combinations of the two. Key correlations across synthesis methods, structural features (interfacial alloying, stacking‐fault density and surface‐ligand identity), and performance metrics (quantum yield, single‐gQD photoluminescence under thermal/photo stress, charging behavior and quantum‐optical properties) are identified. Surprisingly, it is found that interfacial alloying is the strongest indicator of gQD stability under stress, but this parameter is not the determining factor for Auger suppression. Furthermore, quantum yield is strongly influenced by surface chemistry and can approach unity even in the case of high shell‐defect density, while introduction of zinc‐blende stacking faults increases the likelihood that a gQD exhibits charged‐state emission.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Water alternative gas (WAG) optimization for a heterogeneous Brazilian pre-salt carbonate reservoir

Water alternating gas (WAG) is a cyclical process that involves alternating water and gas injections with the primary goal to improve sweep efficiency by maintaining initial high pressure, slowing water and gas breakthrough, and lowering oil viscosity. The objective of this work is to apply and optimize a WAG strategy on a carbonate field with light oil, compare it to the initially planned water-flooding strategy, and investigate the capability of WAG to improve field production. In this research, a compositional reservoir simulator was used to model a WAG process by injecting produced gas into the reservoir, using the same well structure as an optimized water-flooding strategy. Subsequently, a WAG strategy was created, optimizing the number and locations of wells, to facilitate a comparative analysis of the two recovery methods. The WAG optimization involved a detailed assessment of variables such as bottom hole pressure (BHP), WAG cycle duration, maximum gas oil ratio (GOR), and well positioning, to achieve a high net present value (NPV). The study focuses on the application of WAG optimization modeling in unconventional reservoirs, specifically pre-salt carbonate reservoirs, and investigates its implications on production strategy and forecast, emphasizing its potential for maximizing NPV and oil recovery in a recently producing field. The results showed that WAG improved reservoir performance when compared to water injection and produced a greater amount of oil. This solution showed potential to be tested under uncertainties (reservoir heterogeneity, faults, fractures, karsts, vugs, etc.) as future steps.

54 ENVIRONMENTAL SCIENCES↗

AGGREGATE: dAta-driven modelinG preservinG contRollable dEr for outaGe mAnagemenT and rEsiliency (Final Report)

The AGGREGATE project team successfully developed and validated various modules for outage management. Brief summaries of each module are provided to showcase their strength for outage management and restoration for a distribution system with a high penetration of connected distribution energy resources (DERs). In recent years, inverter-based DERs have been widely deployed in distribution system. A most of behind-the-meter (BTM) solar power generation is not visible to the utility. The data-driven DER and load estimation modules are using machine learning (ML) and artificial intelligence (AI) to manage this issue, which provides an opportunity for distribution system operators (DSOs) to operate systems and make decisions in real-time for a distribution system with a high penetration of DERs deployed. Also, the estimated DER and true load can be further leveraged in network aggregation and cold-load pick up estimation for reducing the computing complexity and providing for fast restoration. After load demand and DER power generations have been estimated, the information will support topology and state estimation (SE). The topology estimation module demonstrated the viability of mixed integer linear programming (MILP) formulation to estimate the most likely operational radial topology and outage sections using power flow measurements, historical/estimated load and DERs data and smart meter ping measurements. Formulation includes continuous (power flow, load and DERs data) and binary measurements (smart meter ping measurements) in a single formulation. Errors in continuous data and binary data are modeled as normal distribution and Bernoulli distribution, respectively. In the future distribution grid, the power injection from controllable DERs will be essential for efficient and resilient grid operation. However, determining the optimal DER injections and restoration actions is dependent on knowledge of the system states. State estimation (SE), already the cornerstone of transmission energy management systems, will become commonplace in distribution management systems as more measurements become available from deployment of automated metering infrastructure (AMI). Observability analysis is the first step in SE, as it determines the sufficiency of the available measurements for accurately estimating the current system states. A new type of pseudo-measurement called a Correlational Measurement (CM) is introduced in this module, to enhance the observability of the system to enable more accurate SE. CMs encapsulate knowledge of correlation between demand patterns for similar classes of loads as well as injection patterns for same-technology renewable DERs. During grid contingency scenarios, DERs have been traditionally disconnected, without any fault ride-through capabilities. However, with new regulations and better technology, it is feasible for these resources to contribute to the grid’s restoration after an adverse event and hence enhance resilience. The controllability module proposes a two-step restoration scheme for the power system restoration process by leveraging additional degrees of freedom in power electronics interfaced DERs for mitigating voltage problems. In a resilience mode without the utility system, the distribution grid relies on DERs to serve critical load. In such a severe event with multiple faults on the distribution feeders, actuation of various protective devices (PDs) divides the distribution system into electrical islands. The undetected actuated PDs due to fault current contributions from DERs can delay the restoration process, thereby reducing the system resilience. The Advanced Outage Management (AOM) and the Advanced Feeder Restoration (AFR) modules developed in this project provide improved system resilience with multiple DERs. AOM identifies the faulted sections and actuated PDs in a distribution system with DERs by incorporating smart meter data. The most credible outage scenario including fault locations, PD actuations, and fault indicator (FI) failures is identified by a set of binary integer linear programming incorporating hypotheses. The AFR module serves to restore a distribution system with available energy resources taking into consideration the availability of utility sources and DERs. By partitioning the system into islands, critical load will be served with the available generation resources within islands based on the solution of a MILP. When the utility systems become available, the optimal path will be determined by a spanning tree search algorithm that reconnects these islands back to substations and restores the remaining load. The transmission and distribution (T&D) co-simulation module was used to validate the effect of a control action performed on the distribution side assets as it propagates to the transmission side. This ensures that the control action performed results in a feasible operating point on both the transmission and the distribution system. In addition to validation, the team used the T&D co-simulation module to demonstrate how distribution system assets can be used to mitigate issues on the transmission system. Specifically, the team demonstrated that appropriate switching operations on the distribution side can alleviate the line overload condition on the transmission side without causing new operational constraint violations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Pore-pressure diffusion, enhanced by poroelastic stresses, controls induced seismicity in Oklahoma

Induced seismicity linked to geothermal resource exploitation, hydraulic fracturing, and wastewater disposal is evolving into a global issue because of the increasing energy demand. Moderate to large induced earthquakes, causing widespread hazards, are often related to fluid injection into deep permeable formations that are hydraulically connected to the underlying crystalline basement. Using injection data combined with a physics-based linear poroelastic model and rate-and-state friction law, we compute the changes in crustal stress and seismicity rate in Oklahoma. This model can be used to assess earthquake potential on specific fault segments. The regional magnitude–time distribution of the observed magnitude (M) 3+ earthquakes during 2008–2017 is reproducible and is the same for the 2 optimal, conjugate fault orientations suggested for Oklahoma. At the regional scale, the timing of predicted seismicity rate, as opposed to its pattern and amplitude, is insensitive to hydrogeological and nucleation parameters in Oklahoma. Poroelastic stress changes alone have a small effect on the seismic hazard. However, their addition to pore-pressure changes can increase the seismicity rate by 6-fold and 2-fold for central and western Oklahoma, respectively. The injection-rate reduction in 2016 mitigates the exceedance probability of M5.0 by 22% in western Oklahoma, while that of central Oklahoma remains unchanged. A hypothetical injection shut-in in April 2017 causes the earthquake probability to approach its background level by ∼2025. We conclude that stress perturbation on prestressed faults due to pore-pressure diffusion, enhanced by poroelastic effects, is the primary driver of the induced earthquakes in Oklahoma.

58 GEOSCIENCES↗

Simulation of CO2 Sequestration at Rock Spring Uplift, Wyoming: Heterogeneity and Uncertainties in Storage Capacity, Injectivity and Leakage

Many geological, geochemical, geomechanical and hydrogeological factors control CO{sub 2} storage in subsurface. Among them heterogeneity in saline aquifer can seriously influence design of injection wells, CO{sub 2} injection rate, CO{sub 2} plume migration, storage capacity, and potential leakage and risk assessment. This study applies indicator geostatistics, transition probability and Markov chain model at the Rock Springs Uplift, Wyoming generating facies-based heterogeneous fields for porosity and permeability in target saline aquifer (Pennsylvanian Weber sandstone) and surrounding rocks (Phosphoria, Madison and cap-rock Chugwater). A multiphase flow simulator FEHM is then used to model injection of CO{sub 2} into the target saline aquifer involving field-scale heterogeneity. The results reveal that (1) CO{sub 2} injection rates in different injection wells significantly change with local permeability distributions; (2) brine production rates in different pumping wells are also significantly impacted by the spatial heterogeneity in permeability; (3) liquid pressure evolution during and after CO{sub 2} injection in saline aquifer varies greatly for different realizations of random permeability fields, and this has potential important effects on hydraulic fracturing of the reservoir rock, reactivation of pre-existing faults and the integrity of the cap-rock; (4) CO{sub 2} storage capacity estimate for Rock Springs Uplift is 6614 {+-} 256 Mt at 95% confidence interval, which is about 36% of previous estimate based on homogeneous and isotropic storage formation; (5) density profiles show that the density of injected CO{sub 2} below 3 km is close to that of the ambient brine with given geothermal gradient and brine concentration, which indicates CO{sub 2} plume can sink to the deep before reaching thermal equilibrium with brine. Finally, we present uncertainty analysis of CO{sub 2} leakage into overlying formations due to heterogeneity in both the target saline aquifer and surrounding formations. This uncertainty in leakage will be used to feed into risk assessment modeling.

BRINES↗

TOUGH-UDEC: A simulator for coupled multiphase fluid flows, heat transfers and discontinuous deformations in fractured porous media

A numerical simulator entitled TOUGH-UDEC is presented for the assessment of coupled thermal-hydraulic-mechanical processes in fractured porous media. Two existing well-established codes, TOUGH2 and UDEC, are coupled to model multiphase fluid flows, heat transfers, and discontinuous deformations in fractured porous media by means of discrete fracture representation. TOUGH2 is widely used for the modeling of heat transfers and multiphase multicomponent fluid flows, and UDEC is a well-known distinct element code for rock mechanics. The two codes are solved sequentially, with coupling parameters passed to each equation at specific intervals. After solving thermal-hydraulic equations within the TOUGH2 code, pressure and temperature information is imported into the UDEC model. Upon solving the mechanical equation within the UDEC code the calculated fracture apertures are converted to the equivalent permeability and porosity values for a TOUGH2 flow analysis. The solution is calculated by iteratively following an explicit sequence for numerical efficiency. Verifications are presented to demonstrate the capabilities of the coupled TOUGH-UDEC simulator. Three application examples of (1) shear dilation due to increased pore pressure, (2) thermal stress and (3) CO 2 injection, show that the new simulator can be an effective tool for geoengineering applications involving shear activation of fractures and faults.

54 ENVIRONMENTAL SCIENCES↗

DEPEND - A design environment for prediction and evaluation of system dependability

The development of DEPEND, an integrated simulation environment for the design and dependability analysis of fault-tolerant systems, is described. DEPEND models both hardware and software components at a functional level, and allows automatic failure injection to assess system performance and reliability. It relieves the user of the work needed to inject failures, maintain statistics, and output reports. The automatic failure injection scheme is geared toward evaluating a system under high stress (workload) conditions. The failures that are injected can affect both hardware and software components. To illustrate the capability of the simulator, a distributed system which employs a prediction-based, dynamic load-balancing heuristic is evaluated. Experiments were conducted to determine the impact of failures on system performance and to identify the failures to which the system is especially susceptible.

Goswami, Kumar K.↗

Satellite-based measurements of surface deformation reveal fluid flow associated with the geological storage of carbon dioxide

Interferometric Synthetic Aperture Radar (InSAR), gathered over the In Salah CO{sub 2} storage project in Algeria, provides an early indication that satellite-based geodetic methods can be effective in monitoring the geological storage of carbon dioxide. An injected volume of 3 million tons of carbon dioxide, from one of the first large-scale carbon sequestration efforts, produces a measurable surface displacement of approximately 5 mm/year. Using geophysical inverse techniques we are able to infer flow within the reservoir layer and within a seismically detected fracture/ fault zone intersecting the reservoir. We find that, if we use the best available elastic Earth model, the fluid flow need only occur in the vicinity of the reservoir layer. However, flow associated with the injection of the carbon dioxide does appear to extend several kilometers laterally within the reservoir, following the fracture/fault zone.

54 ENVIRONMENTAL SCIENCES↗

Transient fault behavior in a microprocessor: A case study

An experimental analysis is described which studies the susceptibility of a microprocessor based jet engine controller to upsets caused by current and voltage transients. A design automation environment which allows the run time injection of transients and the tracing from their impact device to the pin level is described. The resulting error data are categorized by the charge levels of the injected transients by location and by their potential to cause logic upsets, latched errors, and pin errors. The results show a 3 picoCouloumb threshold, below which the transients have little impact. An Arithmetic and Logic Unit transient is most likely to result in logic upsets and pin errors (i.e., impact the external environment). The transients in the countdown unit are potentially serious since they can result in latched errors, thus causing latent faults. Suggestions to protect the processor against these errors, by incorporating internal error detection and transient suppression techniques, are also made.

Duba, Patrick↗

A novel Lagrangian approach for the stable numerical simulation of fault and fracture mechanics

The simulation of the mechanics of geological faults and fractures is of paramount importance in several applications, such as ensuring the safety of the underground storage of wastes and hydrocarbons or predicting the possible seismicity triggered by the production and injection of subsurface fluids. However, the stable numerical modeling of ground ruptures is still an open issue. The present work introduces a novel formulation based on the use of the Lagrange multipliers to prescribe the constraints on the contact surfaces. The variational formulation is modified in order to take into account the frictional work along the activated fault portion according to the principle of maximum plastic dissipation. The numerical model, developed in the framework of the Finite Element method, provides stable solutions with a fast convergence of the non-linear problem. The stabilizing properties of the proposed model are emphasized with the aid of a realistic numerical example dealing with the generation of ground fractures due to groundwater withdrawal in arid regions. - Highlights: • A numerical model is developed for the simulation of fault and fracture mechanics. • The model is implemented in the framework of the Finite Element method and with the aid of Lagrange multipliers. • The proposed formulation introduces a new contribution due to the frictional work on the portion of activated fault. • The resulting algorithm is highly non-linear as the portion of activated fault is itself unknown. • The numerical solution is validated against analytical results and proves to be stable also in realistic applications.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Voronoi Meshing to Accurately Capture Geological Structure in Subsurface Simulations

Mesh generation lies at the interface of geological modeling and reservoir simulation. Highly skewed or very small grid cells may be necessary to accurately capture the geometry of geological features, but the resulting poorly scaled or small grid cells can have a substantial negative impact on simulator accuracy and speed. One way to minimize numerical errors caused by gridding complex structures is to simulate on high-quality Voronoi meshes, which reduce grid orientation effects in fluid flow. This work presents a complete methodology to create Voronoi simulation grids, model fluid flow in complex geological systems, and visualize the results. A recently developed Voronoi meshing method that can automatically generate provably good unstructured meshes that conform to input surfaces creating closed volumes is used. Initially an analytical benchmark simulation is presented to validate the quality of the meshes and simulation results and demonstrate the superiority of simulation results using Voronoi meshes over flexed-hexahedral meshes on a domain with internal features. Next, meshes are created for test structures representing four of the most common geological features in the subsurface: layering, pinch-out, an interior lens that tapers to zero thickness on all sides and a fault with offset. Two benchmark flow simulations are run for each test structure. Finally, a realistic geological example for CO 2 injection into an anticline is simulated. Three realizations of the Voronoi mesh at the same resolution are generated for the simulations. Each mesh is highly refined near the injection wells and coarse in areas of less interest. These three meshes are used to model the CO 2 plume in the subsurface as it migrates to the top of the structure and then fills downward. Simulations on the meshes with randomly generated elements inside the input volumes each give slightly different fingering patterns for the viscous-unstable buoyant gas flow. The results presented in this work show a promising step towards utilizing fully automated Voronoi meshing for subsurface flow simulations in complex geology.

58 GEOSCIENCES↗