Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FOCUSING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Principles of Ion Selection, Alignment, and Focusing in Tandem Ion Mobility Implemented Using Structures for Lossless Ion Manipulations (SLIM)

Tandem ion mobility (IM) enables the characterization of subpopulations of ions from larger ensembles, including differences that cannot be resolved in a single dimension of IM. Tandem IM consists of at least two IM regions that are each separated by an ion selection region. In many implementations of tandem IM, ions eluting from a dimension of separation are filtered and immediately transferred to the subsequent dimension of separation (selection-only experiments). We recently reported a mode of operation in which ions eluting from a dimension are trapped prior to the subsequent dimension (selection-trapping experiments), which was implemented on an instrument constructed using the structures for lossless ion manipulations (SLIM) architecture. Here, we use a combination of experiments and trajectory simulations to characterize aspects of the selection, trapping, and separation processes underlying these modes of operation. For example, the actual temporal profile of filtered ions can be very similar to the width of the waveforms used for selection, but depending on experimental parameters, can differ by up to ± 500 μs. Experiments and simulations indicate that ions in selection-trapping experiments can be spatially focused between dimensions, which removes the broadening that occurred during the preceding dimension. During focusing, individual ions are thermalized, which aligns and establishes common initial conditions for the subsequent dimension. Therefore, selection-trapping experiments appear to offer significant advantages relative to selection-only experiments, which we anticipate will become more pronounced in future experiments that make use of longer IM separations, additional dimensions of analysis, and the outcomes of this study. .

74 ATOMIC AND MOLECULAR PHYSICS↗

An experimental study of ovarian cancer imaging and therapy by paclitaxel-loaded phase-transformation lipid nanoparticles combined with low-intensity focused ultrasound

Highlights: • PTX-anti-LHRHR-PTNPs is expected to become a new type of ultrasound contrast agent. • LIFU can enhance the efficiency of PTX-anti-LHRHR-PTNPs. • For ovarian cancer, PTX-anti-LHRHR-PTNPs has a good therapeutic effect. Drug-loaded phase-transformation lipid nanoparticles (NPs) combined with low-intensity focused ultrasound (LIFU) for ultrasound molecular imaging and therapy, which is a very promising drug carrier and can provide both physical and chemical therapeutics, simultaneously. We successfully prepared the paclitaxel (PTX) loaded anti-LHRHR targeted phase-transformation lipid nanoparticles (PTX-anti-LHRHR-PTNPs) for ovarian cancer in this study combined with LIFU has the following characteristics: On the one hand, it showed smaller size and greater stability than blood cells, which significantly prolonged its half-life in the body, and can actively target ovarian cancer OVCAR-3 cells, and smoothly penetrate the endothelial gap into the tumor site for specifically killing the ovarian cancer cells. Thereby, the special drug carrier improved the therapeutic effect and reduced toxic and side effects, maximized the protection of normal tissues and minimized adverse reactions. On the other hand, PTX-anti-LHRHR-PTNPs can be targeted to focus after being injected intravenously and remain in the tumor target tissue for a long time. At the same time, liquid-gas phase-transformation can occur under LIFU triggering, resulting in more ideal and sustained ultrasound imaging effects. Then acoustic contrast agent is used to develop the molecular level of ultrasound scattering, so as to evaluate the diseased tissue from the molecular level.

60 APPLIED LIFE SCIENCES↗

FOCUS: A full-orbit CUDA solver for particle simulations in magnetized plasmas

A Full-Orbit CUDA Solver for particle simulations in plasmas, FOCUS, has been developed. The code follows exact particle trajectories by solving Newton’s equations with the Lorentz force. The code can use fields calculated analytically or numerically and it is also possible to use the information provided by equilibrium reconstruction and transport codes. FOCUS has an elastic collisions module which covers the whole particle energy range in magnetic fusion devices. Moreover, an atomic collision module was also included to simulate the interaction of the test particles with neutral or partially ionized species. Regarding performance, the main feature is that the code runs on GPUs, allowing the simulation of a large number of particles using moderate computational resources. Different versions of the code have been used in several papers. Here we present a complete description of its capabilities, the basis physics included and detailed information about the numerical algorithms employed. Finally, some examples are presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Alignment Focus of Daily Image Guidance for Concurrent Treatment of Prostate and Pelvic Lymph Nodes

Purpose: To determine the dosimetric impact of daily imaging alignment focus on the prostate soft tissue versus the pelvic bones for the concurrent treatment of the prostate and pelvic lymph nodes (PLN) and to assess whether multileaf collimator (MLC) tracking or adaptive planning (ART) is necessary with the current clinical planning margins of 8 mm/6 mm posterior to the prostate and 5 mm to the PLN. Methods and Materials: A total of 124 kilovoltage cone-beam computed tomography (kV-CBCT) images from 6 patients were studied. For each KV-CBCT, 4 plans were retrospectively created using an isocenter shifting method with 2 different alignment focuses (prostate, PLN), an MLC shifting method, and the ART method. The selected dosimetric endpoints were compared among these plans. Results: For the isoshift contour, isoshift bone, MLC shift, and ART plans, D99 of the prostate was ≥97% of the prescription dose in 97.6%, 73.4%, 98.4%, and 96.8% of 124 fractions, respectively. Accordingly, D99 of the PLN was ≥97% of the prescription dose in 98.4%, 98.4%, 98.4%, and 100% of 124 fractions, respectively. For the rectum, D5 exceeded 105% of the planned D5 (and D5 of ART plans) in 11% (4%), 10% (2%), and 13% (5%) of 124 fractions, respectively. For the bladder, D5 exceeded 105% of the planned D5 (and D5 of ART) plans in 0% (2%), 0% (2%), and 0% (1%) of 124 fractions, respectively. Conclusion: For concurrent treatment of the prostate and PLN, with a planning margin to the prostate of 8 mm/6 mm posterior and a planning margin of 5 mm to the PLN, aligning to the prostate soft tissue can achieve adequate dose coverage to the both target volumes; aligning to the pelvic bone would result in underdosing to the prostate in one-third of fractions. With these planning margins, MLC tracking and ART methods have no dosimetric advantages.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Optimized manufacturing process for multilayer two-dimensional focusing mirrors in laboratory X-ray applications

Recent advances in laboratory X-ray applications require high-performance optical components that achieve exceptional imaging resolution and beam uniformity within compact experimental setups. Montel mirrors have become a preferred solution due to their unique dual-reflection focusing mechanism and a space-efficient design. Here, in this study, we present an effective manufacturing process for producing Montel mirrors tailored to focus laboratory X-ray beams. The mirrors were fabricated from single-crystal silicon substrates, chosen for their high mechanical stability and compatibility with precision polishing techniques. Our approach begins with the integration of a deterministic chemo-mechanical polishing (CMP)-based pre-shaping step followed by ion beam figuring (IBF), significantly improving manufacturing efficiency. Subsequently, our custom-developed advanced metrology and IBF techniques were employed for fabricating an off-axis, elliptical cylinder Montel mirror system with a 6-mrad total slope, with stringent optical specifications. While post-IBF processes, including multilayer coating, dicing, and gluing, introduced minor surface errors, yet their impact on performance remained negligible. The Montel mirrors manufactured with the optimized process exhibited significantly improved beam uniformity and a reduced focal spot size. These findings validate our approach as a viable solution for high-precision Montel mirror fabrication and facilitate further advancements in laboratory X-ray applications.

36 MATERIALS SCIENCE↗

The Milky Way, coming into focus: Precision astrometry probes its evolution and its dark matter

The growing trove of precision astrometric observations from the Gaia space telescope and other surveys is revealing the structure and dynamics of the Milky Way in ever more exquisite detail. We summarize the current status of our understanding of the structure and the characteristics of the Milky Way, and we review the emerging picture: the Milky Way is evolving through interactions with the massive satellite galaxies that stud its volume, with evidence pointing to a cataclysmic past. It is also woven with stellar streams, and observations of streams, satellites, and field stars offer new constraints on its dark matter, both on its spatial distribution and its fundamental nature. The recent years have brought much focus to the study of dwarf galaxies found within our Galaxy’s halo and their internal matter distributions. In this review, we focus on the predictions of the cold dark matter paradigm at small mass scales through precision astrometric measurements, and we summarize the modern consensus on the extent to which small-scale probes are consistent with this paradigm. We note the discovery prospects of these studies, and also how they intertwine with probes of the dynamics and evolution of the Milky Way in various and distinct ways.

79 ASTRONOMY AND ASTROPHYSICS↗

Depth profile of a time-reversal focus in an elastic solid

The out-of-plane velocity component is focused on the flat surface of an isotropic solid sample using the principle of time reversal. This experiment is often reproduced in the context of nondestructive testing for imaging features near the surface of the sample. However, it is not clear how deep the focus extends into the bulk of the sample and what its profile is. In this paper, this question is answered using both numerical simulations and experimental data. The profiles of the foci are expressed in terms of the wavelengths of the dominant waves, based on the interpretation of the Lamb’s problem and the use of the diffraction limit.

36 MATERIALS SCIENCE↗

MS25: Materials Science-Focused Benchmark Data Set for Machine Learning Interatomic Potentials

Here, we present MS25, a benchmark data set for evaluating machine learning interatomic potentials (MLIPs) across diverse materials-relevant systems including MgO surfaces, liquid water, zeolites, a catalytic Pt surface reaction, high-entropy alloys (HEAs), and disordered Zr-oxides. Five MLIP architectures (MACE, NequIP, Allegro, MTP, and Torch-ANI) are trained and tested, focusing not only on traditional metrics (energies, forces, and stresses) but also explicitly validating derived physical observables such as lattice constants, volumes, and reaction barriers. We find that most models reach comparable accuracy on standard error metrics across the simple systems, although equivariant MLIPs offer 1.5–2× improvements over nonequivariant MLIPs in energy and force error for structurally complex or compositionally disordered environments such as HEAs and Zr–O systems. Our analysis highlights that low errors in energy and force predictions do not guarantee reliable observables, emphasizing the necessity of explicit validation. We demonstrate limitations in cross-framework transferability, as models trained on one zeolite framework (CHA) fail to reliably generalize to predictions of structurally distinct frameworks (e.g., MFI). Size-extensive tests show some dependence on system size for MgO, resulting from forced periodicity. The HEA and Zr–O data sets are identified as challenging tests for future benchmarks and MLIP model architecture developments as they show significant differentiation in error between MLIP architectures and are still relatively difficult at 1000 training images. Moving forward, we recommend that benchmarking efforts shift their focus from marginal accuracy improvements in energy and force errors toward identifying and understanding model failure modes, rigorously assessing transferability, and evaluating how their errors affect observable predictions. For researchers looking to choose an MLIP architecture, we suggest selecting equivariant MLIP architectures if the complexity of the system is a challenge. For simple materials problems, auxiliary features such as integration with molecular dynamics engines, trade-offs between computational data set generation cost vs MLIP inference speed, and framework integration may play a more important decision factor than small differences in error metrics that are unlikely to matter for production-level research.

chemical structure↗

Selected Area Manipulation of MoS 2 via Focused Electron Beam-Induced Etching for Nanoscale Device Editing

Here we demonstrate direct-write patterning of single and multilayer MoS 2 via a focused electron beam-induced etching (FEBIE) process mediated with the XeF 2 precursor. MoS 2 etching is performed at various currents, areal doses, on different substrates, and characterized using scanning electron and atomic force microscopies as well as Raman and photoluminescence spectroscopies. Scanning transmission electron microscopy reveals a sub-40 nm etching resolution and the progression of point defects and lateral etching of the consequent unsaturated bonds. The results confirm that the electron beam-induced etching process is minimally invasive to the underlying material in comparison to ion beam techniques, which damage the subsurface material. Single-layer MoS 2 field-effect transistors are fabricated, and device characteristics are compared for channels that are edited via the selected area etching process. The source–drain current at constant gate and source–drain voltage scale linearly with the edited channel width. Moreover, the mobility of the narrowest channel width decreases, suggesting that backscattered and secondary electrons collaterally affect the periphery of the removed area. Focused electron beam doses on single-layer transistors below the etching threshold were also explored as a means to modify/thin the channel layer. The FEBIE exposures showed demonstrative effects via the transistor transfer characteristics, photoluminescence spectroscopy, and Raman spectroscopy. While strategies to minimize backscattered and secondary electron interactions outside of the scanned regions require further investigation, here, we show that FEBIE is a viable approach for selective nanoscale editing of MoS 2 devices.

36 MATERIALS SCIENCE↗

Perfect X-ray focusing via fitting corrective glasses to aberrated optics

Due to their short wavelength, X-rays can in principle be focused down to a few nanometres and below. At the same time, it is this short wavelength that puts stringent requirements on X-ray optics and their metrology. Both are limited by today’s technology. In this work, we present accurate at wavelength measurements of residual aberrations of a refractive X-ray lens using ptychography to manufacture a corrective phase plate. Together with the fitted phase plate the optics shows diffraction-limited performance, generating a nearly Gaussian beam profile with a Strehl ratio above 0.8. As a result, this scheme can be applied to any other focusing optics, thus solving the X-ray optical problem at synchrotron radiation sources and X-ray free-electron lasers.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Anomalous material-dependent transport of focused, laser-driven proton beams

Intense lasers can accelerate protons in sufficient numbers and energy that the resulting beam can heat materials to exotic warm (10s of eV temperature) states. Here we show with experimental data that a laser-driven proton beam focused onto a target heated it in a localized spot with size strongly dependent upon material and as small as 35 mm radius. Simulations indicate that cold stopping power values cannot model the intense proton beam transport in solid targets well enough to match the large differences observed. In the experiment a 74 J, 670 f s laser drove a focusing proton beam that transported through different thicknesses of solid Mylar, Al, Cu or Au, eventually heating a rear, thin, Au witness layer. The XUV emission seen from the rear of the Au indicated a clear dependence of proton beam transport upon atomic number, Z, of the transport layer: a larger and brighter emission spot was measured after proton transport through the lower Z foils even with equal mass density for supposed equivalent proton stopping range. Beam transport dynamics pertaining to the observed heated spot were investigated numerically with a particle-in-cell (PIC) code. In simulations protons moving through an Al transport layer result in higher Au temperature responsible for higher Au radiant emittance compared to a Cu transport case. As a result, the inferred finding that proton stopping varies with temperature in different materials, considerably changing the beam heating profile, can guide applications seeking to controllably heat targets with intense proton beams.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Generation of focusing ion beams by magnetized electron sheath acceleration

Abstract We present the first 3D fully kinetic simulations of laser driven sheath-based ion acceleration with a kilotesla-level applied magnetic field. The application of a strong magnetic field significantly and beneficially alters sheath based ion acceleration and creates two distinct stages in the acceleration process associated with the time-evolving magnetization of the hot electron sheath. The first stage delivers dramatically enhanced acceleration, and the second reverses the typical outward-directed topology of the sheath electric field into a focusing configuration. The net result is a focusing, magnetic field-directed ion source of multiple species with strongly enhanced energy and number. The predicted improvements in ion source characteristics are desirable for applications and suggest a route to experimentally confirm magnetization-related effects in the high energy density regime. We additionally perform a comparison between 2D and 3D simulation geometry, on which basis we predict the feasibility of observing magnetic field effects under experimentally relevant conditions.

42 ENGINEERING↗

X-ray free-electron lasing in a flying-focus undulator

Laser-driven free-electron lasers (LDFELs) replace magnetostatic undulators with the electromagnetic fields of a laser pulse. Because the undulator period is half the wavelength of the laser pulse, LDFELs can amplify X rays using lower electron energies and over shorter interaction lengths than a traditional free-electron laser. In LDFELs driven by conventional laser pulses, the undulator uniformity required for high gain necessitates large laser-pulse energies. Here, we show that a flying-focus pulse provides the undulator uniformity required to reach high gain with a substantially lower energy than a conventional pulse. The flying-focus pulse features an intensity peak that travels in the opposite direction of its phase fronts. This enables an LDFEL configuration where an electron beam collides head-on with the phase fronts and experiences a near-constant undulator strength as it co-propagates with the intensity peak. Three-dimensional simulations of this configuration demonstrate the generation of megawatts of coherent X-ray radiation with 20 × less energy than a conventional laser pulse.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Double-flow focused liquid injector for efficient serial femtosecond crystallography

Serial femtosecond crystallography requires reliable and efficient delivery of fresh crystals across the beam of an X-ray free-electron laser over the course of an experiment. We introduce a double-flow focusing nozzle to meet this challenge, with significantly reduced sample consumption, while improving jet stability over previous generations of nozzles. We demonstrate its use to determine the first room-temperature structure of RNA polymerase II at high resolution, revealing new structural details. Furthermore, the double flow-focusing nozzles were successfully tested with three other protein samples and the first room temperature structure of an extradiol ring-cleaving dioxygenase was solved by utilizing the improved operation and characteristics of these devices.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Monte Carlo simulation of nanoscale material focused ion beam gas-assisted etching: Ga + and Ne + etching of SiO 2 in the presence of a XeF 2 precursor gas

Elucidating energetic particle-precursor gas–solid interactions is critical to many atomic and nanoscale synthesis approaches. Focused ion beam sputtering and gas-assisted etching are among the more commonly used direct-write nanomachining techniques that have been developed. Here, we demonstrate a method to simulate gas-assisted focused ion beam (FIB) induced etching for editing/machining materials at the nanoscale. The method consists of an ion–solid Monte Carlo simulation, to which we have added additional routines to emulate detailed gas precursor–solid interactions, including the gas flux, adsorption, and desorption. Furthermore, for the reactive etching component, a model is presented by which energetic ions/target atoms, and secondary electrons, transfer energy to adsorbed gas molecules. The simulation is described in detail, and is validated using analytical and experimental data for surface gas adsorption, and etching yields. The method is used to study XeF 2 assisted FIB induced etching of nanoscale vias, using both a 35 keV Ga + , and a 10 keV Ne + beam. Remarkable agreement between experimental and simulated nanoscale vias is demonstrated over a range of experimental conditions. Importantly, we demonstrate that the resolution depends strongly on the XeF 2 gas flux, with optimal resolution obtained for either pure sputtering, or saturated gas coverage; saturated gas coverage has the clear advantage of lower overall dose, and thus lower implant damage, and much faster processing.

36 MATERIALS SCIENCE↗

Safely probing the chemistry of Chernobyl nuclear fuel using micro-focus X-ray analysis

Detailed chemical analysis of the solidified molten fuel still residing in the stricken Chernobyl reactor unit 4 are inferred using multi-modal micro-focus X-ray analysis of a low-radioactivity proxy. A fascinating mixture of molten UO 2 , nuclear fuel cladding, concrete, stainless steel and other nuclear reactor components, these materials behaved like lava, solidifying to form a complex, highly radioactive glass-ceramic. Using element-specific chemical probes (micro-X-ray fluorescence and X-ray absorption spectroscopy), coupled with micro-diffraction analysis, the crystalline phase assemblage of simulants of these heterogeneous materials was established, which included “chernobylite” and a range of compositions in the (U 1-x Zr x )O 2 solid solution. Novel insight to nuclear accident fuel chemistry was obtained by establishing the oxidation state and local coordination of uranium not only in these crystalline phases, but uniquely in the amorphous fraction of the material, which varied depending on the history of the nuclear lava as it flowed through the reactor. This study demonstrates that micro-focus X-ray analysis of very small fractions of material can yield rich chemical information, which can be applied to nuclear-melt down materials to aid decommissioning and nuclear fuel management at nuclear accident sites.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Electrostatic storage ring with focusing provided by the space charge of an electron plasma

Electrostatic storage rings are used for a variety of atomic physics studies. An advantage of electrostatic storage rings is that heavy ions can be confined. An electrostatic storage ring that employs the space charge of an electron plasma for focusing is described. An additional advantage of the present concept is that slow ions, or even a stationary ion plasma, can be confined. The concept employs an artificially structured boundary, which is defined at present as one that produces a spatially periodic static field such that the spatial period and range of the field are much smaller than the dimensions of a plasma or charged-particle beam that is confined by the field. An artificially structured boundary is used to confine a non-neutral electron plasma along the storage ring. The electron plasma would be effectively unmagnetized, except near an outer boundary where the confining electromagnetic field would reside. The electron plasma produces a radially inward electric field, which focuses the ion beam. Self-consistently computed radial beam profiles are reported.

43 PARTICLE ACCELERATORS↗

Preliminary study on development of 300 Kv compact focused gaseous ion beam system

A new 300 kV compact focused gaseous ion beam (gas-FIB) system with three-stage acceleration lens was constructed at JAEA. The preliminary experiments of formation of the focused gaseous ion beams were carried out to show the availability of the gas-FIB system as a writing tool for 3D proton lithography. As a result of the experiments, it was proved that the focal point was kept at the same position under changing the kinetic energy but with keeping the kinetic energy ratio constant, which was defined as the ratio of kinetic energy in object side to that in image side for the third acceleration lens. This characteristic of the gas-FIB is a good point to advance the 3D proton lithography changing penetration depth in a sample by varying the beam energy.

43 PARTICLE ACCELERATORS↗