Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FREQUENCY STANDARDS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Interval Counter Measures Stability Of Frequency

Propagation of errors and effects of dead time suppressed. System includes precise timing-pulse generator with interval counter and suitably programmed computer determines relative stability or instability of frequency of two signals differing in frequency by about 1 Hz. Designed for use in frequency-standards laboratory.

Greenhall, C. A.↗

Radio propagation experiments in the outer solar system with Voyager

The outer solar system's planetary atmospheres, ionospheres, rings, and magnetic fields are under study in light of microwave telecommunications from the two Voyager spacecraft. The use of the hydrogen maser frequency standards on the ground, in conjunction with thermally controlled quartz oscillators aboard the spacecraft, ensures long coherence intervals and allows the application of novel signal processing methods. On this basis, studies of atmospheric structure and scintillation parameters, planetary ring structure, and magnetic control of small ionospheric irregularities have been undertaken; information concerning planetary evolution, composition, and dynamics is thereby obtained.

Tyler, G. Leonard↗

Power-Supply-Conditioning Circuit

Fluctuations of voltage suppressed in power supplies for precise radio-frequency circuits. Circuit suppresses both periodic and random deviations of dc supply voltage from desired steady level. Highly-stable feedback voltage regulator, conditioner intended in conjunction with conventional power-supply circuit to provide constant voltage to atomic frequency standard or other precise oscillator. Without conditioners, outputs of most commercial power supplies contain fluctuations causing unacceptably-large phase and amplitude modulation of precise oscillators.

Primas, L. E.↗

Improving Estimates Of Phase Parameters When Amplitude Fluctuates

Adaptive inverse filter applied to incoming signal and noise. Time-varying inverse-filtering technique developed to improve digital estimate of phase of received carrier signal. Intended for use where received signal fluctuates in amplitude as well as in phase and signal tracked by digital phase-locked loop that keeps its phase error much smaller than 1 radian. Useful in navigation systems, reception of time- and frequency-standard signals, and possibly spread-spectrum communication systems.

Vilnrotter, V. A.↗

An apparatus for the electrodynamic containment of charged macroparticles

The dynamic moition of the ions contained in the trapped (199)Hg+ frequency standard contributes to the stability of the standard. In order to study these dynamics, a macroscopic analog of the (199)Hg+ trap is constructed. Containment of micron-sized particles in this trap allows direct visual observation of the particles' motion. Influenced by the confining fields and their own Coulomb repulsion, the particles can form stable arrays.

Williams, A.↗

Information content of a single pass of phase-delay data from a short baseline connected element interferometer

An analytic development of the information array obtained with a single tracking pass of phase-delay measurements made from a short baseline interferometer is presented. Phase-delay observations can be made with great precision from two antennas using a single, common distributed frequency standard, hence the name connected element. With the information array, closed-form expressions are developed for the error covariance in declination and right ascension. These equations serve as useful tools for analyzing the relative merits of candidate station locations for connected element interferometry (CEI). The navigation performance of a short baseline interferometer located at the Deep Space Network's (DSN's) Goldstone intracomplex is compared with that which is presently achievable using Very Long Baseline Interferometry (VLBI) over intercontinental baselines. The performance of an intracomplex pair of short baselines formed by three stations is also investigated, along with the use of a single baseline in conjunction with conventional two-way Doppler data. The phase-delay measurement accuracy and data rate used in the analysis are based on the expected performance of an experimental connected element system presently under construction at Goldstone. The results indicate that the VLBI system that will be used during the Galileo mission can determine the declination and right ascension of a distant spacecraft to an accuracy of 20 to 25 nrad, while the CEI triad system and the combination of CEI-Doppler system are both capable of 30 to 70 nrad performance.

Thurman, S. W.↗

Comparison of earth-based radio metric data strategies for deep space navigation

Spacecraft angular coordinates can be determined with a variety of radio tracking measurements, such as Doppler, range, and Very Long Baseline Interferometry (VLBI)-derived data types. A relatively new interferometric tracking technique under development is Connected Element Interferometry (CEI), which uses a single frequency standard, distributed to two antennas spaced 10 to 100 km apart, to make highly accurate measurements of the phase-delay of incoming radio signals. The angular navigation accuracies attainable with Doppler, range, CEI, and VLBI data strategies are compared, using simple analytic models for these data types. The measurement accuracies assumed for Doppler, range, and VLBI data represent the performance expected from these systems in the Magellan and Galileo missions, while the assumed CEI data accuracy represents the anticipated performance of an experimental connected element system being constructed at the Deep Space Network's Goldstone, California complex. The results indicate that the Galileo VLBI system can deliver 20- to 25-nrad accuracy throughout the ecliptic plane. A hypothetical CEI dual-baseline sysem at Goldstone yielded accuracies in the 35- to 50-nrad range, while another hypothetical Goldstone-based system, consisting of a single CEI baseline and an X-band (8.4 GHz) Doppler system, produced accuracies of 25 to 100 nrad. Angular accuracies obtained from Doppler and range were found to be highly dependent upon the sensitivity of earth-spacecraft differential acceleration to small changes in geocentric spacecraft position.

Thurman, Sam W.↗

Keynote address: The past, present, and future of atomic time

The early history of atomic time and frequency standards is reviewed. The most accurate and stable present standards are described. Prospective future improvements are discussed, particularly those with laser cooling and with trapped ions and atoms.

Ramsey, Norman F.↗

A highly stable crystal oscillator applied to geodetic VLBI experiment

Instead of a hydrogen maser, a carefully selected Crystal oscillator which is phase locked to a Cesium (Cs) frequency standard of a geodetic VLBI experiment. The domestic VLBI experiment with 55 km baseline using the Crystal oscillator at one end was made in Japan and the obtained error of the baseline vector components were 4 cm, and that of the baseline length was 3 cm. This system may be operated after only 2 hours warm up. These results coincides with those of conventional geodetic Laser ranging and VLBI using a hydrogen maser within the formal error. A VLBI experiment with over 1000 km baselines were carried out successfully from October 1988, and over 11000 km baseline between Japan and Antarctica was carried out successfully in January 1990.

Kiuchi, Hitoshi↗

Improved Zero-Crossing Detector

Improved zero-crossing-detector circuit designed for precisely measuring difference between frequencies of two frequency-standard signal sources. Contains low-bandwidth first-stage amplifier and three limiting amplifiers, each "squares" signal bit more. Crosstalk eliminated and jitter reduced to about 10 to the negative 7th power microseconds.

Dick, G. John↗

Four-Sector Cylindrical Radio-Frequency Ion Trap

Proposed linear radio-frequency ion trap consists of closed metal cylinder partitioned into four equal cylindrical-sector electrodes and two circular end electrodes. Features include relatively large ion-storage capacity and shielding against external fields. Used in frequency-standard laboratories to confine 199Hg+ ions electrodynamically in isolation from external environment. Similar to device described in "Linear Ion Trap for Atomic Clock" (NPO-17758).

Melbourne, Ruthann K.↗

Issues and status of power distribution options for space exploration

The Space Exploration Initiative (SEI) will need a wide variety of manned systems with requirements significantly different than those for existing systems. The concept of a space power utility is discussed and the impact of this concept on the engineering of space power systems is examined. Almost all existing space power systems use low voltage direct current. Although they have been very succesful, increasing power system requirements in recent years have exposed their inherent limitations and led to the proposal of a number of alternatives including high voltage DC and AC at various frequencies. Drawing on the experience gained from Space Station Freedom and SEI systems studies, factors that may affect the choice of frequency standards on which to build such a space power utility are discussed.

Bercaw, Robert W.↗

Measurement of precision oscillator phase noise using the two-oscillator coherent down-conversion technique

The characterization of precision frequency standard phase noise and spurious outputs is addressed, using the two-oscillator coherent downconversion technique. Focus is on techniques for making accurate measurements of phase noise and spurious outputs within 100 KHz of a carrier. Significant sources of measurement error related to hardware design problems and inadequate measurement procedures are discussed: measurement errors resulting from system noise sources, phase-locked loop effects, and system bandwidth limitations. In addition, methods and design considerations for minimizing the effects of such errors are presented. Analytic discussions and results are supplemented with actual test data and measurements made using measurement hardware developed at the Ball Corporation, Efratom Division.

Christopher J. Pagnanelli↗

Method of recertifying a loaded bearing member

A method is described of recertifying a loaded bearing member using ultrasound testing to compensate for different equipment configurations and temperature conditions. The standard frequency F1 of a reference block is determined via an ultrasonic tone burst generated by a first pulsed phased locked loop (P2L2) equipment configuration. Once a lock point number S is determined for F1, the reference frequency F1a of the reference block is determined at this lock point number via a second P2L2 equipment configuration to permit an equipment offset compensation factor Fo1=((F1-F1a)/F1)(1000000) to be determined. Next, a reference frequency F2 of the unloaded bearing member is determined using a second P2L2 equipment configuration and is then compensated for equipment offset errors via the relationship F2+F2(Fo1)/1000000. A lock point number b is also determined for F2. A resonant frequency F3 is determined for the reference block using a third P2L2 equipment configuration to determine a second offset compensation factor F02=((F1-F3)/F1) 1000000. Next the resonant frequency F4 of the loaded bearing member is measured at lock point number b via the third P2L2 equipment configuration and the bolt load determined by the relationship (-1000000)CI(((F2-F4)/F2)-Fo2), wherein CI is a factor correlating measured frequency shift to the applied load. Temperature compensation is also performed at each point in the process.

Allison, Sidney G.↗

Electrical system options for space exploration

The need for a space power utility concept is discussed and the impact of this concept on the engineering of space power systems is examined. Experiences gained from Space Station Freedom and SEI systems studies are used to discuss the factors that may affect the choice of frequency standards on which to build such a space power utility. Emphasis is given to electrical power control, conditioning, and distribution subsystems.

Bercaw, Robert W.↗

Nonlinear feedback control of highly manoeuvrable aircraft

This paper describes the application of nonlinear quadratic regulator (NLQR) theory to the design of control laws for a typical high-performance aircraft. The NLQR controller design is performed using truncated solutions of the Hamilton-Jacobi-Bellman equation of optimal control theory. The performance of the NLQR controller is compared with the performance of a conventional P + I gain scheduled controller designed by applying standard frequency response techniques to the equations of motion of the aircraft linearized at various angles of attack. Both techniques result in control laws which are very similar in structure to one another and which yield similar performance. The results of applying both control laws to a high-g vertical turn are illustrated by nonlinear simulation.

Garrard, William L.↗

Hyperfine structure and isotope shifts of transitions in neutral and singly ionized ytterbium

The present experimental investigation of the hyperfine structure and isotopic shifts of transitions in neutral and singly-ionized Yb, which constitute a system of some interest to microwave-frequency standards, used counterpropagating pump and probe laser beams directed through a hollow-cathode discharge lamp. The results obtained are in agreement with previous measurements except in the case of the Yb-173(+) 6 2P0 sub 3/2 state, which is more accurately determined.

Berends, R. W.↗

Hydrogen-Maser/Ruby-Maser/Quartz-Crystal Oscillator

Highly stable oscillator suitable for use as 100-MHz frequency standard consists of 100-MHz hydrogen maser combined with double-phase-locked-loop receiver. Generates 100-MHz signal with reduced noise. Contains 100-MHz voltage-controlled quartz-crystal oscillator (VCO) locked in phase to superconducting-cavity maser oscillator (SCMO). SCMO, locks in phase to hydrogen maser, phase-locking receiver and its SCMO/ VCO combination to hydrogen maser. Aspects of SCMO described in previous reports, including "Performance of Superconducting-Cavity Maser" (NPO-18175), NASA Tech Briefs, Vol. 15, No. 6. Performances of component oscillators complement each other.

Wang, Rabi T.↗