Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Factorization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Pathologic Nodal Classification Is the Most Discriminating Prognostic Factor for Disease-Free Survival in Rectal Cancer Patients Treated With Preoperative Chemoradiotherapy and Curative Resection

Purpose: We retrospectively evaluated the effects of clinical and pathologic factors on disease-free survival (DFS) with the aim of identifying the most discriminating factor predicting DFS in rectal cancer patients treated with preoperative chemoradiotherapy (CRT) and curative resection. Methods and Materials: The study involved 420 patients who underwent preoperative CRT and curative resection between August 2001 and October 2006. Gender, age, distance from the anal verge, histologic type, histologic grade, pretreatment carcinoembryonic antigen (CEA) level, cT, cN, cStage, circumferential resection margin, type of surgery, preoperative chemotherapy, adjuvant chemotherapy, ypT, ypN, ypStage, and tumor regression grade (TRG) were analyzed to identify prognostic factors associated with DFS. To compare the discriminatory prognostic ability of four tumor response-related pathologic factors (ypT, ypN, ypStage, and TRG), the Akaike information criteria were calculated. Results: The 5-year DFS rate was 75.4%. On univariate analysis, distance from the anal verge, histologic type, histologic grade, pretreatment CEA level, cT, circumferential resection margin, type of surgery, preoperative chemotherapeutic regimen, ypT, ypN, ypStage, and TRG were significantly associated with DFS. Multivariate analysis showed that the four parameters ypT, ypN, ypStage, and TRG were, consistently, significant prognostic factors for DFS. The ypN showed the lowest Akaike information criteria value for DFS, followed by ypStage, ypT, and TRG, in that order. Conclusion: In our study, ypT, ypN, ypStage, and TRG were important prognostic factors for DFS, and ypN was the most discriminating factor.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Model to Estimate the Risk of Breast Cancer-Related Lymphedema: Combinations of Treatment-Related Factors of the Number of Dissected Axillary Nodes, Adjuvant Chemotherapy, and Radiation Therapy

Purpose: The development of breast cancer-related lymphedema (LE) is closely related to the number of dissected axillary lymph nodes (N-ALNs), chemotherapy, and radiation therapy. In this study, we attempted to estimate the risk of LE based on combinations of these treatment-related factors. Methods and Materials: A total of 772 patients with breast cancer, who underwent primary surgery with axillary lymph node dissection from 2004 to 2009, were retrospectively analyzed. Adjuvant chemotherapy (ACT) was performed in 677 patients (88%). Among patients who received radiation therapy (n=675), 274 (35%) received supraclavicular radiation therapy (SCRT). Results: At a median follow-up of 5.1 years (range, 3.0-8.3 years), 127 patients had developed LE. The overall 5-year cumulative incidence of LE was 17%. Among the 127 affected patients, LE occurred within 2 years after surgery in 97 (76%) and within 3 years in 115 (91%) patients. Multivariate analysis showed that N-ALN (hazard ratio [HR], 2.81; P<.001), ACT (HR, 4.14; P=.048), and SCRT (HR, 3.24; P<.001) were independent risk factors for LE. The total number of risk factors correlated well with the incidence of LE. Patients with no risk or 1 risk factor showed a significantly lower 5-year probability of LE (3%) than patients with 2 (19%) or 3 risk factors (38%) (P<.001). Conclusions: The risk factors associated with LE were N-ALN, ACT, and SCRT. A simple model using combinations of these factors may help clinicians predict the risk of LE.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Factors that Determine Academic Versus Private Practice Career Interest in Radiation Oncology Residents in the United States: Results of a Nationwide Survey

Purpose: To determine what factors US radiation oncology residents consider when choosing academic or nonacademic careers. Methods and Materials: A 20-question online survey was developed and sent to all US radiation oncology residents to assess factors that influence their career interest. Residents were asked to rate their interest in academics (A) versus private practice (PP) on a 0 (strong interest in A) to 100 (strong interest in PP) scale. Responses were classified as A (0-30), undecided (40-60), and PP (70-100). Residents were also asked to rank 10 factors that most strongly influenced their career interest. Results: Three hundred thirty-one responses were collected, of which 264 were complete and form the basis for this analysis. Factors that correlated with interest in A included having a PhD (P=.018), postgraduate year level (P=.0006), research elective time (P=.0003), obtaining grant funding during residency (P=.012), and number of publications before residency (P=.0001), but not number of abstracts accepted in the past year (P=.65) or publications during residency (P=.67). The 3 most influential factors for residents interested in A were: (1) baseline interest before residency; (2) academic role models; and (3) research opportunities during residency. The 3 most influential factors for residents interested in PP were: (1) baseline interest before residency; (2) academic role models; and (3) academic pressure and obligations. Conclusions: Interest in A correlated with postgraduate year level, degree, and research time during residency. Publications before but not during residency correlated with academic interest, and baseline interest was the most influential factor. These data can be used by residency program directors to better understand what influences residents' career interest.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

E-scooter safety: How attitudinal factors influence risky behavior among shared e-scooter riders

In recent years, e-scooter usage for short-distance trips has grown rapidly. This surge in e-scooter use, combined with the high exposure of e-scooter riders to accident risk, has sparked concerns regarding e-scooter safety. Despite some studies focusing on e-scooter safety, little is known about how attitudinal factors lead e-scooter riders to engage in risky riding behaviors. In this paper, we developed a survey-based empirical model to identify the attitudinal factors influencing engagement in risky behaviors among e-scooter users. We used survey data collected from 420 shared e-scooter users in Chicago in 2022. The survey showed that 47.7% of respondents had experienced at least one collision or fall-off while riding e-scooters. We employed the Partial Least Squares Structural Equation Model (PLS-SEM) to examine the relationships between latent attitudinal factors and risky behavior engagement. Moreover, we conducted Permutation Multi-group Analysis (PMGA) to assess the moderating effect of socio-demographic factors within the estimated model. The findings suggest that riders’ unsafe riding attitude and riding confidence are the most influential factors shaping their risky behavior engagement. In addition, accident experience, infrastructure suitability, perceived enjoyment, traffic risk perception, and operational risk perception are among the other significant predictors. Among socio-demographic factors, gender, age, education, and car use frequency significantly influence riders’ engagement in risky behaviors. The results highlight the importance of infrastructure suitability and accident experience in analyzing e-scooter users’ riding behavior. The developed model advances our understanding of factors contributing to e-scooter riders’ risky behavior engagement. The findings offer valuable insights for policymakers and e-scooter vendors aiming to mitigate e-scooter users’ accident risk. Specifically, we recommend three safety countermeasures: (1) safety training programs to encourage a safer attitude, (2) practice-based initiatives to enhance riding confidence, and (3) infrastructure improvements, especially the expansion of bike lanes.

E-scooter↗

Measurement of Black Carbon and Particle Number Emission Factors from Individual Heavy-Duty Trucks

Emission factors for black carbon (BC) and particle number (PN) were measured from 226 individual heavy-duty (HD) diesel-fueled trucks driving through a 1 km-long California highway tunnel in August 2006. Emission factors were based on concurrent increases in BC, PN, and CO{sub 2}B concentrations (measured at 1 Hz) that corresponded to the passage of individual HD trucks. The distributions of BC and PN emission factors from individual HD trucks are skewed, meaning that a large fraction of pollution comes from a small fraction of the in-use vehicle fleet. The highest-emitting 10% of trucks were responsible for {approx} 40% of total BC and PN emissions from all HD trucks. BC emissions were log-normally distributed with a mean emission factor of 1.7 g kg {sup -1} and maximum values of {approx} 10 g kg{sup -1}. Corresponding values for PN emission factors were 4.7 x 10{sup 15} and 4 x 10{sup 16} kg{sup -1}. There was minimal overlap among high-emitters of these two pollutants: only 1 of the 226 HD trucks measured was found to be among the highest 10% for both BC and PN. Monte Carlo resampling of the distribution of BC emission factors observed in this study revealed that uncertainties (1{sigma}) in extrapolating from a random sample of n HD trucks to a population mean emission factor ranged from {+-} 43% for n = 10 to {+-} 8% for n = 300, illustrating the importance of sufficiently large vehicle sample sizes in emissions studies. Studies with low sample sizes are also more easily biased due to misrepresentation of high-emitters. As vehicles become cleaner on average in future years, skewness of the emissions distributions will increase, and thus sample sizes needed to extrapolate reliably from a subset of vehicles to the entire in-use vehicle fleet are expected to become more of a challenge.

54 ENVIRONMENTAL SCIENCES↗

Prime factorization using quantum variational imaginary time evolution

The road to computing on quantum devices has been accelerated by the promises that come from using Shor’s algorithm to reduce the complexity of prime factorization. However, this promise hast not yet been realized due to noisy qubits and lack of robust error correction schemes. Here we explore a promising, alternative method for prime factorization that uses well-established techniques from variational imaginary time evolution. We create a Hamiltonian whose ground state encodes the solution to the problem and use variational techniques to evolve a state iteratively towards these prime factors. We show that the number of circuits evaluated in each iteration scales as \(O(n^{5}d)\) , where n is the bit-length of the number to be factorized and d is the depth of the circuit. We use a single layer of entangling gates to factorize 36 numbers represented using 7, 8, and 9-qubit Hamiltonians. We also verify the method’s performance by implementing it on the IBMQ Lima hardware to factorize 55, 65, 77 and 91 which are greater than the largest number (21) to have been factorized on IBMQ hardware.

97 MATHEMATICS AND COMPUTING↗

CONSTRAINING THE BULK LORENTZ FACTOR OF GAMMA-RAY BURST OUTFLOW IN THE MAGNETIC-DOMINATED JET MODEL

Recent observations by the Fermi-LAT showed that there are delayed arrivals of GeV photons relative to the onset of MeV photons in some gamma-ray bursts (GRBs). In order to avoid a large optical depth, the minimal value of the Lorentz factor has been estimated to be higher than 1000 in some of the brightest bursts. In this paper, we present a detailed calculation of the time delay between the MeV and GeV photons in the framework of the magnetic-dominated jet model. We find that the time delay strongly depends on the saturated bulk Lorentz factor of the jet. Inspired by this fact, we use this model to calculate the Lorentz factors of the four brightest Fermi bursts. The results indicate that the Lorentz factors are much smaller than those obtained from the 'single-zone' scenario. The short burst GRB 090510 has a minimal Lorentz factor of 385, while the three long bursts, GRB 080916c, GRB 090902b, and GRB 090926, have almost the same Lorentz factors with an average value near 260. Another interesting result is that, for long bursts, GeV photons are emitted after the bulk Lorentz factor saturates. For the short GRB, however, MeV and GeV photons are emitted at the same phase, i.e., either in the expansion phase or in the coasting phase.

79 ASTRONOMY AND ASTROPHYSICS↗

DETERMINING THE COVERING FACTOR OF COMPTON-THICK ACTIVE GALACTIC NUCLEI WITH NuSTAR

The covering factor of Compton-thick (CT) obscuring material associated with the torus in active galactic nuclei (AGNs) is at present best understood through the fraction of sources exhibiting CT absorption along the line of sight (N{sub H} > 1.5 × 10{sup 24} cm{sup −2}) in the X-ray band, which reveals the average covering factor. Determining this CT fraction is difficult, however, due to the extreme obscuration. With its spectral coverage at hard X-rays (>10 keV), Nuclear Spectroscopic Telescope Array (NuSTAR) is sensitive to the AGNs covering factor since Compton scattering of X-rays off optically thick material dominates at these energies. We present a spectral analysis of 10 AGNs observed with NuSTAR where the obscuring medium is optically thick to Compton scattering, so-called CT AGNs. We use the torus models of Brightman and Nandra that predict the X-ray spectrum from reprocessing in a torus and include the torus opening angle as a free parameter and aim to determine the covering factor of the CT gas in these sources individually. Across the sample we find mild to heavy CT columns, with N{sub H} measured from 10{sup 24} to 10{sup 26} cm{sup −2}, and a wide range of covering factors, where individual measurements range from 0.2 to 0.9. We find that the covering factor, f{sub c}, is a strongly decreasing function of the intrinsic 2–10 keV luminosity, L{sub X}, where f{sub c} = (−0.41 ± 0.13)log{sub 10}(L{sub X}/erg s{sup −1})+18.31 ± 5.33, across more than two orders of magnitude in L{sub X} (10{sup 41.5}–10{sup 44} erg s{sup −1}). The covering factors measured here agree well with the obscured fraction as a function of L{sub X} as determined by studies of local AGNs with L{sub X} > 10{sup 42.5} erg s{sup −1}.

79 ASTRONOMY AND ASTROPHYSICS↗

CONSTRAINTS ON THE BULK LORENTZ FACTORS OF GRB X-RAY FLARES

X-ray flares were discovered in the afterglow phase of gamma-ray bursts (GRBs) by the Swift satellite a decade ago and are known as a canonical component in GRB X-ray afterglows. In this paper, we constrain the Lorentz factors of GRB X-ray flares using two different methods. For the first method, we estimate the lower limit on the bulk Lorentz factor with the flare duration and jet break time. In the second method, the upper limit on the Lorentz factor is derived by assuming that the X-ray flare jet has undergone saturated acceleration. We also re-estimate the initial Lorentz factor with GRB afterglow onsets, and find the coefficient of the theoretical Lorentz factor is 1.67 rather than the commonly used 2 for the interstellar medium (ISM) and 1.44 for the wind case. We find that the correlation between the limited Lorentz factor and the isotropic radiation energy of X-ray flares in the ISM case is more consistent with that of prompt emission than the wind case in a statistical sense. For a comparison, the lower limit on the Lorentz factor is statistically larger than the extrapolation from prompt bursts in the wind case. Our results indicate that X-ray flares and prompt bursts are produced by the same physical mechanism.

79 ASTRONOMY AND ASTROPHYSICS↗

Factorized QED and QCD contribution to deeply inelastic scattering

We present the first calculation of next-to-leading order (NLO) factorized QED and QCD contributions to the short-distance hard coefficients of inclusive lepton-hadron deep inelastic scattering (DIS) in a joint QED and QCD factorization approach. Unlike the traditional radiative correction approach to handle the collision-induced QED contributions to DIS, QED radiation from all charged leptons and quarks are treated equally, and their collinear sensitivities are systematically factorized into corresponding universal lepton and parton distribution functions. We demonstrate that the NLO factorized short-distance QED contribution is completely infrared safe and calculable without the need of any parameters other than the standard factorization scale in the same way as the factorized short-distance QCD contribution. We discuss the potential impact of this joint factorization approach on the extraction of partonic information from lepton-hadron DIS.

Deep inelastic scattering↗

Extraction of the neutron electric form factor from measurements of inclusive double spin asymmetries

Background: Measurements of the neutron charge form factor, G$n\atop{E}$, are challenging because the neutron has no net charge. Additionally, measurements of the neutron form factors must use nuclear targets which require accurately accounting for nuclear effects. Extracting G$n\atop{E}$ with different targets and techniques provides an important test of our handling of these effects. Purpose: The goal of the measurement was to use an inclusive asymmetry measurement technique to extract the neutron charge form factor at a four-momentum transfer of 1 (GeV/c) 2 . This technique has very different systematic uncertainties than traditional exclusive measurements and thus serves as an independent check of whether nuclear effects have been taken into account correctly. Method: The inclusive quasielastic reaction 3 $→\atop{He}$ ($→\atop{e}$, e') was measured at Jefferson Laboratory. The neutron electric form factor, G$n\atop{E}$, was extracted at Q 2 = 0.98 ( GeV/c) 2 from ratios of electron-polarization asymmetries measured for two orthogonal target spin orientations. This Q 2 is high enough that the sensitivity to G$n\atop{E}$ is not overwhelmed by the neutron magnetic contribution, and yet low enough that explicit neutron detection is not required to suppress pion production. Results: The neutron electric form factor, G$n\atop{E}$, was determined to be 0.0414 ± 0.0077 ( stat ) ± 0.0022 ( syst ), providing the first high-precision inclusive extraction of the neutron's charge form factor. In conclusion: The use of the inclusive quasielastic 3 $→\atop{He}$ ($→\atop{e}$, e') with a four-momentum transfer near 1 (GeV/c) 2 has been used to provide a unique measurement of G$n\atop{E}$. This new result provides a systematically independent validation of the exclusive extraction technique results and implies that the nuclear corrections are understood. This is contrary to the proton form factor where asymmetry and differential cross section measurements have been shown to have large systematic differences.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Local dynamics of proteins and DNA evaluated from crystallographic B factors

Distributions of scaled B factors from 704 protein–DNA complexes reflect primarily the neighbourhood of amino-acid and nucleotide residues: their flexibility grows from the protein core to protein–protein and protein–DNA interfaces, to solvent-exposed residues. Some of the findings clearly observed at higher resolution structures can no longer be observed for structures at low resolution indicating problems in refinement protocols. The dynamics of protein and nucleic acid structures is as important as their average static picture. The local molecular dynamics concealed in diffraction images is expressed as so-called B factors. To find out how the crystal-derived B factors represent the dynamic behaviour of atoms and residues of proteins and DNA in their complexes, the distributions of scaled B factors from a carefully curated data set of over 700 protein–DNA crystal structures were analyzed [Schneider et al. (2014 ▶), Nucleic Acids Res.42, 3381–3394]. Amino acids and nucleotides were categorized based on their molecular neighbourhood as solvent-accessible, solvent-inaccessible (i.e. forming the protein core) or lying at protein–protein or protein–DNA interfaces; the backbone and side-chain atoms were analyzed separately. The B factors of two types of crystal-ordered water molecules were also analyzed. The analysis confirmed several expected features of protein and DNA dynamics, but also revealed surprising facts. Solvent-accessible amino acids have B factors that are larger than those of residues at the biomolecular interfaces, and core-forming amino acids are the most restricted in their movement. A unique feature of the latter group is that their side-chain and backbone atoms are restricted in their movement to the same extent; in all other amino-acid groups the side chains are more floppy than the backbone. The low values of the B factors of water molecules bridging proteins with DNA and the very large fluctuations of DNA phosphates are surprising. The features discriminating different types of residues are less pronounced in structures with lower crystallographic resolution. Some of the observed trends are likely to be the consequence of improper refinement protocols that may need to be rectified.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Effect of Coaxial Electrode Geometry on the Electric Field Enhancement Factor for a High Voltage Vacuum Gap

We present an experimental analysis of the change in the electric field enhancement factor with varying gap size and penetration depth (P.D) of cathode into anode for a coaxial vacuum gap, diagnosed using Fowler–Nordheim analysis and optical imaging via scanning electron microscope (SEM) and time integrated Digital single lens reflex camera (DSLR). Data were collected on the Coaxial Gap Breakdown Machine (240 A, 25 kV, 150 ns, 0.1 Hz). Experiments using five different gap sizes at nine different P.Ds are compared over runs comprising 50 shots for each case. The results show a strong link between enhancement factor and gap size, with P.D and surface topology. For large gap sizes, 150, 330, and 700 μm, the average enhancement factor value increases with increasing P.D. For smaller gap sizes, 50 and 100 μm, the average enhancement factor decreases with P.D. SEM imaging before and after plasma formation for each gap size allows for quantifying surface finish, microprotrusion growth, average blast diameter, and an estimation of the surface area breakdowns occupy. Time integrated DSLR imaging analysis of the gap at each shot allows for a determination of the distribution of breakdowns about the circumference of the gap for each case tested. Here, the Fowler–Nordheim analysis allows for a quantitative analysis of the surface roughness of all gap sizes tested. Results show that for large gap sizes, the gap geometry and increasing area of breakdown is the main cause for increasing average enhancement factor. For small gap sizes, the dominant driving factor for small average enhancement factors—that subsequently decrease with P.D—is significant changes in surface topology due to an increased number of breakdowns.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Experimental Study on the Effect of Localized Blockages on the Friction Factor of a 61-Pin Wire-Wrapped Bundle

Abstract The thermal-hydraulic behavior of the flow in rod bundles has motivated numerous experimental and computational investigations. Previous studies have identified potential for accumulation of debris within the small subchannels of typical wire-wrapped assemblies with subsequent total or partial blockage of subchannel coolant flow. A test campaign was conducted to study the effects of localized blockages on the bundle averaged friction factor of a tightly packed wire-wrapped rod bundle. Blockages were installed within the bundle, and fluid pressure drop was measured across one wire pitch for a Reynolds number range of 500–17,200. The Darcy–Weisbach friction factor of the perturbed rod bundle geometry was compared with that of the unblocked bundle, as well as with the predictions of a well-established friction factor correlation. Differing effects based on blockage size and location for various flow regimes were studied. A number of conclusions can be made about the effects of the blockages on the friction factor, such as an increasing effect of the blockage on friction factor with an increase in Reynolds number, a change in flow behavior in the turbulent transition flow regime near Reynolds number 3000, differences in effect on friction factor for different types of subchannel blockage, and a nonlinear trend in friction factor variation with flow area impeded for edge subchannels. To this end, all data and quantified uncertainty produced in this study are made available for comparison and validation of advanced computational tools.

Engineering↗

Factors for converting dose measured in polystyrene phantoms to dose reported in water phantoms for incident proton beams

Purpose: Previous dosimetry protocols allowed calibrations of proton beamline dose monitors to be performed in plastic phantoms. Nevertheless, dose determinations were referenced to absorbed dose-to-muscle or absorbed dose-to-water. The IAEA Code of Practice TRS 398 recommended that dose calibrations be performed with ionization chambers only in water phantoms because plastic-to-water dose conversion factors were not available with sufficient accuracy at the time of its writing. These factors are necessary, however, to evaluate the difference in doses delivered to patients if switching from calibration in plastic to a protocol that only allows calibration in water. Methods: This work measured polystyrene-to-water dose conversion factors for this purpose. Uncertainties in the results due to temperature, geometry, and chamber effects were minimized by using special experimental set-up procedures. The measurements were validated by Monte Carlo simulations. Results: At the peak of non-range-modulated beams, measured polystyrene-to-water factors ranged from 1.015 to 1.024 for beams with ranges from 36 to 315 mm. For beams with the same ranges and medium sized modulations, the factors ranged from 1.005 to 1.019. The measured results were used to generate tables of polystyrene-to-water dose conversion factors. Conclusions: The dose conversion factors can be used at clinical proton facilities to support beamline and patient specific dose per monitor unit calibrations performed in polystyrene phantoms.

61 RADIATION PROTECTION AND DOSIMETRY↗

Correction factors for ionization chamber dosimetry in CyberKnife: Machine-specific, plan-class, and clinical fields

Purpose: The aim of this work is the application of the formalism for ionization chamber reference dosimetry of small and nonstandard fields [R. Alfonso, P. Andreo, R. Capote, M. S. Huq, W. Kilby, P. Kjaell, T. R. Mackie, H. Palmans, K. Rosser, J. Seuntjens, W. Ullrich, and S. Vatnitsky, 'A new formalism for reference dosimetry of small and nonstandard fields,' Med. Phys. 35, 5179-5186 (2008)] to the CyberKnife robotic radiosurgery system. Correction factors for intermediate calibration fields, a machine-specific reference field (msr) and two plan-class specific reference fields (pcsr), have been studied. Furthermore, the applicability of the new formalism to clinical dosimetry has been analyzed through the investigation of two clinical treatments. Methods: PTW31014 and Scanditronix-Wellhofer CC13 ionization chamber measurements were performed for the fields under investigation. Absorbed dose to water was determined using alanine reference dosimetry, and experimental correction factors were calculated from alanine to ionization chamber readings ratios. In addition, correction factors were calculated for the intermediate calibration fields and one of the clinical treatment fields using the Monte Carlo method and these were compared with the experimental values. Results: Overall correction factors deviating from unity by approximately 2% were obtained from both measurements and simulations, with values below and above unity for the studied intermediate calibration fields and clinical fields for the ionization chambers under consideration. Monte Carlo simulations yielded correction factors comparable with those obtained from measurements for the machine-specific reference field, although differences from 1% to 3.3% were observed between measured and calculated correction factors for the composite intermediate calibration fields. Dose distribution inhomogeneities are thought to be responsible for such discrepancies. Conclusions: The differences found between overall correction factors associated with the proposed intermediate calibration fields and the clinical fields under investigation show that depending on the clinical field and the detector used, either a machine-specific reference field or a plan-class specific reference field is more representative for the clinical field. Given the experimental and numerical uncertainties and the small number of clinical fields considered in this study the significance of these observations is limited and it remains unclear for the CyberKnife if there would be a significant gain in using a pcsr field rather than a msr field as reference field for relative dosimetry.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-246: MU Model Implementation for a Passively Scattered Proton Beam: Inclusion of the Bolus Gap and Nozzle Extension Factors

Purpose: To develop and implement an MU model for a passively scattered proton beam, and eliminate the need for patient specific calibrations for field sizes from 3cm to 15cm. This would enable consistent and timely calibrations for a wide variety of patient portals, streamlining the treatment process. Methods: Measurements were initially made using a Standard Imaging A-16 ion chamber and a modified water tank to determine the bolus gap factors (BGF) for multiple combinations of aperture size, bolus thickness, and air gap. The BGF was then separated into two component factors: the bolus thickness factor (BTF) and the nozzle extension factor (NEF). Polynomial curves were generated using the measured data to produce BTF tables for air gaps from 0cm to 30cm and for bolus thicknesses from 0cm to 10cm, and NEF tables for the full range of clinically used nozzle extensions. Additionally, data tables were created for every factor that affects beam output in the MU model. The MUs were then modeled for 487 patient portals and retrospectively compared to the MUs generated from the physical calibrations previously performed. Results: Of the 487 patient portals tested, 100% of the portals used for the comparison were within 2.5% from the MUs generated using a physical calibration, and 95.9% of the MU model portals tested were within 2%. The patient portals tested had field sizes ranging from 2.1cm to 10.1cm, with air gaps from 2cm to 25cm. Output factors for field sizes below 3cm with irregularly shaped fields demonstrated inconsistent results and will be further studied. Conclusion: The most problematic output factor, the BGF, was modeled accurately and consistently using the lowest order polynomial curve fits and interpolation between measured data. The study results demonstrate the robustness of the MU model and the potential for saving valuable personnel and beam time.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-T-491: Importance of Energy Dependent Protons Per MU Calibration Factors in IMPT Dose Calculations Using Monte Carlo Technique

Purpose: In intensity modulated proton therapy (IMPT), energy dependent, protons per monitor unit (MU) calibration factors are important parameters that determine absolute dose values from energy deposition data obtained from Monte Carlo (MC) simulations. Purpose of this study was to assess the sensitivity of MC-computed absolute dose distributions to the protons/MU calibration factors in IMPT. Methods: A “verification plan” (i.e., treatment beams applied individually to water phantom) of a head and neck patient plan was calculated using MC technique. The patient plan had three beams; one posterior-anterior (PA); two anterior oblique. Dose prescription was 66 Gy in 30 fractions. Of the total MUs, 58% was delivered in PA beam, 25% and 17% in other two. Energy deposition data obtained from the MC simulation were converted to Gy using energy dependent protons/MU calibrations factors obtained from two methods. First method is based on experimental measurements and MC simulations. Second is based on hand calculations, based on how many ion pairs were produced per proton in the dose monitor and how many ion pairs is equal to 1 MU (vendor recommended method). Dose distributions obtained from method one was compared with those from method two. Results: Average difference of 8% in protons/MU calibration factors between method one and two converted into 27 % difference in absolute dose values for PA beam; although dose distributions preserved the shape of 3D dose distribution qualitatively, they were different quantitatively. For two oblique beams, significant difference in absolute dose was not observed. Conclusion: Results demonstrate that protons/MU calibration factors can have a significant impact on absolute dose values in IMPT depending on the fraction of MUs delivered. When number of MUs increases the effect due to the calibration factors amplify. In determining protons/MU calibration factors, experimental method should be preferred in MC dose calculations. Research supported by National Cancer Institute grant P01CA021239.

60 APPLIED LIFE SCIENCES↗